805 resultados para wooless lamb


Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>The Cayenne tick Amblyomma cajennense infests preferably horses in its adult form but other mammal species in its immature stages and is the main vector of Rickettsia rickettsii, the Brazilian spotted fever pathogen. As wooless lambs are often raised on pasture together with horses, an experiment was performed to investigate their possible acquisition of resistance to A. cajennense after experimental infestations. Seven naive wooless lambs were infested thrice at 60 days interval with immature and adult instars of A. cajennense from a laboratory colony, the tick biotic potential being determined and biopsies of tick bite lesions taken to investigate the inflammatory cell component. Nearly 100% of larvae died in all infestations, while nymphs and adults fed normally throughout re-infestations. Microscopic features of adult tick bite lesions revealed predominance of neutrophils (38%) and eosinophils (36.8%), respectively, in the first and second infestations. In the third infestation, 43.6% of MN cells were found and about 31% of eosinophils. on the other hand, nymph bite lesions revealed in all infestations a predominance of eosinophils, increasing from 36% in the first infestation to 50.5% in the third one. It is concluded that wooless lambs present remarkable innate resistance against larvae of A. cajennense, but marked susceptibility to the other tick instars despite the migration of great number of eosinophils to the tick lesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Burn injury is associated with disabling scar formation which impacts on many aspects of the patient's life. Previously we have shown that the fetus heals a deep dermal burn in a scarless fashion. Amniotic membrane (AM) is the outermost fetal tisue and has beeen used as a dressing in thermal injuries, though there is little data to support this use. To assess the efficacy of AM in scar minimisation after deep dermal burn wound, we conducted a randomised controlled study in the 1-month lamb. Lambs were delivered by caesarian section and the amniotic membranes stored after which lambs were returned to their mothers post-operatively. At 1 month, a standardised deep dermal burn was created under general anaesthesia on both flanks of the lamb. One flank was covered with unmatched AM, the other with paraffin gauze. Animals were sequentially euthanased from Day 3-60 after injury and tissue analysed for histopathology and immunohistochemically for alpha-smooth muscle actin (alphaSMA) content. AM resulted in reduced scar tissue as assessed histopathologically and reduced alphaSMA content. This study provides the first laboratory evidence that AM may reduce scar formation after burn injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, experimental and numerical investigations have been conducted to explore the possibility of using A0 mode in Lamb waves to detect the position of delamination in carbon fiber reinforced plastic (CFRP) laminated beams. An experimental technique for exciting and sensing the pure A0 mode has been developed. By measuring the propagation speed of A0 mode and traveling time of a signal reflected from the delamination, its location can be identified experimentally and numerically. Moreover, the numerical analysis has been extended to gain a better understanding of the complex interaction between A0 mode and a long delamination case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Petrifilm(R) (6410) was used directly on lamb carcasses to enumerate coliforms. 10 sites on 30 carcasses were sampled at each of 4 separate meat processing establishments (works). Coliform counts obtained by this technique were statistically analysed using analysis of variance (ANOVA) to select the optimum sampling sites on the carcass and to assess contamination of the carcass by gut flora at a particular establishment. There was a large variation between sites and between works. In general, works 3 and 4 produced cleaner carcasses than works 2, which in turn was cleaner than works 1. Works 1, 2 and 4 used conventional dressing techniques and works 3 used the inverted dressing method, therefore, the coliform counts found at works 3 and 4 are achievable regardless of dressing technique. Coliform bacteria were most concentrated around the posterior pelvic rim and less prevalent at the carcass extremities. The posterior pelvic rim (sites 3 and 4) had higher (P < 0.05) coliform counts than the exterior ventral flank area (sites 5, 6, 7 and 8), which in turn had higher (P < 0.05) counts than the proximal hind and proximal fore limbs (sites 1, 2, 9 and 10) across all works. With in-line routine testing it is recommended that the majority of carcasses sampled should give coliform counts of <50 cfu/20 cm2 for sites 4 and 8. Reprinted with permission from Journal of Food Protection. Copyright held by the International Association of Food Protection, Des Moines, Iowa, USA. Authors affifiation. J.A.Guthrie & K.J.Dunlop International Food Institute of Queensland, Department of Primary Industries, Rockhampton and G.A.Saunders Veterinary Public Health Division, Livestock and Meat Authority of Queensland, Emerald.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to assess the structural reliability of bridges, an accurate and cost effective Non-Destructive Evaluation (NDE) technology is required to ensure their safe and reliable operation. Over 60% of the Australian National Highway System is prestressed concrete (PSC) bridges according to the Bureau of Transport and Communication Economics (1997). Most of the in-service bridges are more than 30 years old and may experience a heavier traffic load than their original intended level. Use of Ultrasonic waves is continuously increasing for (NDE) and Structural Health Monitoring (SHM) in civil, aerospace, electrical, mechanical applications. Ultrasonic Lamb waves are becoming more popular for NDE because it can propagate long distance and reach hidden regions with less energy loses. The purpose of this study is to numerically quantify prestress force (PSF) of (PSC) beam using the fundamental theory of acoustic-elasticity. A three-dimension finite element modelling approach is set up to perform parametric studies in order to better understand how the lamb wave propagation in PSC beam is affected by changing in the PSF level. Results from acoustic-elastic measurement on prestressed beam are presented, showing the feasibility of the lamb wave for PSF evaluation in PSC bridges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time reversal active sensing using Lamb waves is investigated for health monitoring of a metallic structure. Experiments were conducted on an aluminum plate to study the time reversal behavior of A(0) and S-0 Lamb wave modes under narrow band and broad band pulse excitation. Damage in the form of a notch was introduced in the plate to study the changes in the characteristics of the time reversed Lamb wave modes experimentally. Time-frequency analysis of the time reversed signal was carried out to extract the damage information. A measure of damage based on wavelet transform was derived to quantify the hidden damage information in the time reversed signal. It has been shown that time reversal can be used to achieve temporal recompression of Lamb waves under broadband signal excitation. Further, the broad band excitation can also improve the resolution of the technique in detecting closely located defects. This is demonstrated by picking up the reflection of waves from the edge of the plate, from a defect close to the edge of the plate and from defects located near to each other. This study shows the effectiveness of Lamb wave time reversal for temporal recompression of dispersive Lamb waves for damage detection in health monitoring applications. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A damage detection and imaging methodology based on symmetry of neighborhood sensor path and similarity of signal patterns with respect to radial paths in a circular array of sensors has been developed It uses information regarding Limb wave propagation along with a triangulation scheme to rapidly locate and quantify the severity of damage without using all of the sensor data. In a plate like structure, such a scheme can be effectively employed besides full field imaging of wave scattering pattern from the damage, if present in the plate. This new scheme is validated experimentally. Hole and corrosion type damages have been detected and quantified using the proposed scheme successfully. A wavelet based cumulative damage index has been studied which shows monotonic sensitivity against the severity of the damage. which is most desired in a Structural Health Monitoring system. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A circular array of Piezoelectric Wafer Active Sensor (PWAS) has been employed to detect surface damages like corrosion using lamb waves. The array consists of a number of small PWASs of 10 mm diameter and 1 mm thickness. The advantage of a circular array is its compact arrangement and large area of coverage for monitoring with small area of physical access. Growth of corrosion is monitored in a laboratory-scale set-up using the PWAS array and the nature of reflected and transmitted Lamb wave patterns due to corrosion is investigated. The wavelet time-frequency maps of the sensor signals are employed and a damage index is plotted against the damage parameters and varying frequency of the actuation signal (a windowed sine signal). The variation of wavelet coefficient for different growth of corrosion is studied. Wavelet coefficient as function of time gives an insight into the effect of corrosion in time-frequency scale. We present here a method to eliminate the time scale effect which helps in identifying easily the signature of damage in the measured signals. The proposed method becomes useful in determining the approximate location of the corrosion with respect to the location of three neighboring sensors in the circular array. A cumulative damage index is computed for varying damage sizes and the results appear promising.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose a concept and report experimental results based on a circular array of Piezoelectric Wafer Active Sensors (PWASs) for rapid localization and parametric identification of corrosion type damage in metallic plates. Implementation of this circular array of PWASs combines the use of ultrasonic Lamb wave propagation technique and an algorithm based on symmetry breaking in the signal pattern to locate and monitor the growth of a corrosion pit on a metallic plate. Wavelet time-frequency maps of the sensor signals are employed to obtain an insight regarding the effect of corrosion growth on the Lamb wave transmission in time-frequency scale. We present here a method to eliminate the time scale, which helps in identifying easily the signature of damage in the measured signals. The proposed method becomes useful in determining the approximate location of the damage with respect to the location of three neighboring sensors in the circular array. A cumulative damage index is computed from the wavelet coefficients for varying damage sizes and the results appear promising. Damage index is plotted against the damage parameters for frequency sweep of the excitation signal (a windowed sine signal). Results of corrosion damage are compared with circular holes of various sizes to demonstrate the applicability of present method to different types of damage. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stiffener is one of the major components of aircraft structures to increase the load carrying capacity. Damage in the stiffener, mostly in the form of crack is an unavoidable problem in aerospace structures. Stiffener is bonded to the inner side of the aircraft panel which is not accessible for immediate inspection. A sensor-actuator network can be placed on the outer side of the panel that is accessible. Ultrasonic lamb waves are transmitted through stiffener using the sensoractuator network for detecting the presence of damages. The sensor-actuator network is placed on both halves of the stiffened section on the accessible surface of the plate. Detecting damage in stiffener by using this technique has significant potential for SHM technology. One of the major objectives of the present work is to determine the smallest detectable crack on the stiffener using the proposed technique. Wavelet based damage parameter correlation studies are carried out. In the proposed scheme, with increase in the damage size along the stiffener, it is found that the amplitude of the received signal decreases monotonically. The advantage of this technique is that the stiffened panels need not be disassembled in a realistic deployment of SHM system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Damage detection using guided Lamb waves is an important tool in Structural health Monitoring. In this paper, we outline a method of obtaining Lamb wave modes in composite structures using two dimensional Spectral Finite Elements. Using this approach, Lamb wave dispersion curves are obtained for laminated composite structures with different fibre orientation. These propagating Lamb wave modes are pictorially captured using tone burst signal.