964 resultados para visual field defect
Resumo:
BACKGROUND: Visual acuity serves as only a rough gauge of macular function. The aim therefore was to ascertain whether central an assessment of the central visual field afforded a closer insight into visual function after removal of epiretinal membranes and Infracyanine-Green- or Trypan-Blue-assisted peeling of the inner limiting membrane. Patients and methods: Fourty-three patients undergoing pars-plana vitrectomy for the removal of epimacular membranes and dye-assisted peeling of the inner limiting membrane using either Infracyanine Green (n = 29; group 1) or Trypan Blue (n = 14; group 2) were monitored prospectively for 12 months. Preoperatively, and 1, 6 and 12 months postoperatively, distance and reading visual acuities were evaluated; the central visual field was assessed by automated static perimetry. RESULTS: Twelve months after surgery, distance and reading visual acuities had improved in both groups, but to a significant degree only in Trypan-Blue-treated eyes. The difference between the two groups was not significant. Likewise at this juncture, the mean size of the visual-field defect remained unchanged in Trypan-Blue-treated eyes (preoperative: 4.3 (SD 2.1) dB; 12 months: 4.0 (2.1) dB (p = 0.15)), but had increased in Infracyanine-Green-treated ones (from 5.3 (3.7) dB to 8.0 (5.2) dB (p = 0.027)). CONCLUSION: Unlike visual acuity, the central visual field had deteriorated in Infracyanine-Green-treated eyes but not in Trypan-Blue-treated eyes 12 months after surgery. Hence, as a predictor of functional outcome, testing of the central visual field may be a more sensitive gauge than visual acuity. Furthermore, Infracyanine Green may have a chronic and potentially clinically relevant effect on the macula which is not reflected in the visual acuity.
Resumo:
Pure alexia is an acquired reading disorder characterized by a disproportionate prolongation of reading time as a function of word length. Although the vast majority of cases reported in the literature show a right-sided visual defect, little is known about the contribution of this low-level visual impairment to their reading difficulties. The present study was aimed at investigating this issue by comparing eye movement patterns during text reading in six patients with pure alexia with those of six patients with hemianopic dyslexia showing similar right-sided visual field defects. We found that the role of the field defect in the reading difficulties of pure alexics was highly deficit-specific. While the amplitude of rightward saccades during text reading seems largely determined by the restricted visual field, other visuo-motor impairments-particularly the pronounced increases in fixation frequency and viewing time as a function of word length-may have little to do with their visual field defect. In addition, subtracting the lesions of the hemianopic dyslexics from those found in pure alexics revealed the largest group differences in posterior parts of the left fusiform gyrus, occipito-temporal sulcus and inferior temporal gyrus. These regions included the coordinate assigned to the centre of the visual word form area in healthy adults, which provides further evidence for a relation between pure alexia and a damaged visual word form area. Finally, we propose a list of three criteria that may improve the differential diagnosis of pure alexia and allow appropriate therapy recommendations.
Resumo:
Presentation Purpose:To relate structural change to functional change in age-related macular degeneration (AMD) in a cross-sectional population using fundus imaging and the visual field status. Methods:10 degree standard and SWAP visual fields and other standard functional clinical measures were acquired in 44 eyes of 27 patients at various stages of AMD, as well as fundus photographs. Retro-mode SLO images were captured in a subset of 29 eyes of 19 of the patients. Drusen area, measured by automated drusen segmentation software (Smith et al. 2005) was correlated with visual field data. Visual field defect position was compared to the position of the imaged drusen and deposits using custom software. Results:The effect of AMD stage on drusen area within the 6000µm was significant (One-way ANOVA: F = 17.231, p < 0.001), however the trend was not strong across all stages. There were significant linear relationships between visual field parameters and drusen area. The mean deviation (MD) declined by 3.00dB and 3.92dB for each log % drusen area for standard perimetry and SWAP, respectively. The visual field parameters of focal loss displayed the strongest correlations with drusen area. The number of pattern deviation (PD) defects increased by 9.30 and 9.68 defects per log % drusen area for standard perimetry and SWAP, respectively. Weaker correlations were found between drusen area and visual acuity, contrast sensitivity, colour vision and reading speed. 72.6% of standard PD defects and 65.2% of SWAP PD defects coincided with retinal signs of AMD on fundus photography. 67.5% of standard PD defects and 69.7% of SWAP PD defects coincided with deposits on retro-mode images. Conclusions:Perimetry exhibited a stronger relationship with drusen area than other measures of visual function. The structure-function relationship between visual field parameters and drusen area was linear. Overall the indices of focal loss had a stronger correlation with drusen area in SWAP than in standard perimetry. Visual field defects had a high coincidence proportion with retinal manifestations of AMD.Smith R.T. et al. (2005) Arch Ophthalmol 123:200-206.
Resumo:
Purpose: The aims of this study were to develop an algorithm to accurately quantify Vigabatrin (VGB)-induced central visual field loss and to investigate the relationship between visual field loss and maximum daily dose, cumulative dose and duration of dose. Methods: The sample comprised 31 patients (mean age 37.9 years; SD 14.4 years) diagnosed with epilepsy and exposed to VGB. Each participant underwent standard automated static visual field examination of the central visual field. Central visual field loss was determined using continuous scales quantifying severity in terms of area and depth of defect and additionally by symmetry of defect between the two eyes. A simultaneous multiple regression model was used to explore the relationship between these visual field parameters and the drug predictor variables. Results: The regression model indicated that maximum VGB dose was the only factor to be significantly correlated with individual eye severity (right eye: p = 0.020; left eye: p = 0.012) and symmetry of visual field defect (p = 0.024). Conclusions: Maximum daily dose was the single most reliable indicator of those patients likely to exhibit visual field defects due to VGB. These findings suggest that high maximum dose is more likely to result in visual field defects than high cumulative doses or those of long duration.
Resumo:
Purpose The aim of this study was to test the correlation between Fourier-domain (FD) optical coherence tomography (OCT) macular and retinal nerve fibre layer (RNFL) thickness and visual field (VF) loss on standard automated perimetry (SAP) in chiasmal compression. Methods A total of 35 eyes with permanent temporal VF defects and 35 controls underwent SAP and FD-OCT (3D OCT-1000; Topcon Corp.) examinations. Macular thickness measurements were averaged for the central area and for each quadrant and half of that area, whereas RNFL thickness was determined for six sectors around the optic disc. VF loss was estimated in six sectors of the VF and in the central 16 test points in the VF. The correlation between VF loss and OCT measurements was tested with Spearman`s correlation coefficients and with linear regression analysis. Results Macular and RNFL thickness parameters correlated strongly with SAP VF loss. Correlations were generally stronger between VF loss and quadrantic or hemianopic macular thickness than with sectoral RNFL thickness. For the macular parameters, we observed the strongest correlation between macular thickness in the inferonasal quadrant and VF loss in the superior temporal central quadrant (rho=0.78; P<0.001) whereas for the RNFL parameters the strongest correlation was observed between the superonasal optic disc sector and the central temporal VF defect (rho=0.60; P<0.001).
Resumo:
Based on neurophysiological findings and a grid to score binocular visual field function, two hypotheses concerning the spatial distribution of fixations during visual search were tested and confirmed in healthy participants and patients with homonymous visual field defects. Both groups showed significant biases of fixations and viewing time towards the centre of the screen and the upper screen half. Patients displayed a third bias towards the side of their field defect, which represents oculomotor compensation. Moreover, significant correlations between the extent of these three biases and search performance were found. Our findings suggest a new, more dynamic view of how functional specialisation of the visual field influences behaviour.
Resumo:
Background - An evaluation of standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP) for the central 10–2 visual field test procedure in patients with age-related macular degeneration (AMD) is presented in order to determine methods of quantifying the central sensitivity loss in patients at various stages of AMD. Methods - 10–2 SAP and SWAP Humphrey visual fields and stereoscopic fundus photographs were collected in 27 eyes of 27 patients with AMD and 22 eyes of 22 normal subjects. Results - Mean Deviation and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post hoc analysis revealed overlap of functional values among stages. In SWAP, indices of focal loss were more sensitive to detecting differences in AMD from normal. SWAP defects were greater in depth and area than those in SAP. Central sensitivity (within 1°) changed by -3.9 and -4.9 dB per stage in SAP and SWAP, respectively. Based on defect maps, an AMD Severity Index was derived. Conclusions - Global indices of focal loss were more sensitive to detecting early stage AMD from normal. The SWAP sensitivity decline with advancing stage of AMD was greater than in SAP. A new AMD Severity Index quantifies visual field defects on a continuous scale. Although not all patients are suitable for SWAP examinations, it is of value as a tool in research studies of visual loss in AMD.
Resumo:
Presentation Purpose:To determine methods of quantifying the sensitivity loss in the central 10o visual field in a cross section of patients at various stages of age-related macular degeneration (AMD). Methods:Standard and short-wavelength automated perimetry (SAP and SWAP) visual fields were collected using program 10-2 of the Humphrey Field Analyzer, in 44 eyes of 27 patients with AMD and 41 eyes of 22 normal subjects. Stereoscopic fundus photographs were graded by two independent observers and the stage of disease determined. Global indices were compared for their ability to delineate the normal visual field from early stages of AMD and to differentiate between stages. Results:Mean Deviation (MD) and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post-hoc analysis revealed overlap of functional values between stages. Global indices of focal loss, PSD and local spatial variability (LSV) were the most sensitive to detecting differences between normal subjects and early stage AMD patients, in SAP and SWAP, respectively. Overall, defects were confined to the central 5°. SWAP defects were consistently greater in depth and area than those in SAP. The most vulnerable region of the 10° field to sensitivity loss with increasing stage of AMD was the central 1°, in which the sensitivity decline was -4.8dB per stage in SAP and -4.9dB per stage in SWAP. Based on the pattern deviation defect maps, a severity index of AMD visual field loss was derived. Threshold variability was considerably increased in late stage AMD eyes. Conclusions:Global indices of focal loss were more sensitive to the detection of early stage AMD from normal. The sensitivity decline with advancing stage of AMD was greater in SWAP compared to SAP, however the trend was not strong across all stages of disease. The less commonly used index LSV represents relatively statistically unmanipulated summary measure of focal loss. A new severity index is described which is sensitive to visual field change in AMD, measures visual field defects on a continuous scale and may serve as a useful measure of functional change in AMD in longitudinal studies. Keywords: visual fields • age-related macular degeneration • perimetry
Resumo:
Presentation Purpose:To examine the correlation of central visual field loss and progression of structural changes in the macular area in age-related macular degeneration (AMD). Methods:Central 10° standard and short-wavelength automated perimetry (SWAP) visual fields were acquired in 39 eyes of 24 patients with AMD using a Humphrey Field Analyzer. Stereoscopic fundus photographs were graded1 by two independent observers and the stage of disease determined2. Custom software mapped perimetric data onto fundus images in order to relate structural changes to functional loss. Results:Mean deviation (MD) in standard perimetry changed from 0.04 dB at stage 1 to -12.39 dB at stage 4 (r2=0.48, p<0.001). The group mean SWAP MD was -5.26 dB at stage 1 and increased to -17.08 dB at stage 4 (r2=0.53, p<0.001). Pattern standard deviation (PSD) also increased with advancing stage in standard perimetry; 1.32 dB to 8.67 dB at stage 1 and 4, respectively (r2=0.54, p<0.001). In SWAP, PSD increased from 2.86 dB to 5.63 dB at stage 1 and stage 4 (r2=0.43, p<0.001). Defect frequency was greater in SWAP than standard perimetry. Early stage defects occurred with the greatest frequency at eccentricities of 3.2° and 5.1° in standard perimetry and at 4.2° in SWAP. Late stage defects were most frequent at 1° eccentricity in standard perimetry and at 1° and 9° in SWAP. MD declined with increasing affected retinal area over the central 3000µm; by 0.20 dB (r2=0.67, p<0.001) and 0.18 dB (r2=0.49, p<0.001) per % increase in defect area for standard perimetry and SWAP respectively. 41% of defects were associated with structural changes on the retina in standard perimetry and 43% in SWAP. Conclusions:Sensitivity decreased with advancing stage of AMD, with a greater effect demonstrated in SWAP compared to standard perimetry. The central field became less uniform as stage increased. SWAP defects occurred at similar locations but were deeper and wider than corresponding defects in standard perimetry. Central loss in SWAP is a sensitive marker of functional progression in AMD.1. Bird et al. (1995) Surv Ophthalmol 39:367-3742. van Leeuwen et al. (2003) Arch Ophthalmol 121:519-526
Resumo:
Background: Vigabatrin (VGB) is an anti-epileptic medication which has been linked to peripheral constriction of the visual field. Documenting the natural history associated with continued VGB exposure is important when making decisions about the risk and benefits associated with the treatment. Due to its speed the Swedish Interactive Threshold Algorithm (SITA) has become the algorithm of choice when carrying out Full Threshold automated static perimetry. SITA uses prior distributions of normal and glaucomatous visual field behaviour to estimate threshold sensitivity. As the abnormal model is based on glaucomatous behaviour this algorithm has not been validated for VGB recipients. We aim to assess the clinical utility of the SITA algorithm for accurately mapping VGB attributed field loss. Methods: The sample comprised one randomly selected eye of 16 patients diagnosed with epilepsy, exposed to VGB therapy. A clinical diagnosis of VGB attributed visual field loss was documented in 44% of the group. The mean age was 39.3 years∈±∈14.5 years and the mean deviation was -4.76 dB ±4.34 dB. Each patient was examined with the Full Threshold, SITA Standard and SITA Fast algorithm. Results: SITA Standard was on average approximately twice as fast (7.6 minutes) and SITA Fast approximately 3 times as fast (4.7 minutes) as examinations completed using the Full Threshold algorithm (15.8 minutes). In the clinical environment, the visual field outcome with both SITA algorithms was equivalent to visual field examination using the Full Threshold algorithm in terms of visual inspection of the grey scale plots, defect area and defect severity. Conclusions: Our research shows that both SITA algorithms are able to accurately map visual field loss attributed to VGB. As patients diagnosed with epilepsy are often vulnerable to fatigue, the time saving offered by SITA Fast means that this algorithm has a significant advantage for use with VGB recipients.
Resumo:
Objective: To determine intraocular pressure (IOP)-dependent and IOP-independent variables associated with visual field (VF) progression in treated glaucoma. Design: Retrospective cohort of the Glaucoma Progression Study. Methods: Consecutive, treated glaucoma patients with repeatable VF loss who had 8 or more VF examinations of either eye, using the Swedish Interactive Threshold Algorithm (24-2 SITA-Standard, Humphrey Field Analyzer II; Carl Zeiss Meditec, Inc, Dublin, California), during the period between January 1999 and September 2009 were included. Visual field progression was evaluated using automated pointwise linear regression. Evaluated data included age, sex, race, central corneal thickness, baseline VF mean deviation, mean follow-up IOP, peak IOP, IOP fluctuation, a detected disc hemorrhage, and presence of beta-zone parapapillary atrophy. Results: We selected 587 eyes of 587 patients (mean [SD] age, 64.9 [13.0] years). The mean (SD) number of VFs was 11.1 (3.0), spanning a mean (SD) of 6.4 (1.7) years. In the univariable model, older age (odds ratio [OR], 1.19 per decade; P = .01), baseline diagnosis of exfoliation syndrome (OR, 1.79; P = .01), decreased central corneal thickness (OR, 1.38 per 40 mu m thinner; P < .01), a detected disc hemorrhage (OR, 2.31; P < .01), presence of beta-zone parapapillary atrophy (OR, 2.17; P < .01), and all IOP parameters (mean follow-up, peak, and fluctuation; P < .01) were associated with increased risk of VF progression. In the multivariable model, peak IOP (OR, 1.13; P < .01), thinner central corneal thickness (OR, 1.45 per 40 mu m thinner; P < .01), a detected disc hemorrhage (OR, 2.59; P < .01), and presence of beta-zone parapapillary atrophy (OR, 2.38; P < .01) were associated with VF progression. Conclusions: IOP-dependent and IOP-independent risk factors affect disease progression in treated glaucoma. Peak IOP is a better predictor of progression than is IOP mean or fluctuation.
Resumo:
Purpose: To evaluate rates of visual field progression in eyes with optic disc hemorrhages and the effect of intraocular pressure (IOP) reduction on these rates. Design: Observational cohort study. Participants: The study included 510 eyes of 348 patients with glaucoma who were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS) and followed for an average of 8.2 years. Methods: Eyes were followed annually with clinical examination, standard automated perimetry visual fields, and optic disc stereophotographs. The presence of optic disc hemorrhages was determined on the basis of masked evaluation of optic disc stereophotographs. Evaluation of rates of visual field change during follow-up was performed using the visual field index (VFI). Main Outcome Measures: The evaluation of the effect of optic disc hemorrhages on rates of visual field progression was performed using random coefficient models. Estimates of rates of change for individual eyes were obtained by best linear unbiased prediction (BLUP). Results: During follow-up, 97 (19%) of the eyes had at least 1 episode of disc hemorrhage. The overall rate of VFI change in eyes with hemorrhages was significantly faster than in eyes without hemorrhages (-0.88%/year vs. -0.38%/year, respectively, P < 0.001). The difference in rates of visual field loss pre- and post-hemorrhage was significantly related to the reduction of IOP in the post-hemorrhage period compared with the pre-hemorrhage period (r = -0.61; P < 0.001). Each 1 mmHg of IOP reduction was associated with a difference of 0.31%/year in the rate of VFI change. Conclusions: There was a beneficial effect of treatment in slowing rates of progressive visual field loss in eyes with optic disc hemorrhage. Further research should elucidate the reasons why some patients with hemorrhages respond well to IOP reduction and others seem to continue to progress despite a significant reduction in IOP levels. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2010; 117: 2061-2066 (C) 2010 by the American Academy of Ophthalmology.
Resumo:
Objective: To investigate clinical and MRI findings that are predictive of both visual loss in patients with pituitary adenomas and visual recovery after treatment. Design: Cohort study. Participants: Thirty patients (60 eyes) with pituitary adenoma. Methods: Patients underwent neuro-ophthalmic examination and MRI before and after optic chiasm decompression. Visual field (VF) was assessed using the mean deviation in standard automated perimetry (SAP) and temporal mean defect, the average of 22 temporal values of the total deviation plot. Tumour size was measured on sagittal and coronal cuts. Results: Visual loss was found in 47 eyes; 35 had optic atrophy (subtle in 9, moderate in 14, and severe in 12). Before treatment, the average SAP mean deviation and temporal mean defect were -11.78 (SD 8.56) dB and -18.66 (SD 11.20) dB, respectively. The chiasm was 17.3 (SD 6.2, range 10-34) mm above the reference line on the sagittal and 21.8 (SD 8.3, range 12-39) mm on the coronal images. Tumour size correlated with the severity of VF defect. VF improvement occurred in 80% of eyes after treatment. The degree of optic atrophy, visual loss, and tumour size were significantly associated with improvement after treatment. Conclusions: The best predictive factor for visual loss was tumour size, and factors related to visual recovery were the degree of optic atrophy, the severity of VF defect, and the tumour size. Diagnosing pituitary adenomas before optic atrophy becomes severe may be related to a better prognosis in such patients.