514 resultados para wearing
Resumo:
Women wearing peace aprons during Peace march in Brisbane, Australia 1963. Cars can be seen in the background.
Resumo:
P>Background There is good evidence for the use of compression for some clinical indications but little is known about dosimetry in compression. Objective The aim of this work was to evaluate whether or not the use of compression stockings during part of the day would help in the reduction of evening oedema in patients with clinical, epidemiological, anatomical and physiopathological (CEAP) classifications C0 and C1. Methods The effects of elastic compression stockings on volumetric variations during the working day were evaluated for the legs of two men and 18 women (40 legs). The inclusion criterion was classification as C0 (10 legs) or C1 (30 legs) according to the CEAP criteria. Participants used three-quarter-length elastic compression stockings (20-30 mmHg) on three consecutive days for the entire day or only for the morning or they did not use the stockings at all. Volumetry using the water displacement technique was performed in the morning and in the evening. When the patients wore the stockings only during the morning, volumetry was also performed at 13:00 h. Results Significant increases in volume were observed for both legs when stockings were not used compared with the use of stockings in the morning only. After removing the stockings, both legs had significant increases in volume in the afternoon. However, use for half the day was better than not using the stockings at all. Conclusions The use of elastic compression stockings can reduce volumetric variations during working hours, with the use of stockings for the entire day being better than for just half the day.
Resumo:
Work-related falls continues to be one of the leading causes of fatalities in the Australian construction industry, and the failure to use fall protection equipment, such as fall-arrest harnesses and arresting devices, has been found to be a contributing factor. In an attempt to gain an understanding of the issues surrounding the use of fallarrest harness systems by construction workers a study involving semi-structured interviews of 15 male construction workers was carried out at three construction sites. The majority of interviewees commented that there was discomfort in wearing a fall-arrest harness; that there were a number of problems when anchored via an arresting device; and that using a fall-arrest system reduced productivity. Most of the interviewees considered that they needed safety precautions against falls, and they expressed the view that workers’ attitudes towards safety depended critically upon their supervisors’ attitude towards safety. It was also found that workers were not trained in rescue procedures. Interviewees expressed concern that retrieval of a suspended worker may not be carried out in time to prevent the onset of suspension trauma. A number of issues were identified which require further research, such as, investigation into suspension trauma, harness and arresting device design, training provided to workers, and the provision for rescues.
Resumo:
Purpose: To quantify the effect of unstable shoe wearing on muscle activity and haemodynamic response during standing. Methods: Thirty volunteers were divided into 2 groups: the experimental group wore an unstable shoe for 8 weeks, while the control group used a conventional shoe for the same period. Muscle activity of the medial gastrocnemius, tibialis anterior, rectus femoris and biceps femoris and venous circulation were assessed in quiet standing with the unstable shoe and barefoot. Results: In the first measurement there was an increase in medial gastrocnemius activity in all volunteers while wearing the unstable shoe. On the other hand, after wearing the unstable shoe for eight weeks these differences were not verified. Venous return increased in subjects wearing the unstable shoe before and after training. Conclusions: The unstable shoe produced changes in electromyographic characteristics which were advantageous for venous circulation even after training accommodation by the neuromuscular system.
Resumo:
This study investigated the influence of wearing unstable shoe construction (WUS) on compensatory postural adjustments (CPA) associated with external perturbations. Thirty-two subjects stood on a force platform resisting an anterior-posterior horizontal force applied to a pelvic belt via a cable, which was suddenly released. They stood under two conditions: barefoot and WUS. The electromyographic (EMG) activity of gastrocnemius medialis, tibialis anterior, rectus femoris, biceps femoris, rectus abdominis, and erector spinae muscles and the center of pressure (CoP) displacement were acquired to study CPA. The EMG signal was used to assess individual muscle activity and latency, antagonist co-activation and reciprocal activation at joint and muscle group levels. Compared to barefoot, WUS led to: (1) increased gastrocnemius medialis activity, (2) increased total agonist activity, (3) decreased antagonist co-activation at the ankle joint and muscle group levels, (4) increased reciprocal activation at the ankle joint and muscle group levels, and (5) decrease in all muscle latencies. No differences were observed in CoP displacement between conditions. These findings demonstrate that WUS led to a reorganization of the postural control system associated to improved performance of some components of postural control responses.
Resumo:
Purpose: This study investigated the influence of long-term wearing of unstable shoes (WUS) on compensatory postural adjustments (CPA) to an external perturbation. Methods: Participants were divided into two groups: one wore unstable shoes while the other wore conventional shoes for 8 weeks. The ground reaction force signal was used to calculate the anterior– posterior (AP) displacement of the centre of pressure (CoP) and the electromyographic signal of gastrocnemius medialis (GM), tibialis anterior (TA), rectus femoris (RF) and biceps femoris (BF) muscles was used to assess individual muscle activity, antagonist co-activation and reciprocal activation at the joint (TA/GM and RF/(BF + GM) pairs) and muscle group levels (ventral (TA + RF)/dorsal (GM + BF) pair) within time intervals typical for CPA. The electromyographic signal was also used to assess muscle latency. The variables described were evaluated before and after the 8-week period while wearing the unstable shoes and barefoot. Results: Long-term WUS led to: an increase of BF activity in both conditions (barefoot and wearing the unstable shoes); a decrease of GM activity; an increase of antagonist co-activation and a decrease of reciprocal activation level at the TA/GM and ventral/dorsal pairs in the unstable shoe condition. Additionally, WUS led to a decrease in CoP displacement. However, no differences were observed in muscle onset and offset. Conclusion: Results suggest that the prolonged use of unstable shoes leads to increased ankle and muscle groups’ antagonist co-activation levels and higher performance by the postural control system.
Resumo:
Objective: To study the influence of prolonged wearing of unstable shoes on standing postural control in prolonged standing workers. Methods: The participants were divided into two groups: one wore unstable shoes while the other wore conventional shoes for 8 weeks. Stabilometry parameters related to centre of pressure (CoP), rambling (RM) and trembling (TR) as well as the total agonist/antagonist muscle activity, antagonist co-activation and reciprocal activation were evaluated during upright standing, before and after the 8 week period. In both moments, the subjects were evaluated wearing the unstable shoes and in barefoot. Results: The unstable shoe condition presented increased CoP displacement related variables and decreased co-activation command compared to barefoot before and after the intervention. The prolonged wearing of unstable shoes led to: (1) reduction of medial-lateral CoP root mean square and area; (2) decreased anteroposterior RM displacement; (3) increased anteroposterior RM mean velocity and mediolateral RM displacement; (4) decreased anteroposterior TR RMS; and (5) increased thigh antagonist co-activation in the unstable shoe condition. Conclusion: The unstable shoe condition is associated to a higher destabilizing effect that leads to a selection of more efficient and accurate postural commands compared to barefoot. Prolonged wearing of unstable shoes provides increased effectiveness and performance of the postural control system, while wearing of unstable shoes in upright standing, that are reflected by changes in CoP related variables and by a reorganization of postural control commands.
Resumo:
PURPOSES: To determine the level of compliance and major non-compliant behaviors in contact lens (CL) wearing medical doctors (MDs) and to compare it with age matched CL wearing normal subjects with no medical background (NS). METHODS: Thirty-nine current CL wearing MDs, who were prescribed CLs in Nepal Eye Hospital, Kathmandu, Nepal, between 2007 and 2011, were interviewed on ten modifiable compliant behaviors regarding lens care and maintenance. The level of compliance and the rate of non-compliance for each behavior were determined and compared with NS. RESULTS: Level of compliance was good, average and poor in 35.9%, 48.7% and 15.4% of MDs, respectively. There was no significant difference in compliance between MDs and NS (p=0.209). Level of compliance was not associated with age, gender and duration of lens wear (p>0.05). Compliance rate varied according to different behaviors, achieving a good compliance level of 95% for hand hygiene, avoidance of water contact and not sleeping with lenses. There was poor compliance for topping up solution (53.8%) and lens case replacement (15.4%). CONCLUSION: About one third of MDs had a good level of compliance. Level of compliance and compliance rate of different behaviors were similar in MDs and NS. Periodic lens case replacement was the most neglected behavior in CL wearers for this region.
Resumo:
Résumé Introduction : La conjonctivite giganto-papillaire chez des patients porteurs de lentilles de contact survient lors d'une intolérance et/ou d'une allergie aux lentilles de contact. L'éotaxine est un CC chémokine produisant un puissant effet chémotactique sur les éosinophiles, qui sont impliqués dans les allergies. Le but de cette étude est de mesurer le taux d'éotaxine dans les larmes de patients porteurs de lentilles de contact et de le comparer à celui de sujets normaux. Les taux d'éotaxine sont également corrélés avec le degré de conjonctivite giganto-papillaire. Méthode : Environ 10 Ill de larmes ont été collectés avec une rnicropipette en verre chez 16 patients porteurs de lentilles de contact et chez 10 volontaires normaux. La conjonctivite giganto-papillaire a été évaluée selon une échelle de 0 à 4 en référence à des images photographiques de la paupière supérieure réalisées à la lampe à fente. La concentration de l'éotaxine dans les larmes a été mesurée par un ELISA utilisant un anticorps d'éotaxine de souris dirigé contre l'anticorps humain. Pour l'analyse statistique des résultats, le test de Wilcox/Kruskal-Wallis a été utilisé. Résultats : La concentration moyenne d'éotaxine était de 2698 +233 (SEM) pg/ml chez les patients porteurs de lentilles de contact et de 1498 139 pg/ml chez les sujets normaux. La différence était statistiquement significative avec P = 0.0004. Le score moyen des papilles était de 1.75 ±0.19 chez les patients porteurs de lentilles de contact et de 0.2 +0.13 chez les sujets normaux (P <0.0001). Le grading des papilles a pu être mis en relation avec le taux d'éotaxine dans les larmes (R2- 0.6562 avec P <0.0001). Conclusion : Une augmentation du taux d'éotaxine dans les larmes a été mesurée chez les patients porteurs de lentilles de contact. Les taux d'éotaxine ont été corrélés avec la sévérité de la conjonctivite giganto-papillaire. Ces données suggèrent que l'éotaxine pourrait jouer un rôle important dans la formation des papilles. Abstract : Purpose: Giant papillary conjunctivitis in patients wearing contact lenses occurs after intolerance and/or allergy to contact lenses. Eotaxin is a CC chemokine with a potent and specific chemotactic effect for eosinophils, which are involved in allergies. The purpose of this study is to measure the eotaxin levels in tears of patients wearing contact lenses and in normal subjects. Eotaxin levels were also correlated with the grade of giant papillary conjunctivitis. Methods: Around 10µL of tears were collected with glass capillaries in 16 patients wearing contact lenses and in 10 normal volunteers. Giant papillary conjunctivitis was graded from 0 to 4 by reference to standard slit-lamp photographs of the superior tarsal conjunctiva. Eotaxin concentration in tears was measured by ELSA using mouse anti-human eotaxin monoclonal antibodies. For the statistical analysis of the results, the paired Wilcoxon/Kruskai-Wallis test was used. Results: The mean concentration of eotaxin was 2698 ± 233 (SEM) pg/mL in patients wearing contact lenses and 1498 ± 139 pg/mL normal subjects. The difference was statistically significant (P =0.0004). The mean score of papilla grade was 1.75 ± 0.19 in patients wearing contact lenses and 01 ± 0.13 in normal subjects (P < 0.0001). Papilla grade could be correlated to the eotaxin level in tears (R2 = 0.6562 and P< 0.0001), Conclusion: An increase of eotaxin levels in tears was measured in patients wearing contact lenses. Eotaxin levels correlated with the severity of giant papillary conjunctivitis. These data suggest that eotaxin could play a role in papilla formation.
Resumo:
This report presents the results of the largest and most comprehensive study to date on portland cement pervious concrete (PCPC). It is designed to be widely accessible and easily applied by designers, producers, contractors, and owners. The project was designed to begin with pervious concrete best practices and then to address the unanswered questions in a systematic fashion to allow a successful overlay project. Consequently, the first portion of the integrated project involved a combination of fundamental material property investigations, test method development, and addressing constructability issues before actual construction could take place. The second portion of the project involved actual construction and long-term testing before reporting successes, failures, and lessons learned. The results of the studies conducted show that a pervious concrete overlay can be designed, constructed, operated, and maintained. A pervious concrete overlay has several inherent advantages, including reduced splash and spray and reduced hydroplaning potential, as well as being a very quiet pavement. The good performance of this overlay in a particularly harsh freeze-thaw climate, Minnesota, shows pervious concrete is durable and can be successfully used in freeze-thaw climates with truck traffic and heavy snow plowing.
Resumo:
BACKGROUND: Eotaxin-1 (CCL11) is a potent eosinophil chemotactic and activating peptide that may be implicated in the pathogenesis of chronic allergic eye disease and has been associated with the wearing of contact lenses (CL) in patients with contact lens papillary conjunctivitis (CLPC). The purpose of this study was to study eotaxin-1 expression in the tears of long-term CL wearers. PATIENTS AND METHODS: Tears were collected with glass capillaries from 15 patients (2 male, 13 female) with various degree of CLPC at 2-year intervals. CLPC severity was graded from 0 to 4 with reference to standard slit-lamp photographs of the superior tarsal conjunctiva. The eotaxin-1 level in the tears was measured by an ELISA, using mouse anti-human eotaxin monoclonal antibodies. RESULTS: The mean age was 32.5 ± 13.3 years (range: 17 - 69 years). The mean interval between the tear collections was 30 ± 4.8 months. The mean concentration of eotaxin was 2150 ± 477 pg/mL and 2486 ± 810 pg/mL for the first and second series, respectively. The difference was not statistically significant (paired Wilcoxon/Kruskal-Wallis, p = 0.803). The mean score of papilla grade was 1.26 ± 0.18 for the first sample and 1.40 ± 0.19 two years later. There was no significant difference of grading between the two time periods (paired Wilcoxon/Kruskal-Wallis, p = 0.751). CONCLUSIONS: the eotaxin-1 level remains up-regulated over a long time period in patients wearing CL, most of them with chronic CLPC. Eotaxin may play a role in the pathogenesis of contact lens intolerance.
Resumo:
A coloured card of a lady wearing a bonnet and cloak. On the back it says C.D. Fredericks & Co., 587 Broadway, New York; 108 Calle de Habana, Habana, and 31 Passage du Havre, Paris.
Resumo:
L’augmentation de la population âgée dans la société indique que les systèmes de soins de la santé font face à de nouveaux défis. Les hauts niveaux d’incapacité qui en résultent peuvent être réduits par les nouvelles technologies, la promotion de la santé ainsi que des stratégies de prévention. Les écrits scientifiques récents soulignent la supériorité des prothèses dentaires implanto-portées par rapport aux prothèses conventionnelles en termes de satisfaction et de qualité de la vie des patients. Cependant, il n'est toujours pas clair si ces avantages ont des effets positifs à long terme sur la santé orale et générale ainsi que sur la qualité de vie des populations âgées. Objectifs, Hypothèses : Notre but était de mesurer l’impact des prothèses mandibulaires retenues par 2 implants sur la qualité de vie associée à la santé bucco-dentaire et générale ainsi que sur la santé orale et la qualité du sommeil des aînés édentés. Nous avons évalué les hypothèses nulles suivantes : il n'y a aucune différence entre les individus portants des prothèses mandibulaires retenues par 2 implants (IODs) et ceux qui portent des prothèses conventionnelles (CDs), par rapport à la qualité de vie reliée à la santé bucco-dentaire et générale, la santé orale et la qualité du sommeil, un an après avoir reçu leurs nouvelles prothèses. Méthodes : Dans cette étude randomisée contrôlée, 255 aînés ont reçu au hasard IODs ou les CDs, les deux types de prothèses étant opposés à des prothèses maxillaires conventionnelles. La qualité de la vie reliée à la santé bucco-dentaire (OHRQoL) et la santé générale subjective ont été mesurées avec les questionnaires Oral Health Impact Profile (OHIP-20) et Short Form-36 (SF-36) en condition pré-traitement et après un an. La qualité du sommeil et la somnolence diurne ont été mesurées à l’aide du questionnaire Qualité de Sommeil de Pittsburg et de l'Échelle de Somnolence Epworth. La santé orale a été évaluée par un examen clinique. Les variables indépendantes étaient le sens de cohérence et le type de prosthèse, ainsi que des variables socio-démographiques. En utilisant des analyses statistiques bi et multi-factorielles, des comparaisons à l’intérieur d’un même groupe et entre deux groupes ont été effectuées. Résultats : Les différences pré et post traitement pour les cotes OHIP étaient significativement plus grandes pour le groupe IOD que le groupe CD (p<0.05). Le type de traitement et la cote pré-traitement étaient des facteurs significatifs à OHRQoL (p < 0.0001). Dans le groupe CD, il y avait une diminution significative par rapport aux cotes de «Physical Component Scores (PCS)», le fonctionnement physique, le rôle physique et la douleur physique entre les données pré-traitement et un an après le traitement, ce qui indique une diminution au niveau de la santé générale subjective. Dans le groupe IOD, une diminution statistiquement non significative a été remarquée par rapport à toutes les cotes des sous-échelles de SF-36, sauf pour la douleur physique. Le modèle final de régression a démontré qu’après ajustement pour les variables âge, sexe, statut marital et type de traitement, la cote totale finale d’OHIP et les données de bases de PCS prédisaient la cote finale de PCS (p < 0.0001). Aucune corrélation significative entre sens de cohérence et OHRQoL n'a été détectée (r =-0.1; p > 0.05). Les aînés porteurs des prothèses conventionnelles avaient presque 5 fois plus de chance d’avoir une stomatite prothétique que ceux portant des prothèses mandibulaires hybrides retenues par 2 implants (p < 0.0001). Les aînés ayant subjectivement une mauvaise santé générale avaient une qualité de sommeil moins bonne que ceux avec une meilleure santé générale subjective (p < 0.05). Les personnes qui avaient une OHRQoL moins bonne étaient presque 4 fois plus somnolentes pendant le jour que celles avec une meilleure OHRQoL (p=0.003, χ2; OR =3.8 CI 1.5 to 9.8). L'analyse de régression a montré que la santé générale subjective et OHRQoL prévoient la qualité du sommeil (p=0.022 et p=0.001, respectivement) et la somnolence diurne (p=0.017 et p=0.005, respectivement). Conclusions: Les résultats de cette étude suggèrent que, chez les aînés édentés, des prothèses mandibulaires hybrides retenues par deux implants amènent une amélioration significative de la qualité de vie reliée à la santé bucco-dentaire et maintiennent la sensation d’une meilleure santé physique. Des prothèses hybrides implanto-portées peuvent contribuer à la santé orale en réduisant les traumatismes infligés à la muqueuse orale et en contrôlant la stomatite prothétique. Les aînés édentés dont le niveau de qualité de vie reliée à la santé bucco-dentaire est bas, peuvent aussi avoir des troubles de qualité du sommeil.
Resumo:
La supériorité des prothèses mandibulaires retenues par deux implants (IODs) sur les prothèses conventionnelles (CDs) nécessitent d’être éclaircies notamment en rapport à leur influence sur la qualité de vie reliée à la santé bucco-dentaire (OHRQoL) ainsi que sur la stabilité de cet effet de traitement. De plus, l’influence des facteurs psychologiques, tel que le sens de cohérence (SOC), sur l’effet de traitement reste encore inconnue. Le but de cette étude est de déterminer l’amplitude de l’influence du port des IODs et des CDs sur l’OHRQoL et d’évaluer la stabilité de l’effet de traitement dans le temps, tout en prenant en considération le niveau du SOC. MÉTHODOLOGIE: Des participants édentés (n=172, âge moyen 71, SD = 4.5) ayant reçu des CDs ou des IODs ont été suivis sur une période de deux ans. L’OHRQoL a été évaluée à l’aide du questionnaire « Oral Health Impact Profile (OHIP -20) » et ce avant le traitement et à chacun des deux suivis. Le SOC a été évalué à l’aide du questionnaire « The Orientation to Life (SOC -13) » à chacun des deux suivis. Des analyses statistiques ont été effectuées pour évaluer les différences intra et entre groupes (analyses statistiques descriptives, bivariées et multivariées). RÉSULTATS: Une amélioration statistiquement significative de l’OHRQoL entre les statuts avant et après traitement a été notée dans les deux groupes (Wilks’s Lambda = 0.473, F (1,151) = 157.31, p < 0.0001). L’amplitude de l’effet du traitement IOD est 1.5 fois plus grande que celle du traitement CD. Ces résultats ont été stables pendant les deux années d’étude et ils n’ont pas été influencés par le SOC. CONCLUSION: Le traitement IOD amène une meilleure OHRQoL à long terme en comparaison avec le traitement CD et ce sans influence du niveau du SOC. Ces résultats sont cliniquement significatifs et confirment la supériorité des IODs sur les CDs.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)