104 resultados para Tratamento pós-colheita


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to analyze the phenomenon of abdication of monitoring/treatment of crack users in a CAPS AD in Campina Grande-PB. That s an exploratory , description approach ,whose theoretical focus was historical-dialect of public politics on alcohol and drugs. The information collected was realized by using the technique of semi-structured interviews, combined with the crack users registered in CAPS AD in Campina Grande between 2007 and 2011.The material collected was subjected to thematic analysis method, obtaining the extraction of the following categories and subcategories of analysis: CATEGORY 1: Factors of abdication of monitoring/treatment in CAPS AD in Campina Grande PB with subcategory 1.1. Abdication on their own , 1.2. To take work/employment, 1.3 . Search for more intensive treatment , 1.4. Due to relapse; CATEGORY 2 : Treatment/monitoring in CAPS AD to the subcategory, 2.1. The dependence of crack and family support as reasons that led to frequent CAPS AD. CATEGORY 3: Living with crack addiction without treatment/monitoring in CAPS AD with the subcategory, 3.1. Religiosity as a therapeutic tool .The results showed a distance between priority for community treatment and the reality where there is lack of information about this kind of treatment and the admission as a solution. The discourse about the abdication of treatment of crack users make reference to the importance of family support, to the influence for the phenomenon of relapse and the affection to religious conceptions. Although the subjects recognize the qualifications of CAPS AD treatment, they try by themselves or by family influence, another ways of hospitalization. This leads us to conclude that it is necessary reflection and assessment of the work of CAPS AD. Counting on the social changes and the need of answers that the phenomenon requires

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The therapeutic adherence is still a big problem among people with venous ulcers (VU) because the treatment is long, expensive and demand changes in lifestyle. In this context, this study aims to examine treatment adherence and quality of life (QOL) of people with VU assisted at primary health care. This is an analytical, cross-sectional study with a quantitative approach to treatment and data analysis. The study had the scenario 13 Family Health Units and 02 Units Mixed of Natal. The target population consisted of 44 persons with UV indicated by the teams of the Family Health Strategy between February and April 2014. Three instruments were used: an instrument to characterize the sociodemographic, health and care aspects, the Multidimensional Scale of Adherence Therapy composed of the dimensions: healthy lifestyle, compressive therapy and neurovascular monitoring and the Charing Cross Venous Ulcer Questionnaire (CCVUQ) that evaluates QOL in persons with VU composed by the domains: Total Score, Social Interaction, Domestic Activities, Aesthetics and Emotional State. The study was approved by the Ethics Committee in Research of the Federal University of Rio Grande do Norte, CAAE: 07556312.0.0000.5537. The data concerning the sociodemographic characteristics showed that there was a predominance of females (65.9%), age range as of 60 years (59.1%) and income of up to 1 minimum wage (81.8%). With the characterization of health, it was evident that most people reported chronic diseases (63.6%), sleep more than 6 hours (81.8%), present pain (81.8%), denying alcoholism (86 4%) and smoking (77.3%) and showed a number greater than or equal to 1 (77.3%) recurrences. Concerning the therapeutic adherence was found that in the dimension compressive therapy there poor adherence. No associations between the domains of adherence and sociodemographic and health variables were found. Was observed, however, better adherence among individuals without pain and with higher schooling. When analyzed the averages of the dimensions of therapeutic adherence with the care characteristics there was statistical significance between: adherence to compression therapy and guidance for use of compressive therapy (p = 0.002) and guidance for regular exercise (p = 0.026). Considering the mean of total score of CCVUQ (mean 51.47, SD 18.33) it is observed that the overall QOL of respondents has approximate value of the median of the scale (50). The mean of the domain Social Interaction (mean 44.23, SD 21.38) and Domestic Activities (mean 45.70, SD 23.21) were those who reported better QOL. There were weak correlations but significant between adherence to healthy lifestyle and Domains Total Score (p = 0.012), social interaction (p-value = 0.048), Aesthetics (p-value = 0.025) and Emotional State (0.017) of CCVUQ. From the data analysis it is concluded that among people with UV, there poor adherence to compressive therapy. Furthermore, we found no statistically significant association between treatment adherence and sociodemographic and health characteristics. It is added that there was a correlation between the healthy lifestyle dimension and domains CCVUQ

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work addresses biodiesel by transesterification from the use of waste frying oil as a possible technological alternative for both reducing greenhouse gas emissions and by presenting themselves as an environmental call to designate a rational use of oil when no longer played in the environment to become renewable energy. It has proposed location of a residual oil and fat treatment plant to produce biodiesel, using models of Location and Routing for the improvement of routes. To achieve the goal, questionnaires were administered in establishments that use oil or vegetable fat in their productive activities in order to quantify the residue, to analyze actions and environmental perception of people who work directly with the residue on the destination you are being given to oil and fat used. It has indicated using of two single setup location, the method of Center of Gravity and the model of Ardalan, a geographical point that minimizes the costs of transporting waste to the treatment plant. Actions have been proposed for the improvement of collection routes this residue using the Routing Method of Scanning, as an illustration. The results demonstrated the lack of knowledge of the people who deal directly with large amounts of waste, on the environmental impacts caused by their incorrect disposal. The models used were uniform since point out to neighborhoods in similar regions. The neighborhoods of Lagoa Nova / Morro Branco (Ardalan) and Nova Descoberta (Center of Gravity) as ideal for the installation of treatment plant. However, it is suggested to be tested other models that take into account new variables than those used (supply of waste and the distance between points). The routing through the method of scanning has shown that it is possible, in a simple way to optimize routes in order to reduce distances and therefore the logistics costs in the collection of such waste. Introducing a route as a test to gather the twenty largest oil suppliers used in sample frying, using as a main factor time 8 hour of working shift every day

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The pumping of fluids in pipelines is the most economic and safe form of transporting fluids. That explains why in Europe there was in 1999 about 30.000 Km [7] of pipelines of several diameters, transporting millíons of cubic meters of crude oil end refined products, belonging to COCAWE (assaciation of companies of petroleum of Europe for health, environment and safety, that joint several petroleum companies). In Brazil they are about 18.000 Km of pipelines transporting millions of cubic meters of liquids and gases. In 1999, nine accidents were registered to COCAWE. Among those accidents one brought a fatal victim. The oil loss was of 171 m3, equivalent to O,2 parts per million of the total of the transported volume. Same considering the facts mentioned the costs involved in ao accident can be high. An accident of great proportions can bríng loss of human lives, severe environmental darnages, loss of drained product, loss . for dismissed profit and damages to the image of the company high recovery cost. In consonance with that and in some cases for legal demands, the companies are, more and more, investing in systems of Leak detection in pipelines based on computer algorithm that operate in real time, seeking wíth that to minimize still more the drained volumes. This decreases the impacts at the environment and the costs. In general way, all the systems based on softWare present some type of false alarm. In general a commitment exists betWeen the sensibílity of the system and the number of false alarms. This work has as objective make a review of thé existent methods and to concentrate in the analysis of a specific system, that is, the system based on hydraulic noise, Pressure Point Analyzis (PPA). We will show which are the most important aspects that must be considered in the implementation of a Leak Detection System (LDS), from the initial phase of the analysis of risks passing by the project bases, design, choice of the necessary field instrumentation to several LDS, implementation and tests. We Will make na analysis of events (noises) originating from the flow system that can be generator of false alarms and we will present a computer algorithm that restricts those noises automatically

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Some fibrous materials, for having properties such as biocompatibility, strength and flexibility, are of great interest for medical and pharmaceutical applications. Among these materials, the fabric made from polylactic acid (PLA) has received special attention, and beside to present these features, is derived from biological source, antimicrobial and bioabsorbable. One of the limitations of PLA is its low wettability and capillarity. Due to this, it is necessary to perform surface modification of the knitted fabric, increasing its hydrophilicity. This work aims to realize the plasma treatment at low pressure in order to increase the surface energy of the polymer. The work was divided into three steps: i) Influence of the gas ratio (oxygen and nitrogen) in the surface modification of PLA fabric after the plasma treatment, ii) physical characterization and physicochemical surface tissue; iii) Evaluation of the effect from current and gas ratio in the capillary rise of tissues and iv) Study of capillarity in yarns and fabrics. The results showed that better gas ratios were the atmospheres: 100% oxygen; 100% nitrogen and 50% oxygen and 50% nitrogen. The surface characterization showed changes in topography and introduction of polar groups which increased the wettability of the fabric. In another part of this study, it was found that the atmosphere containing only nitrogen gas showed the most capillary rise to a current of 0.15 A. The results in capillary yarns and fabrics showed that the thread reached equilibrium in a time much less than the fabric to an atmosphere of 100% nitrogen and 0.15 A. Current Plasma technology was effective to increase the hydrophilicity of PLA fabric, providing surface characteristics favorable for future application in the biomedical field

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The production of petroleum is frequently accomplished with great volumes of water, that it is carried of the underground with the oil. It is a challenge of the present century the development of technologies that allow the use of waste water for purposes that consume great amounts of water and don't demand as rigid as the one of the drinking water requirements. The solar distillation has been configuring as an alternative of clean technology for desalination of brine and saline. Besides causing the minimum possible damage to the environment, it takes advantage of an abundant and free energy source: the solar energy. That study aims to develop a Solar Distillator for treatment of the produced water of the oil wells, to obtain an efluent to use in agriculture and vapor generation. The methodology for collection, conservation and analysis of the physical-chemical parameters obeyed the norms in APHA (1995). The sampling was of the composed type. Experiments were accomplished in the solar distillation pilot and simulation in thermostatic bathing. The operation was in batch system and for periods of 4, 6 and 12 h. The developed Distillator is of the type simple effect of two waters. It was still tested two inclination angles for covering; 20º and 45º. The Distillator presented minimum of 2,85 L/m2d revenues and maximum of 7,14 L/m2d. The removals of salts were great than 98%. The removal of TOC in the simulation was great than 90%. In agreement with the data of energy and mass balance, it was verified that the developed solar Distillator presented compatible revenues with those found in literature for similar types. It can be inferred that the obtained distilled water assists to the requirements CONAMA in almost all the points and could be used for irrigation of cultures such as cotton and mamona. As the distilled water has characteristics of fresh water it can be used in the generation of vapor

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With water pollution increment at the last years, so many progresses in researches about treatment of contaminated waters have been developed. In wastewaters containing highly toxic organic compounds, which the biological treatment cannot be applied, the Advanced Oxidation Processes (AOP) is an alternative for degradation of nonbiodegradable and toxic organic substances, because theses processes are generation of hydroxyl radical based on, a highly reactivate substance, with ability to degradate practically all classes of organic compounds. In general, the AOP request use of special ultraviolet (UV) lamps into the reactors. These lamps present a high electric power demand, consisting one of the largest problems for the application of these processes in industrial scale. This work involves the development of a new photochemistry reactor composed of 12 low cost black light fluorescent lamps (SYLVANIA, black light, 40 W) as UV radiation source. The studied process was the photo-Fenton system, a combination of ferrous ions, hydrogen peroxide, and UV radiation, it has been employed for the degradation of a synthetic wastewater containing phenol as pollutant model, one of the main pollutants in the petroleum industry. Preliminary experiments were carrier on to estimate operational conditions of the reactor, besides the effects of the intensity of radiation source and lamp distribution into the reactor. Samples were collected during the experiments and analyzed for determining to dissolved organic carbon (DOC) content, using a TOC analyzer Shimadzu 5000A. The High Performance Liquid Chromatography (HPLC) was also used for identification of the cathecol and hydroquinone formed during the degradation process of the phenol. The actinometry indicated 9,06⋅1018 foton⋅s-1 of photons flow, for 12 actived lamps. A factorial experimental design was elaborated which it was possible to evaluate the influence of the reactants concentration (Fe2+ and H2O2) and to determine the most favorable experimental conditions ([Fe2+] = 1,6 mM and [H2O2] = 150,5 mM). It was verified the increase of ferrous ions concentration is favorable to process until reaching a limit when the increase of ferrous ions presents a negative effect. The H2O2 exhibited a positive effect, however, in high concentrations, reaching a maximum ratio degradation. The mathematical modeling of the process was accomplished using the artificial neural network technique

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The decontamination of the materials has been subject of some studies. One of the factors that it increases the pollution is the lack of responsibility in the discarding of toxic trash, as for example the presence of PCB (Polychlorinated Biphenyls) in the environment. In the Brazilian regulations, the material contaminated with PCB in concentrations higher than 50 ppm must be stored in special places or destroyed, usually by incineration in plasma furnace with dual steps. Due to high cost of the procedure, new methodologies of PCBs removal has been studied. The objective of this study was to develop an experimental methodology and analytical methodology for quantification of removal of PCBs through out the processes of extractions using supercritical fluid and Soxhlet method, also technical efficiency of the two processes of extraction, in the treatment of contaminated materials with PCBs. The materials studied were soils and wood, both were simulated contamination with concentration of 6.000, 33.000 and 60.000 mg of PCB/ kg of materials. Soxhlet extractions were performed using 100 ml of hexane, and temperature of 180 ºC. Extractions by fluid supercritical were performed at conditions of 200 bar, 70°C, and supercritical CO2 flow-rate of 3 g/min for 1-3 hours. The extracts obtained were quantified using Gas chromatography-mass spectrometry (GC/MS). The conventional extractions were made according to factorial experimental planning technique 22, with aim of study the influence of two variables of process extraction for the Soxhlet method: contaminant concentration and extraction time for obtain a maximum removal of PCB in the materials. The extractions for Soxhlet method were efficient for extraction of PCBs in soil and wood in both solvent studied (hexane and ethanol). In the experimental extraction in soils, the better efficient of removal of PCBs using ethanol as solvent was 81.3% than 95% for the extraction using hexane as solvent, for equal time of extraction. The results of the extraction with wood showed statistically it that there is not difference between the extractions in both solvent studied. The supercritical fluid extraction in the conditions studied showed better efficiency in the extraction of PCBs in the wood matrix than in soil, for two hours extractions the obtain percentual of 43.9 ± 0.5 % for the total of PCBs extracted in the soils against 95.1 ± 0,5% for the total of PCBs extracted in the wood. The results demonstrated that the extractions were satisfactory for both technical studied

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work had as objective to apply an experimental planning aiming at to improve the efficiency of separation of a new type of mixer-settler applied to treat waste water contaminated with oil. An unity in scale of laboratory, was installed in the Post-graduation Program of Chemical Engineering of UFRN. It was constructed in partnership with Petrobras S.A. This called device Misturador-Decantador a Inversão de Fases (MDIF) , possess features of conventional mixer-settler and spray column type. The equipment is composed of three main parts: mixing chamber; chamber of decantation and chamber of separation. The efficiency of separation is evaluated analyzing the oil concentrations in water in the feed and the output of the device. For the analysis one used the gravimetric method of oil and greases analysis (TOG). The system in study is a water of formation emulsified with oil. The used extractant is a mixture of Turpentine spirit hydro-carbons, supplied for Petrobras. It was applied, for otimization of the efficiency of separation of the equipment, an experimental planning of the composite central type, having as factorial portion fractionary factorial planning 2 5-2, with the magnifying of the type star and five replications in the central point. In this work, the following independents variables were studied: contents of oil in the feed of the device; volumetric ratio (O/A); total flowrate ; agitation in the mixing chamber and height of the organic bed. Minimum and maximum limits for the studied variables had been fixed according previous works. The analysis of variance for the equation of the empirical model, revealed statistically significant and useful results for predictions ends. The variance analysis also presented the distribution of the error as a normal distribution and was observed that as the dispersions do not depend on the levels of the factors, the independence assumption can be verified. The variation around the average is explained by 98.98%, or either, equal to the maximum value, being the smoothing of the model in relation to the experimental points of 0,98981. The results present a strong interaction between the variable oil contents in the feed and agitation in the mixing chamber, having great and positive influence in the separation efficiency. Another variable that presented a great positive influence was the height of the organic bed. The best results of separation efficiency had been obtained for high flowrates when associates the high oil concentrations and high agitation. The results of the present work had shown excellent agreement with the results carried out through previous works with the mixer-settler of phase inversion

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The generation of wastes in most industrial process is inevitable. In the petroleum industry, one of the greatest problems for the environment is the huge amount of produced water generated in the oil fields. This wastewater is a complex mixture and present great amounts. These effluents can be hazardous to the environmental without adequate treatment. This research is focused in the analysis of the efficiencies of the flotation and photo-oxidation processes to remove and decompose the organic compounds present in the produced water. A series of surfactants derivated from the laurilic alcohol was utilized in the flotation to promote the separation. The experiments have been performed with a synthetic wastewater, carefully prepared with xylene. The experimental data obtained using flotation presented a first order kinetic, identified by the quality of the linear data fitting. The best conditions were found at 0.029 g.L-1 for the surfactant EO 7, 0.05 g.L-1 for EO 8, 0.07 g.L-1 for EO 9, 0.045 g.L-1 for EO 10 and 0.08 g.L-1 for EO 23 with the following estimated kinetic constants: 0.1765, 0.1325, 0.1210, 0.1531 and 0.1699 min-1, respectively. For the series studied, the most suitable surfactant was the EO 7 due to the lower reagent onsumption, higher separation rate constant and higher removal efficiency of xylene in the aqueous phase (98%). Similarly to the flotation, the photo-Fenton process shows to be efficient for degradation of xylene and promoting the mineralization of the organic charge around 90% and 100% in 90 min

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The soil contamination with petroleum is one of the major concern of industries operating in the field and also of environmental agencies. The petroleum consists mainly of alkanes and aromatic hydrocarbons. The most common examples of hydrocarbons polyaromatic are: naphthalene, anthracene, phenanthrene, benzopyrene and their various isomers. These substances cause adverse effects on human and the environment. Thus, the main objective of this work is to study the advanced oxidation process using the oxidant potassium permanganate (KMnO4) for remediation of soils contaminated with two polyaromatic hydrocarbons (PAHs): anthracene and phenanthrene. This study was conducted at bench scale, where the first stage was at batch experiment, using the variables: the time and oxidant dosage in the soil. The second stage was the remediation conducted in continous by a fix column, to this stage, the only variable was remediation time. The concentration of oxidant in this stage was based on the best result obtained in the tests at batch, 2,464 mg / L. The results of degradation these contaminants were satisfactory, at the following dosages and time: (a) 5g of oxidant per kg soil for 48 hours, it was obtained residual contaminants 28 mg phenanthrene and 1.25 mg anthracene per kg of soil and (b) for 7g of oxidant per kg soil in 48 hours remaining 24 mg phenanthrene and anthracene 0.77 mg per kg soil, and therefore below the intervention limit residential and industrial proposed by the State Company of Environmental Sao Paulo (CETESB)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Textile industry deals with a high diversity of processes and generation of wastewaters with a high content of pollutant material. Before being disposed of in water bodies, a pre-treatment of the effluent is carried out, which is sometimes ineffective. In order to be properly treated, physical and chemical properties of the effluent must be known, as well as the pollutant agents that might be present in it. This has turned out to be a great problem in the textile industry, for there is a variety of processes and the pollutant load is very diversified. The characterization of the effluent allows the identification of most critical points and, as a consequence, the most appropriate treatment procedure to be employed, may be chosen. This study presents the results obtained after characterizing the effluent of a textile industry that comprises knitting, dyeing and apparel sections, processing mainly polyester/cotton articles. In this work, twenty samples of the effluent were collected, and related to the changes in production. From the results, a statistical evaluation was applied, determined in function of the rate of flow. The following properties and pollutants agents were quantitatively analysed: temperature; pH; sulfides; chlorine; alcalinity; chlorides; cianides; phenols; color; COD (Chemical Oxygen Demand); TOC (Total Organic Carbon); oil and grease; total, fixed and volatile solids; dissolved, fixed and volatile solids; suspended, fixed and volatile solids; setteable solids and heavy metals such as cadmium, copper, lead, chromium, tin, iron, zinc and nickel. Analyses were carried out according to ABNT NBR 13402 norm, based upon Standard Methods for the Examination of Water and Wastewater. As a consequence, a global treatment proposal is presented, involving clean production practices as contaminant load reducer, followed by conventional (biological) treatment

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work is to use a new technology in the treatment of produced wastewaters from oil industry. An unit for treat produced waters called UTMDIF, was designed, installed and operated in an industrial plant for treatment of effluents from oil industry. This unit operates by means of the method of separation of phase inversion and can become a promising alternative to solve the problem of oil/water separation. This method constitutes the basis of the working of a new design of mixersettler of vertical configuration which occupies small surface area. The last characteristic becomes specially important when there is limitation on the lay-out of the plant, for example, over maritime platforms to explore oil. This equipment in a semi-industrial scale treats produced wastewaters contaminated with oil at low concentrations (ranging from 30 to 150 mg/L) and throughputs of 320 m3/d (47,4 m3 m-2 h-1). Good results were obtained in oil/water separation which leads to the necessary specification to discharge those wastewaters. Besides, the non dependence of the efficiency of separation in spite of the salinity of the medium becomes the equipment an attractive new technology to treat wastewaters containing oil at low concentrations

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Naphthenic lubricating oils are used in transformers with the purpose of promoting electrical insulation and dissipating heat. The working temperature range of these oils typically lies between 60°C and 90°C and their useful life is 40 years in average. In that temperature range, the oils are decomposed during operation, whereby a small fraction of polar compounds are formed. The presence of these compounds may induce failure and loss of physical, chemical and electrical properties of the oil, thus impairing the transformer operation. By removing these contaminants, one allows the oxidized insulating oil to be reused without damaging the equipment. In view of this, an investigation on the use of surfactants and microemulsions as extracting agents, and modified diatomite as adsorbent, has been proprosed in this work aiming to remove polar substances detected in oxidized transformer oils. The extraction was carried out by a simple-contact technique at room temperature. The system under examination was stirred for about 10 minutes, after which it was allowed to settle at 25°C until complete phase separation. In another experimental approach, adsorption equilibrium data were obtained by using a batch system operating at temperatures of 60, 80 and 100°C. Analytical techniques involving determination of the Total Acidity Number (TAN) and infrared spectrophotometry have been employed when monitoring the decomposition and recovery processes of the oils. The acquired results indicated that the microemulsion extraction system comprising Triton® X114 as surfactant proved to be more effective in removing polar compounds, with a decrease in TAN index from 0.19 to 0.01 mg KOH/g, which is consistent with the limits established for new transformer oils (maximal TAN = 0.03 mg KOH/g). In the adsorption studies, the best adsorption capacity values were as high as 0.1606 meq.g/g during conventional adsoprtion procedures using natural bauxite, and as high as 0.016 meq.g/g for the system diatomite/Tensiofix® 8426. Comparatively in this case, a negative effect could be observed on the adsorption phenomenon due to microemulsion impregnation on the surface of the diatomite

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a spray-dryer designed to oxalate-niobate precursors and suitable for the production of Niobium Carbide. The dryer was intended to produce powders of controlled particle size. First, the precursor is dissolved in water to produce a solution of known concentration and then it is atomized on the spray-dryer to produce the powder. This equipment consists of a 304 stainless steel chamber, 0.48 m x 1.9 m (diameter x length), with a conical shape at the lower portion, which is assembled on a vertical platform. The chamber is heated by three 4 kW electrical resistances. In this process, drying air is heated as it flows inside a serpentine surrounding the chamber, in contrary to more traditional processes in which the hot drying air is used to heat the component. The air enters the chamber at the same temperature of the chamber, thus avoiding adherence of particles on the internal surface. The low speed flow is concurrent, directed from the top to the bottom portion of the chamber. Powders are deposited on a 0.4 m diameter tray, which separates the cylindrical portion from the conical portion of the chamber. The humid air is discharged though a plug placed underneath the collecting tray. A factorial experimental planning was prepared to study the influence of five parameters (concentration, input flow, operation temperature, drying air flow and spray air flow) on the characteristics of the powders produced. Particle size distribution and shape were measured by laser granulometry and scanning electronic microscopy. Then, the powders are submitted to reaction in a CH4 / H2 atmosphere to compare the characteristics of spray-dried powders with powders synthetizided by conventional methods