974 resultados para water supply network
Resumo:
With the service life of water supply network (WSN) growth, the growing phenomenon of aging pipe network has become exceedingly serious. As urban water supply network is hidden underground asset, it is difficult for monitoring staff to make a direct classification towards the faults of pipe network by means of the modern detecting technology. In this paper, based on the basic property data (e.g. diameter, material, pressure, distance to pump, distance to tank, load, etc.) of water supply network, decision tree algorithm (C4.5) has been carried out to classify the specific situation of water supply pipeline. Part of the historical data was used to establish a decision tree classification model, and the remaining historical data was used to validate this established model. Adopting statistical methods were used to access the decision tree model including basic statistical method, Receiver Operating Characteristic (ROC) and Recall-Precision Curves (RPC). These methods has been successfully used to assess the accuracy of this established classification model of water pipe network. The purpose of classification model was to classify the specific condition of water pipe network. It is important to maintain the pipeline according to the classification results including asset unserviceable (AU), near perfect condition (NPC) and serious deterioration (SD). Finally, this research focused on pipe classification which plays a significant role in maintaining water supply networks in the future.
Resumo:
Known as one of the ten most important advances on Public Health in the 20th century, fluoridation of public water supply is a measure of wide population coverage, which is effective on caries control. The city of Araçatuba, in the Northwest region of the São Paulo state, Brazil, started public water supply fluoridation in 1972 and, based on the average annual highest temperature, has kept the fluoride concentration between 0.6 to 0.8 mgF/L. The purpose of this study was to analyze monthly the fluoride concentration in public water supply in the city of Araçatuba during 72 months. Water samples were collected monthly on weekdays, directly from the water distribution network, on pre-established locations and analyzed in duplicate between November 2004 and October 2010 at the Research Laboratory of the Nucleus for Public Health (NEPESCO) of the Public Health Graduate Program from Araçatuba Dental School/UNESP, Brazil, using an fluoride-specific electrode connected to an ion analyzer. From the total of samples (n=591), 67.2% (n=397) presented fluoride concentration between 0.6 and 0.8 mgF/L; 20.6% (n=122) below 0.6 mgF/L; 11.5% (n=68) between 0.8 and 1.2 mgF/L and 0.7% (n=4) above 1.2 mgF/L. Most samples showed fluoride levels within the recommended parameters. Minimal variation was observed among the analyzed collection locations, showing that the city has been able to control the fluoride levels in the public water supply and reinforcing the importance of surveillance and constant monitoring to assure the quality of the water delivered to the population.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper presents a study on the implementation of Real-Time Pricing (RTP) based Demand Side Management (DSM) of water pumping at a clean water pumping station in Northern Ireland, with the intention of minimising electricity costs and maximising the usage of electricity from wind generation. A Genetic Algorithm (GA) was used to create pumping schedules based on system constraints and electricity tariff scenarios. Implementation of this method would allow the water network operator to make significant savings on electricity costs while also helping to mitigate the variability of wind generation.
Resumo:
This paper presents a study on the implementation of Real-Time Pricing (RTP) based Demand Side Management (DSM) of water pumping at a clean water pumping station in Northern Ireland, with the intention of minimising electricity costs and maximising the usage of electricity from wind generation. A Genetic Algorithm (GA) was used to create pumping schedules based on system constraints and electricity tariff scenarios. Implementation of this method would allow the water network operator to make significant savings on electricity costs while also helping to mitigate the variability of wind generation.
Resumo:
This paper presents a study on the implementation of Real-Time Pricing (RTP) based Demand Side Management (DSM) of water pumping at a clean water pumping station in Northern Ireland, with the intention of minimising electricity costs and maximising the usage of electricity from wind generation. A Genetic Algorithm (GA) was used to create pumping schedules based on system constraints and electricity tariff scenarios. Implementation of this method would allow the water network operator to make significant savings on electricity costs while also helping to mitigate the variability of wind generation.
Resumo:
This paper presents major findings from a recent study aiming to systematically determine suitable river sections for local domestic water supply along the Yangtze River in Jiangsu Province, China. On the basis of analysis on the current riverbank utilization and bank stability, accessible and stable river sections in the region were selected. The water quality in these river sections was then studied using a two-dimensional unsteady flow and pollutant transport/transformation model, RBFVM-2D. The model was calibrated and verified against the hydrodynamic data, water quality data and remote sensing data collected from the river. The investigation on the pollution sources along the river identified 56 main pollution point sources. The pollution zones downstream of these point sources are the main threat for the water quality in the river. The model was used to compute the pollution zones. In particular, simulations were conducted to establish the relationship between the extent of the pollution zone and the wastewater discharge rate of the associated point source. These water quality simulation results were combined with the riverbank stability analysis to determine suitable river sections for local domestic water supply.
Resumo:
Nine cases of melioidosis with four deaths occurred over a 28-month period in members of a small remote Aboriginal community in the top end of the Northern Territory of Australia. Typing by pulsed-field gel electrophoresis showed isolates of Burkholderia pseudomallei from six of the cases to be clonal and also identical to an isolate from the community water supply, but not to soil isolates. The clonality of the isolates found in this cluster contrasts with the marked genetic diversity of human and environmental isolates found in this region which is hyperendemic for B. pseudomallei. It is possible that the clonal bacteria persisted and were propagated in biofilm in the water supply system. While the exact mode of transmission to humans and the reasons for cessation of the outbreak remain uncertain, contamination of the unchlorinated community water supply is a likely explanation.
Resumo:
During the second half of 1986 the impact of the improvement of water supply and excreta disposal facilities on diarrheal diseases and intestinal parasitosis was studied in 254 children up to six years of age from two favelas (shanty towns) of Belo Horizonte, Brazil. The estimated incidence of diarrhea was 6.2 episodes/child year and the estimated period prevalence reached 31.0 episode days/ child/ year. The point prevalence of parasitosis was 70.7% (Ascaris lumbricoides: 55.4%, Trichuris trichiura: 19.6%, Giardia lamblia: 17.9%). The estimated prevalence of diarrhea decreased with improvement of water supply and sanitation facilities to 45% and 44% respectively, but no statistically significant impact was observed in the case of parasitosis. School education and weaning practice were found to be other important determinants of diarrhea.
Resumo:
Infiltration galleries are among the oldest known means used for small public water fountains. Owing to its ancestral origin they are usually associated with high quality water. Thirty-one compounds, including pesticides and estrogens from different chemical families, were analysed in waters from infiltration galleries collected in Alto Douro Demarcated Wine region (North of Portugal). A total of twelve compounds were detected in the water samples. Nine of these compounds are described as presenting evidence or potential evidence of interfering with the hormone system of humans and wildlife. Although concentrations of the target analytes were relatively low, many of them below their limit of quantification, four compounds were above quantification limit and two of them even above the legal limit of 0.1 lg/L: dimethoate (30.38 ng/L), folpet (64.35 ng/L), terbuthylazine-desethyl (22.28 to 292.36 ng/L) and terbuthylazine (22.49 to 369.33 ng/L).
Resumo:
Magdeburg, Univ., Fak. für Maschinenbau, Diss., 2014
Resumo:
In this study, the results obtained in a control programme of schistosomiasis in Ravena (Sabará, Minas Gerais) between 1980 and 1992 are evaluated. Control measures used in this programme were: specific treatment of the people infected with Schistosoma mansoni at four year-intervals (1980/84/88) and the supply of tap water to 90% of the residences in 1980. A significant reduction of the prevalence (36.7% to 11.5%, p < 0.05) and of the intensity of the infection (228.9 eggs per gram of feces (epg), s = 3.7 to 60.3 epg, s = 3.5, p < 0.05) was observed. No cases of the severe form of the disease were diagnosed in the area. Factors independently associated with the infection were in 1980 daily sand extraction and the lack of tap water in residences and in 1992 daily sand extraction and fishing and weekly swimming. Concluding, the supply of tap water together with quadrennial treatments significantly diminished both the prevalence and intensity of the S. mansoni infection, with the additional gain of persistent low indices even after four-year intervals between the treatments.
Resumo:
This master’s thesis is focused on power supply network disturbances and their effects on the frequency converter – one of the components of modern process crane electrical system. The most critical disturbance types, their causes and the effect they bring to crane electrical system was determined in this work. Variety of protective devices used for mitigation of disturbances is investigated. Device protection solutions for the frequency converter used in crane applications are presented. Analyses of the power supply requirements for frequency converter and various components of crane electrical system were carried out and as a result the crane power supply requirements list that guarantees normal crane operation was built. This list is to be included in crane projects for troubleshooting purposes in order to determine potentially dangerous network.