995 resultados para AAS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The volume contains handwritten copies of lectures delivered by Sewall to students, an 1780 letter from Antoine Court de Gébelin written in French and glued into the front inside cover, a preface to the set of lectures, an autobiographical sketch of Sewall, and the statutes governing the Hancock Professorship of Hebrew and other Oriental Languages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Produced water is a major problem associated with the crude oil extraction activity. The monitoring of the levels of metals in the waste is constant and requires the use of sensitive analytical techniques. However, the determination of trace elements can often require a pre-concentration step. The objective of this study was to develop a simple and rapid analytical method for the extraction and pre-concentration based on extraction phenomenon cloud point for the determination of Cd, Pb and Tl in produced water samples by spectrometry of high resolution Absorption source continues and atomization graphite furnace. The Box Behnken design was used to obtain the optimal condition of extraction of analytes. The factors were evaluated: concentration of complexing agent (o,o-dietilditilfosfato ammonium, DDTP), the concentration of hydrochloric acid and concentration of surfactant (Triton X -114). The optimal condition obtained through extraction was: 0,6% m v-1 DDTP, HCl 0,3 mol L-1 and 0,2% m v-1 of Triton X - 114 for Pb; 0,7% m v-1 DDTP, HCl 0,8 mol L-1 and 0,2% m v-1 Triton X-114 for Cd. For Tl was evidenced that best extraction condition occurs with no DDTP, the extraction conditions were HCl 1,0 mol L-1 e 1,0% m v-1 de Triton X - 114. The limits of detection for the proposed method were 0,005 µg L-1 , 0,03 µg L-1 and 0,09 µg L-1 to Cd, Pb and Tl, Respectively. Enrichment factors Were greater than 10 times. The method was applied to the water produced in the Potiguar basin, and addition and recovery tests were performed, and values were between 81% and 120%. The precision was expressed with relative standard deviation (RSD) is less than 5%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination and monitoring of metallic contaminants in water is a task that must be continuous, leading to the importance of the development, modification and optimization of analytical methodologies capab le of determining the various metal contaminants in natural environments, because, in many cases, the ava ilable instrumentation does not provide enough sensibility for the determination of trace values . In this study, a method of extraction and pre- concentration using a microemulsion system with in the Winsor II equilibrium was tested and optimized for the determination of Co, Cd, P b, Tl, Cu and Ni through the technique of high- resolution atomic absorption spectrometry using a continuum source (HR-CS AAS). The optimization of the temperature program for the graphite furnace (HR-CS AAS GF) was performed through the pyrolysis and atomization curves for the analytes Cd, Pb, Co and Tl with and without the use of different chemical modifiers. Cu and Ni we re analyzed by flame atomization (HR-CS F AAS) after pre-concentr ation, having the sample introduction system optimized for the realization of discrete sampling. Salinity and pH levels were also analyzed as influencing factors in the efficiency of the extraction. As final numbers, 6 g L -1 of Na (as NaCl) and 1% of HNO 3 (v/v) were defined. For the determination of the optimum extraction point, a centroid-simplex statistical plan was a pplied, having chosen as the optimum points of extraction for all of the analytes, the follo wing proportions: 70% aqueous phase, 10% oil phase and 20% co-surfactant/surfactant (C/S = 4). After extraction, the metals were determined and the merit figures obtained for the proposed method were: LOD 0,09, 0,01, 0,06, 0,05, 0,6 and 1,5 μg L -1 for Pb, Cd, Tl, Co, Cu and Ni, re spectively. Line ar ranges of ,1- 2,0 μg L -1 for Pb, 0,01-2,0 μg L -1 for Cd, 1,0 - 20 μg L -1 for Tl, 0,1-5,0 μg L -1 for Co, 2-200 μg L -1 and for Cu e Ni 5-200 μg L -1 were obtained. The enrichment factors obtained ranged between 6 and 19. Recovery testing with the certified sample show ed recovery values (n = 3, certified values) after extraction of 105 and 101, 100 and 104% for Pb, Cd, Cu and Ni respectively. Samples of sweet waters of lake Jiqui, saline water from Potengi river and water produced from the oil industry (PETROBRAS) were spiked and the recovery (n = 3) for the analytes were between 80 and 112% confirming th at the proposed method can be used in the extraction. The proposed method enabled the sepa ration of metals from complex matrices, and with good pre-concentration factor, consistent with the MPV (allowed limits) compared to CONAMA Resolution No. 357/2005 which regulat es the quality of fresh surface water, brackish and saline water in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variations in the Indian summer monsoon (ISM) intensity during the last 16.7?ka have been studied using organic carbon (Corg), d15N of sedimentary organic matter, CaCO3, sediment texture, d18OC, and Mg/Ca-derived sea surface temperature, d18O of sea water and sea surface salinity, in a 14C-dated sediment core from the eastern Arabian Sea. The d18O in water and planktonic foraminifera shells off the central west coast of India may be controlled by the ISM intensity as this area receives high precipitation and land runoff. Also, the Corg and CaCO3 contents of sediments and d15N of sedimentary organic matter may be linked to ISM-induced productivity and denitrification. The results of the present study reveal that between 16 and 15.2 ka BP, the ISM was weak with minor fluctuations and started intensifying around 15.2 ka BP, at the onset of the Bølling-Ållerød (B-A) event. The B-A event is characterized by higher water column denitrification rates comparable to the present day. The ISM signatures observed in the d18OC record of B-A event compare well with those from Timta cave of the western Himalayas and also the Asian summer monsoon signatures from the Hulu caves in China and warming signatures in Greenland Ice Sheet Project 2 (GISP2) suggesting atmospheric teleconnections through Intertropical Convergence Zone. The boundary between the Younger Dryas and the Holocene is discernible with small episodes of abrupt events of increased ISM intensity. This decrease in d18OC values at ~11.8 ka BP is contemporary with June solar insolation maximum at 30° north and the increase in methane in the GISP2 ice core supporting episodes of warmer climate and increase in ISM intensity. The ISM seems to have been most stable between 7 and 5.6 ka BP. The core exhibits periodicity of 500 years that is comparable to the Atlantic water formation and the Chinese monsoon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective The Active Australia Survey (AAS) is used for physical activity (PA) surveillance in the general Australian adult population, but its validity in older adults has not been evaluated. Our aim was to examine the convergent validity of the AAS questions in older adults. Design The AAS was validated against pedometer step counts as an objective measure of PA, self-reported physical function, and a step-test to assess cardiorespiratory fitness. Method Participants were community-dwelling adults, aged 65-89 y, with the ability to walk 100 m. They completed a self-administered AAS and the step-test in one interview. One week earlier, they completed the Short Form-36 physical function subscale. Between these two interviews, they each wore a YAMAX Digiwalker SW200 pedometer and recorded daily steps. Using the AAS data, daily walking minutes and total PA minutes (walking, moderate-intensity PA and vigorous-intensity PA) were compared with the validity measures using Spearman rank-order correlations. Fifty-three adults completed the study. Results Median daily walking minutes were 34.2 (interquartile range [IQR] 17.1, 60.0), and median daily total PA minutes were 68.6 (IQR 31.4, 113.6). Walking and total PA minutes were both moderately correlated with pedometer steps (Spearman correlation r=0.42, p=0.003, for each) but not with step-test seconds to completion (r=-0.11, p=0.44; r=-0.25, p=0.08, respectively). Total PA minutes were significantly correlated with physical function scores (r=0.39, p=0.004), but walking minutes were not (r=0.15, p=0.29). Conclusions This initial examination of the psychometric properties of the AAS for older adults suggests that this surveillance tool has acceptable convergent validity for ambulatory, community-dwelling older adults.