197 resultados para radiotherapy

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To determine whether or not self reported visual functioning and quality of life in patients with choroidal neovascularisation caused by age related macular degeneration (AMD) is better in those treated with 12 Gy external beam radiotherapy in comparison with untreated subjects. Methods: A multicentre single masked randomised controlled trial of 12 Gy of external beam radiation therapy (EBRT) delivered as 6x2 Gy fractions to the macula of an affected eye versus observation. Patients with AMD, aged 60 years or over, in three UK hospital units, who had subfoveal CNV and a visual acuity equal to or better than 6/60 (logMAR 1.0). Methods: Data from 199 eligible participants who were randomly assigned to 12 Gy teletherapy or observation were available for analysis. Visual function assessment, ophthalmic examination, and fundus fluorescein angiography were undertaken at baseline and at 3, 6, 12, and 24 months after study entry. To assess patient centred outcomes, subjects were asked to complete the Daily Living Tasks Dependent on Vision (DLTV) and the SF-36 questionnaires at baseline, 6, 12, and 24 months after enrolment to the study. Cross sectional and longitudinal analyses were conducted using arm of study as grouping variable. Regression analysis was employed to adjust for the effect of baseline co-variates on outcome at 12 months and 24 months. Results: Both control and treated subjects had significant losses in visual functioning as seen by a progressive decline in mean scores in the four dimensions of the DLTV. There were no statistically significant differences between treatment and control subjects in any of dimensions of the DLTV at 12 months or 24 months after study entry. Regression analysis confirmed that treatment status had no effect on the change in DLTV dimensional scores. Conclusions: The small benefits noted in clinical measures of vision in treated eyes did not translate into better self reported visual functioning in patients who received treatment when compared with the control arm. These findings have implications for the design of future clinical trials and studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radical abdominal radiotherapy in men runs the risk of impairing their fertility owing to scattered dose to the testes, outside of the treated volume. In patients for whom this is a concern it is important to be able to predict the dose to the testes before treatment in order to determine whether semen cryopreservation should be undertaken and testicular shielding performed during treatment. Measurements have been made on an anthropomorphic phantom to determine the magnitude of these doses for a four-field treatment consisting of an anterior-posterior parallel pair and a lateral parallel pair. A dataset is presented, which, together with a correction for patients size, allows an estimate of testicular dose to be made given only the photon energy, interfield distances and the distance from the testes to the nearest beam edge. Thermoluminescent dosimetry has been carried out in 17 patients to validate the use of the data tables. The results indicate that testicular doses may be estimated with a standard deviation corresponding to 1%-2% of the tumour dose, which is sufficient for the purpose of determining whether fertility is threatened by a planned treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of intensity modulated radiotherapy (IMRT) to improve the therapeutic ratio in prostate cancer by dose escalation of intraprostatic tumour nodules (IPTNs) was investigated using a simultaneous integrated boost technique. The prostate and organs-at-risk were outlined on CT images from six prostate cancer patients. Positions of IPTNs were transferred onto the CT images from prostate maps derived from sequential large block sections of whole prostatectomy specimens. Inverse planned IMRT dose distributions were created to irradiate the prostate to 70 Gy and all the IPTNs to 90 Gy. A second plan was produced to escalate only the dominant IPTN (DIPTN) to 90 Gy, mimicking current imaging techniques. These plans were compared with homogeneous prostate irradiation to 70 Gy using dose–volume histograms, tumour control probability (TCP) and normal tissue complication probability (NTCP) for the rectum. The mean dose to IPTNs was increased from 69.8 Gy to 89.1 Gy if all the IPTNs were dose escalated (p=0.0003). This corresponded to a mean increase in TCP of 8.7–31.2% depending on the /ß ratio of prostate cancer (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 2-year survival rate after conventional radiotherapy for carcinoma of the oesophagus is around 10–20% [8]. Concomitant chemoradiation schedules have produced survival figures of 25–30% at 5 years, and this is now considered standard treatment [1]. Conformal radiotherapy techniques offer the potential to deliver higher doses of radiation to oesophageal tumours [5], and this may improve local tumour control. However, concerns regarding late normal tissue damage to the lung parenchyma and spinal cord remain a concern. Intensitymodulated radiotherapy (IMRT) allows complex dose distributions to be produced, and can reduce the dose to radiosensitive organs close to the tumour [2]. The present study was designed to investigate the impact of beam intensity modulation on treatment planning for carcinoma of the oesophagus, by comparing a standard three-dimensional conformal radiotherapy (3DCRT) technique to an IMRT technique using the same number and orientation of treatment fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: To investigate the potential of intensity-modulated radiotherapy (IMRT) to reduce lung irradiation in the treatment of oesophageal carcinoma with radical radiotherapy.Materials and methods: A treatment planning study was performed to compare two-phase conformal radiotherapy (CFRT) with IMRT in five patients. The CFRT plans consisted of anterior, posterior and bilateral posterior oblique fields, while the IMRT plans consisted of either nine equispaced fields (9F), or four fields (4F) with orientations equal to the CFRT plans. IMRT plans with seven, five or three equispaced fields were also investigated in one patient. Treatment plans were compared using dose-volume histograms and normal tissue complication probabilities.Results: The 9F IMRT plan was unable to improve on the homogeneity of dose to the planning target volume (PTV), compared with the CFRT plan (dose range, 16.9+/-4.5 (1 SD) vs. 12.4+/-3.9%; P=0.06). Similarly, the 9F IMRT plan was unable to reduce the mean lung dose (11.7+/-3.2 vs. 11.0+/-2.9 Gy; P=0.2). Similar results were obtained for seven, five and three equispaced fields in the single patient studied. The 4F IMRT plan provided comparable PTV dose homogeneity with the CFRT plan (11.8+/-3.3 vs. 12.4+/-3.9%; P=0.6), with reduced mean lung dose (9.5+/-2.3 vs 11.0+/-2.9 Gy; P=0.001).Conclusions: IMRT using nine equispaced fields provided no improvement over CFRT. This was because the larger number of fields in the IMRT plan distributed a low dose over the entire lung. In contrast, IMRT using four fields equal to the CFRT fields offered an improvement in lung sparing. Thus, IMRT with a few carefully chosen field directions may lead to a modest reduction in pneumonitis, or allow tumour dose escalation within the currently accepted lung toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess 3-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques to see whether doses to critical structures could be reduced while maintaining planning target volume (PTV) coverage in patients receiving conventional radiotherapy (RT) for carcinoma of the maxillary sinus because of the risk of radiation-induced complications, particularly visual loss. Six patients who had recently received conventional RT for carcinoma of the maxillary sinus were studied. Conventional RT, 3D-CRT, and step-and-shoot IMRT plans were prepared using the same 2-field arrangement. The effect of reducing the number of segments in the IMRT beams was investigated. 3D-CRT and IMRT reduced the brain and ipsilateral parotid gland doses compared with the conventional plans. IMRT reduced doses to both optic nerves; for the contralateral optic nerve, 15-segment IMRT plans delivered an average maximal dose of 56.4 Gy (range 53.9–59.3) compared with 65.7 Gy (range 65.3–65.9) and 64.2 Gy (range 61.4–65.6) for conventional RT and 3D-CRT, respectively. IMRT also gave improved PTV homogeneity and improved coverage, with an average of 8.5% (range 7.0–11.7%) of the volume receiving

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: Radiotherapy is widely used to palliate local symptoms in non-small-cell lung cancer. Using conventional X-ray simulation, it is often difficult to accurately localize the extent of the tumour. We report a randomized, double blind trial comparing target localization with conventional and virtual simulation.Methods: Eighty-six patients underwent both conventional and virtual simulation. The conventional simulator films were compared with digitally reconstructed radiographs (DRRs) produced from the computed tomography (CT) data. The treatment fields defined by the clinicians using each modality were compared in terms of field area, position and the implications for target coverage.Results: Comparing fields defined by each study arm, there was a major mis-match in coverage between fields in 66.2% of cases, and a complete match in only 5.2% of cases. In 82.4% of cases, conventional simulator fields were larger (mean 24.5+/-5.1% (95% confidence interval)) than CT-localized fields, potentially contributing to a mean target under-coverage of 16.4+/-3.5% and normal tissue over-coverage of 25.4+/-4.2%.Conclusions: CT localization and virtual simulation allow more accurate definition of the target volume. This could enable a reduction in geographical misses, while also reducing treatment-related toxicity.