Resumo

BACKGROUND Air enema under fluoroscopy is a well-accepted procedure for the treatment of childhood intussusception. However, the reported radiation doses of pneumatic reduction with conventional fluoroscopy units have been high in decades past. OBJECTIVE To compare current radiation doses at our institution to past doses reported by others for fluoroscopic-guided pneumatic reduction of ileo-colic intussusception in children. MATERIALS AND METHODS Since 2007 radiologists and residents in our department who perform reduction of intussusceptions have received a radiation risk training. We retrospectively analyzed the data of 45 children (5 months-8 years) who underwent a total of 48 pneumatic reductions of ileo-colic intussusception between 2008 and 2012. We analyzed data for screening time and dose area product (DAP) and compared these data to those reported up to and including the year 2000. RESULTS Our mean screening time measured by the DAP-meter was 53.8 s (range 1-320 s, median 33.0 s). The mean DAP was 11.4 cGy ∙ cm(2) (range 1-145 cGy ∙ cm(2), median 5.45 cGy ∙ cm(2)). There was one bowel perforation, in a 1-year-old boy requiring surgical revision. Only three studies in the literature presented radiation exposure results on children who received pneumatic or hydrostatic reduction of intussusception under fluoroscopy. Screening times and dose area products in those studies, which were published in the 1990 s and in the year 2000, were substantially higher than those in our sample. CONCLUSION Low-frequency pulsed fluoroscopy and other dose-saving keys as well as the radiation risk training might have helped to improve the quality of the procedure in terms of radiation exposure.

Formato

application/pdf

Identificador

http://boris.unibe.ch/77402/1/art%253A10.1007%252Fs00247-014-3218-3.pdf

Cullmann, Jennifer; Heverhagen, Johannes; Puig, Stefan (2015). Radiation dose in pneumatic reduction of ileo-colic intussusceptions--results from a single-institution study. Pediatric radiology, 45(5), pp. 675-677. Springer 10.1007/s00247-014-3218-3 <http://dx.doi.org/10.1007/s00247-014-3218-3>

doi:10.7892/boris.77402

info:doi:10.1007/s00247-014-3218-3

info:pmid:25416930

urn:issn:0301-0449

Idioma(s)

eng

Publicador

Springer

Relação

http://boris.unibe.ch/77402/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Cullmann, Jennifer; Heverhagen, Johannes; Puig, Stefan (2015). Radiation dose in pneumatic reduction of ileo-colic intussusceptions--results from a single-institution study. Pediatric radiology, 45(5), pp. 675-677. Springer 10.1007/s00247-014-3218-3 <http://dx.doi.org/10.1007/s00247-014-3218-3>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed