14 resultados para PAIRED URINE

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantification of uranium in human urine is a valuable technique for assessing occupational and public exposure to uranium. A reliable method has been developed and validated in the ARPANSA Radiochemistry Laboratory by means of standard radiochemical separation and purification techniques and measurement using high-resolution alpha spectrometry. This method can be used to evaluate the levels of naturally occurring 234U, 235U and 238U in urine. Method design and validation is the process of defining an analytical requirement, and then confirming that the method under consideration has performance capabilities consistent with what the application requires. The method was designed to measure levels down to 2 mBq/day of total uranium, corresponding to approximately 1/100th of the annual committed effective dose of 20 mSv. Validation tests were developed to assess selectivity, accuracy, recovery and quantification of uncertainty. The radiochemical recovery of this method was measured using 232U tracer. The typical minimum detectable concentration for total uranium for 24-h urine samples is approximately 0.6 mBq/day or 0.019 μg/day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epoetin-δ (Dynepo™ Shire Pharmaceuticals, Basing stoke, UK) is a synthetic form of erythropoietin (EPO) whose resemblance with endogenous EPO makes it hard to identify using the classical identification criteria. Urine samples collected from six healthy volunteers treated with epoetin-δ injections and from a control population were immuno-purified and analyzed with the usual IEF method. On the basis of the EPO profiles integration, a linear multivariate model was computed for discriminant analysis. For each sample, a pattern classification algorithm returned a bands distribution and intensity score (bands intensity score) saying how representative this sample is of one of the two classes, positive or negative. Effort profiles were also integrated in the model. The method yielded a good sensitivity versus specificity relation and was used to determine the detection window of the molecule following multiple injections. The bands intensity score, which can be generalized to epoetin-α and epoetin-β, is proposed as an alternative criterion and a supplementary evidence for the identification of EPO abuse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding how elephants respond to potentially stressful events, such as relocation, is important for making informed management decisions. This study followed the relocation of eight Asian elephants from the Cocos (Keeling) Islands to mainland Australia. The first goal of this study was to examine patterns of adrenocortical activity as reflected in three different substrates: serum, urine, and feces. We found that the three substrates yielded very different signals of adrenocortical activity. Fecal glucocorticoid metabolites (FGM) increased as predicted post-transport, but urinary glucocorticoid metabolites (UGM) were actually lower following transport. Serum cortisol levels did not change significantly. We suggest that the differences in FGM and UGM may reflect changes in steroid biosynthesis, resulting in different primary glucocorticoids being produced at different stages of the stress response. Additional studies are needed to more thoroughly understand the signals of adrenocortical activity yielded by different substrates. The second goal was to examine individual variation in patterns of adrenal response. There was a positive correlation between baseline FGM value and duration of post-transfer increase in FGM concentration. Furthermore, an individual's adrenocortical response to relocation was correlated with behavioral traits of elephants. Elephants that were described by keepers as being “curious” exhibited a more prolonged increase in FGM post-transfer, and “reclusive” elephants had a greater increase in FGM values. Future research should investigate the importance of these personality types for the management and welfare of elephants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urine is a preferred specimen for nucleic acid-based detection of sexually transmitted infections (STIs) but represents a challenge for microfluidic devices due to low analyte concentrations. We present an extraction methodology enabling rapid on-chip nucleic acid purification directly from clinically relevant sample volumes up to 1 ml and subsequent PCR amplification detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To compare the effectiveness and acceptability of self-monitoring of blood glucose with self-monitoring of urine glucose in adults with newly diagnosed Type 2 diabetes. METHODS: We conducted a multi-site cluster randomized controlled trial with practice-level randomization. Participants attended a structured group education programme, which included a module on self-monitoring using blood glucose or urine glucose monitoring. HbA1c and other biomedical measures as well as psychosocial data were collected at 6, 12 and 18 months. A total of 292 participants with Type 2 diabetes were recruited from 75 practices. RESULTS: HbA1c levels were significantly lower at 18 months than at baseline in both the blood monitoring group [mean (se) -12 (2) mmol/mol; -1.1 (0.2) %] and the urine monitoring group [mean (se) -13 (2) mmol/mol; -1.2 (0.2)%], with no difference between groups [mean difference adjusted for cluster effect and baseline value = -1 mmol/mol (95% CI -3, 2); -0.1% (95% CI -0.3, 0.2)]. Similar improvements were observed for the other biomedical outcomes, with no differences between groups. Both groups showed improvements in total treatment satisfaction, generic well-being, and diabetes-specific well-being, and had a less threatening view of diabetes, with no differences between groups at 18 months. Approximately one in five participants in the urine monitoring arm switched to blood monitoring, while those in the blood monitoring arm rarely switched (18 vs 1% at 18 months; P < 0.001). CONCLUSIONS: Participants with newly diagnosed Type 2 diabetes who attended structured education showed similar improvements in HbA1c levels at 18 months, regardless of whether they were assigned to blood or urine self-monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hyperglycemia causes diabetic nephropathy, a condition for which there are no specific diagnostic markers thatpredict progression to renal failure. Here we describe a multiplatform metabolomic analysis of urine from individualswith type 2 diabetes, collected before and immediately following experimental hyperglycemia. We used targetednuclear magnetic resonance spectroscopy (NMR), liquid chromatography - mass spectrometry (LC-MS) and gaschromatography - MS (GC-MS) to identify markers of hyperglycemia. Following optimization of data normalisation andstatistical analysis, we identified a reproducible NMR and LC-MS based urine signature of hyperglycemia. Significantincreases of alanine, alloisoleucine, isoleucine, leucine, N-isovaleroylglycine, valine, choline, lactate and taurine anddecreases of arginine, gamma-aminobutyric acid, hippurate, suberate and N-acetylglutamate were observed. GC-MSanalysis identified a number of metabolites differentially present in post-glucose versus baseline urine, but these could not be identified using current metabolite libraries. This analysis is an important first step towards identifying biomarkers of early-stage diabetic nephropathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty-four-hour urine collection is the recommended method for estimating sodium intake. To investigate the strengths and limitations of methods used to assess completion of 24-hour urine collection, the authors systematically reviewed the literature on the accuracy and usefulness of methods vs para-aminobenzoic acid (PABA) recovery (referent). The percentage of incomplete collections, based on PABA, was 6% to 47% (n=8 studies). The sensitivity and specificity for identifying incomplete collection using creatinine criteria (n=4 studies) was 6% to 63% and 57% to 99.7%, respectively. The most sensitive method for removing incomplete collections was a creatinine index <0.7. In pooled analysis (≥2 studies), mean urine creatinine excretion and volume were higher among participants with complete collection (P<.05); whereas, self-reported collection time did not differ by completion status. Compared with participants with incomplete collection, mean 24-hour sodium excretion was 19.6 mmol higher (n=1781 specimens, 5 studies) in patients with complete collection. Sodium excretion may be underestimated by inclusion of incomplete 24-hour urine collections. None of the current approaches reliably assess completion of 24-hour urine collection.