13 resultados para Chromatographic analysis

em Deakin Research Online - Australia


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Polystyrene behaviour in reversed phase high performance liquid chromatography was influenced mainly by the solvent system, but secondary affects were observed depending on the stationary phase. A variety of reversed phase columns were investigated using mobile phase combinations of dichlorom ethane-methanol, dichloromethane-acetonitrile, ethyl acetate-methanol and ethyl acetate-acetonitrile. Several different modes of behaviour were observed depending on the polymer solubility in the solvent system. In the dichloromethane-methanol solvent system, polymer-stationary phase interactions only occurred when the molecules had pore access. Retention of excluded polystyrene depended on the kinetics of precipitation and redissolution of the polymer. Peak splitting and band broadening occurred when the kinetics were slow and molecular weight separations were limited !o oligomers and polystyrenes lower than 5-10(4) dalton. Excellent molecular weight separations of polystyrenes were obtained using gradient elution reversed phase chromatography with a dichloromethane-acetonitrile mobile phase on C18 columns. The retention was based on polymer-stationary phase interactions regardless of the column pore size. Separations were obtained on large diameter pellicular adsorbents that were almost as good as those obtained on porous adsorbents, showing that pore access was not essential for the retention of high molecular weight polystyrenes. In the best example, the separation ranged from the monomer to 10(6) dalton in a single analysis. Very little adsorption of excluded polymers was observed on C8 or phenyl columns. Polystyrene molecular weight separations to 7-10(5) dalton were obtained in an ethyl acetate-acetonitrile solvent system on C18 columns. Adsorption was responsible for retention. When an ethyl acetate-methanol solvent system was used, no molecular weight separations were obtained because of complex peak splitting. Reversed phase chromatography was compared to size exclusion chromatography for the analysis of polydisperse polystyrenes. Similar results were obtained using both methods. However, the reversed phase method was less sensitive to concentration effects and gave better resolution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis covers the development of the traditionally fluorescent bis(8-quinolinol-5-sulfonic acid) magnesium (II) fluorophore as a chemiluminescent emitter. A brief description of luminescence spectroscopy and its application to analytical chemistry lays the foundation to the discussion of the results obtained herein. This includes the synthesis and identification of two so called ‘water soluble’ aryl oxamides 2,2’-oxalyl-bis(trifluoromethanesulfonyl) imino] ethylene-bis(N- methylpyridinium) trifluoromethane sulfonate (PETQ) and 2,2’-oxalyl-bis(trifluoromethanesulfonyl) imino]ethylene-bis(N-pyridinium) chloride (PETH), previously developed for the US navy as a possible emergency light source, yet the synthetic methodology were incomplete. The inconsistencies of the synthetic methods for PETQ and PETH were overcome with yields satisfactory for their preliminary analytical evaluation. The evaluation of these aryl oxamides, including 4,4’-oxalyI- bis[(trifluoromethanesulfonyl) imino]ethylene-bis(l-methyM-benzylpiperidinium) trifluoromethanesulfonate (BPTQ), 4,4’-oxalyl-bis [(trifluoromethylsulfonyl)imino] ethylene-bis(N-methylmorpholinium)trifluoromethanesulfonate (METQ) and the oxalate bis(2,4,6-trichlorophenyl) oxalate (TCPO) were performed with the peroxyoxalate chemiluminescent reaction using bis(8-quinolinol-5-sulfonic acid) magnesium (II) as the fluorophore. A univariate optimisation of this system resulted in 0,0082 mol 1-1 the detection limit of magnesium in the absence of cationic surfactants and 0.0041 mol 1-1 in their presence for the majority of these compounds. The oxamides were found to be insoluble in water with long ulrasonication periods required to dissolve the compound, with solvents such as acetonitrile preferred. The determination of other chemiluminescent metal-8HQS chelates to replace magnesium -8HQS in the peroxyoxalate were limited to Al (III), Cd (II), Ca (II), In (II) and Zn (II), unfortunately these metals all possessed poorer detection limits than those obtained using magnesium The base reaction conditions used for the flow injection system with chemiluminescent detection were transferred to an ion chromatographic configuration for the separation of magnesium from other cations on an exchange column. After a univariate and simplex optimisation of these conditions, the detection limit of magnesium was found to be 0.0411 mol 1-1 which was less than the limits that could be achieved with fluorescent detection, The further development of this reaction to incorporate the displacement of magnesium from Mg-EDTA by other metals that possessed a higher conditional stability constant than magnesium also proved to be problematic with interferences from not only EDTA but from the eluant (lactic acid) from the cation column. Using this system the detection limits of the displacing metals were found to be in the order of 10 mg 1-1 which was substantially less that what was observed when exactly the same configuration was used with fluorescent detection. The final component of the thesis entails the discussion of the background emission that results from the reaction of oxamides/oxalates with hydrogen peroxide. A detailed investigation into the reaction of TCPO and hydrogen peroxide in the presence of various additives, such as imidazole , heavy atoms and triethylamine illustrated the existence of a further intermediate in fee mechanism for this reaction. The species responsible for this emission was attributed to the degradation product 2,4,6-trichlorophenyi of TCPO, which was supported by the non-existent background present with the oxamides that do not contain this degradation product.

Relevância:

60.00% 60.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and rapid method for the analysis of heroin seizures by micellar electrokinetic chromatography with short-end injection is described. Separations were performed using an uncoated fused silica capillary, 50 cm×50 mm I.D.×360 mm O.D. with an effective separation length of 8 cm. The system was run at 25°C with an applied negative voltage of –25 kilovolts. Injection of each sample was for 2 s at –50 mbar. UV detection was employed with the wavelength set at 210 nm. The background electrolyte consisted of 85:15 (water:acetonitrile, v/v) containing final concentrations of 25 mM SDS and 15 mM sodium borate, pH 9.5. Samples and standards were prepared in 0.1% v/v acetic acid and diluted in the run buffer containing 1 mg/ml of N,N-dimethyl-5-methoxytryptamine as an internal standard. Under these conditions a text mixture containing caffeine, paracetamol, morphine, codeine, heroin, and acetylcodeine was resolved within 1.5 min. The method was used to determine the concentration of heroin in heroin seizure samples, and the results were in good agreement with those obtained by a validated gas chromatographic method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Selective determination of morphine in the larvae of Calliphora stygia (Fabricius) (Diptera: Calliphoridae) using acidic potassium permanganate chemiluminescence detection coupled with flow injection analysis and high-performance liquid chromatography (HPLC) is described. Larvae of C. stygia were reared on minced meat substrates that had been spiked with varying concentrations of morphine. Morphine concentrations were chosen to reflect typical levels in human tissues from opiate overdose victims. After maturing on substrates, larvae were analyzed for the presence of morphine using chemiluminescence detection coupled to flow injection analysis and a rapid HPLC method. Analysis of the larval matrix by flow injection analysis with chemiluminescence detection indicated the presence of interferants capable of generating chemiluminescence. A rapid chromatographic separation with a monolithic column allowed selective determination of morphine in larvae using postcolumn chemiluminescence detection. Larvae of C. stygia reared on substrates containing morphine at concentrations of 500 and 1000 ng/g did not sequester morphine at detectable concentrations. Larvae reared on substrates containing morphine concentrations of 2500, 5000, and 10,000 ng/g tested positive for the drug at concentrations of 765, 2720, and 3010 ng/g, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis involves an investigation in three areas; first, a study of an enzymatic-gravimetric method for the analysis of dietary fibre; second, a survey of dietary fibre intake in an area of a developing country, and finally, some observations on the functional aspects of gel-forming dietary fibre in the rat. A simple and rapid enzymatic-gravimetric assay for both soluble and insoluble dietary fibre has been critically investigated. Reference samples were also analysed by a more comprehensive, enzymatic gas chromatographic method to allow testing of the relative accuracy of the enzymatic-gravimetric method. The enzymatic-gravimetric method was found to be highly reproducible but gave a slightly higher value for total dietary fibre than the more comprehensive method. This discrepancy is probably due to the presence of small quantities of resistant starch and protein residue which are recovered in the enzymatic-gravimetric method. In the enzymatic-gas chromatographic method, protein residue is not measured, and resistant starch is estimated, but not counted as dietary fibre. The enzymatic-gravimetric method was applied to the analysis of foods commonly consumed in the Padang region of West Sumatra in Indonesia, in order to estimate dietary fibre intake in the region. Daily intakes of usual foods were estimated by use of a 24-hour recall procedure aided by food photographs to assist in the estimation of portion size. Samples of approximately 60 of the most commonly consumed foods were collected and analysed for dietary fibre. These appear to be the first data which report values for dietary fibre in Indonesion foods and they represent a significant improvement upon the existing data on crude fibre content. Knowledge of the amounts of foods usually consumed and their dietary fibre content allowed an estimation of usual intakes of dietary fibre. Fibre intake was found to be lower than in the developing countries of Africa and was comparable to intakes measured in the U.K. This is the first study to show that in this part of South East Asia, a developing country area using polished rice as a staple food, dietary fibre intakes are as low as in Western countries. Low intakes of fibre are believed to be related to the prevalence of a range of diseases and, in this study, preliminary data on the rates of non-infective, chronic diseases were collected from the two main hospitals in West Sumatra. Chronic, non-infectious diseases such as inguinal hernia, appendicitis, haemorrhoids, diabetes mellitus, hypertension and malignant neoplasms of the rectum are relatively frequent in West Sumatra. While no firm conclusions can be drawn from these data, they do show the possibility of a relationship between low intakes of dietary fibre and the prevalence of these diseases, and suggest that further investigation is necessary. Some observations were made of the effect of gel-forming dietary fibre on stomach emptying and intestinal transit rate in the rat. Xanthan gum was added to iso-osmotic solutions to produce increased viscosity and phenol sulphonphthalein (phenol red) was used as a non-absorbable marker. Gavage feeding of solutions with a range of viscosities was used to study the effect of viscosity on the rate of stomach emptying and intestinal transit. Increased viscosity was observed to slow gastro-intestinal transit and this provides one mechanism by which dietary fibre of the gel-forming type ray improve glucose tolerance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of rapid analytical methodologies for the determination of plant bioactives including antioxidants, amino acids and opium alkaloids was investigated using novel flow analysis and liquid chromatographic techniques. These methodologies were applied to the wine, food and pharmaceutical industries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several simple techniques are presented for the identification of the boundaries of chromatographic peaks. These methods provide a significant reduction in the time needed to perform the rapid, automatic calculation of the central peak moments and to evaluate the quality of a separation while improving the accuracy of the measurements of column efficiencies. It was found that the identification of the peak boundaries as functions of the peak widths and the examination of the slope of the signal to noise versus time plot are viable alternatives to a manual determination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Following the recent success in quantitative analysis of essential fatty acid compositions in a commercial microencapsulated fish oil (?EFO) supplement, we extended the application of portable attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopic technique and partial least square regression (PLSR) analysis for rapid determination of total protein contents-the other major component in most commercial ?EFO powders. In contrast to the traditional chromatographic methodology used in a routine amino acid analysis (AAA), the ATR-FTIR spectra of the ?EFO powder can be acquired directly from its original powder form with no requirement of any sample preparation, making the technique exceptionally fast, noninvasive, and environmentally friendly as well as being cost effective and hence eminently suitable for routine use by industry. By optimizing the spectral region of interest and number of latent factors through the developed PLSR strategy, a good linear calibration model was produced as indicated by an excellent value of coefficient of determination R2 = 0.9975, using standard ?EFO powders with total protein contents in the range of 140-450 mg/g. The prediction of the protein contents acquired from an independent validation set through the optimized PLSR model was highly accurate as evidenced through (1) a good linear fitting (R2 = 0.9759) in the plot of predicted versus reference values, which were obtained from a standard AAA method, (2) lowest root mean square error of prediction (11.64 mg/g), and (3) high residual predictive deviation (6.83) ranked in very good level of predictive quality indicating high robustness and good predictive performance of the achieved PLSR calibration model. The study therefore demonstrated the potential application of the portable ATR-FTIR technique when used together with PLSR analysis for rapid online monitoring of the two major components (i.e., oil and protein contents) in finished ?EFO powders in the actual manufacturing setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Detector-based comprehensive screening analysis of complex samples of natural origin using High Performance Liquid Chromatography (HPLC) can be a complicated and time-consuming task. There are a number of ways multidetection characterization can be achieved; however, there are limitations associated with each technique. Active Flow Technology (AFT) in Parallel Segmented Flow (PSF) mode allows for multiplexed detection HPLC analysis within a single injection, whereas maintaining chromatographic performance and allowing the use of multiple destructive detectors to achieve a comprehensive yet efficient screening of a complex sample. In this study, a comprehensive characterization analysis of tobacco leaf extract was carried out through multiplexed detection using a PSF column for the detection of biomolecules by UV-Vis detection, DPPH• for reactive-oxygen species (ROS) detection, and mass spectrometry, the latter two detection methods being sample destructive.