953 resultados para volume-time curve


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Despite numerous studies on endotracheal tube cuff pressure (CP) management, the literature has yet to establish a technique capable of adequately tilling the cuff with an appropriate volume of air while generating low CP in a less subjective way. the purpose of this prospective study was to evaluate and compare the CP levels and air volume required to fill the endotracheal tubes cuff using 2 different techniques (volume-time curve versus minimal occlusive volume) in the immediate postoperative period after coronary artery bypass grafting. METHODS: A total of 267 subjects were analyzed. After the surgery, the lungs were ventilated using pressure controlled continuous mandatory ventilation, and the same ventilatory parameters were adjusted. Upon arrival in the ICU, the cuff was completely deflated and re-inflated, and at this point the volume of air to fill the cuff was adjusted using one of 2 randomly selected techniques: volume-time curve and minimal occlusive volume. We measured the volume of air injected into the cuff, the CP, and the expired tidal volume of the mechanical ventilation after the application of each technique. RESULTS: the volume-time curve technique demonstrated a significantly lower CP and a lower volume of air injected into the cuff, compared to the minimal occlusive volume technique (P < .001). No significant difference was observed in the expired tidal volume between the 2 techniques (P = .052). However, when the subjects were submitted to the minimal occlusive volume technique, 17% (n = 47) experienced air leakage as observed by the volume-time graph. CONCLUSIONS: the volume-time curve technique was associated with a lower CP and a lower volume of air injected into the cuff, when compared to the minimal occlusive volume technique in the immediate postoperative period after coronary artery bypass grafting. Therefore, the volume-time curve may be a more reliable alternative for endotracheal tube cuff management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Previous investigation showed that the volume-time curve technique could be an alternative for endotracheal tube (ETT) cuff management. However, the clinical impact of the volume-time curve application has not been documented. the purpose of this study was to compare the occurrence and intensity of a sore throat, cough, thoracic pain, and pulmonary function between these 2 techniques for ETT cuff management: volume-time curve technique versus minimal occlusive volume (MOV) technique after coronary artery bypass grafting. METHODS: A total of 450 subjects were randomized into 2 groups for cuff management after intubation: MOV group (n = 222) and volume-time curve group (n = 228). We measured cuff pressure before extubation. We performed spirometry 24 h before and after surgery. We graded sore throat and cough according to a 4-point scale at 1, 24, 72, and 120 h after extubation and assessed thoracic pain at 24 h after extubation and quantified the level of pain by a 10-point scale. RESULTS: the volume-time curve group presented significantly lower cuff pressure (30.9 +/- 2.8 vs 37.7 +/- 3.4 cm H2O), less incidence and intensity of sore throat (1 h, 23.7 vs 51.4%; and 24 h, 18.9 vs 40.5%, P < .001), cough (1 h, 19.3 vs 48.6%; and 24 h, 18.4 vs 42.3%, P < .001), thoracic pain (5.2 +/- 1.8 vs 7.1 +/- 1.7), better preservation of FVC (49.5 +/- 9.9 vs 41.8 +/- 12.9%, P = .005), and FEV1, (46.6 +/- 1.8 vs 38.6 +/- 1.4%, P = .005) compared with the MOV group. CONCLUSIONS: the subjects who received the volume-time curve technique for ETT cuff management presented a significantly lower incidence and severity of sore throat and cough, less thoracic pain, and minimally impaired pulmonary function than those subjects who received the MOV technique during the first 24 h after coronary artery bypass grafting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lung ultrasound use is increasing in respiratory medicine thanks to its development in the latest years. Actually it allows to study diseases of the chest wall (traumas, infections, neoplasms), diaphragm (paralysis, ipokinesis), pleura (effusions, pneumothorax, thickenings, neoplasms) and lung parenchyma (consolidations, interstitial syndromes, peripheral lesions). One of the most useful application of chest ultrasound is the evaluation of effusions. However, no standardized approach for ultrasound-guided thoracenthesis is available. Our study showed that our usual ultrasonographic landmark (“V-point”) could be a standard site to perform thoracenthesis: in 45 thoracenthesis no pneumothorax occurred, drainage was always successful at first attempt. Values of maximum thickness at V-point and drained fluid volume showed a significative correlation. Proteins concentration of ultrasound patterns of effusions (anechoic, ipoechoic, moving echoic spots, dense moving spots, hyperechoic) were compared to those of the macroscopic features of fluids showing connection between light-yellow fluid and echoic moving spots pattern and between ipoechoic/dense moving spots and cloudy-yellow/serum-haematic fluids. These observations suggest that ultrasound could predict chemical-physical features of effusions. Lung ultrasound provides useful information about many disease of the lung, but actually there is not useful in obstructive bronchial diseases. Analysing diaphragmatic kinetics using M-mode through transhepatic scan we described a similarity between diaphragm excursion during an expiratory forced maneuver and the volume/time curve of spirometry. This allowed us to identify the M-mode Index of Obstruction (MIO), an ultrasound-analogue of FEV1/VC. We observed MIO values of normal subjects (9) and obstructed patients (9) comparing the two groups. FEV1/VC and MIO showed a significant correlation suggesting that MIO may be affected by airways obstruction; MIO values were significatively different between normal and obstructed so that it could identify an obstructive syndrome. The data show that it is possible to suspect the presence of obstructive syndrome of the airways using ultrasonography of the diaphragm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com o objetivo de se avaliar a importância do \"clearance\" do dietilenotriamino-pentacetato marcado com Tecnécio 99m (DTPA-Tecnécio-99m) em portadores de pneumopatia por amiodarona foram estudados 40 indivíduos, em quatro grupos. Grupo I: 10 voluntários normais, assintomáticos e não fumantes (8 homens e 2 mulheres), com média de idade de 56,80 anos. Grupo II: 10 voluntários normais, assintomáticos e fumantes (6 homens e 4 mulheres ), com média de idade de 27,50 anos. Grupo III: 10 pacientes não fumantes ( 4 homens e 5 mulheres ), com média de idade de 52,90 anos. Todos faziam uso crônico de amiodarona por via oral. Grupo IV: 10 pacientes portadores de pneumopatia por amiodarona, quatro ex-fumantes, dois fumantes e quatro não fumantes ( 8 homens e 2 mulheres) com média de idade de 52,90 anos. Todos faziam uso de amiodarona por via oral e nenhum fumou nas 4 semanas que precederam o estudo. Após espirometria que constou do registro da curva volume-tempo, todos inalaram 4 ml de solução salina contendo 740 MBq de DTPA Tecnécio-99m, durante cinco minutos. Através de uma c~mara de cintilação computadorizada foram obtidas imagens pulmonares, definindo-se 9 áreas de interesse. Para cada região escolhida foi determinada uma curva de \"clearance\" extraindo-se o valor de meia-vida biológica em minu- tos ( T 1/2 ) e a taxa percentual de \" clearance\" alvéolo capilar do radioaerossol por minuto (K%/min). Observamos que, das variáveis espirométricas consideradas, a capacidade vital forçada (CVF) e o volume expiratório forçado no 1 segundo (VEF1) mostraram diferenças significantes entre os grupos I e IV. A contagem total de radioatividade de ambos os pulmões não mostrou relação com a CVF e o VEF1. O \" clearance \" pulmonar do DTPA Tecnécio-99m foi maior nos grupos 11 e IV, porém não permitindo sua diferenciação. Estes resultados permitem concluir: Os pacientes portadores de pneumonite por amiodaro- na apresentam\" clearance \" alvéolo-capilar de DTPA Tecnécio-99m significativamente maior que os indivíduos do grupo de normais não fumantes. Este fato também se verificou em relação aos pacientes em uso crônico de amiodarona mas sem evidências de pneumopatia. Não é possível diferenciar os fumantes dos portadores de pneumonite por amiodarona através da análise da integridade da barreira alvéolo-epitelial com DTPA Tecnécio-99m. Comparativamente, o estudo da integridade alvéolo-epitelial pelo \"clearance\" pulmonar de DTPA Tecnécio-99m é mais sensível que a espirometria na avaliação da pneumonite por amiodarona, permitindo diferenciar estes pacientes dos que fazem uso crônico da droga

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This research work analyses techniques for implementing a cell-centred finite-volume time-domain (ccFV-TD) computational methodology for the purpose of studying microwave heating. Various state-of-the-art spatial and temporal discretisation methods employed to solve Maxwell's equations on multidimensional structured grid networks are investigated, and the dispersive and dissipative errors inherent in those techniques examined. Both staggered and unstaggered grid approaches are considered. Upwind schemes using a Riemann solver and intensity vector splitting are studied and evaluated. Staggered and unstaggered Leapfrog and Runge-Kutta time integration methods are analysed in terms of phase and amplitude error to identify which method is the most accurate and efficient for simulating microwave heating processes. The implementation and migration of typical electromagnetic boundary conditions. from staggered in space to cell-centred approaches also is deliberated. In particular, an existing perfectly matched layer absorbing boundary methodology is adapted to formulate a new cell-centred boundary implementation for the ccFV-TD solvers. Finally for microwave heating purposes, a comparison of analytical and numerical results for standard case studies in rectangular waveguides allows the accuracy of the developed methods to be assessed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Crystallization kinetics of MSI and MSII stages in Metglas 2826A has been investigated by quantitative transmission electron microscopy. The volume fraction of crystallization against time curve has been found to show a plateau in the lower temperature region of annealing. It has been found that the glass transition temperature, T g, has no effect on the sequence reversal of the crystallization reaction. It has been shown that the sequence reversal of transformation stages occurs due to the large difference in the activation energy of crystallization of MSI and MSII. In addition, the change in the morphology of the crystals obtained by annealing the amorphous alloy below and above the glass transition temperature, T g, is reported.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Tese de Doutoramento apresentada à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Doutror em Ciências da Terra.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A 2D isothermal finite element simulation of the injection stretch-blow molding (ISBM) process for polyethylene terephthalate (PET) containers has been developed through the commercial finite element package ABAQUS/standard. In this work, the blowing air to inflate the PET preform was modeled through two different approaches: a direct pressure input (as measured in the blowing machine) and a constant mass flow rate input (based on a pressure-volume-time relationship). The results from these two approaches were validated against free blow and free stretch-blow experiments, which were instrumented and monitored through high-speed video. Results show that simulation using a constant mass flow rate approach gave a better prediction of volume vs. time curve and preform shape evolution when compared with the direct pressure approach and hence is more appropriate in modeling the preblowing stage in the injection stretch-blow molding process

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La préparation de formulations à libération contrôlée est le domaine des sciences pharmaceutiques qui vise à modifier l’environnement immédiat des principes actifs pour en améliorer l’efficacité et l’innocuité. Cet objectif peut être atteint en modifiant la cinétique de circulation dans le sang ou la distribution dans l’organisme. Le but de ce projet de recherche était d’étudier le profil pharmacocinétique (PK) de différentes formulations liposomales. L’analyse PK, généralement employée pour représenter et prédire les concentrations plasmatiques des médicaments et de leurs métabolites, a été utilisée ici pour caractériser in vivo des formulations sensibles au pH servant à modifier la distribution intracellulaire de principes actifs ainsi que des liposomes destinés au traitement des intoxications médicamenteuses. Dans un premier temps, la PK d’un copolymère sensible au pH, à base de N-isopropylacrylamide (NIPAM) et d’acide méthacrylique (MAA) a été étudiée. Ce dernier, le p(NIPAM-co-MAA) est utilisé dans notre laboratoire pour la fabrication de liposomes sensibles au pH. L’étude de PK conduite sur les profils de concentrations sanguines de différents polymères a défini les caractéristiques influençant la circulation des macromolécules dans l’organisme. La taille des molécules, leur point de trouble ainsi que la présence d’un segment hydrophobe à l’extrémité des chaînes se sont avérés déterminants. Le seuil de filtration glomérulaire du polymère a été évalué à 32 000 g/mol. Finalement, l’analyse PK a permis de s’assurer que les complexes formés par la fixation du polymère à la surface des liposomes restaient stables dans le sang, après injection par voie intraveineuse. Ces données ont établi qu’il était possible de synthétiser un polymère pouvant être adéquatement éliminé par filtration rénale et que les liposomes sensibles au pH préparés avec celui-ci demeuraient intacts dans l’organisme. En second lieu, l’analyse PK a été utilisée dans le développement de liposomes possédant un gradient de pH transmembranaire pour le traitement des intoxications médicamenteuses. Une formulation a été développée et optimisée in vitro pour capturer un médicament modèle, le diltiazem (DTZ). La formulation liposomale s’est avérée 40 fois plus performante que les émulsions lipidiques utilisées en clinique. L’analyse PK des liposomes a permis de confirmer la stabilité de la formulation in vivo et d’analyser l’influence des liposomes sur la circulation plasmatique du DTZ et de son principal métabolite, le desacétyldiltiazem (DAD). Il a été démontré que les liposomes étaient capables de capturer et de séquestrer le principe actif dans la circulation sanguine lorsque celui-ci était administré, par la voie intraveineuse. L’injection des liposomes 2 minutes avant l’administration du DTZ augmentait significativement l’aire sous la courbe du DTZ et du DAD tout en diminuant leur clairance plasmatique et leur volume de distribution. L’effet de ces modifications PK sur l’activité pharmacologique du médicament a ensuite été évalué. Les liposomes ont diminué l’effet hypotenseur du principe actif administré en bolus ou en perfusion sur une période d’une heure. Au cours de ces travaux, l’analyse PK a servi à établir la preuve de concept que des liposomes possédant un gradient de pH transmembranaire pouvaient modifier la PK d’un médicament cardiovasculaire et en diminuer l’activité pharmacologique. Ces résultats serviront de base pour le développement de la formulation destinée au traitement des intoxications médicamenteuses. Ce travail souligne la pertinence d’utiliser l’analyse PK dans la mise au point de vecteurs pharmaceutiques destinés à des applications variées. À ce stade de développement, l’aspect prédictif de l’analyse n’a pas été exploité, mais le côté descriptif a permis de comparer adéquatement diverses formulations et de tirer des conclusions pertinentes quant à leur devenir dans l’organisme.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE--To analyze the influence of the myocardial engorgement due to coronary perfusion on the left ventricular diastolic pressure/volume (P/V) relations. METHODS--The study was undertaken in the isovolumic blood-perfused dog heart preparation (n = 7). The P/V relations were determined promoting ventricular volumes variations by steps of 2ml, in two conditions: during coronary perfusion pressure of 100mmHg and after occlusion of the perfusion line. RESULTS--It was verified that the P/V relations obtained without myocardial perfusion shifted to the down right in respect to the perfused heart. A exponential fitting of the P/V relations allows to conclude that there was no difference among the slopes of the curves obtained with and without perfusion. CONCLUSION--Our results indicated that coronary perfusion restrain the capacity of the left ventricle to receive blood, but there is no influence on the passive elastic stiffness of the chamber. This effect was taught to be consequence of the myocardial erectile property.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gastrotoxicity is a major problem for long-term therapy with non-steroidal anti-inflammatory drugs (NSAIDs). DICCIC (1-(2,6-dichlorophenyl)indolin-2-one) is a new diclofenac prodrug, which has proven anti-inflammatory activity without gastroulcerogenic effect. The aim of this work was to compare the pharmacokinetic profiles of diclofenac from DICCIC (7.6 mg/kg equivalent to 8.1 mg/kg diclofenac) and diclofenac (8.1 mg/kg) administration in Wistar rats weighing 250-300 g (n=20). The doses were calculated by interspecific allometric scaling based on the 2 mg/kg from diary human dose of diclofenac. Blood samples were collected in heparinized tubes via the femoral artery through the implanted catheter. The plasma was separated and quantitation was made in a HPLC system with a UV-Vis detector. The confidence limits of the bioanalytical method were appropriate for its application in a preclinical pharmacokinetic study. The AUC of diclofenac from DICCIC (53.7± 5.8 ug/mL.min) was significantly less (Mann Whitney test, p<0.05) than that of diclofenac from diclofenac administration (885.9 ± 124,8 ug/mL.min). Terminal half-life of diclofenac from DICCIC (50.1 ± 17.2 min) was significantly less (Mann Whitney test, p<0.05) than that of diclofenac from diclofenac administration (247.4 ± 100.9 min). Still the parameters clearance and distribution volume were calculated for diclofenac from diclofenac, whose results were 9.2 ±1.2 mL/min.kg and 3.3 ±1.2 L/kg, respectively. The results of DICCIC from DICCIC administration were 108.9 ± 19.6 mL/min.kg and 7.8 ± 2.4 L/kg for clearance and distribution volume, respectively. The pharmacokinetic profile demonstrated that there was an increase in diclofenac elimination and a lower exposure to diclofenac with administration of DICCIC compared to diclofenac. © 2013 Bentham Science Publishers.