961 resultados para Total Artificial Heart


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow-balancing Starling response is diminished in both ventricles. The reliability of sensor and sensor-less based control systems which aim to control VAD flow based on preload have limitations and thus an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a compliant inflow cannula could potentially be used as a passive control system to prevent suction events in rotary left, right and biventricular support.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study was a step forward in modeling, simulation and microcontroller implementation of a high performance control algorithm for the motor of a blood pump. The rotor angle is sensed using three Hall effect sensors and an algorithm is developed to obtain better angular resolution from the three signals for better discrete-time updates of the controller. The performance of the system was evaluated in terms of actual and reference speeds, stator currents and power consumption over a range of reference speeds up to 4000 revolutions per minute. The use of fewer low cost Hall effect sensors compared to expensive high resolution sensors could reduce the cost of blood pumps for total artificial hearts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Computational fluid dynamics (CFD) and particle image velocimetry (PIV) are commonly used techniques to evaluate the flow characteristics in the development stage of blood pumps. CFD technique allows rapid change to pump parameters to optimize the pump performance without having to construct a costly prototype model. These techniques are used in the construction of a bi-ventricular assist device (BVAD) which combines the functions of LVAD and RVAD in a compact unit. The BVAD construction consists of two separate chambers with similar impellers, volutes, inlet and output sections. To achieve the required flow characteristics of an average flow rate of 5 l/min and different pressure heads (left – 100mmHg and right – 20mmHg), the impellers were set at different rotating speeds. From the CFD results, a six-blade impeller design was adopted for the development of the BVAD. It was also observed that the fluid can flow smoothly through the pump with minimum shear stress and area of stagnation which are related to haemolysis and thrombosis. Based on the compatible Reynolds number the flow through the model was calculated for the left and the right pumps. As it was not possible to have both the left and right chambers in the experimental model, the left and right pumps were tested separately.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Animal models of critical illness are vital in biomedical research. They provide possibilities for the investigation of pathophysiological processes that may not otherwise be possible in humans. In order to be clinically applicable, the model should simulate the critical care situation realistically, including anaesthesia, monitoring, sampling, utilising appropriate personnel skill mix, and therapeutic interventions. There are limited data documenting the constitution of ideal technologically advanced large animal critical care practices and all the processes of the animal model. In this paper, we describe the procedure of animal preparation, anaesthesia induction and maintenance, physiologic monitoring, data capture, point-of-care technology, and animal aftercare that has been successfully used to study several novel ovine models of critical illness. The relevant investigations are on respiratory failure due to smoke inhalation, transfusion related acute lung injury, endotoxin-induced proteogenomic alterations, haemorrhagic shock, septic shock, brain death, cerebral microcirculation, and artificial heart studies. We have demonstrated the functionality of monitoring practices during anaesthesia required to provide a platform for undertaking systematic investigations in complex ovine models of critical illness.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A anestesia peridural é amplamente difundida no meio veterinário, utilizando-se o anestésico local isolado ou associado aos opióides, capazes de promover aumento do efeito analgésico. O objetivo deste estudo foi avaliar a função cardiorrespiratória e analgésica da ropivacaína isolada ou associada ao fentanil ou tramadol. Para tanto, oito cães foram tranqüilizados com acepromazina, submetidos à anestesia peridural com um dos seguintes protocolos: GR (ropivacaína), GRF (ropivacaína + fentanil), GRT (ropivacaína + tramadol), em volume total de 0,25ml kg-1, e foram avaliados os parâmetros: freqüência cardíaca e respiratória, temperatura retal, pressão arterial sistólica, e gasometria do sangue arterial, os bloqueios sensitivo e motor, o grau de sedação e a ocorrência de possíveis efeitos indesejáveis. A diminuição da freqüência cardíaca nos grupos GRF e GRT foi mais intensa e ocorreu hipotermia significativa no GRF. Foi evidenciada sedação severa em GRF e GRT. O período de recuperação foi mais curto nos animais de GRT. O GRT foi o grupo que apresentou bloqueio mais cranial. Foram observadas bradicardia, hipotermia e síndrome de Shiff-Sherrington no período trans-anestésico em animais de todos os grupos. Nas 24 horas de período pós-anestésico, não foram evidenciados efeitos indesejáveis nos grupos. O GRF apresentou maior duração de anestesia e analgesia, enquanto que o GRT apresentou a menor duração de anestesia com analgesia intermediária e o GR apresentou duração intermediária, com menor analgesia. Não foram encontradas alterações respiratórias e hemogasométricas, porém, bradicardia, hipotermia e síndrome de Schiff-Sherrington, alterações trans-anestésicas comuns na anestesia peridural foram encontradas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Research for new biocompatible and easily implantable materials continuously proposes new molecules and new substances with biological, chemical and physical characteristics, that are more and more adapted to aesthetic and reconstructive surgery and to the development of biomedical devices such as cardiovascular prostheses. Two classes of polymeric biomaterials seem to meet better these requirements: “hydrogels” , which includes polyalkylimide (PAI) and polyvinylalcohol (PVA) and “elastomers”, which includes polyurethanes (PUs). The first ones in the last decade have had a great application for soft tissue augmentation, due to their similarity to this tissue for their high water content, elasticity and oxygen permeability (Dini et al., 2005). The second ones, on the contrary, are widely used in cardiovascular applications (catheters, vascular grafts, ventricular assist devices, total artificial hearts) due to their good mechanical properties and hemocompatibility (Zdrahala R.J. and Zdrahala I.J., 1999). In the biocompatibility evaluation of these synthetic polymers, that is important for its potential use in clinical applications, a fundamental aspect is the knowledge of the polymers cytotoxicity and the effect of their interaction with cells, in particular with the cell populations involved in the inflammatory responses, i.e. monocyte/macrophages. In consideration of what above said, the aim of this study is the comprehension of the in vitro effect of PAI, PVA and PU on three cell lines that represent three different stages of macrophagic differentiation: U937 pro-monocytes, THP-1 monocytes and RAW 264.7 macrophages. Cytotoxicity was evaluated by measuring the rate of viability with MTT, Neutral Red and morphological analysis at light microscope in time-course dependent experiments. The influence of these polymers on monocyte/macrophage activation in terms of cells adhesion, monocyte differentiation in macrophages, antigens distribution, aspecific phagocytosis, fluid-phase endocitosis, pro-inflammatory cytokine (TNF-α, IL-1β, IL-6) and nitric oxide (NO) release was evaluated. In conclusion, our studies have indicated that the three different polymeric biomaterials are highly biocompatible, since they scarcely affected viability of U937, THP-1 and RAW 264.7 cells. Moreover, we have found that even though hydrogels and polyurethane influences monocyte/macrophage differentiation (depending on the particular type of cell and polymer), they are immunocompatible since they not induced significantly high cytokine release. For these reasons their clinical applications are strongly encouraged.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) and total artificial hearts have been in development for the last 50 years. Since their inception, simulators of the circulation with different degrees of complexity have been produced to test these devices in vitro. Currently, a new path has been taken with the extensive efforts to develop paediatric VADs, which require totally different design constraints. This paper presents the manufacturing details of an economical simulator of the systemic paediatric circulation. This simulator allows the insertion of a paediatric VAD, includes a pumping ventricle, and is adjustable within the paediatric range. Rather than focusing on complexity and physiological simulation, this simulator is designed to be simple and practical for rapid device testing. The simulator was instrumented with medical sensors and data were acquired under different conditions with and without the new PediaFlowTM paediatric VAD. The VAD was run at different impeller speeds while simulator settings such as vascular resistance and stroke volume were varied. The hydraulic performance of the VAD under pulsatile conditions could be characterized and the magnetic suspension could be tested via manipulations such as cannula clamping. This compact mock loop has proven to be valuable throughout the PediaFlow development process and has the advantage that it is uncomplicated and can be manufactured cheaply. It can be produced by several research groups and the results of different VADs can then be compared easily.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Staphylococcus epidermidis causes infections associated with medical devices including central venous catheters, orthopaedic prosthetic joints and artificial heart valves. This coagulase-negative Staphylococcus produces a conventional cellular lipoteichoic acid (LTA) and also releases a short-glycerophosphate-chain-length form of LTA (previously termed lipid S) into the medium during growth. The relative pro-inflammatory activities of cellular and short-chain-length exocellular LTA were investigated in comparison with peptidoglycan and wall teichoic acid from S. epidermidis and LPS from Escherichia coli O111. The ability of these components to stimulate the production of proinflammatory cytokines [interleukin (IL)-1β, IL-6 and tumour necrosis factor (TNF)-α] and nitric oxide was investigated in a murine macrophage-like cell line (J774.2), and in peritoneal and splenic macrophages. On a weight-for-weight basis the short-chain-length exocellular LTA was the most active of the S. epidermidis products, stimulating significant amounts of each of the inflammatory cytokines and nitric oxide, although it was approximately 100-fold less active than LPS from E. coli. By comparison the full-chain-length cellular LTA and peptidoglycan were less active and the wall teichoic acid had no activity. As an exocellular product potentially released from S. epidermidis biofilms, the short-chain-length exocellular LTA may act as the prime mediator of the host inflammatory response to device-related infection by this organism and act as the Gram-positive equivalent of LPS in Gram-negative sepsis. The understanding of the role of short-chain-length exocellular LTA in Gram-positive sepsis may lead to improved treatment strategies. © 2005 SGM.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Several studies have suggested that men with raised plasma triglycerides (TGs) in combination with adverse levels of other lipids may be at special risk of subsequent ischemic heart disease (IHD). We examined the independent and combined effects of plasma lipids at 10 years of follow-up. We measured fasting TGs, total cholesterol (TC), and high density lipoprotein cholesterol (HDLC) in 4362 men (aged 45 to 63 years) from 2 study populations and reexamined them at intervals during a 10-year follow-up. Major IHD events (death from IHD, clinical myocardial infarction, or ECG-defined myocardial infarction) were recorded. Five hundred thirty-three major IHD events occurred. All 3 lipids were strongly and independently predictive of IHD after 10 years of follow-up. Subjects were then divided into 27 groups (ie, 33) by the tertiles of TGs, TC, and HDLC. The number of events observed in each group was compared with that predicted by a logistic regression model, which included terms for the 3 lipids (without interactions) and potential confounding variables. The incidence of IHD was 22.6% in the group with the lipid risk factor combination with the highest expected risk (high TGs, high TC, and low HDLC) and 4.7% in the group with the lowest expected risk (P

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recently, genome wide association studies (GWAS) have identified a number of single nucleotide polymorphisms (SNPs) as being associated with coronary heart disease (CHD). We estimated the effect of these SNPs on incident CHD, stroke and total mortality in the prospective cohorts of the MORGAM Project. We studied cohorts from Finland, Sweden, France and Northern Ireland (total N=33,282, including 1,436 incident CHD events and 571 incident stroke events). The lead SNPs at seven loci identified thus far and additional SNPs (in total 42) were genotyped using a case-cohort design.We estimated the effect of the SNPs on disease history at baseline, disease events during follow-up and classic risk factors. Multiple testing was taken into account using false discovery rate (FDR) analysis. SNP rs1333049 on chromosome 9p21.3 was associated with both CHD and stroke (HR5=.20, 95% CI 1.08-1.34 for incident CHD events and 1.15, 0.99-1.34 for incident stroke). SNP rs11670734 (19q12) was associated with total mortality and stroke. SNP rs2146807 (10q11.21) showed some association with the fatality of acute coronary event. SNP rs2943634 (2q36.3) was associated with high density lipoprotein (HDL) cholesterol and SNPs rs599839, rs4970834 (1p13.3) and rs17228212 (15q22.23) were associated with non-HDL cholesterol. SNPs rs2943634 (2q36.3) and rs12525353 (6q25.1) were associated with blood pressure. These findings underline the need for replication studies in prospective settings and confirm the candidacy of several SNPs that may play a role in the etiology of cardiovascular disease.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report the discovery and characterization of a deeply eclipsing AM CVn-system, Gaia14aae (=ASSASN-14cn). Gaia14aae was identified independently by the All-Sky Automated Survey for Supernovae (ASAS-SN; Shappee et al.) and by the Gaia Science Alerts project, during two separate outbursts. A third outburst is seen in archival Pan-STARRS-1 (PS1; Schlafly et al.; Tonry et al.; Magnier et al.) and ASAS-SN data. Spectroscopy reveals a hot, hydrogen-deficient spectrum with clear double-peaked emission lines, consistent with an accreting double-degenerate classification. We use follow-up photometry to constrain the orbital parameters of the system. We find an orbital period of 49.71 min, which places Gaia14aae at the long period extremum of the outbursting AM CVn period distribution. Gaia14aae is dominated by the light from its accreting white dwarf (WD). Assuming an orbital inclination of 90° for the binary system, the contact phases of the WD lead to lower limits of 0.78 and 0.015 M⊙ on the masses of the accretor and donor, respectively, and a lower limit on the mass ratio of 0.019. Gaia14aae is only the third eclipsing AM CVn star known, and the first in which the WD is totally eclipsed. Using a helium WD model, we estimate the accretor's effective temperature to be 12 900 ± 200 K. The three outburst events occurred within four months of each other, while no other outburst activity is seen in the previous 8 yr of Catalina Real-time Transient Survey (CRTS; Drake et al.), Pan-STARRS-1 and ASAS-SN data. This suggests that these events might be rebrightenings of the first outburst rather than individual events.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: In previous studies cholesterol-rich nanoemulsions (LDE) resembling low-density lipoprotein were shown to concentrate in atherosclerotic lesions of rabbits. Lesions were pronouncedly reduced by treatment with paclitaxel associated with LDE. This study aimed to test the hypothesis of whether LDE-paclitaxel is able to concentrate in grafted hearts of rabbits and to ameliorate coronary allograft vasculopathy after the transplantation procedure. Methods: Twenty-one New Zealand rabbits fed 0.5% cholesterol were submitted to heterotopic heart transplantation at the cervical position. All rabbits undergoing transplantation were treated with cyclosporin A (10 mg . kg(-1) . d(-1) by mouth). Eleven rabbits were treated with LDE-paclitaxel (4 mg/kg body weight paclitaxel per week administered intravenously for 6 weeks), and 10 control rabbits were treated with 3 mL/wk intravenous saline. Four control animals were injected with LDE labeled with [(14)C]-cholesteryl oleate ether to determine tissue uptake. Results: Radioactive LDE uptake by grafts was 4-fold that of native hearts. In both groups the coronary arteries of native hearts showed no stenosis, but treatment with LDE-paclitaxel reduced the degree of stenosis in grafted hearts by 50%. The arterial luminal area in grafts of the treated group was 3-fold larger than in control animals. LDE-paclitaxel treatment resulted in a 7-fold reduction of macrophage infiltration. In grafted hearts LDE-paclitaxel treatment reduced the width of the intimal layer and inhibited the destruction of the medial layer. No toxicity was observed in rabbits receiving LDE-paclitaxel treatment. Conclusions: LDE-paclitaxel improved posttransplantation injury to the grafted heart. The novel therapeutic approach for heart transplantation management validated here is thus a promising strategy to be explored in future clinical studies. (J Thorac Cardiovasc Surg 2011;141:1522-8)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background :
The correlations between systolic blood pressure (SBP) and total cholesterol levels (CHOL) might result from genetic or environmental factors that determine variation in the phenotypes and are shared by family members. Based on 330 nuclear families in the Framingham Heart Study, we used a multivariate normal model, implemented in the software FISHER, to estimate genetic and shared environmental components of variation and genetic and shared environmental correlation between the phenotypes. The natural logarithm of the phenotypes measured at the last visit in both Cohort 1 and 2 was used in the analyses. The antihypertensive treatment effect was corrected before adjustment of the systolic blood pressure for age, sex, and cohort.
Results :
The univariate correlation coefficient was statistically significant for sibling pairs and parent-offspring pairs, but not significant for spouse pairs. In the bivariate analysis, the cross-trait correlation coefficients were not statistically significant for all relative pairs. The shared environmental correlation was statistically significant, but the genetic correlation was not significant.
Conclusion :
There is no significant evidence for a close genetic correlation between systolic blood pressure and total cholesterol levels. However, some shared environmental factors may determine the variation of both phenotypes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O trabalho foi desenvolvido na U.P.A. “Senador Álvaro Adolpho”, Embrapa Amazônia Oriental, Belém, Pará (1º25¢ S 48º26¢ O), local de tipo climático Afi (quente e úmido). O objetivo foi avaliar o uso de sistemas silvipastoris (SSP) como ferramenta de manejo para proporcionar maior conforto térmico a búfalas leiteiras, e incrementar sua eficiência reprodutiva após a utilização da inseminação artificial em tempo fixo. Foram utilizados dois SSP´s, durante dois períodos do ano, onde: Período 1 (Abril a Junho), com maior precipitação pluviométrica e Período 2 (Setembro a Novembro), com menor precipitação pluviométrica. Foram mensuradas a freqüência cardíaca (FC), freqüência respiratória (FR), temperatura retal (TR) e movimentos ruminais (MR), sempre às 9h00min. O índice de conforto animal foi calculado conforme a fórmula: ICA = TR/38,33 + FR/23. Os animais de cada sistema foram tratados com dois diferentes protocolos para sincronização do estro e ovulação, formando os Grupos SSP 1/Ovsynch, SSP 2/Ovsynch (estro sincronizado com Ovsynch), SSP 1/Prog e SSP 2/Prog (estro sincronizado com Ovsynch + 1g de progesterona intravaginal). Os ovários de todas as búfalas foram monitorados por ultra-sonografia no D0, D7 e D9 e as búfalas foram inseminadas no D10 (D0=dia do início da sincronização). As médias de FC foram de 57,35±8,24 bat/min no Período 1 e 62,48 ±7,79 bat/min no Período 2 (P<0,01). A FR média foi de 25,66 ±10,53 mov/min no Período 1 e de 33,38 ±18,23 mov/min no Período 2 (P<0,01). Os animais mantidos no SSP 1 apresentaram TR superior aos do SSP 2 (39,02 ±0,53ºC versus 38,65 ±0,41ºC, P<0,01). As médias do ICA variaram entre 1,89 e 3,55. No Período 1 obteve-se variação de 1,89 a 2,42 e média de 2,12 ±0,46. No Período 2, a média do ICA foi de 2,46 ±0,79, com variação de 1,91 a 3,55. Houve diferença significativa das médias de ICA entre os períodos (P<0,01). O diâmetro do folículo dominante no D9 foi superior para os animais que receberam progesterona (10,40 ±1,22 mm versus 12,21 ±3,42 mm; P=0,05). A taxa de prenhez total foi de 48,21%, sendo que no Período 1 houve 56,66% de fêmeas gestantes, contra 38,46% no Período 2 (SSP1/Ovsynch: 40,0%; SSP2/Ovsynch: 38,46%; SSP1/Prog: 46,66% e SSP2/Prog: 69,23%; P>0,05). Com base nos resultados, ressalta-se a importância do manejo do ambiente físico para a criação de bubalinos na Amazônia Oriental, o que pode evitar gastos energéticos para a termorregulação animal e possibilitar melhores índices reprodutivos.