Influence of dental materials used for sealing caries lesions on laser fluorescence measurements


Autoria(s): Celiberti, Paula; Carvalho, Thiago Saads; Raggio, Daniela Prócida; Mendes, Fausto Medeiros
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

21/10/2013

21/10/2013

2012

Resumo

The aim of this study was to determine the influence of thickness and aging on the intrinsic fluorescence of sealing materials and their ability to block fluorescence from the underlying surface as assessed using a laser fluorescence device. Cavities of 0.5 mm and 1 mm depth were drilled into acrylic boards which were placed over two surfaces with different fluorescence properties: a low-fluorescence surface, to assess the intrinsic fluorescence of the sealing materials, and a high-fluorescence surface, to assess the fluorescence-blocking ability of the sealing materials. Ten cavities of each depth were filled with different sealing materials: Adper Scotchbond Multi-Purpose, Adper Single Bond 2, FluroShield, Conseal f and UltraSeal XT Plus. Fluorescence was measured with a DIAGNOdent pen at five different time points: empty cavity, after polymerization, and 1 day, 1 week and 1 month after filling. The individual values after polymerization, as well as the area under the curve for the different periods were submitted to ANOVA and the Tukey test (p < 0.05). At 0.5 mm, Scotchbond, FluroShield and UltraSeal showed insignificant changes in intrinsic fluorescence with aging and lower fluorescence after polymerization than Single Bond and Conseal. At 1 mm, Scotchbond and FluroShield showed the lowest intrinsic fluorescence, but only Scotchbond showed no chagnes in fluorescence with aging. At both depths, Scotchbond blocked significantly less fluorescence. All sealing materials blocked more fluorescence when applied to a depth of 1 mm. At 0.5 mm, fissure sealants blocked more fluorescence than adhesives, and did not show significant changes with aging. Scotchbond had the least affect on the fluorescence from the underlying surface and would probably have the least affect on the monitoring of sealed dental caries by laser fluorescence.

Identificador

LASERS IN MEDICAL SCIENCE, LONDON, v. 27, n. 2, supl. 1, Part 3, pp. 287-295, MAR, 2012

0268-8921

http://www.producao.usp.br/handle/BDPI/35300

10.1007/s10103-010-0856-z

http://dx.doi.org/10.1007/s10103-010-0856-z

Idioma(s)

eng

Publicador

SPRINGER LONDON LTD

LONDON

Relação

LASERS IN MEDICAL SCIENCE

Direitos

closedAccess

Copyright SPRINGER LONDON LTD

Palavras-Chave #DENTAL ADHESIVE #FISSURE SEALANT #LASER FLUORESCENCE #DIAGNODENT PEN #INTRINSIC FLUORESCENCE #OCCLUSAL CARIES #APPROXIMAL CARIES #FISSURE SEALANTS #IN-VITRO #CLINICAL-PERFORMANCE #ADHESIVE RESINS #DEVICE #PENETRATION #DIAGNODENT #DIAGNOSIS #ENGINEERING, BIOMEDICAL #SURGERY
Tipo

article

original article

publishedVersion