937 resultados para VALIDITY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The purposes of this study were to: 1) establish inter-instrument reliability between left and right hip accelerometer placement; 2) examine procedural reliability of a walking protocol used to measure physical activity (PA), and; 3) confirm concurrent validity of accelerometers in measuring PA intensity as compared to the gold standard of oxygen consumption measured by indirect calorimetry. METHODS Eight children (mean age: 11.9; SD: 3.2, 75% male) with CP (GMFCS levels I-III) wore ActiGraph GT3X accelerometers on each hip and the Cosmed K4b^{2} portable indirect calorimeter during two measurement sessions in which they performed the six minute walk test (6MWT) at three self-selected speeds (comfortable/slow, brisk, fast). Oxygen consumption (VO2) and accelerometer step and activity count data were recorded. RESULTS Inter-instrument reliability of ActiGraph GT3X accelerometers placed on left and right hips was excellent (ICC=0.96-0.99, CI_{95}: 0.81-0.99). Reproducibility of the protocol was good/excellent (ICC=0.75-0.95, CI_{95}: 0.75-0.98). Concurrent validity of accelerometer count data and VO2 was fair/good (rho=0.67, p< 0.001). The correlation between step count and VO2 was not significant (rho=0.29, p=0.2). CONCLUSION This preliminary research suggests that ActiGraph GT3X accelerometers are reliable and valid devices to monitor PA during walking in children with CP and may be appropriate in rehabilitation research and clinical practice. ActiGraph GTX3 step counts were not valid for this sample and further research is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: It is important to identify patients who are at risk of malnutrition upon hospital admission as malnutrition results in poor outcomes such as longer length of hospital stay, readmission, hospitalisation cost and mortality. The aim of this study was to determine the prognostic validity of 3-Minute Nutrition Screening (3-MinNS) in predicting hospital outcomes in patients admitted to an acute tertiary hospital through a list of diagnosis-related groups (DRG). Methods: In this study, 818 adult patients were screened for risk of malnutrition using 3-MinNS within 24 hours of admission. Mortality data was collected from the National Registry with other hospitalisation outcomes retrieved from electronic hospital records. The results were adjusted for age, gender and ethnicity, and matched for DRG. Results: Patients identified to be at risk of malnutrition (37%) using 3-MinNS had significant positive association with longer length of hospital stay (6.6 ± 7.1 days vs. 4.5 ± 5.5 days, p<0.001), higher hospitalisation cost (S$4540 ± 7190 vs. S$3630 ± 4961, p<0.001) and increased mortality rate at 1 year (27.8% vs. 3.9%), 2 years (33.8% vs. 7.2%) and 3 years (39.1% vs. 10.5%); p<0.001 for all. Conclusions: The 3-MinNS is able to predict clinical outcomes and can be used to screen newly admitted patients for nutrition risk so that appropriate nutrition assessment and early nutritional intervention can be initiated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment is a recurring theme in this issue of TESOL in Context. It is the focus of a themed section; addressed in some of the award-winning thesis research we feature; and one of several topics in an article on EFL teacher preparation in an Australian university. In the first section of the issue we are pleased to publish précis of the theses produced by the joint winners of the Penny McKay Memorial Award for Best Thesis in Language Education. Penny was a major figure in the development of EAL/D education in Australia (see Dooley & Moore, 2009). Her work is remembered and continued through an Award established by the Australian Council of TESOL Associations (ACTA) and the Applied Linguistics Association of Australia (ALAA). The award recognises doctoral research which makes an outstanding contribution to second/additional language education in Australian schools (http://www.tesol.org.au/About-ACTA/PENNY-MCKAY-MEMORIAL-FUND)...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood metaphors abound in everyday social discourse among both Aboriginal and non-Aboriginal people. However, ‘Aboriginal blood talk’, more specifically, is located within a contradictory and contested space in terms of the meanings and values that can be attributed to it by Aboriginal and non-Aboriginal people. In the colonial context, blood talk operated as a tool of oppression for Aboriginal people via blood quantum discourses, yet today, Aboriginal people draw upon notions of blood, namely bloodlines, in articulating their identities. This paper juxtaposes contemporary Aboriginal blood talk as expressed by Aboriginal people against colonial blood talk and critically examines the ongoing political and intellectual governance regarding the validity of this talk in articulating Aboriginalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite being used since 1976, Delusions-Symptoms-States-Inventory/states of Anxiety and Depression (DSSI/sAD) has not yet been validated for use among people with diabetes. The aim of this study was to examine the validity of the personal disturbance scale (DSSI/sAD) among women with diabetes using Mater-University of Queensland Study of Pregnancy (MUSP) cohort data. The DSSI subscales were compared against DSM-IV disorders, the Mental Component Score of the Short Form 36 (SF-36 MCS), and Center for Epidemiologic Studies Depression Scale (CES-D). Factor analyses, odds ratios, receiver operating characteristic (ROC) analyses and diagnostic efficiency tests were used to report findings. Exploratory factor analysis and fit indices confirmed the hypothesized two-factor model of DSSI/sAD. We found significant variations in the DSSI/sAD domain scores that could be explained by CES-D (DSSI-Anxiety: 55%, DSSI-Depression: 46%) and SF-36 MCS (DSSI-Anxiety: 66%, DSSI-Depression: 56%). The DSSI subscales predicted DSM-IV diagnosed depression and anxiety disorders. The ROC analyses show that although the DSSI symptoms and DSM-IV disorders were measured concurrently the estimates of concordance remained only moderate. The findings demonstrate that the DSSI/sAD items have similar relationships to one another in both the diabetes and non-diabetes data sets which therefore suggest that they have similar interpretations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The Spine Functional Index (SFI) is a patient reported outcome measure with sound clinimetric properties and clinical viability for the determination of whole-spine impairment. To date, no validated Turkish version is available. The purpose of this study is to cross-culturally adapted the SFI for Turkish-speaking patients (SFI-Tk) and determine the psychometric properties of reliability, validity and factor structure in a Turkish population with spine musculoskeletal disorders. Methods The SFI English version was culturally adapted and translated into Turkish using a double forward and backward method according to established guidelines. Patients (n = 285, cervical = l29, lumbar = 151, cervical and lumbar region = 5, 73% female, age 45 ± 1) with spine musculoskeletal disorders completed the SFI-Tk at baseline and after a seven day period for test-retest reliability. For criterion validity the Turkish version of the Functional Rating Index (FRI) was used plus the Neck Disability Index (NDI) for cervical patients and the Oswestry Disability Index (ODI) for back patients. Additional psychometric properties were determined for internal consistency (Chronbach’s α), criterion validity and factor structure. Results There was a high degree of internal consistency (α = 0.85, item range 0.80-0.88) and test-retest reliability (r = 0.93, item range = 0.75-0.95). The factor analysis demonstrated a one-factor solution explaining 24.2% of total variance. Criterion validity with the ODI was high (r = 0.71, p < 0.001) while the FRI and NDI were fair (r = 0.52 and r = 0.58, respectively). The SFI-Tk showed no missing responses with the ‘half-mark’ option used in 11.75% of total responses by 77.9% of participants. Measurement error from SEM and MDC90 were respectively 2.96% and 7.12%. Conclusions The SFI-Tk demonstrated a one-factor solution and is a reliable and valid instrument. The SFI-Tk consists of simple and easily understood wording and may be used to assess spine region musculoskeletal disorders in Turkish speaking patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The capacity to diagnosys, quantify and evaluate movement beyond the general confines of a clinical environment under effectiveness conditions may alleviate rampant strain on limited, expensive and highly specialized medical resources. An iPhone 4® mounted a three dimensional accelerometer subsystem with highly robust software applications. The present study aimed to evaluate the reliability and concurrent criterion-related validity of the accelerations with an iPhone 4® in an Extended Timed Get Up and Go test. Extended Timed Get Up and Go is a clinical test with that the patient get up from the chair and walking ten meters, turn and coming back to the chair. Methods A repeated measure, cross-sectional, analytical study. Test-retest reliability of the kinematic measurements of the iPhone 4® compared with a standard validated laboratory device. We calculated the Coefficient of Multiple Correlation between the two sensors acceleration signal of each subject, in each sub-stage, in each of the three Extended Timed Get Up and Go test trials. To investigate statistical agreement between the two sensors we used the Bland-Altman method. Results With respect to the analysis of the correlation data in the present work, the Coefficient of Multiple Correlation of the five subjects in their triplicated trials were as follows: in sub-phase Sit to Stand the ranged between r = 0.991 to 0.842; in Gait Go, r = 0.967 to 0.852; in Turn, 0.979 to 0.798; in Gait Come, 0.964 to 0.887; and in Turn to Stand to Sit, 0.992 to 0.877. All the correlations between the sensors were significant (p < 0.001). The Bland-Altman plots obtained showed a solid tendency to stay at close to zero, especially on the y and x-axes, during the five phases of the Extended Timed Get Up and Go test. Conclusions The inertial sensor mounted in the iPhone 4® is sufficiently reliable and accurate to evaluate and identify the kinematic patterns in an Extended Timed Get and Go test. While analysis and interpretation of 3D kinematics data continue to be dauntingly complex, the iPhone 4® makes the task of acquiring the data relatively inexpensive and easy to use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Depression is a common psychiatric disorder in older people. The study aimed to examine the screening accuracy of the Geriatric Depression Scale (GDS) and the Collateral Source version of the Geriatric Depression Scale (CS-GDS) in the nursing home setting. Methods Eighty-eight residents from 14 nursing homes were assessed for depression using the GDS and the CS-GDS, and validated against clinician diagnosed depression using the Semi-structured Clinical Diagnostic Interview for DSM-IV-TR Axis I Disorders (SCID) for residents without dementia and the Provisional Diagnostic Criteria for Depression in Alzheimer Disease (PDCdAD) for those with dementia. The screening performances of five versions of the GDS (30-, 15-, 10-, 8-, and 4-item) and two versions of the CS-GDS (30- and 15-item) were analyzed using receiver operating characteristic (ROC) curves. Results Among residents without dementia, both the self-rated (AUC = 0.75–0.79) and proxy-rated (AUC = 0.67) GDS variations performed significantly better than chance in screening for depression. However, neither instrument adequately identified depression among residents with dementia (AUC between 0.57 and 0.70). Among the GDS variations, the 4- and 8-item scales had the highest AUC and the optimal cut-offs were >0 and >3, respectively. Conclusions The validity of the GDS in detecting depression requires a certain level of cognitive functioning. While the CS-GDS is designed to remedy this issue by using an informant, it did not have adequate validity in detecting depression among residents with dementia. Further research is needed on informant selection and other factors that can potentially influence the validity of proxy-based measures in the nursing home setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Feeding practices are commonly examined as potentially modifiable determinants of children’s eating behaviours and weight status. Although a variety of questionnaires exist to assess different feeding aspects, many lack thorough reliability and validity testing. The Feeding Practices and Structure Questionnaire (FPSQ) is a tool designed to measure early feeding practices related to non-responsive feeding and structure of the meal environment. Face validity, factorial validity, internal reliability and cross-sectional correlations with children’s eating behaviours have been established in mothers with 2-year-old children. The aim of the present study was to further extend the validity of the FPSQ by examining factorial, construct and predictive validity, and stability. Methods Participants were from the NOURISH randomised controlled trial which evaluated an intervention with first-time mothers designed to promote protective feeding practices. Maternal feeding practices (FP) and child eating behaviours were assessed when children were aged 2 years and 3.7 years (n=388). Confirmatory Factor analysis, group differences, predictive relationships, and stability were tested. Results The original 9-factor structure was confirmed when children were aged 3.7±0.3 years. Cronbach’s alpha was above the recommended 0.70 cut-off for all factors except Structured Meal Timing, Over Restriction and Distrust in Appetite which were 0.58, 0.67 and 0.66 respectively. Allocated group differences reflected behaviour consistent with intervention content and all feeding practices were stable across both time points (range of r= 0.45-0.70). There was some evidence for the predictive validity of factors with 2 FP showing expected relationships, 2 FP showing expected and unexpected relationships and 5 FP showing no relationship. Conclusions Reliability and validity was demonstrated for most subscales of the FPSQ. Future validation is warranted with culturally diverse samples and with fathers and other caregivers. The use of additional outcomes to further explore predictive validity is recommended as well as testing construct validity and test-retest reliability of the questionnaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We commend Swanenburg et al. (2013) on translation, development, and clinimetric analysis of the NDI-G. However, the dual-factor structure with factor analysis and the high level of internal consistency (IC) highlighted in their discussion were not emphasized in the abstract or conclusion. These points may imply some inconsistencies with the final conclusions since determination of stable point estimates with the study's small sample are exceedingly difficult.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Body mass index (BMI) is used to diagnose obesity. However, its ability to predict the percentage fat mass (%FM) reliably is doubtful. Therefore validity of BMI as a diagnostic tool of obesity is questioned. Aim: This study is focused on determining the ability of BMI-based cut-off values in diagnosing obesity among Australian children of white Caucasian and Sri Lankan origin. Subjects and methods: Height and weight was measured and BMI (W/H2) calculated. Total body water was determined by deuterium dilution technique and fat free mass and hence fat mass derived using age- and gender-specific constants. A %FM of 30% for girls and 20% for boys was considered as the criterion cut-off level for obesity. BMI-based obesity cut-offs described by the International Obesity Task Force (IOTF), CDC/NCHS centile charts and BMI-Z were validated against the criterion method. Results: There were 96 white Caucasian and 42 Sri Lankan children. Of the white Caucasians, 19 (36%) girls and 29 (66%) boys, and of the Sri Lankans 7 (46%) girls and 16 (63%) boys, were obese based on %FM. The FM and BMI were closely associated in both Caucasians (r = 0.81, P<0.001) and Sri Lankans (r = 0.92, P<0.001). Percentage FM and BMI also had a lower but significant association. Obesity cut-off values recommended by IOTF failed to detect a single case of obesity in either group. However, NCHS and BMI-Z cut-offs detected cases of obesity with low sensitivity. Conclusions: BMI is a poor indicator of percentage fat and the commonly used cut-off values were not sensitive enough to detect cases of childhood obesity in this study. In order to improve the diagnosis of obesity, either BMI cut-off values should be revised to increase the sensitivity or the possibility of using other indirect methods of estimating the %FM should be explored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to determine the reliability of body mass index based (BMI) cutoff values in diagnosing obesity among Sri Lankan children. Height, weight, waist circumference (WC) and hip circumference (HC) in 282 children were measured. Total body water was determined by deuterium dilution and fat mass (FM) derived using age and gender specific constants. A percentage FM of 30% for girls and 25% for boys were considered as cutoff levels for obesity. Two hundred and eighty two children (M/F: 158/124) were studied and 99 (80%) girls and 72 (45.5%) boys were obese based on % body fat. Eight (6.4%) girls and nine (5.7%) boys were obese based on International Obesity Task Force (IOTF) cutoff values. Percentage FM and WC centile charts were able to diagnose a significant proportion of children as true obese children. The FM and BMI were closely associated in both girls (r = 0.82, p < 0.001) and boys (r = 0.87, p < 0.001). Percentage FM and BMI had a very low but significant association; girls (r = 0.32, p < 0.001) and boys (r = 0.68, p < 0.001). FM had a significant association with WC and HC. BMI based cutoff values had a specificity of 100% but a very low sensitivity, varying between 8% and 23.6%. BMI is a poor indicator of the percentage fat and the commonly used cutoff values were not sensitive to detect cases of childhood obesity in Sri Lankan children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the dimensional reduction regularization scheme, we show that radiative corrections to the anomaly of the axial current, which is coupled to the gauge field, are absent in a supersymmetric U(1) gauge model for both 't Hooft-Veltman and Bardeen prescriptions for γ5. We also discuss the results with reference to conventional dimensional regularization. This result has significant implications with respect to the renormalizability of supersymmetric models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Physical therapy for youth with cerebral palsy (CP) who are ambulatory includes interventions to increase functional mobility and participation in physical activity (PA). Thus, reliable and valid measures are needed to document PA in youth with CP. OBJECTIVE The purpose of this study was to evaluate the inter-instrument reliability and concurrent validity of 3 accelerometer-based motion sensors with indirect calorimetry as the criterion for measuring PA intensity in youth with CP. METHODS Fifty-seven youth with CP (mean age=12.5 years, SD=3.3; 51% female; 49.1% with spastic hemiplegia) participated. Inclusion criteria were: aged 6 to 20 years, ambulatory, Gross Motor Function Classification System (GMFCS) levels I through III, able to follow directions, and able to complete the full PA protocol. Protocol activities included standardized activity trials with increasing PA intensity (resting, writing, household chores, active video games, and walking at 3 self-selected speeds), as measured by weight-relative oxygen uptake (in mL/kg/min). During each trial, participants wore bilateral accelerometers on the upper arms, waist/hip, and ankle and a portable indirect calorimeter. Intraclass coefficient correlations (ICCs) were calculated to evaluate inter-instrument reliability (left-to-right accelerometer placement). Spearman correlations were used to examine concurrent validity between accelerometer output (activity and step counts) and indirect calorimetry. Friedman analyses of variance with post hoc pair-wise analyses were conducted to examine the validity of accelerometers to discriminate PA intensity across activity trials. RESULTS All accelerometers exhibited excellent inter-instrument reliability (ICC=.94-.99) and good concurrent validity (rho=.70-.85). All accelerometers discriminated PA intensity across most activity trials. LIMITATIONS This PA protocol consisted of controlled activity trials. CONCLUSIONS Accelerometers provide valid and reliable measures of PA intensity among youth with CP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim This study evaluated the validity of the OMNI Walk/Run Rating of Perceived Exertion (OMNI-RPE) scores with heart rate and oxygen consumption (VO2) for children and adolescents with cerebral palsy (CP). Method Children and adolescents with CP, aged 6 to 18 years and Gross Motor Function Classification System (GMFCS) levels I to III completed a physical activity protocol with seven trials ranging in intensity from sedentary to moderate-to-vigorous. VO2 and heart rate were recorded during the physical activity trials using a portable indirect calorimeter and heart rate monitor. Participants reported OMNI-RPE scores for each trial. Concurrent validity was assessed by calculating the average within-subject correlation between OMNI-RPE ratings and the two physiological indices. Results For the correlational analyses, 48 participants (22 males, 26 females; age 12y 6mo, SD 3y 4mo) had valid bivariate data for VO2 and OMNI-RPE, while 40 participants (21 males, 19 females; age 12y 5mo, SD 2y 9mo) had valid bivariate data for heart rate and OMNI-RPE. VO2 (r=0.80; 95% CI 0.66–0.88) and heart rate (r=0.83; 95% CI 0.70–0.91) were moderately to highly correlated to OMNI-RPE scores. No difference was found for the correlation of physiological data and OMNI-RPE scores across the three GMFCS levels. The OMNI-RPE scores increased significantly in a dose-response manner (F6,258=116.1, p<0.001) as exercise intensity increased from sedentary to moderate-to-vigorous. Interpretation OMNI-RPE is a clinically feasible option to monitor exercise intensity in ambulatory children and adolescents with CP.