954 resultados para 030106 Quality Assurance Chemometrics Traceability and Metrological Chemistry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chronic condition self-management education and training interventions such as the Stanford Self Management Programs (SMP) have the capacity to improve health and quality of life of people with chronic conditions whilst reducing the use of health services. This is in line with the outcomes from the recent Council of Australian Governments’ meeting where it was indicated that self-management will be a centrepiece in forthcoming chronic disease initiatives.
Aim: report on a large national pilot quality assurance program involving the implementation and of an evaluation and quality monitoring system for SMPs including the provision of structured feedback to courses course leaders and service providers. During 2005/06 the quality assurance program was implemented at 11 diverse organisations across Australia. The program involved assisting organisations apply the 42-item Health Education Impact Questionnaire (HEIQ), a chronic disease health education outcome measure, and then observe and evaluate the value and impact of the quality program. Interviews with course leaders (n=60) and course participants (n=35) have elicited views about course quality and feedback processes.
Results: The evaluation revealed enablers and barriers to effective implementation and sustainability. Important enablers were:
- Course Leaders and organisations valued an Australia-wide system that provided feedback on course
quality and the impact on participants.
- Course Leaders were strongly personally motivated to respond appropriately to HEI-Q course
report feedback.
- Completing the questionnaire provided participants with the opportunity to reflect on issues that
emerge in the course content and reflect on their progression at the end of the SSMP.
Sustainability issues included:
- Organisations and course leaders require support, training and flexibility on how to administer and
manage the use of the HEI-Q.
- Availability of administrative resources in organisations to support the quality assurance activities.
- The requirement that course leaders are trained in interpreting HEI-Q course report data.
A quality improvement framework was developed which identified the actions required of key stakeholders to
support effective implementation.
Discussion: With the increasing endorsement of SMP across sectors it is important that course quality is known, is acceptable, and is communicated to stakeholders to inform and engender confidence in the SSMP. To effectively implement and sustain a quality improvement program for SMP, the processes and tools for measuring outcomes need to be responsive, flexible and easily integrated into the organisation and delivery of programs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article undertakes a review of Australian and international literature and higher education policy in response to the changing nature of university academic boards (also known as academic senates or faculty senates). It shows that governance has become an issue for both the state and for universities and that within this context risk management and accountability mechanisms such as academic quality assurance are taking an increasingly prominent role. These developments have altered the form and function of academic governance and have fundamentally affected the academic board. For example, some literature reports that the role of Australian academic boards now largely revolves around academic quality assurance and it is argued that this is potentially problematic because of a focus on audit-driven accountability mechanisms. However, the article concludes by suggesting that as part of a broader quality assurance framework there is also an opportunity for academic boards to have a central role in the development of academic standards that focus on enhancing learning outcomes rather than on compliance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Enterprise Applications are complex software systems that manipulate much persistent data and interact with the user through a vast and complex user interface. In particular applications written for the Java 2 Platform, Enterprise Edition (J2EE) are composed using various technologies such as Enterprise Java Beans (EJB) or Java Server Pages (JSP) that in turn rely on languages other than Java, such as XML or SQL. In this heterogeneous context applying existing reverse engineering and quality assurance techniques developed for object-oriented systems is not enough. Because those techniques have been created to measure quality or provide information about one aspect of J2EE applications, they cannot properly measure the quality of the entire system. We intend to devise techniques and metrics to measure quality in J2EE applications considering all their aspects and to aid their evolution. Using software visualization we also intend to inspect to structure of J2EE applications and all other aspects that can be investigate through this technique. In order to do that we also need to create a unified meta-model including all elements composing a J2EE application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Commercial treatment planning systems employ a variety of dose calculation algorithms to plan and predict the dose distributions a patient receives during external beam radiation therapy. Traditionally, the Radiological Physics Center has relied on measurements to assure that institutions participating in the National Cancer Institute sponsored clinical trials administer radiation in doses that are clinically comparable to those of other participating institutions. To complement the effort of the RPC, an independent dose calculation tool needs to be developed that will enable a generic method to determine patient dose distributions in three dimensions and to perform retrospective analysis of radiation delivered to patients who enrolled in past clinical trials. Methods A multi-source model representing output for Varian 6 MV and 10 MV photon beams was developed and evaluated. The Monte Carlo algorithm, know as the Dose Planning Method (DPM), was used to perform the dose calculations. The dose calculations were compared to measurements made in a water phantom and in anthropomorphic phantoms. Intensity modulated radiation therapy and stereotactic body radiation therapy techniques were used with the anthropomorphic phantoms. Finally, past patient treatment plans were selected and recalculated using DPM and contrasted against a commercial dose calculation algorithm. Results The multi-source model was validated for the Varian 6 MV and 10 MV photon beams. The benchmark evaluations demonstrated the ability of the model to accurately calculate dose for the Varian 6 MV and the Varian 10 MV source models. The patient calculations proved that the model was reproducible in determining dose under similar conditions described by the benchmark tests. Conclusions The dose calculation tool that relied on a multi-source model approach and used the DPM code to calculate dose was developed, validated, and benchmarked for the Varian 6 MV and 10 MV photon beams. Several patient dose distributions were contrasted against a commercial algorithm to provide a proof of principal to use as an application in monitoring clinical trial activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Two patient-focused long-term research projects performed in the German outpatient psychotherapy system are focused on in this article. The TK (Techniker Krankenkasse) project is the first study to evaluate a quality assurance and feedback system with regard to its practical feasibility in German routine care. The other study (“Quality Assurance in Outpatient Psychotherapy in Bavaria”; QS-PSY-BAY) was designed to test a new approach for quality assurance in outpatient psychotherapy using electronic documentation of patient characteristics and outcome parameters. In addition this project provides the opportunity to analyze data on health-related costs for the patients undergoing outpatient psychotherapy. Method: Both projects and their results indicating high effect sizes are briefly described. Results: From the perspectives of the research teams, advisory boards and other stakeholders, the experiences with these projects are discussed focusing on obstacles, challenges, difficulties, and benefits in developing and implementing the studies. The triangle collaboration of therapists, researchers, and health insurance companies/health service institutions turned out to be fruitful in both studies. Conclusions: Despite some controversies between the partners the experiences indicate the importance of practiced-research collaborations to provide relevant information about the delivery of outpatient psychotherapy in the health system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of high-resolution CZE for determination of carbohydrate-deficient transferrin (CDT) in human serum based on internal and external quality data gathered over a 10-year period is reported. The assay comprises mixing of serum with a Fe(III) ion-containing solution prior to analysis of the iron saturated mixture in a dynamically double-coated capillary using a commercial buffer at alkaline pH. CDT values obtained with a human serum of a healthy individual and commercial quality control sera are shown to vary less than 10%. Values of a control from a specific lot were found to slowly decrease as function of time (less than 10% per year). Furthermore, due to unknown reasons, gradual changes in the monitored pattern around pentasialo-transferrin were detected, which limit the use of commercial control sera of the same lot to less than 2 years. Analysis of external quality control sera revealed correct classification of the samples over the entire 10-year period. Data obtained compare well with those of HPLC and CZE assays of other laboratories. The data gathered over a 10-year period demonstrate the robustness of the high-resolution CZE assay. This is the first account of a CZE-based CDT assay with complete internal and external quality assessment over an extended time period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Radiological Physics Center (RPC) uses both on-site and remote reviews to credential institutions for participation in clinical trials. Anthropomorphic quality assurance (QA) phantoms are one tool the RPC uses to remotely audit institutions, which include thermoluminescent dosimeters (TLDs) and radiochromic film. The RPC desires to switch from TLD as the absolute dosimeter in the phantoms, to optically stimulated luminescent dosimeters (OSLDs), but a problem lies in the angular dependence exhibited by the OSLD. The purpose of this study was to characterize the angular dependence of OSLD and establish a correction factor if necessary, to provide accurate dosimetric measurements as a replacement for TLD in the QA phantoms. A 10 cm diameter high-impact polystyrene spherical phantom was designed and constructed to hold an OSLD to study the angular response of the dosimeter under the simplest of circumstances for both coplanar and non-coplanar treatment deliveries. OSLD were irradiated in the spherical phantom, and the responses of the dosimeter from edge-on angles were normalized to the response when irradiated with the beam incident normally on the surface of the dosimeter. The average normalized response was used to establish an angular correction factor for 6 MV and 18 coplanar treatments, and for 6 MV non-coplanar treatments specific to CyberKnife. The RPC pelvic phantom dosimetry insert was modified to hold OSLD, in addition to the TLD, adjacent to the planes of film. Treatment plans of increasing angular beam delivery were developed, three in Pinnacle v9.0 (4-field box, IMRT, and VMAT) and one in Accuray’s MultiPlan v3.5.3 (CyberKnife). The plans were delivered to the pelvic phantom containing both TLD and OSLD in the target volume. The pelvic phantom was also sent to two institutions to be irradiated as trials, one delivering IMRT, and the other a CyberKnife treatment. For the IMRT deliveries and the two institution trials, the phantom also included film in the sagittal and coronal planes. The doses measured from the TLD and OSLD were calculated for each irradiation, and the angular correction factors established from the spherical phantom irradiations were applied to the OSLD dose. The ratio of the TLD dose to the angular corrected OSLD dose was calculated for each irradiation. The corrected OSLD dose was found to be within 1% of the TLD measured dose for all irradiations, with the exception of the in-house CyberKnife deliveries. The films were normalized to both TLD measured dose and the corrected OSLD dose. Dose profiles were obtained and gamma analysis was performed using a 7%/4 mm criteria, to compare the ability of the OSLD, when corrected for the angular dependence, to provide equivalent results to TLD. The results of this study indicate that the OSLD can effectively be used as a replacement for TLD in the RPC’s anthropomorphic QA phantoms for coplanar treatment deliveries when a correction is applied for the dosimeter’s angular dependence.