998 resultados para wastewater discharge


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project assessed the potential impact of untreated sewage release in a near-shore marine environment of Antarctica through the distribution and characterisation of the faecal indicator bacteria Enterococcus. Antibiotic resistance and genome sequencing analyses revealed that enterococci resistant to multiple antibiotics closely related to clinical pathogens were introduced to the pristine Antarctic environment by Australia's Davis station.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Problem of water scarcity has been increasingly severe in China. Though industrial sectors play important role for the rapid economic growth, and they consumes water and discharge wastewater. The purpose of this study is to examine the efficiency of water use and wastewater discharge in comparison with those of other inputs and production output in Chinese industry. Measuring efficiency of each input and output factor from 2002 to 2008, we find the average inefficiencies of industrial water use and industrial wastewater discharge are higher than those of capital, labor, and production output in China. In addition, the productivity levels to save water in the water shortage areas are not higher compared to the others. The water use inefficiency has a high dispersion especially in the regions where the amounts of water resources per capita is less than 3000 cubic meter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the 2009/2010 summer, a comprehensive environmental impact assessment (EIA) of the wastewater discharge at Davis Station, East Antarctica was completed. As part of this, histological alteration of gill and liver tissue in Antarctic Rock-cod (Trematomus bernacchii) from four sites along a spatial gradient from the wastewater outfall were assessed. All fish within 800 m of the outfall exhibited significant histological changes in both tissues. Common pathologies observed in fish closest to the outfall include proliferation of epithelial cells with associated secondary lamellar fusion in the gills and multifocal granulomata with inflammation and necrosis as well as cysts in the liver. Fish from sites >800 m from the outfall also exhibited alterations but to a lesser degree, with prevalence and severity decreasing with increasing distance from the outfall. This study highlights the value of histopathological investigations as part of EIAs and provides the first evidence of sub-lethal alteration associated with wastewater discharge in East Antarctica.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The properties and toxicity of untreatedwastewater at Davis Station, East Antarctica,were investigated to inform decisions regarding the appropriate level of treatment for local discharge purposes and more generally, to better understand the risk associated with dispersal and impact of wastewaters in Antarctica. Suspended solids, nutrients (nitrogen, phosphorus), biological oxygen demand (BOD), metals, organic contaminants, surfactants and microbiological load were measured at various locations throughout the wastewater discharge system. Wastewater quality and properties varied greatly between buildings on station, each ofwhich has separate holding tanks. Nutrients, BOD and settleable solid levelswere higher than standard municipal wastewaters. Microbiological loads were typical of untreated wastewater. Contaminants detected in the wastewater included metals and persistent organic compounds, mainly polybrominated diphenyl ethers (PBDEs). The toxicity of wastewater was also investigated in laboratory bioassays using two local Antarctic marine invertebrates, the amphipod Paramoera walkeri and the microgastropod Skenella paludionoides. Animals were exposed to a range of wastewater concentrations from3% to 68% (test 1) or 63% (test 2) over 21 days with survival monitored daily. Significant mortality occurred in all concentrations of wastewater after 14 to 21 days, and at higher concentrations (50–68% wastewater) mortality occurred after only one day. Results indicate that the local receiving marine environment at Davis Station is at risk from existing wastewater discharges, and that advanced treatment is required both to remove contaminants shown to cause toxicity to biota, as well as to reduce the environmental risks associated with non-native micro-organisms in wastewater.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Point sources of wastewater pollution, including effluent from municipal sewage treatment plants and intensive livestock and processing industries, can contribute significantly to the degradation of receiving waters (Chambers et al. 1997; Productivity Commission 2004). This has led to increasingly stringent local wastewater discharge quotas (particularly regarding Nitrogen, Phosphorous and suspended solids), and many municipal authorities and industry managers are now faced with upgrading their existing treatment facilities in order to comply. However, with high construction, energy and maintenance expenses and increasing labour costs, traditional wastewater treatment systems are becoming an escalating financial burden for the communities and industries that operate them. This report was generated, in the first instance, for the Burdekin Shire Council to provide information on design aspects and parameters critical for developing duckweed-based wastewater treatment (DWT) in the Burdekin region. However, the information will be relevant to a range of wastewater sources throughout Queensland. This information has been collated from published literature and both overseas and local studies of pilot and full-scale DWT systems. This report also considers options to generate revenue from duckweed production (a significant feature of DWT), and provides specifications and component cost information (current at the time of publication) for a large-scale demonstration of an integrated DWT and fish production system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Actualment, la legislació ambiental ha esdevingut més restrictiva pel que fa a la descàrrega d'aigües residuals amb nutrients, especialment en les anomenades àrees sensibles o zones vulnerables. Arran d'aquest fet, s'ha estimulat el coneixement, desenvolupament i millora dels processos d'eliminació de nutrients. El Reactor Discontinu Seqüencial (RDS) o Sequencing Batch Reactor (SBR) en anglès, és un sistema de tractament de fangs actius que opera mitjançant un procediment d'omplerta-buidat. En aquest tipus de reactors, l'aigua residual és addicionada en un sol reactor que treballa per càrregues repetint un cicle (seqüència) al llarg del temps. Una de les característiques dels SBR és que totes les diferents operacions (omplerta, reacció, sedimentació i buidat) es donen en un mateix reactor. La tecnologia SBR no és nova d'ara. El fet, és que va aparèixer abans que els sistema de tractament continu de fangs actius. El precursor dels SBR va ser un sistema d'omplerta-buidat que operava en discontinu. Entre els anys 1914 i 1920, varen sorgir certes dificultats moltes d'elles a nivell d'operació (vàlvules, canvis el cabal d'un reactor a un altre, elevat temps d'atenció per l'operari...) per aquests reactors. Però no va ser fins a finals de la dècada dels '50 principis del '60, amb el desenvolupament de nous equipaments i noves tecnologies, quan va tornar a ressorgir l'interès pels SBRs. Importants millores en el camp del subministrament d'aire (vàlvules motoritzades o d'acció pneumàtica) i en el de control (sondes de nivell, mesuradors de cabal, temporitzadors automàtics, microprocessadors) han permès que avui en dia els SBRs competeixin amb els sistemes convencional de fangs actius. L'objectiu de la present tesi és la identificació de les condicions d'operació adequades per un cicle segons el tipus d'aigua residual a l'entrada, les necessitats del tractament i la qualitat desitjada de la sortida utilitzant la tecnologia SBR. Aquestes tres característiques, l'aigua a tractar, les necessitats del tractament i la qualitat final desitjada determinen en gran mesura el tractament a realitzar. Així doncs, per tal d'adequar el tractament a cada tipus d'aigua residual i les seves necessitats, han estat estudiats diferents estratègies d'alimentació. El seguiment del procés es realitza mitjançant mesures on-line de pH, OD i RedOx, els canvis de les quals donen informació sobre l'estat del procés. Alhora un altre paràmetre que es pot calcular a partir de l'oxigen dissolt és la OUR que és una dada complementària als paràmetres esmentats. S'han avaluat les condicions d'operació per eliminar nitrogen d'una aigua residual sintètica utilitzant una estratègia d'alimentació esglaonada, a través de l'estudi de l'efecte del nombre d'alimentacions, la definició de la llargada i el número de fases per cicle, i la identificació dels punts crítics seguint les sondes de pH, OD i RedOx. S'ha aplicat l'estratègia d'alimentació esglaonada a dues aigües residuals diferents: una procedent d'una indústria tèxtil i l'altra, dels lixiviats d'un abocador. En ambdues aigües residuals es va estudiar l'eficiència del procés a partir de les condicions d'operació i de la velocitat del consum d'oxigen. Mentre que en l'aigua residual tèxtil el principal objectiu era eliminar matèria orgànica, en l'aigua procedent dels lixiviats d'abocador era eliminar matèria orgànica i nitrogen. S'han avaluat les condicions d'operació per eliminar nitrogen i fòsfor d'una aigua residual urbana utilitzant una estratègia d'alimentació esglaonada, a través de la definició del número i la llargada de les fases per cicle, i la identificació dels punts crítics seguint les sondes de pH, OD i RedOx. S'ha analitzat la influència del pH i la font de carboni per tal d'eliminar fòsfor d'una aigua sintètica a partir de l'estudi de l'increment de pH a dos reactors amb diferents fonts de carboni i l'estudi de l'efecte de canviar la font de carboni. Tal i com es pot veure al llarg de la tesi, on s'han tractat diferents aigües residuals per a diferents necessitats, un dels avantatges més importants d'un SBR és la seva flexibilitat.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study measures productive inefficiency within the context of multi-environmental pollution (eco-efficiency) in the Chinese industrial sector. The weighted Russell directional distance model is applied to measure eco-efficiency using production technology. The objective is to clarify how external factors affect eco-efficiency. The major findings are that both foreign direct investment and investment for pollution abatement improve eco-efficiency as measured by air pollutant substances. A levy system for wastewater discharge improves eco-efficiency as measured by wastewater pollutant substances. However, an air pollutant levy does not significantly affect eco-efficiency as measured by air pollutants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

近年来,我国炼油行业发展迅速,炼油能力全世界第二,炼油行业已成为污染大户。本研究针对炼油废水生物处理中存在的稳定达标难、抗冲击负荷能力差、建设投资与运行成本高等问题,就菌剂强化处理炼油废水中试与工程应用展开了研究,以期为菌剂的工程应用与推广提供理论参考与技术支持;并以炼油废水中的主要特征污染物苯酚为研究对象,考察了不同浓度苯酚冲击下功能菌的响应机制,并以此为指导研制功能菌激活促进剂,考察其对功能菌生物学指标的调控效果,以期为废水生物处理有毒污染物冲击调控提供理论依据与技术支持。 中试研究表明,菌剂强化处理炼油废水,出水COD、NH4+-N 平均值为86.7、7.6 mg/L,其平均去除率较常规生物处理系统分别提高了35.47%、59.28%,其耐受COD、NH4+-N 容积负荷分别高达2.42、0.139kg/(m3·d),具有良好的耐冲击能力。工程应用研究表明,菌剂强化处理炼油废水,出水COD、NH4+-N 平均值分别为85.05、8.4mg/L,其去除率较常规生物处理系统提高了25.1%、28.7%,出水水质各项指标均达到了国家《污水综合排放标准GB 8978-1996》一级排放标准。技术经济分析表明,菌剂强化处理炼油废水在建设成本、运行成本上分别降低38%、49%,具有良好的技术经济优势。 苯酚冲击下功能菌响应机制研究表明:不同浓度苯酚冲击下,生物学指标生物量、脱氢酶酶活、1,2-双加氧酶酶活对冲击都有不同程度的响应,其响应敏感程度为脱氢酶酶活>生物量>1,2-双加氧酶酶活。1,2-双加氧酶酶活与COD 降解率相关性良好,可表征苯酚降解过程,确认为调控重点。以此为指导研制出苯酚降解功能菌抗冲击激活促进剂,可有效调控功能菌对有毒污染物苯酚的降解效果,1000mg/L 苯酚冲击下,经调控,其COD 去除率较对照提高20%,降解时间缩短16%以上。其对生物学指标的调控效果为1,2-双加氧酶酶活>生物量>脱氢酶酶活,验证了功能菌在苯酚冲击下的响应机制。研究表明菌剂强化处理炼油废水切实可行,具有良好的技术经济优势。有毒污染物冲击下废水生物处理系统响应机制研究为抗冲击调控提供了新的研究思路。 Currently, China’s oil refining industry is developing rapidly and has become the second largest all over the world. The oil refining industry is one of the major pollution industries in our country. The pilot scale study and engineering application research were conducted aiming at the problems in refining wastewater such as poor treatment stability and water quality, poor anti-shock capacity and expensive running cost, etc., so as to provide theoretical references and technological supports for the engineering application and popularization of microbial preparation in wastewater treatment. Also, the response mechanism of functional microbe under shock of different phenol concentrations, which is the main pollutants in refinery wastewater, was studied. Based on this result, functional microbe activation accelerator was developed, and the regulation effect of functional microbe biological index under phenol shocking were studied, in order to provide theoretical basis and technological support for regulation of toxic shocking of wastewater biological treatment. The result of pilot scale research indicated: for treatment of refinery wastewater in bioaugmention treatment system of microbial preparation, the COD and NH4+-N average value of effluent was 86.7 and 7.6 mg/L, Comparing with normal biological treatment system, the average removal rates of COD, NH4+-N increased 35.47%,59.28% separately by bioaugmention treatment system, which showed better anti-shocking capacity, the volumetric load r of COD and NH4+-N reached 2.42 kg/(m3·d) and 0.139 kg/(m3·d), respectively. The research on engineering application of refinery wastewater bioaugmentation treatment by microbial preparation indicated:the average concentrations of effluent COD and NH4+-N in the bioaugmentation treatment system were 85.05 and 8.4mg/L, which increased by 25.1% and 28.7% comparing with normal biological treatment system of refinery wastewater, And the effluent quality meets the first grade of discharging standard of National Integrated Wastewater Discharge Standard GB 8978-1996. The economic analysis of technology indicated: the demonstration project of bioaugmentation treatment of refinery wastewater by microbial preparation decreased by 38% in construction cost and 49% in running cost. This technology has economic benefits. The response mechanism of functional microbe under phenol shock indicated: biological index such as the biomass concentration, dehydrogenase and 1,2-dioxygenase had different responses under phenol shocking of different concentrations. The response sensitivity of different biological index under phenol shocking of different concentrations is: dehydogenase activity > biomass >1,2-dioxygenase activity, and high correlation of 1,2-dioxygenase and COD degradation percentage is achieved, thus 1,2-dioxygenase could be used to reflect the degradation situation of pollutants. So, 1,2-dioxygenase is the keypoint of regulation. The anti-shock activation accelerator of phenol degradation functional microbe was primarily developed. The results indicated: the activation accelerator could regulate the degradation effect of toxic substance-phenol by functional microbe effectively. For the functional microbe treatment system under phenol shocking of 1000mg/L, the COD degradation rate increased by 20% and the degradation time reduced by more than 16% under regulation of activation accelerator. The regulation effects of biological index are: 1,2-dioxygenase > biomass > dehydrogenase. In this way, the response mechanism of functional microbe under toxic shocking is verified. The result indicated: the augmented microbial preparation treatment of refinery wastewater is applicable. It has many technical and economical advantages. The research results of responses mechanism of wastewater treatment system on toxic pollutants would offer a new idea for regulation of anti-shock.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

制革行业是轻工行业中仅次于造纸业的高耗水、重污染行业,作为劳动密集型行业,在解决大量人口就业问题的同时,也对所在地区环境造成了严重污染。目前我国制革行业每年排放废水8,000~12,000万吨,废水中含铬约3,500 t,SS为1.2×105 t,COD为1.8×105 t,BOD为7×104 t,对水体污染严重。 本研究在对厌氧酸化工艺进行研究、一级好氧处理段进行工艺比选研究的基础上,获得了匀质调节—SBBR—BAF的生物处理工艺,并依托该工艺进行了生物强化处理的研究,考察了菌剂的强化运行效果及其处理水回用的可行性。 研究表明,在进水COD>3,000 mg/L,厌氧酸化具有很好的抗冲击作用,保证了好氧工艺出水COD<200 mg/L;在进水COD<3,000 mg/L,可只通过好氧处理实现出水COD<200 mg/L。厌氧酸化停留时间选择不当,会导致厌氧出水硫化物浓度升高,严重影响好氧系统,会使好氧活性污泥因中毒而解絮。 研究表明,当进水COD为2,000~2,500 mg/L,NH4+-N为130~146 mg/L时,COD、NH4+-N去除率SBBR分别为93.8%~96.6%和14.5%~55.9%,SBR分别为88.8%~94.9%和13%~50.7%,表明SBBR优于SBR。同时,研究发现SBBR污泥增长率为0.05 kgVSS/kgCOD,仅为SBR0.57 kgVSS/kgCOD的8.8%。此外,研究发现SBBR在停止运行后经3个运行周期可回复原油能力,而SBR池经9个周期培养也不能恢复,说明SBBR恢复能力明显优于SBR。 研究表明,以匀质调节—SBBR—BAF为主的制革废水处理工艺,出水水质稳定,进水COD 801~2,834 mg/L、NH4+-N 87~203 mg/L,出水COD<80 mg/L、NH4+-N<10 mg/L,基本达到中水回用标准;操作简单灵活,没有污泥回流系统,污泥产率低,污泥处理费用低;工艺基本不需要添加化学药剂,既节约成本、又避免了二次污染;两级生物膜使得该工艺具有很强的耐冲击负荷能力,特别适合制革废水水质水量波动大的特点。 研究表明,高效菌对系统的启动具有一定的促进作用,强化系统生物膜6天可以成熟,对照系统生物膜9天可以成熟。同时高效菌能加速COD降解,缩短停留时间,强化系统6~8 h可使COD<200 mg/L,对照系统8~10 h可使COD<200 mg/L。长期运行表明,强化系统的SBBR在COD和NH4+-N的去除率都优于对照系统的SBBR。最终出水COD强化系统平均为53 mg/L、对照系统为74 mg/L。在模拟循环过程中,强化系统均有更高的稳定性。可实现8次理论循环,而对照系统只能实现4次理论循环。 研究表明,通过合理的工艺设计,可以实现猪皮制革废水达到《污水综合排放标准GB8976-1996》一级标准,同时满足工厂部分用水要求。通过添加高效微生物,可提高生物处理系统处理能力,使处理水能够满足工厂的多次回用。 As a labour-intensive industry, tanning has created large amount of working opportunities as well as caused severe contamination to environment. And it is one of the highest water-consuming and polluting industry, only second to manufacturing. At present time, Chinese leather industry emits wastewater about 80,000,000~120,000,000 t annually, which contains chromium about 3,500 t, SS 1.2×105 t, COD 1.8×105 t, BOD 7×104 t and ambient riverhead has been polluted greatly. Based on the research of anaerobic acidification and comparison of SBBR and SBR, biotreatment process (Homogenization—SBBR—BAF) had been established to amend the disadvantages of traditional sewage treatment such as too much sludge, high cost of advanced treatment and NH4+-N can not reach the emission standard. Research on the bioaugmentation was also been carried out. Researches showed, when COD of influent was beyond 3,000 mg/L, anaerobic acidification could resist strong impact, thus COD of effluent was less than 200 mg/L; when COD of influent was less than 3,000 mg/L, only throughout aerobic sewage treatment could COD of effluent beless than 200 mg/L. False residence tiome of anaerobic acidification would lead to the higher effluent concentration of sulfide and disintegration of aerobic activated sludge. Researches showed SBBR worked a better than SBR: when influent between 2,000 and 2,500 mg/L, NH4+-N between 130 mg/L and 146 mg/L, COD, NH4+-N removal rate of SBBR was 93.3%~96.6%, 14.5%~55.9% respectively while COD, NH4+-N removal rate of SBR was 88.8%~94.9%, 13%~50.7% respectively. Sludge growth rate of SBBR was 8.8% of that of 0.05 kgVSS/kgCOD. Besides, SBBR could recovered after 3 operating periods while SBR worked no better after 9 operating periods.Therefore, SBBR excelled SBR. Researches showed, effluent quantity of tannery wastewater treatment process (Homogenization—SBBR—BAF) was stable. When COD of influent was between 801 and 2,834 mg/L, NH4+-N was between 87 mg/L and 203 mg/L, COD of effluent was less than 80 mg/L, NH4+-N was less than 10 mg/L, which achieved the standard of reuse. This biotreatment was featured in low cost, easy and flexible management, less sludge, no inverse sludge system. Besides, this technique required no chemical, which could lower the cost and avoid secondary pollution. Great resistant of impact due to two membranes and was suitable for tannery wastewater which was featured by fluctuation of influent quality and quantity. Researches showed effective microorganisms promotes the startup of the process.Biofilm in the bioaugmentation process matured with 6 days while biofilm in normal process matured with 9 days. Effective microorganisms could accelerate the degradation of COD and shorten the residence time. Aggrandizement system could make COD<200 mg/L with 6 to8 hours while cntrolling system could make COD<200 mg/L with 8 to 10 hours. Long-term operating shows that SBBR in the bioaugmentation system worked better than the normal system in the treatment of COD and NH4+-N. The average COC of effluent in bioaugmentation system was 53 mg/L, normal system was 74 mg/L. In the simulative circulation process,aggrandizement process, which could fulfill 8 times theoretical circulation, works more stably than controlling process which could only fulfill 4 times theoretical circulation. Researches showed that reasonable design could make the wastewater meet the first grade of discharging standard of National Integrated Wastewater Discharge Standard (GB8976-1996), and partially meet the demand of water using of the factory. Adding effective microorganisms could enhance the biotreatment and make the effluents reuse many times.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

近年来各种环境污染事故频发,据统计仅2001~2003年间,发生的各类环境污染事故就高达5606次,其中水污染事故3235次,占全部的57.7%。这些事故不仅给人民生命财产造成巨大损失,也给生态环境造成严重的破坏。因此开发安全高效的应急处理技术迫在眉睫。本研究以筛选高效苯胺降解菌为基础,通过对高效菌降解性能的研究指导将高效菌作为功能郡主投加到已有生物处理系统强化应急处理苯胺突发污染事故废液,取得了良好的效果。 苯胺高效降解菌AN-P1为红球菌(Rhodococcus sp.),其通过间位途径降解苯胺,AN-P1利用苯胺生长和降解的最佳pH为6,最适浓度为2000 mg/L,最适温度为30 ℃,最佳接种量为0.3‰。AN-P1降解含500 mg/L、1000 mg/L、2000 mg/L苯胺的培养物分别经过28 h、24 h、32 h降解,出水苯胺含量能达到《污水综合排放标准》(GB8978-1996)一级标准。但由于苯胺降解过程中释放了大量氨氮,出水氨氮仍较高未能达标排放。而常规SBR系统应急处理效果较差,苯胺和COD去除率均低于10%,出水未能达标排放。活性碳吸附后的回收和后续处理也会带来操作不变和二次污染问题,且处理后出水往往难于达标排放,尚需进行进一步处理。 生物处理系统应急处理后恢复运行处理效果监测和PCR-DGGE图谱分析显示,用AN-P1菌强化应急处理系统后不仅能快速高效的去除苯胺,而且可以有效保障处理系统对污染物的净化性能,有效的保护系统中的功能微生物免受苯胺毒害。 研究结果表明,从实际处理效果、对原有生物系统性能保护及实际应用操作等多方面考虑,用AN-P1菌强化应急处理苯胺突发污染事故在技术上都是可行的。本研究为应急处理苯胺突然污染事故废液提供了新的方法。 Recent years, environment pollution accidents happened frequently, the data showed that there are 5606 accidents between 2001 and 2003, including 3235 water environment accidents, which is 57.7% of all. These accedents not only caused money lost and life lost but also caused serious damage to the ecologicl environment. So exploring highly-effective and secure methods to solve these accidents is an urgent mission. We screened a highly-effective aniline-degrading bacterium and did some researches on its ability to degrade aniline, in order to guide the emergency treatment of aniline containing wastewater that caused by sudden accident pollution with bioaugmentation. A highly-effective aniline-degrading bacterium AN-P1 was isolate and characterized as Rhodococcus sp. It degrades aniline through meta-cleavage pathway. The optimal pH and temperature for cell growth and aniline degradation were 6 and 30 ℃, respectively, and the opitimal concentration of aniline was 2000 mg/L, the optimal inoculation amount was 0.3‰.It took bacterium AN-P1 only 18 h, 24 h and 32 h, respectively, for the treatment of MSB containing 500 mg/L, 1000 mg/L, 2000 mg/L aniline to meet the first grade of national some of the NH4+-N which caused by aniline degradation. It took bacterium AN-P1 only 10 h, 20 h and 32 h, respectively, for the treatment of wastewater containing 500 mg/L, 1000 mg/L, 2000 mg/L aniline to meet the first grade of national integrated wastewater discharge standard. The bacterium AN-P1 can also remove some of the NH4+-N which caused by aniline degradation. It took bacterium AN-P1 only 10 h, 20 h and 32 h, respectively, for the treatment of wastewater containing 500 mg/L, 1000 mg/L, 2000 mg/L aniline to meet the first grade of national integrated wastewater discharge standard. By combing AN-P1 with regular SBR system, it took only 36 h for the emergency treatment of wastewater containing 2000 mg/L aniline under simulating engineering conditions to meet the discharge standard. While the NH4+-N of effluent can not meet the standard because of the high amount NH4+-N caused by aniline degradation. The regular SBR system was not good at aniline and COD removal. The removal efficiency of which are less than 10%. It cost 67.8 g activated carbon to absorbed 1000 mg aniline. It is inconvenient to transport and use it for the emergency treatment of aniline when the sudden pollution accident happened. Meanwhile, it was complex ad hard to recycle the activated carbon and treat the aniline wastewater get from activated carbon recycling too. Hard to meet the effluent standard was also a problem of activated carbon absorption method. According to the PCR-DGGE profile and removal efficiency of pollutants and COD when the systerm recover from emergency treatment, AN-P1 can efficiently protect the microbial community of regular activated sludge system against the aniline. It proved that combing AN-P1 with regular biological system is a feasible strategy for emergency treatment of aniline sudden pollution accident. The research offered a new way for emergency treatment of aniline sudden pollution accident.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil, na Área de Especialização de Hidráulica

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The wastewater discharge produces impacts on receiving water bodies. Nutrients as P produce implications on lentic systems because they accelerate the eutrophication processes. Several technologies for P removal from the wastewater have been used: physic chemical treatment systems with important effects by coagulant products addition; biological processes based on anaerobic and aerobic conditions with great implications on the required volume; natural systems as stabilization ponds and irrigation require bigger areas and post-treatment processes. The aerobic fluidized bed reactors with internal circulation (AFBRIC) are compact options with high concentrations of active biomass that have demonstrated their capacity for organic matter and N removal. For sewage from the wastewater pumping station of Ilha Solteira city and effluents of a recirculation aquaculture system (RAS) for semi-intensive tilapia farming, the reactive P and total P removal efficiency in three AFBRIC with 250 mm external tube diameter and different internal tube diameter (ITD), for two different support media at different concentrations was evaluated. The average reactive P removal efficiency for domestic wastewater to hydraulic retention time (HRT) of 3 hours and 125 mm ITD reactor varied from 25,6 to 38,4% and with 150 mm ITD reactor varied from 27,5 to 32,5%; the average total P removal for the RAS wastewater at a HRT of 0,19 hours and 100 mm ITD was of 32,7%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)