14 resultados para magnetic separation

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to introduce specificity for Mycobacterium avium subsp. paratuberculosis prior to a phage amplification assay, various magnetic-separation approaches, involving either antibodies or peptides, were evaluated in terms of the efficiency of capture (expressed as a percentage) of M. avium subsp. paratuberculosis cells and the percentage of nonspecific binding by other Mycobacterium spp. A 50:50 mixture of MyOne Tosylactivated Dynabeads coated with the chemically synthesized M. avium subsp. paratuberculosis-specific peptides biotinylated aMp3 and biotinylated aMptD (i.e., peptide-mediated magnetic separation [PMS]) proved to be the best magnetic-separation approach for achieving 85 to 100% capture of M. avium subsp. paratuberculosis and minimal (<1%) nonspecific recovery of other Mycobacterium spp. (particularly if beads were blocked with 1% skim milk before use) from broth samples containing 103 to 104 CFU/ml. When PMS was coupled with a recently optimized phage amplification assay and used to detect M. avium subsp. paratuberculosis in 50-ml volumes of spiked milk, the mean 50% limit of detection (LOD50) was 14.4 PFU/50 ml of milk (equivalent to 0.3 PFU/ml). This PMS-phage assay represents a novel, rapid method for the detection and enumeration of viable M. avium subsp. paratuberculosis organisms in milk, and potentially other sample matrices, with results available within 48 h.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: The objectives of this study were to produce Salmonella-specific peptide ligands by phage display biopanning and evaluate their use for magnetic separation (MS).
Methods and Results: Four phage display biopanning rounds were performed and the peptides expressed by the two most Salmonella-specific (on the basis of phage binding ELISA results) phage clones, MSal020401 and MSal020417, were chemically synthesized and coupled to MyOne™ tosylactivated Dynabeads®. Peptide capture capability for whole Salmonella cells from non-enriched broth cultures was quantified by MS + plate counts and MS + Greenlight™ detection, and compared to capture capability of anti-Salmonella (antibody-coated) Dynabeads®. MS + Greenlight™ gave a more comprehensive picture of capture capability than MS + plate counts and showed that Peptide MSal020417-coated beads exhibited at least similar, if not better, capture capability to anti-Salmonella Dynabeads® (mean capture values of 36.0 ± 18.2 % and 31.2 ± 20.1 %, respectively, over Salmonella spp. concentration range 3 x 101 - 3 x 106 cfu ml-1) with minimal cross-reactivity (= 1.9 %) to three other foodborne bacteria.
Conclusions: One of the phage display-derived peptide ligands was demonstrated by MS + Greenlight™ to be a viable antibody-alternative for MS of Salmonella spp.
Significance and Impact of Study: This study demonstrates an antibody-free approach to Salmonella detection and opens substantial possibilities for more rapid tests for this bacterium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The generation of novel Mycobacterium avium subsp. paratuberculosis (MAP)-specific monoclonal antibodies and phage-display derived peptide binders, along with their application for the magnetic separation (MS) of MAP cells, is described. Our aim was to achieve even greater MAP capture capability than is possible with peptide-mediated magnetic separation (PMS) using a 50:50 mix of biotinylated-aMp3 and biotinylated-aMptD peptide-coated beads. Gamma-irradiated whole MAP cells and ethanol extracted antigens (EEA) from these cells were used to elicit an immune response and as phage-display biopanning targets. A range of novel binders was obtained and coated onto paramagnetic beads, both individually and in various combinations, for MS evaluation. IS900 PCR was employed after MS to provide quick results. Capture sensitivity was assessed using a range of MAP concentrations after which the most promising beads were tested for their specificity for MAP, by performing MS followed by culture using 10 other Mycobacterium species. Magnetic beads coated with the biotinylated EEA402 peptide demonstrated a greater level of MAP capture than the current PMS method, even when low numbers of MAP (<10 cfu/ml) were present; however these beads also captured a range of other mycobacteria and so lacked capture specificity. Magnetic beads coated with monoclonal antibodies 6G11 and 15D10 (used as a 50:50 mix or as dually coated beads) also demonstrated improved MAP capture relative to the current PMS method, but with little cross-reactivity to other Mycobacterium spp. Therefore, two new MS protocols are suggested, the application of which would be dependent upon the required endpoint. Biotinylated EEA402-coated beads could potentially be used with a MAP-specific PCR to ensure detection specificity, while beads coated with 6G11 and 15D10 monoclonal antibodies could be used with culture or the phage amplification assay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study describes further validation of a previously described Peptide-mediated magnetic separation (PMS)-Phage assay, and its application to test raw cows’ milk for presence of viable Mycobacterium avium subsp. paratuberculosis (MAP). The inclusivity and exclusivity of the PMS-phage assay were initially assessed, before the 50% limit of detection (LOD50) was determined and compared with those of PMS-qPCR (targeting both IS900 and f57) and PMS-culture. These methods were then applied in parallel to test 146 individual milk samples and 22 bulk tank milk samples from Johne’s affected herds. Viable MAP were detected by the PMS-phage assay in 31 (21.2%) of 146 individual milk samples (mean plaque count of 228.1 PFU/50 ml, range 6-948 PFU/50 ml), and 13 (59.1%) of 22 bulk tank milks (mean plaque count of 136.83 PFU/50 ml, range 18-695 PFU/50 ml). In contrast, only 7 (9.1%) of 77 individual milks and 10 (45.4%) of 22 bulk tank milks tested PMS-qPCR positive, and 17 (11.6%) of 146 individual milks and 11 (50%) of 22 bulk tank milks tested PMS-culture positive. The mean 50% limits of detection (LOD50) of the PMS-phage, PMS-IS900 qPCR and PMS-f57 qPCR assays, determined by testing MAP-spiked milk, were 0.93, 135.63 and 297.35 MAP CFU/50 ml milk, respectively. Collectively, these results demonstrate that, in our laboratory, the PMS-phage assay is a sensitive and specific method to quickly detect the presence of viable MAP cells in milk. However, due to its complicated, multi-step nature, the method would not be a suitable MAP screening method for the dairy industry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims: The objective of this study was to develop a novel screening method for detection of viable Mycobacterium avium subsp. paratuberculosis (Map) in milk and faeces, as a rapid alternative to Map culture.
Methods and results: The new method couples Map-specific peptide-mediated magnetic separation technique with an optimised phage amplification assay followed by detection of released progeny phage by ELISA in a competition assay format using polyclonal antibody produced against the D29 mycobacteriophage involved in the phage assay. Sample matrices were found not to interfere with the developed method and the dynamic range of the assay was 3 X 102 – 6 X 108 phage ml-1. When low numbers of Map were present (102 CFU ml-1) the burst size of a single host Map cell was maximal (103 phage per cell) resulting in a highly sensitive screening assay.
Conclusion: A rapid, sensitive immuno-based screening method suitable for the detection of viable Map in milk and faeces was developed.
Significance and impact of study: The novel PMS-phage-ELISA permits sensitive, qualitative detection of viable Map in milk or faeces samples within 48 h, representing a substantial decrease in time to detection compared to current culture methods for Map.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Gold-coated magnetic nanoparticles were synthesized with size ranging from 15 to 40 nm using sodium citrates as the reducing agent. Oxidized magnetites (Fe3O4) fabricated by co-precipitation of Fe2+ and Fe3+ in strong alkaline solution were used as magnetic cores. The structures of gold (Au) shell and magnetic core (Au–Fe) were studied by transmission electron microscopy (TEM) image and energy dispersive spectroscopy (EDS) spectrum. Results from high-resolution X-ray diffraction (HR XRD) show that the Au–Fe oxide nanoparticles have a face-centered cubic shape with the crystalline faces of {1 1 1}. The Au-coated magnetic nanoparticles exhibited a surface plasmon resonance peak at 528 nm. The nanoparticles are well dispersed in distilled water. A 3000 G permanent magnet was successfully used for the separation of the functionalized nanoparticles. Magnetic properties of the nanoparticles were determined by magnetic force microscope (MFM) in nanometric resolution and vibrating sample magnetometer (VSM). Magnetic separation of biological molecules using Au-coated magnetic oxide composite nanoparticles was examined after attachment of protein immunoglobulin G (IgG) through electrostatic interactions. Using this method, separation was achieved with a maximum yield of 35% at an IgG concentration of 400 ng/ml.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There is interest in determining levels of Mycobacterium avium subsp. paratuberculosis (MAP) contamination in milk. The optimal sample preparation for raw cows' milk to ensure accurate enumeration of viable MAP by the peptide-mediated magnetic separation (PMS)-phage assay was determined. Results indicated that milk samples should be refrigerated at 4 C after collection and MAP testing should commence within 24 h, or samples can be frozen at 70 C for up to one month without loss of MAP viability. Use of Bronopol is not advised as MAP viability is affected. The vast majority (>95%) of MAP in raw milk sedimented to the pellet upon centrifugation at 2500 g for 15 min, so this milk fraction should be tested. De-clumping of MAP cells was most effectively achieved by ultrasonication of the resuspended milk pellet on ice in a sonicator bath at 37 kHz for 4 min in ‘Pulse’ mode.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Motion of single micrometer-sized magnetic particles on patterned magnetic surfaces is controlled by a rotating magnetic field (see Figure and cover). Patterns of thin-film magnetic elements are tailored to form transport lines. Individual particles are separated by adding junctions to the transport lines. The method can improve existing applications in biotechnology and generate new ones in life sciences.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Au nanoparticles (AuNPs) have been widely used not only as optical labels or ‘weight” labels for the detections of biorecognition events but also an amplifier of surface plasmon resonance biosensors. The intrinsic property of gold nuclei composing of a group of Au atoms to catalyze the reduction of metal ions on the NPs and thereby to enlarge the metallic nanoparticles is employed in different biosensing paths. In a solution containing Au+ ions (e.g. HAuCl4) and the Au clusters, hydrated electrons which are reduced from oxidation of reducers (H2O2, sodium citrate, ascorbic acid, or NaBH4) will be used to reduce the Au+ ion leading to the deposition of Au+ to the Au0 (Au clusters). The reaction will be catalyzed continuously by the Au0 until the Au+ ions and hydrated electrons are exhausted. As a result, the AuNPs will be grown and their optical properties are also changed. If the AuNP nanoclusters are used as probes, the color change will be dependent on amount of analytes, thus give a quantitative monitoring of the analytes.

In this study, we incorporate the use of magnetic beads with the nanocrystalline growth to quantify a target protein based on immunoreactions. Prostate specific antigen (PSA) is chosen as the target analyte because of its values in diagnosis of prostate cancer. A double-sandwiched immunoassay is performed by gold-tagged monoclonal PSA antibody-PSA antigen – magnetic bead-tagged polyclonal PSA antibody interactions. After the immunoreactions, the target analytes are preconcentrated and separated by the magnetic beads while the nanogrowth plays a role of colorimetric signal developer.

The result shows that this is a very sensitive, robust and excellent strategy to detect biological interactions. PSA antigen is detected at femtomolar level with very high specificity under the presence of undesired proteins of crude samples. Furthermore, the method also shows great potential to detect other biological interactions. More details will be described in our presentation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Perovskite phase instability of BiMnO3 has been exploited to synthesize epitaxial metal oxide magnetic nanocrystals. Thin film processing conditions are tuned to promote the breakdown of the perovskite precursor into Bi2O3 matrix and magnetic manganese oxide islands. Subsequent cooling in vacuum ensures complete volatization of the Bi2O3, thus leaving behind an array of self-assembled magnetic Mn3O4 nanostructures. Both shape and size can be systematically controlled by the ambient oxygen environments and deposition time.As such, this approach can be extended to any other Bi-based complex ternary oxide system as it primarily hinges on the breakdown of parent Bi-based precursor and subsequent Bi2O3 volatization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High cadence, multiwavelength, optical observations of a solar active region, obtained with the Swedish Solar Telescope, are presented. Two magnetic bright points are seen to separate in opposite directions at a constant velocity of 2.8 km s(-1). After a separation distance of approximate to 4400 km is reached, multiple Ellerman bombs are observed in both Ha and Ca-K images. As a result of the Ellerman bombs, periodic velocity perturbations in the vicinity of the magnetic neutral line, derived from simultaneous Michelson Doppler Imager data, are generated with amplitude +/-6 km s(-1) and wavelength approximate to 1000 km. The velocity oscillations are followed by an impulsive brightening visible in Ha and Ca-K, with a peak intensity enhancement of 63%. We interpret these velocity perturbations as the magnetic field deformation necessary to trigger forced reconnection. A time delay of approximate to 3 minutes between the Ha-wing and Ca-K observations indicates that the observed magnetic reconnection occurs at a height of similar to 200 km above the solar surface. These observations are consistent with theoretical predictions and provide the first observational evidence of microflare activity driven by forced magnetic reconnection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The system TlCo2Se2-xSx has been thoroughly investigated by neutron powder diffraction and SQUID magnetometry. TlCo2Se2-xSx is a layered tetragonal structure containing atomic cobalt layers separated by a distance of 6.4 angstrom in the sulphide and 6.8 angstrom in the selenide. The solid solubility of isovalent selenium and sulphur atoms in the structure makes it possible to continuously vary the interlayer distance and thereby tune the magnetic coupling between the Co-layers. At low temperatures, the Co-atoms are ferromagnetically ordered within the layers and magnetic moments lie in the ab-plane. However, these Co-moments form a helical magnetic structure that prevails for 0 <= x <= 1.5 with a gradual decrease of the angle between adjacent Co-layers from 122 degrees to 39 degrees. For x >= 1.75, a collinear ferromagnetic structure is stable. The relationship between the coupling angle and the Co-interlayer separation shows an almost linear behaviour. The helical phase contains no net spontaneous magnetic moment up to TlCo2SeS, where a small net magnetic moment appears that increases until the ferromagnetic structure is found for 1.75 <= x <= 2.0. (C) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The phase instability of bismuth perovskite (BiMO3), where M is a ferromagnetic cation, is exploited to create self-assembled magnetic oxide nanocrystal arrays on oxide supports. Conditions during pulsed laser deposition are tuned so as to induce complete breakdown of the perovskite precursor into bismuth oxide (Bi2 O3 ) and metal oxide (M-Ox ) pockets. Subsequent cooling in vacuum volatizes the Bi2 O3 leaving behind an array of monodisperse nanocrystals. In situ reflective high energy electron diffraction beam is exploited to monitor the synthesis in real-time. Analysis of the patterns confi rms the phase separation and volatization process. Successful synthesis of M-Ox, where M = Mn, Fe, Co, and Cr, is shown using this template-free facile approach. Detailed magnetic characterization of nanocrystals is carried out to reveal the functionalities such as magnetic anisotropy as well as larger than bulk moments, as expected in these oxide nanostructures.