8 resultados para second degree relative

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim and objectives. To identify maternal, newborn and obstetric factors associated with birth-related perineal trauma in one independent birth centre. Background. Risk factors for birth-related perineal trauma include episiotomy, maternal age, ethnicity, parity and interventions during labour including use of oxytocin, maternal position at time of birth and infant birth weight. Understanding more about these factors could support the management of vaginal birth to prevent spontaneous perineal trauma, in line with initiatives to reduce routine use of episiotomy. Design. Cross-sectional study. Methods. Data were retrospectively collected from one independent birth centre in Brazil, during 20062009. The dependent variable (perineal trauma) was classified as: (1) intact perineum or first-degree laceration, (2) second-degree laceration and (3) episiotomy (right mediolateral or median). Results. There were 1079 births during the study period. Parity, use of oxytocin during labour, position at time of giving birth and infant birth weight were associated with second-degree lacerations and episiotomies. After adjusting for parity, oxytocin, maternal position at the expulsive stage of labour and infant birth weight influenced perineal outcomes among primiparae only. Conclusions. Although the overall rate of episiotomies in this study was low compared with national data, it was observed that younger women were most vulnerable to this intervention. In this age group in particular, the use of oxytocin as well as semi-upright positions at the time of birth was associated with second-degree lacerations and episiotomies. Relevance to clinical practice. The use of upright alternative positions for birth and avoidance of use of oxytocin could reduce the risk of perineal trauma from lacerations and need to perform episiotomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Invasive species are potential threats to biodiversity, especially if they become established and outnumber native species. In this study, a population of the non-indigenous crab Charybdis hellerii was analyzed in an estuary-bay complex on the southeastern Brazilian coast, with respect to its abundance relative to sympatric native brachyuran species, as well as the size structure, sexual maturity, sex ratio, frequency of mutilation, reproductive period, and development of the reproductive system. Crabs were sampled monthly both in the intertidal zone of rocky shores and on sublittoral soft-bottom. Nine species were recorded on the rocky shores, where C. hellerii was the second most abundant species; only three individuals of C. hellerii were collected in the sublittoral samples. This population of C. hellerii showed a unimodal size structure composed mainly of mature individuals; males were larger than females, and the sex ratio was skewed toward males (3.1:1). About 46.9% of the individuals (75 of 160 crabs) had mutilated or regenerating appendages, more frequent in males (56.8%) than in females (28.2%), which may reflect both inter- and intraspecific agonistic interactions. A continuous reproductive pattern is suggested for this population, although ovigerous females occurred unevenly during the year, with 58.82% of them being collected in winter. There was evidence of multiple spawning, since the ovigerous females with an initial egg mass showed mature ovaries as well as seminal receptacles filled with sperm. C. hellerii is well established in the estuary-bay complex, but is concentrated in intertidal and shallow subtidal rocky shores, where it may compete with and replace other species such as the portunid Cronius ruber. This study also highlights the importance of systematic monitoring studies to evaluate the effects of the introduction of non-indigenous species on ecologically similar natives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The properties of films of carboxymethyl cellulose, CMC, of different degree of substitution, DS, have been examined by the use of perichromic indicators (probes). The film properties that have been determined are: empirical polarity, E-T(33); "acidity", alpha; "basicity", beta; and dipolarity/polarizability, pi*. This has been achieved by employing the following perichromic probes: 4-nitroaniline, 4-nitroanisole, 4-nitro-N,N-dimethylaniline, and 2,6-dichloro-4-(2,4,6-triphenyl-pyridinium-1-yl)phenolate, WB. The correlations between both E-T(33)- or pi* and DS were found to be linear; that between beta and DS is a second order polynomial; no obvious correlation was found between alpha and DS. The polarities of CMC films are in the range of those of butyl alcohols. As models for CMC, we have employed cellulose plus CMC of high DS; oxidized cellulose with degree of oxidation = 0.5; sodium glucuronate. The former model behaved akin to CMC, but the plots of the perichromic properties versus DS showed different slopes/intercepts. FTIR data and molecular dynamics simulations on the solvation of WB have shown that this difference can be traced to more efficient hydrogen bonding between the film of the model and the probe. This affects the intra-molecular charge-transfer energy of the latter, leading to different responses to the variation of DS. Based on the excellent linear correlation between E-T(33) and DS, for CMC from different origins, we suggest that perichromism is a simple, accurate, and expedient alternative for the determination of DS of the biopolymer derivative.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). Material and methods: Filtek (TM) Z350 nanofilled composite resins and Amelogen (R) Plus, Vit-l-escence (TM) and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free Light (TM) 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm(-1)) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). Results: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey's test showed that the nanofilled resin (Filtek (TM) Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (Filtek (TM) Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free Light (TM) 2). Conclusions: The nanofilled resin showed the lowest DC, and the Vit-l-escence (TM) microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: This study evaluated the degree of conversion (DC) and working time (WT) of two commercial, dual-cured resin cements polymerized at varying temperatures and under different curing-light accessible conditions, using Fourier transformed infrared analysis (FTIR). Materials and Methods: Calibra (Cal; Dentsply Caulk) and Variolink II (Ivoclar Vivadent) were tested at 25 degrees C or preheated to 37 degrees C or 50 degrees C and applied to a similar-temperature surface of a horizontal attenuated-total-reflectance unit (ATR) attached to an infrared spectrometer. The products were polymerized using one of four conditions: direct light exposure only (600 mW/cm(2)) through a glass slide or through a 1.5- or 3.0-mm-thick ceramic disc (A2 shade, IPS e.max, Ivoclar Vivadent) or allowed to self-cure in the absence of light curing. FTIR spectra were recorded for 20 min (1 spectrum/s, 16 scans/spectrum, resolution 4 cm(-1)) immediately after application to the ATR. DC was calculated using standard techniques of observing changes in aliphatic-to-aromatic peak ratios precuring and 20-min postcuring as well as during each 1-second interval. Time-based monomer conversion analysis was used to determine WT at each temperature. DC and WT data (n=6) were analyzed by two-way analysis of variance and Tukey post hoc test (p=0.05). Results: Higher temperatures increased DC regardless of curing mode and product. For Calibra, only the 3-mm-thick ceramic group showed lower DC than the other groups at 25 degrees C (p=0.01830), while no significant difference was observed among groups at 37 degrees C and 50 degrees C. For Variolink, the 3-mm-thick ceramic group showed lower DC than the 1-mm-thick group only at 25 degrees C, while the self-cure group showed lower DC than the others at all temperatures (p=0.00001). WT decreased with increasing temperature: at 37 degrees C near 70% reduction and at 50 degrees C near 90% for both products, with WT reduction reaching clinically inappropriate times in some cases (p=0.00001). Conclusion: Elevated temperature during polymerization of dual-cured cements increased DC. WT was reduced with elevated temperature, but the extent of reduction might not be clinically acceptable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a simultaneous optical signal-to-noise ratio (OSNR) and differential group delay (DGD) monitoring method based on degree of polarization (DOP) measurements in optical communications systems. For the first time in the literature (to our best knowledge), the proposed scheme is demonstrated to be able to independently and simultaneously extract OSNR and DGD values from the DOP measurements. This is possible because the OSNR is related to maximum DOP, while DGD is related to the ratio between the maximum and minimum values of DOP. We experimentally measured OSNR and DGD in the ranges from 10 to 30 dB and 0 to 90 ps for a 10 Gb/s non-return-to-zero signal. A theoretical analysis of DOP accuracy needed to measure low values of DGD and high OSNRs is carried out, showing that current polarimeter technology is capable of yielding an OSNR measurement within 1 dB accuracy, for OSNR values up to 34 dB, while DGD error is limited to 1.5% for DGD values above 10 ps. For the first time to our knowledge, the technique was demonstrated to accurately measure first-order polarization mode dispersion (PMD) in the presence of a high value of second-order PMD (as high as 2071 ps(2)). (C) 2012 Optical Society of America

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose of this study was to evaluate the influence of miniscrew dental root proximity on its late stability degree. 40 miniscrews were inserted between maxillary second premolars and first molars for anterior retraction. Post-surgical radiographs were used to measure the septum width in the insertion site, insertion height, distal and mesial distance from miniscrew to dental root, and the smallest distance between miniscrew and dental root. The miniscrews were divided in two groups according to septum width: ?3 mm (20 miniscrews) and >3 mm (20 miniscrews). The soft tissue in the insertion site, sensitivity during load, plaque around the miniscrew, and evaluation period were also considered. The results showed no significant difference in miniscrew mobility degree and success rate between groups. Miniscrew dental root proximity did not influence the stability and success rate when the distance between the miniscrew and dental root indicated no periodontal ligament invasion. The overall success rate was 90% and no variable was associated with miniscrew failure. Nevertheless, patient sensitivity was frequently associated with some degree of mini-implant mobility. The septum width did not influence the stability and success rate of this anchorage system, but the extreme root proximity did.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to assess the degree of multicollinearity and to identify the variables involved in linear dependence relations in additive-dominant models. Data of birth weight (n=141,567), yearling weight (n=58,124), and scrotal circumference (n=20,371) of Montana Tropical composite cattle were used. Diagnosis of multicollinearity was based on the variance inflation factor (VIF) and on the evaluation of the condition indexes and eigenvalues from the correlation matrix among explanatory variables. The first model studied (RM) included the fixed effect of dam age class at calving and the covariates associated to the direct and maternal additive and non-additive effects. The second model (R) included all the effects of the RM model except the maternal additive effects. Multicollinearity was detected in both models for all traits considered, with VIF values of 1.03 - 70.20 for RM and 1.03 - 60.70 for R. Collinearity increased with the increase of variables in the model and the decrease in the number of observations, and it was classified as weak, with condition index values between 10.00 and 26.77. In general, the variables associated with additive and non-additive effects were involved in multicollinearity, partially due to the natural connection between these covariables as fractions of the biological types in breed composition.