990 resultados para Endodontic cements


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the setting time and the thermal expansion coefficient of 2 endodontic cements, MTA-Angelus and a novel cement called CER. The setting time was determined in accordance to ANSI/ADA specifications no. 57. Three samples of 10 mm diameter and 2 mm thickness were prepared for each cement. The thermal expansion measurements were performed by strain gauge technique. Four samples of each cement were prepared using silicone rings of 5 mm diameter and 2 mm thickness. The data were analyzed statistically using the Student t test. The setting time obtained for the MTA-Angelus and CER cements was 15 (SD 1) min and 7 (SD 1) min, respectively. The linear coefficient of thermal expansion was 8.86 (SD 0.28) mu strain/degrees C for MTA-Angelus and 11.76 (SD 1.20) mu strain/degrees C for CER. The statistical analysis showed significant difference (P < .05) in the setting time and linear coefficient of thermal expansion between the 2 cements. The CER cement has a coefficient of expansion similar to dentin, which could contribute to a decrease of microleakage degree.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this work was to evaluate the biological compatibility of the Sealapex, Apexit, Sealer 26 and Ketac Endo endodontic cements. Polyethylene tubes containing these cements were implanted in the subcutaneous tissue of 40 (forty) rats. The animals were sacrificed after 14 and 90 days. A descriptive analysis of the reactions found in the connective tissue by contact with the cements was performed. The magnitude of inflammatory infiltrate, the presence and predominance of cell types and their distribution as to the filling material and reparative phenomena, such as fibroblastic and angioblastic proliferation and formation of fibrous capsules, were subjectively measured. After 90 days, all cements presented statistically significant reduction of the inflammatory reaction, presence of a fibrous tissue capsule in contact with the opening of the tubes containing the filling materials, and reduction of fibroblastic proliferation. Angioblastic proliferation decreased only for the Sealer 26 and Ketac Endo groups. All cements tested were either partially or totally phagocyted, and the mildest inflammatory response was found for the Sealer 26 group at both evaluation periods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente estudo teve como objetivo comparar a qualidade do selamento promovido por 3 cimentos reparadores endodônticos: Ceramicrete, iRoot-BP Plus e BioAggregate, com o ProRoot MTA branco, utilizando o modelo de infiltração de glicose sob pressão. 64 incisivos centrais superiores, recém-extraídos e sem tratamento endodôntico foram selecionados. A instrumentação do canal radicular foi realizada em todos os dentes com brocas Gates-Glidden e limas K-Flexofile (Dentsply Maillefer, Ballaigues Suíça), 1mm aquém do ápice. A patência foraminal foi confirmada a cada instrumento usado. Os dentes tiveram suas coroas removidas padronizando-os em 15mm de comprimento. Foi realizada apicetomia a 3mm do ápice e o preparo da cavidade retrógrada com o auxílio do ultrassom Various 350 (NSKNakanishi Inc., Tóquio, Japão) e da ponta E32D (NSKNakanishi Inc., Tóquio, Japão). As raízes foram distribuídas, randomicamente, em quatro grupos experimentais (n=15): G1Ceramicrete, G2iRoot BP Plus, G3BioAggregate e G4ProRoot MTA branco. Como controle negativo (n=2) foram utilizados dentes hígidos, e como controle positivo (n=2), dentes acessados e com patência confirmada. Os cimentos reparadores foram manipulados seguindo as recomendações do fabricante e inseridos na cavidade retrógrada utilizando a mesma ponta ultrassônica usada no preparo. As amostras foram mantidas na presença de umidade por 72h para o completo endurecimento dos materiais. As raízes foram montadas em um dispositivo de dupla-câmara selada para a infiltração da glicose. Foram utilizados 0,75ml de solução de glicose a 1Mol/L na câmara superior e 0,75ml de água destilada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão, que permitiu a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15psi durante 1 hora. Uma alíquota de 10l foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada com o auxílio do Kit GlucoseHK (Megazyme, Wicklow, Irlanda) e de um espectrofotômetro de luz visível (Campsec M330, Cambridge, Reino Unido) em um comprimento de onda de 340nm. O teste não-paramétrico Kruskal-Wallis e o teste Dunns foram utilizados na análise estatística. Os resultados encontrados demonstraram que houve diferença significativa entre os grupos experimentais (p=0,0036). O BioAggregate apresentou a maior concentração de glicose-1,85(g/L), seguido do ProRoot MTA-1,2; IRoot BP-0,85 e Ceramicrete-0,75. Não houve diferença entre os três novos cimentos reparadores e o material padrão-ouro (p>0,05). Não houve diferença entre Ceramicrete e iRoot BP Plus (p>0,05), porém estes foram estatisticamente diferentes do BioAggregate (p<0,05). Diante dos resultados obtidos, pode-se concluir que: nenhum dos cimentos testados foi capaz de promover selamento hermético; os três novos cimentos testados não revelaram o mesmo padrão de selamento; os três novos cimentos testados revelaram um padrão de selamento semelhante a do ProRoot MTA branco; e o Ceramicrete e o iRoot BP Plus apresentaram padrão de selamento superior em comparação com o BioAggregate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O sucesso do tratamento endodôntico depende da cuidadosa realização de todas as suas fases, terminando com uma obturação tridimensional que alcance todo o sistema de canais radiculares. Desta forma, os materiais obturadores, ou as substâncias liberadas, entrarão em contato com os tecidos perirradiculares, o que poderá influenciar a resposta inflamatória e o processo de reparo. A terapia laser de baixa potência (TLBP) tem sido estudada quanto à sua ação anti-inflamatória, favorecendo o reparo. O objetivo deste estudo foi investigar a produção das citocinas IL-1β, IL-6 e IL-8 por fibroblastos de gengiva humana (linhagem FMM1) como resposta à presença dos extratos dos cimentos endodônticos AH Plus, MTA Fillapex e EndoSequence BC Sealer, bem como a eficácia da TLBP, neste modelo. Para isto, extratos destes cimentos, recém-manipulados e após 24 h do endurecimento, foram preparados em meio de cultura DMEM fresco, conforme as normas ISO 10993-12. Inicialmente, a citotoxicidade dos cimentos foi avaliada, após a interação das células com a diluição seriada destes extratos (1:1 a 1:16), por meio do ensaio MTT. Para a análise da produção de citocinas, 106 células por poço foram cultivadas em placas de cultura de 24 poços, para a interação com os extratos dos cimentos, na diluição 1:4. Estabeleceram-se os grupos não irradiado e irradiado. No grupo irradiado, as culturas celulares receberam duas irradiações do laser InGaAlP (660 nm, 30 mW, 5 J/cm2 e área do feixe de 0,028 cm2), com intervalo de 12 h. O grupo não irradiado foi submetido às mesmas condições ambientais que o irradiado. Os sobrenadantes das culturas foram coletados, centrifugados, aliquotados e armazenados congelados, para a posterior análise pelo ensaio de ELISA. Todos os dados obtidos (médias erro padrão) foram tratados estatisticamente por ANOVA one-way, complementado pelo teste de Tuckey e ANOVA two-way, com correção de Bonferroni (p< 0,05). A citotoxicidade dos cimentos AH Plus e EndoSequence BC Sealer revelou-se tempo/concentração-dependente, enquanto a do MTA Fillapex mostrou-se concentração-dependente. Os cimentos endodônticos induziram a produção das citocinas IL-1β, IL-6 e IL-8 pelos fibroblastos, sem diferença significativa com os controles (p> 0,05). Somente o LPS de E. coli induziu a secreção de IL-8, com diferença estatística (p< 0,05). A TLBP não foi capaz de modular a produção das citocinas em questão, significativamente.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sealer 26® cement contains bisphenol epoxy resin associated with calcium hydroxide, presenting smaller radiopacity than other endodontic cements. Aiming to improve this property, iodoform has been added in its composition. However, this addition's possible changes in physical and chemical properties still need to be studied. OBJECTIVE: To evaluate the apical sealing ability, solubility, and pH of Sealer 26® alone or with iodoform, at several proportions. MATERIAL AND METHODS: Three experimental mixtures of Sealer 26®, alone or with iodoform, were prepared and subjected to solubility test. Additionally, these combinations were inserted into polyethylene tubes and immersed in distilled water, and, their pH was evaluated after 24-h and 7-day periods. Subsequently, forty roots of extracted lower incisors subdivided into four groups of 10 specimens each, were retrograde filled with one of the previously described mixtures and gutta-percha points. The roots were immersed in Rhodamine B, under vacuum, for 72 hours. After this period, the specimens were longitudinally sectioned, root fragments photographed, these images scanned, and apical infiltration measured by Image tool software. The obtained data were subjected to statistical analysis, at a significance level of 5%. RESULTS: Marginal leakage and solubility tests did not show any difference among the experimental groups (p > 0.05). pH analysis was only statistically different at 24-h period and between Sealer 26® alone and 1.1g iodoform group (p < 0.05). CONCLUSION: The presence of iodoform in Sealer 26®, at the used proportions, did not alter the solubility, apical marginal leakage and pH properties of the original cement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the antimicrobial activity of different root-end filling materials - Sealer 26, Sealapex with zinc oxide, zinc oxide and eugenol, white and gray Portland cement, white and gray MTA-Angelus, and gray Pro Root MTA - against six different microorganism strains. The agar diffusion method was used. A base layer was made using Müller-Hinton agar (MH) and wells were formed by removing the agar. The materials were placed in the wells immediately after manipulation. The microorganisms used were: Micrococcus luteus (ATCC9341), Staphylococcus aureus (ATCC6538), Escherichia coli (ATCC10538), Pseudomonas aeruginosa (ATCC27853), Candida albicans (ATCC 10231), and Enterococcus faecalis (ATCC 10541). The plates were kept at room temperature for 2 h for prediffusion and then incubated at 37 degrees C for 24 h. Triphenyltetrazolium chloride 0.05% gel was added for optimization, and the zones of inhibition were measured. Data were subjected to the Kruskal-Wallis and Dunn tests at a 5% significance level. The results showed that all materials had antimicrobial activity against all the tested strains. Analysis of the efficacy of the materials against the microbial strains showed that Sealapex with zinc oxide, zinc oxide and eugenol and Sealer 26 created larger inhibition halos than the MTA-based and Portland cements (P < 0.05). On the basis of the methodology used, it may be concluded that all endodontic sealers, MTA-based and Portland cements evaluated in this study possess antimicrobial activity, particularly the endodontic sealers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cylindrical specimens (6 mm high x 4 mm diameter) of the endodontic grade glass-ionomer (Ketac Endo) were exposed to various media for 1 week, after which changes in their mass, pH of storage medium, and ion release were determined. In water, this cement was shown to release reasonable amounts of sodium, aluminium and silicon, together with smaller amounts of calcium and phosphorus, as well as taking up 2.41% by mass of water. A comparison with the restorative grade materials (Ketac Molar, ex 3M ESPE and Fuji IX, ex GC) showed both ion release and water uptake to be greater. All three cements shifted pH from 7 to around 6 with no significant differences between them. Other storage media were found to alter the pattern of ion release. Lactic acid caused an increase, whereas both saturated calcium hydroxide and 0.6% sodium hypochlorite, caused decreases. This suppression of ion-release may be significant clinically. Aluminium is the most potentially hazardous of the ions involved but amounts released were low compared with levels previously reported to show biological damage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the study was to evaluate the bond strength of fibre glass and carbon fibre posts in the root canal walls cemented with self-adhesive (RelyX-Unicem) and chemical (Cement-Post) resin cements. Forty maxillary canines were divided into four groups according to the cement and post used and submitted to the push-out test (0.5 mm min(-1)). The data were submitted to statistical analysis (2-way ANOVA, Bonferroni - P < 0.05) and fracture analysis by Scanning Electronic Microscopy. Fibre glass presented the best results when cemented with RelyX-Unicem and Cement-Post (P < 0.05). RelyX-Unicem presented the highest bond strength values for both posts (P < 0.05). Fracture analysis showed predominance of cohesive fracture of post for RelyX-Unicem and adhesive fracture between dentin/cement and mixed for Cement-Post. The bond strength values were significantly affected by the type of post and cement used and the highest values were found for fibre glass posts and RelyX-Unicem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to determine the effect of the exposure of different endodontic materials to different dye solutions by evaluating the optical density of the dye solutions. Seventy-five plastic tubes were filled with one of the following materials: AH Plus, Sealapex, Portland cement, MTA (Angelus and Pro Root) and fifteen control plastic tubes were not. Each specimen of material and control was immersed in a container with 1 ml of each dye solution. A 0.1 ml-dye solution aliquote was removed before immersion and after 12, 24, 48 and 72 hours of each specimen immersion to record its optical density (OD) in a spectrophotometer. Statistical analysis was performed with ANOVA and Tukey tests (5%). No significant difference was found among any of the solution OD values for AH Plus cement. Portland cement promoted different OD values after 12 hours of immersion. MTA-Angelus cement presented different OD values only for 2% rhodamine B and the MTA-Pro Root cement presented different OD values in all 2% rhodamine B samples. Sealapex cement promoted a reduction in the India Ink OD values. Dye evaluation through OD seems to be an interesting method to select the best dye solution to use in a given marginal leakage study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the dimensional alterations and the solubility of two experimental endodontic sealers based on Copaifera multijuga oil-resin (Biosealer) and castor oil bean cement (Poliquil), maintained in different storage solutions. Twenty specimens (3 mm diameter and 2 mm height) of each sealer were assigned to 2 groups (n=10) according to the storage solution: simulated tissue fluid (STF) or distilled water (DW). The specimens were stored in these solutions during 90 days, being removed every 30 days for weighting. The solutions were renewed every 15 days. The results were subjected to statistical analysis by Dunn's and Mann-Whitney tests (α=0.05). The solubility of Poliquil was higher in STF (38.4 ± 36.0) than in DW (28.4 ± 15.0), while Biosealer showed higher solubility in DW (34.61 ± 6.0) than in STF (18.59 ± 8.0). The storage solution influenced the behavior of sealers in relation to the weight variation (p=0.0001). Poliquil presented higher variation of weight independent of the solution (p=0.239). Biosealer also presented higher variation of weight regardless of the solution (p=0.0001). The solubility of Biosealer was different from that of Poliquil, but both sealers showed low solubility in STF. Under the tested conditions, neither of the materials were according to the ADA'S specification.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the transdentinal cytotoxicity of resin-based luting cements (RBLCs), with no HEMA in their composition, to odontoblast-like cells. Human dentine discs 0.3 mm thick were adapted to artificial pulp chambers (APCs) and placed in wells of 24-well plates containing 1 mL of culture medium (DMEM). Two categories of HEMA-free RBLCs were evaluated: group 1, self-adhesive Rely X Unicem (RU; 3M ESPE), applied directly to the dentine substrate; and group 2, Rely X ARC (RARC; 3M ESPE), applied to dentine previously acid-etched and treated with a bonding agent. In group 3 (control), considered as representing 100% cell metabolic activity, no treatment was performed on dentine. The APC/disc sets were incubated for 24 h or 7 days at 37 °C and 5% CO2 . Then, the extracts (DMEM + dental materials components that diffused through dentine) were applied to cultured odontoblast-like MDPC-23 cells for 24 h. After that, the cell viability (MTT assay), cell morphology (SEM), total protein production (TP) and alkaline phosphatase (ALP) activity were assessed. Data from MTT assay and TP production were analysed by Kruskal-Wallis and Mann-Whitney tests (α = 5%). Data from ALP activity were analysed by one-way anova and Tukey's test (α = 5%). In group 1, a slight reduction in cell viability (11.6% and 16.8% for 24-h and 7-day periods, respectively) and ALP activity (13.5% and 17.9% for 24-h and 7-day periods, respectively) was observed, with no significant difference from group 3 (control) (P > 0.05). In group 2, a significant reduction in cell viability, TP production and ALP activity compared with group 3 (control) occurred (P < 0.05), regardless of incubation time. Alteration in MDPC-23 cell morphology was observed only in group 2. HEMA-free Rely X ARC cement caused greater toxicity to odontoblast-like MDPC-23 cells than did Rely X Unicem cement when both resin-based luting materials were applied to dentine as recommended by the manufacturer.