6 resultados para dental device

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to determine the influence of thickness and aging on the intrinsic fluorescence of sealing materials and their ability to block fluorescence from the underlying surface as assessed using a laser fluorescence device. Cavities of 0.5 mm and 1 mm depth were drilled into acrylic boards which were placed over two surfaces with different fluorescence properties: a low-fluorescence surface, to assess the intrinsic fluorescence of the sealing materials, and a high-fluorescence surface, to assess the fluorescence-blocking ability of the sealing materials. Ten cavities of each depth were filled with different sealing materials: Adper Scotchbond Multi-Purpose, Adper Single Bond 2, FluroShield, Conseal f and UltraSeal XT Plus. Fluorescence was measured with a DIAGNOdent pen at five different time points: empty cavity, after polymerization, and 1 day, 1 week and 1 month after filling. The individual values after polymerization, as well as the area under the curve for the different periods were submitted to ANOVA and the Tukey test (p < 0.05). At 0.5 mm, Scotchbond, FluroShield and UltraSeal showed insignificant changes in intrinsic fluorescence with aging and lower fluorescence after polymerization than Single Bond and Conseal. At 1 mm, Scotchbond and FluroShield showed the lowest intrinsic fluorescence, but only Scotchbond showed no chagnes in fluorescence with aging. At both depths, Scotchbond blocked significantly less fluorescence. All sealing materials blocked more fluorescence when applied to a depth of 1 mm. At 0.5 mm, fissure sealants blocked more fluorescence than adhesives, and did not show significant changes with aging. Scotchbond had the least affect on the fluorescence from the underlying surface and would probably have the least affect on the monitoring of sealed dental caries by laser fluorescence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Felypressin has been added to local anesthetic to increase the length of the anesthetic effect and reduce toxicity during dental procedures. However, the effect on blood pressure remains uncertain, and this may be highly relevant in the dental treatment of hypertensive patients. Objective: To investigate the effect of felypressin on blood pressure in hypertensive patients with controlled BP. Methods: 71 subjects with these characteristics and in need of periodontal treatment were studied. After 10 minutes of rest, local anesthesia (prilocaine) was infiltrated with and without addition of felypressin. Then, a deep subgingival scaling was performed. Blood pressure was measured by an automated oscillometric device (DIXTAL DX2010). Ten minutes after the administration of the anesthetic, peak anesthetic action was recorded. The State-Trait Anxiety Inventory (STAI) was used to assess the patients' trait anxiety. Results: Systolic blood pressure increased after anesthesia, regardless of association with felypressin, throughout the dental procedure (p<0.05) and this response can be explained, at least in part, by the trait anxiety levels of the subjects. However, a further increase in diastolic blood pressure was observed when prilocaine was associated with felypressin (p<0.05), but this response did not change with trait anxiety levels. Conclusion: Felypressin increased the diastolic blood pressure of hypertensive patients with controlled blood pressure. Patients with high trait anxiety presented increases in systolic blood pressure upon some procedures, suggesting that an increase in blood pressure might also be related to fear or anxiety. (Arq Bras Cardiol 2012;99(2):724-731)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of dental plaque and moisture on performance of a laser fluorescence device in detecting occlusal and proximal caries lesions in primary teeth. Fifty-five occlusal and 58 proximal sites on primary molars were evaluated using a DIAGNOdent pen (LFpen) device. For the drying time study, the evaluations were performed in: (I) moist teeth; (II) teeth dried for 3 s, or (III) dried for 15 s. For the plaque study, the evaluations were done in sites: (I) without plaque; (II) with plaque, and (III) after cleaning. Evaluation of the teeth sections in stereomicroscope was the reference standard method. LF pen values, sensitivity, specificity, and accuracy were compared. The values obtained after 15 s of drying were higher than those obtained with moist teeth or dried for 3 s at both occlusal and proximal surfaces. However, there was no change in the performance in detecting caries lesions. With regard to the presence of plaque, there was no significant change in the readings of the device, but specificity was decreased in occlusal surfaces with plaque. At proximal surfaces, however, no significant differences were observed. In conclusion, the moisture conditions do not influence significantly the performance of the LFpen, but the presence of plaque can affect its performance in detecting occlusal caries lesions in primary teeth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Implant-abutment connections still present failures in the oral cavity due to the loosening of mechanical integrity by detorque and corrosion of the abutment screws. The objective of this study was to evaluate the detorque of dental abutment screws before and after immersion in fluoridated solutions. Materials and Methods: Five commercial implant-abutment assemblies were assessed in this investigation: (C) Conex˜aoR , (E) EmfilsR , (I) INPR , (S) SINR , and (T) Titanium FixR . The implants were embedded in an acrylic resin and then placed in a holding device. The abutments were first connected to the implants and torqued to 20Ncmusing a handheld torque meter. The detorque values of the abutments were evaluated after 10 minutes. After applying a second torque of 20 Ncm, implant-abutment assemblies were withdrawn every 3 hours for 12 hours in a fluoridated solution over a period of 90 days. After that period, detorque of the abutments was examined. Scanning electronicmicroscopy (SEM) associated to energy dispersive spectroscopy (EDS) was applied to inspect the surfaces of abutments. Results: Detorque values of systems C, E, and I immersed in the fluoridated solution were significantly higher than those of the initial detorque. ANOVA demonstrated no significant differences in detorque values between designs S and T. Signs of localized corrosion could not be detected by SEM although chemical analysis by EDS showed the presence of elements involved in corrosive processes. Conclusion: An increase of detorque values recorded on abutments after immersion in fluoridated artificial saliva solutions was noticed in this study. Regarding chemical analysis, such an increase of detorque can result from a corrosion layer formed between metallic surfaces at static contact in the implant-abutment joint during immersion in the fluoridated solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To verify the presence and degree of asymmetry of dental arches in Brazilian individuals with natural normal occlusion and Class II, Divisions 1 and 2 malocclusions. METHODS: The study evaluated the symmetry of the maxillary and mandibular dental arches of 180 pairs of dental casts, divided into: Group I = 60 pairs of natural normal occlusion individuals; Group II = 60 pairs of Class II, Division 1 malocclusion individuals; and Group III = 60 pairs of Class II, Division 2 malocclusion individuals. A device was used to measure dental midline deviation and the canine tip in the dental arches (in degrees). It was also verified the distance of the upper canines from the palatal suture, intercanine distance, and anteroposterior upper and lower first molar position. RESULTS: Dental arches of individuals from all groups presented asymmetry, regardless of the presence of malocclusion. Group I showed a lower asymmetry degree in relation to Groups II and III. The asymmetry in Groups II and III was similar. CONCLUSION: The dental arches of individuals with natural normal occlusion and with Class II, Division 1 and Division 2 malocclusions showed asymmetry. The asymmetry degree was higher in the mandibular dental arches than in the maxillary dental arches in all 3 evaluated groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Among the sleep disorders reported by the American Academy of Sleep, the most common is obstructive sleep apnea-hypopnea syndrome (OSAHS), which is caused by difficulties in air passage and complete interruption of air flow in the airway. This syndrome is associated with increased morbidity and mortality in apneic individuals. OBJECTIVE: It was the objective of this paper to evaluate a removable mandibular advancement device as it provides a noninvasive, straightforward treatment readily accepted by patients. METHODS: In this study, 15 patients without temporomandibular disorders (TMD) and with excessive daytime sleepiness or snoring were evaluated. Data were collected by means of: Polysomnography before and after placement of an intraoral appliance, analysis of TMD signs and symptoms using a patient history questionnaire, muscle and TMJ palpation. RESULTS: After treatment, the statistical analysis (t-test, and the "before and after" test) showed a mean reduction of 77.6% (p=0.001) in the apnea-hypopnea index, an increase in lowest oxyhemoglobin saturation (p=0.05), decrease in desaturation (p=0.05), decrease in micro-awakenings or EEG arousals (p=0.05) and highly significant improvement in daytime sleepiness (p=0.005), measured by the Epworth Sleepiness Scale. No TMD appeared during the monitoring period. CONCLUSION: The oral device developed in this study was considered effective for mild to moderate OSAHS.