212 resultados para metered dose inhaler, nebulizer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite increasing life expectancy, the age of onset of natural menopause has not significantly changed in recent decades. Thus, women spend about one-third of their lives in an estrogen-deficient state if untreated. There is a need for appropriate treatment of acute symptoms and prevention of the sequelae of chronic estrogen deficiency. International guidelines call for the use of the lowest effective hormone dosage for vasomotor symptom relief, the major indication for menopausal hormone therapy (MHT). In 2011, an oral continuous combined ultra-low-dose MHT was approved in Switzerland. This publication was elaborated by eight national menopause specialists and intends to review the advantages and disadvantages of ultra-low-dose MHT after the first years of its general use in Switzerland. It concludes that, for many women, ultra-low-dose MHT may be sufficient to decrease vasomotor symptoms, but not necessarily to guarantee fracture prevention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In clinical practise the high dose ACTH stimulation test (HDT) is frequently used in the assessment of adrenal insufficiency (AI). However, there is uncertainty regarding optimal time-points and number of blood samplings. The present study compared the utility of a single cortisol value taken either 30 or 60 minutes after ACTH stimulation with the traditional interpretation of the HDT. METHODS: Retrospective analysis of 73 HDT performed at a single tertiary endocrine centre. Serum cortisol was measured at baseline, 30 and 60 minutes after intravenous administration of 250 µg synthetic ACTH1-24. Adrenal insufficiency (AI) was defined as a stimulated cortisol level <550 nmol/l. RESULTS: There were twenty patients (27.4%) who showed an insufficient rise in serum cortisol using traditional HDT criteria and were diagnosed to suffer from AI. There were ten individuals who showed insufficient cortisol values after 30 minutes, rising to sufficient levels at 60 minutes. All patients revealing an insufficient cortisol response result after 60 minutes also had an insufficient result after 30 minutes. The cortisol value taken after 30 minutes did not add incremental diagnostic value in any of the cases under investigation compared with the 60 minutes' sample. CONCLUSIONS: Based on the findings of the present analysis the utility of a cortisol measurement 30 minutes after high dose ACTH injection was low and did not add incremental diagnostic value to a single measurement after 60 minutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND High-dose benzodiazepine (BZD) dependence is associated with a wide variety of negative health consequences. Affected individuals are reported to suffer from severe mental disorders and are often unable to achieve long-term abstinence via recommended discontinuation strategies. Although it is increasingly understood that treatment interventions should take subjective experiences and beliefs into account, the perceptions of this group of individuals remain under-investigated. METHODS We conducted an exploratory qualitative study with 41 adult subjects meeting criteria for (high-dose) BZD-dependence, as defined by ICD-10. One-on-one in-depth interviews allowed for an exploration of this group's views on the reasons behind their initial and then continued use of BZDs, as well as their procurement strategies. Mayring's qualitative content analysis was used to evaluate our data. RESULTS In this sample, all participants had developed explanatory models for why they began using BZDs. We identified a multitude of reasons that we grouped into four broad categories, as explaining continued BZD use: (1) to cope with symptoms of psychological distress or mental disorder other than substance use, (2) to manage symptoms of physical or psychological discomfort associated with somatic disorder, (3) to alleviate symptoms of substance-related disorders, and (4) for recreational purposes, that is, sensation-seeking and other social reasons. Subjects often considered BZDs less dangerous than other substances and associated their use more often with harm reduction than as recreational. Specific obtainment strategies varied widely: the majority of participants oscillated between legal and illegal methods, often relying on the black market when faced with treatment termination. CONCLUSIONS Irrespective of comorbidity, participants expressed a clear preference for medically related explanatory models for their BZD use. We therefore suggest that clinicians consider patients' motives for long-term, high-dose BZD use when formulating treatment plans for this patient group, especially since it is known that individuals are more compliant with approaches they perceive to be manageable, tolerable, and effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radiation dose rates at flight altitudes can increase by orders of magnitude for a short time during energetic solar cosmic ray events, so called ground level enhancements (GLEs). Especially at high latitudes and flight altitudes, solar energetic particles superposed on galactic cosmic rays may cause radiation that exceeds the maximum allowed dosage limit for the general public. Therefore the determination of the radiation dose rate during GLEs should be as reliable as possible. Radiation dose rates along flight paths are typically determined by computer models that are based on cosmic ray flux and anisotropy parameters derived from neutron monitor and/or satellite measurements. The characteristics of the GLE on 15 April 2001 (GLE60) were determined and published by various authors. In this work we compare these results and investigate the consequences on the computed radiation dose rates along selected flight paths. In addition, we compare the computed radiation dose rates with measurements that were made during GLE60 on board two transatlantic flights.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Cochlear implants (CI) are standard treatment for prelingually deafened children and postlingually deafened adults. Computed tomography (CT) is the standard method for postoperative imaging of the electrode position. CT scans accurately reflect electrode depth and position, which is essential prior to use. However, routine CT examinations expose patients to radiation, which is especially problematic in children. We examined whether new CT protocols could reduce radiation doses while preserving diagnostic accuracy. METHODS To investigate whether electrode position can be assessed by low-dose CT protocols, a cadaveric lamb model was used because the inner ear morphology is similar to humans. The scans were performed at various volumetric CT dose-indexes CTDIvol)/kV combinations. For each constant CTDIvol the tube voltage was varied (i.e., 80, 100, 120 and 140kV). This procedure was repeated at different CTDIvol values (21mGy, 11mGy, 5.5mGy, 2.8mGy and 1.8mGy). To keep the CTDIvol constant at different tube voltages, the tube current values were adjusted. Independent evaluations of the images were performed by two experienced and blinded neuroradiologists. The criteria diagnostic usefulness, image quality and artifacts (scaled 1-4) were assessed in 14 cochlear-implanted cadaveric lamb heads with variable tube voltages. RESULTS Results showed that the standard CT dose could be substantially reduced without sacrificing diagnostic accuracy of electrode position. The assessment of the CI electrode position was feasible in almost all cases up to a CTDIvol of 2-3mGy. The number of artifacts did not increase for images within this dose range as compared to higher dosages. The extent of the artifacts caused by the implanted metal-containing CI electrode does not depend on the radiation dose and is not perceptibly influenced by changes in the tube voltage. Summarizing the evaluation of the CI electrode position is possible even at a very low radiation dose. CONCLUSIONS CT imaging of the temporal bone for postoperative electrode position control of the CI is possible with a very low and significantly radiation dose. The tube current-time product and voltage can be reduced by 50% without increasing artifacts. Low-dose postoperative CT scans are sufficient for localizing the CI electrode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Standard dose of external beam radiotherapy seems to be insufficient for satisfactory control of loco-regionally advanced cervical cancer. Aim of our study is to evaluate the outcome as well as early and chronic toxicities in patients with loco-regionally advanced cervical cancer, treated with dose escalated intensity modulated radiotherapy (IMRT) combined with cisplatin chemotherapy. MATERIAL AND METHODS Thirty-nine patients with cervical carcinoma FIGO stage IB2 - IVA were treated with curative intent between 2006 and 2010. The dose of 50.4 Gy was prescribed to the elective pelvic nodal volume. Primary tumors < 4 cm in diameter (n = 6; 15.4 %) received an external beam radiotherapy (EBRT) boost of 5.4 Gy, primary tumors > 4 cm in diameter (n = 33; 84.6 %) received an EBRT boost of 9 Gy. Patients with positive lymph nodes detected with (18)FDG-PET/CT (n = 22; 56.4 %) received a boost to a total dose of 59.4 - 64.8 Gy. The para-aortic region was included in the radiation volume in 8 (20.5 %) patients and in 5 (12.8 %) patients the para-aortic macroscopic lymph nodes received an EBRT boost. IMRT was followed with a 3D planned high dose rate intrauterine brachytherapy given to 36 (92.3 %) patients with a total dose ranging between 15-18 Gy in three fractions (single fraction: 4-6.5 Gy). Patients without contraindications (n = 31/79.5 %) received concomitantly a cisplatin-based chemotherapy (40 mg/kg) weekly. Toxicities were graded according to the common terminology criteria for adverse events (CTCAE v 4.0). RESULTS Mean overall survival for the entire cohort was 61.1 months (±3.5 months). Mean disease free survival was 47.2 months (±4.9 months) and loco-regional disease free survival was 55.2 months (±4.4 months). 65 % of patients developed radiotherapy associated acute toxicities grade 1, ca. 30 % developed toxicities grade 2 and just two (5.2 %) patients developed grade 3 toxicities, one acute diarrhea and one acute cystitis. 16 % of patients had chronic toxicities grade 1, 9 % grade 2 and one patient (2.6 %) toxicities grade 3 in the form of vaginal dryness. CONCLUSION Dose escalated IMRT appears to have a satisfactory outcome with regards to mean overall survival, disease free and loco-regional disease free survival, whereas the treatment-related toxicities remain reasonably low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Results on mitochondrial dysfunction in sepsis are controversial. We aimed to assess effects of LPS at wide dose and time ranges on hepatocytes and isolated skeletal muscle mitochondria. METHODS Human hepatocellular carcinoma cells (HepG2) were exposed to placebo or LPS (0.1, 1, and 10 μg/mL) for 4, 8, 16, and 24 hours and primary human hepatocytes to 1 μg/mL LPS or placebo (4, 8, and 16 hours). Mitochondria from porcine skeletal muscle samples were exposed to increasing doses of LPS (0.1-100 μg/mg) for 2 and 4 hours. Respiration rates of intact and permeabilized cells and isolated mitochondria were measured by high-resolution respirometry. RESULTS In HepG2 cells, LPS reduced mitochondrial membrane potential and cellular ATP content but did not modify basal respiration. Stimulated complex II respiration was reduced time-dependently using 1 μg/mL LPS. In primary human hepatocytes, stimulated mitochondrial complex II respiration was reduced time-dependently using 1 μg/mL LPS. In isolated porcine skeletal muscle mitochondria, stimulated respiration decreased at high doses (50 and 100 μg/mL LPS). CONCLUSION LPS reduced cellular ATP content of HepG2 cells, most likely as a result of the induced decrease in membrane potential. LPS decreased cellular and isolated mitochondrial respiration in a time-dependent, dose-dependent and complex-dependent manner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Patients with biochemical failure (BF) after radical prostatectomy may benefit from dose-intensified salvage radiation therapy (SRT) of the prostate bed. We performed a randomized phase III trial assessing dose intensification. PATIENTS AND METHODS Patients with BF but without evidence of macroscopic disease were randomly assigned to either 64 or 70 Gy. Three-dimensional conformal radiation therapy or intensity-modulated radiation therapy/rotational techniques were used. The primary end point was freedom from BF. Secondary end points were acute toxicity according to the National Cancer Institute Common Terminology Criteria for Adverse Events (version 4.0) and quality of life (QoL) according to the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaires C30 and PR25. RESULTS Three hundred fifty patients were enrolled between February 2011 and April 2014. Three patients withdrew informed consent, and three patients were not eligible, resulting in 344 patients age 48 to 75 years in the safety population. Thirty patients (8.7%) had grade 2 and two patients (0.6%) had grade 3 genitourinary (GU) baseline symptoms. Acute grade 2 and 3 GU toxicity was observed in 22 patients (13.0%) and one patient (0.6%), respectively, with 64 Gy and in 29 patients (16.6%) and three patients (1.7%), respectively, with 70 Gy (P = .2). Baseline grade 2 GI toxicity was observed in one patient (0.6%). Acute grade 2 and 3 GI toxicity was observed in 27 patients (16.0%) and one patient (0.6%), respectively, with 64 Gy, and in 27 patients (15.4%) and four patients (2.3%), respectively, with 70 Gy (P = .8). Changes in early QoL were minor. Patients receiving 70 Gy reported a more pronounced and clinically relevant worsening in urinary symptoms (mean difference in change score between arms, 3.6; P = .02). CONCLUSION Dose-intensified SRT was associated with low rates of acute grade 2 and 3 GU and GI toxicity. The impact of dose-intensified SRT on QoL was minor, except for a significantly greater worsening in urinary symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND High-dose benzodiazepine dependence constitutes a major clinical concern. Although withdrawal treatment is recommended, it is unsuccessful for a significant proportion of affected patients. More recently, a benzodiazepine maintenance approach has been suggested as an alternative for patients' failing discontinuation treatment. While there is some data supporting its effectiveness, patients' perceptions of such an intervention have not been investigated. METHODS An exploratory qualitative study was conducted among a sample of 41 high-dose benzodiazepine (BZD)-dependent patients, with long-term use defined as doses equivalent to more than 40 mg diazepam per day and/or otherwise problematic use, such as mixing substances, dose escalation, recreational use, or obtainment by illegal means. A qualitative content analysis approach was used to evaluate findings. RESULTS Participants generally favored a treatment discontinuation approach with abstinence from BZD as its ultimate aim, despite repeated failed attempts at withdrawal. A maintenance treatment approach with continued prescription of a slow-onset, long-acting agonist was viewed ambivalently, with responses ranging from positive and welcoming to rejection. Three overlapping themes of maintenance treatment were identified: "Only if I can try to discontinue…and please don't call it that," "More stability and less criminal activity…and that is why I would try it," and "No cure, no brain and no flash…and thus, just for everybody else!" CONCLUSIONS Some patients experienced slow-onset, long-acting BZDs as having stabilized their symptoms and viewed these BZDs as having helped avoid uncontrolled withdrawal and abstain from criminal activity. We therefore encourage clinicians to consider treatment alternatives if discontinuation strategies fail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fatal hyperammonemia secondary to chemotherapy for hematological malignancies or following bone marrow transplantation has been described in few patients so far. In these, the pathogenesis of hyperammonemia remained unclear and was suggested to be multifactorial. We observed severe hyperammonemia (maximum 475 μmol/L) in a 2-year-old male patient, who underwent high-dose chemotherapy with carboplatin, etoposide and melphalan, and autologous hematopoietic stem cell transplantation for a neuroblastoma stage IV. Despite intensive care treatment, hyperammonemia persisted and the patient died due to cerebral edema. The biochemical profile with elevations of ammonia and glutamine (maximum 1757 μmol/L) suggested urea cycle dysfunction. In liver homogenates, enzymatic activity and protein expression of the urea cycle enzyme carbamoyl phosphate synthetase 1 (CPS1) were virtually absent. However, no mutation was found in CPS1 cDNA from liver and CPS1 mRNA expression was only slightly decreased. We therefore hypothesized that the acute onset of hyperammonemia was due to an acquired, chemotherapy-induced (posttranscriptional) CPS1 deficiency. This was further supported by in vitro experiments in HepG2 cells treated with carboplatin and etoposide showing a dose-dependent decrease in CPS1 protein expression. Due to severe hyperlactatemia, we analysed oxidative phosphorylation complexes in liver tissue and found reduced activities of complexes I and V, which suggested a more general mitochondrial dysfunction. This study adds to the understanding of chemotherapy-induced hyperammonemia as drug-induced CPS1 deficiency is suggested. Moreover, we highlight the need for urgent diagnostic and therapeutic strategies addressing a possible secondary urea cycle failure in future patients with hyperammonemia during chemotherapy and stem cell transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the role of an ultra-low-dose dual-source CT coronary angiography (CTCA) scan with high pitch for delimiting the range of the subsequent standard CTCA scan. METHODS 30 patients with an indication for CTCA were prospectively examined using a two-scan dual-source CTCA protocol (2.0 × 64.0 × 0.6 mm; pitch, 3.4; rotation time of 280 ms; 100 kV): Scan 1 was acquired with one-fifth of the tube current suggested by the automatic exposure control software [CareDose 4D™ (Siemens Healthcare, Erlangen, Germany) using 100 kV and 370 mAs as a reference] with the scan length from the tracheal bifurcation to the diaphragmatic border. Scan 2 was acquired with standard tube current extending with reduced scan length based on Scan 1. Nine central coronary artery segments were analysed qualitatively on both scans. RESULTS Scan 2 (105.1 ± 10.1 mm) was significantly shorter than Scan 1 (127.0 ± 8.7 mm). Image quality scores were significantly better for Scan 2. However, in 5 of 6 (83%) patients with stenotic coronary artery disease, a stenosis was already detected in Scan 1 and in 13 of 24 (54%) patients with non-stenotic coronary arteries, a stenosis was already excluded by Scan 1. Using Scan 2 as reference, the positive- and negative-predictive value of Scan 1 was 83% (5 of 6 patients) and 100% (13 of 13 patients), respectively. CONCLUSION An ultra-low-dose CTCA planning scan enables a reliable scan length reduction of the following standard CTCA scan and allows for correct diagnosis in a substantial proportion of patients. ADVANCES IN KNOWLEDGE Further dose reductions are possible owing to a change in the individual patient's imaging strategy as a prior ultra-low-dose CTCA scan may already rule out the presence of a stenosis or may lead to a direct transferal to an invasive catheter procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Air enema under fluoroscopy is a well-accepted procedure for the treatment of childhood intussusception. However, the reported radiation doses of pneumatic reduction with conventional fluoroscopy units have been high in decades past. OBJECTIVE To compare current radiation doses at our institution to past doses reported by others for fluoroscopic-guided pneumatic reduction of ileo-colic intussusception in children. MATERIALS AND METHODS Since 2007 radiologists and residents in our department who perform reduction of intussusceptions have received a radiation risk training. We retrospectively analyzed the data of 45 children (5 months-8 years) who underwent a total of 48 pneumatic reductions of ileo-colic intussusception between 2008 and 2012. We analyzed data for screening time and dose area product (DAP) and compared these data to those reported up to and including the year 2000. RESULTS Our mean screening time measured by the DAP-meter was 53.8 s (range 1-320 s, median 33.0 s). The mean DAP was 11.4 cGy ∙ cm(2) (range 1-145 cGy ∙ cm(2), median 5.45 cGy ∙ cm(2)). There was one bowel perforation, in a 1-year-old boy requiring surgical revision. Only three studies in the literature presented radiation exposure results on children who received pneumatic or hydrostatic reduction of intussusception under fluoroscopy. Screening times and dose area products in those studies, which were published in the 1990 s and in the year 2000, were substantially higher than those in our sample. CONCLUSION Low-frequency pulsed fluoroscopy and other dose-saving keys as well as the radiation risk training might have helped to improve the quality of the procedure in terms of radiation exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Newly diagnosed WHO grade II-III or any WHO grade recurrent meningioma exhibit an aggressive behavior and thus are considered as high- or intermediate risk tumors. Given the unsatisfactory rates of disease control and survival after primary or adjuvant radiation therapy, optimization of treatment strategies is needed. We investigated the potential of dose-painting intensity-modulated proton beam-therapy (IMPT) for intermediate- and high-risk meningioma. MATERIAL AND METHODS Imaging data from five patients undergoing proton beam-therapy were used. The dose-painting target was defined using [68]Ga-[1,4,7,10-tetraazacyclododecane tetraacetic acid]- d-Phe(1),Tyr(3)-octreotate ([68]Ga-DOTATATE)-positron emission tomography (PET) in target delineation. IMPT and photon intensity-modulated radiation therapy (IMRT) treatment plans were generated for each patient using an in-house developed treatment planning system (TPS) supporting spot-scanning technology and a commercial TPS, respectively. Doses of 66 Gy (2.2 Gy/fraction) and 54 Gy (1.8 Gy/fraction) were prescribed to the PET-based planning target volume (PTVPET) and the union of PET- and anatomical imaging-based PTV, respectively, in 30 fractions, using simultaneous integrated boost. RESULTS Dose coverage of the PTVsPET was equally good or slightly better in IMPT plans: dose inhomogeneity was 10 ± 3% in the IMPT plans vs. 13 ± 1% in the IMRT plans (p = 0.33). The brain Dmean and brainstem D50 were small in the IMPT plans: 26.5 ± 1.5 Gy(RBE) and 0.002 ± 0.0 Gy(RBE), respectively, vs. 29.5 ± 1.5 Gy (p = 0.001) and 7.5 ± 11.1 Gy (p = 0.02) for the IMRT plans, respectively. The doses delivered to the optic structures were also decreased with IMPT. CONCLUSIONS Dose-painting IMPT is technically feasible using currently available planning tools and resulted in dose conformity of the dose-painted target comparable to IMRT with a significant reduction of radiation dose delivered to the brain, brainstem and optic apparatus. Dose escalation with IMPT may improve tumor control and decrease radiation-induced toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pregnant BALB/c mice have been widely used as an in vivo model to study Neospora caninum infection biology and to provide proof-of-concept for assessments of drugs and vaccines against neosporosis. The fact that this model has been used with different isolates of variable virulence, varying infection routes and differing methods to prepare the parasites for infection, has rendered the comparison of results from different laboratories impossible. In most studies, mice were infected with similar number of parasites (2 × 10(6)) as employed in ruminant models (10(7) for cows and 10(6) for sheep), which seems inappropriate considering the enormous differences in the weight of these species. Thus, for achieving meaningful results in vaccination and drug efficacy experiments, a refinement and standardization of this experimental model is necessary. Thus, 2 × 10(6), 10(5), 10(4), 10(3) and 10(2) tachyzoites of the highly virulent and well-characterised Nc-Spain7 isolate were subcutaneously inoculated into mice at day 7 of pregnancy, and clinical outcome, vertical transmission, parasite burden and antibody responses were compared. Dams from all infected groups presented nervous signs and the percentage of surviving pups at day 30 postpartum was surprisingly low (24%) in mice infected with only 10(2) tachyzoites. Importantly, infection with 10(5) tachyzoites resulted in antibody levels, cerebral parasite burden in dams and 100% mortality rate in pups, which was identical to infection with 2 × 10(6) tachyzoites. Considering these results, it is reasonable to lower the challenge dose to 10(5) tachyzoites in further experiments when assessing drugs or vaccine candidates.