922 resultados para visible transmission


Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper, the influence on optical properties of alkali halides such as CsCl in a covalent glassy matrix has been investigated. Chalcogenide glasses belonging to the (GeS2)-(Ga2S3)-CsCI system with high ratio of CsCl present an entire transparency in the visible range. These glasses maintain good transmission up to 12 mu m. Furthermore, the thermo-mechanical properties and the glass hygroscopicity have been investigated as function of the CsCl amount. This new generation of glasses presents a great interest for optical application. They could be used both for passive applications (multi-spectral imaging) and active applications for rare-earth doping due to their good transmission in the visible range, increasing optical pumping possibilities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present a study on the thin film morphology and the optical properties of eumelanin resulting from different synthesis routes: the oxidation of tyrosine with hydrogen peroxide, the auto-oxidation of dihydroxyphenylanaline in water and its auto-oxidation in dimethyl sulfoxid. Atomic Force Microscopy images indicate that the presence of holes and particles depends on the eumelanin synthesis route and the substrate employed. Smooth films with very few defects could be obtained with eumelanin synthesized in dimethyl sulfoxide deposited on glass substrates. Our study shows that all eumelanin preparations are comparable in terms of thin film morphology on the submicrometer scale and UV-visible transmission properties. ©The Electrochemical Society.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a newly designed polymer light-emitting diode with a bandwidth of ∼350 kHz for high-speed visible light communications. Using this new polymer light-emitting diode as a transmitter, we have achieved a record transmission speed of 10 Mb/s for a polymer light-emitting diode-based optical communication system with an orthogonal frequency division multiplexing technique, matching the performance of single carrier formats using multitap equalization. For achieving such a high data-rate, a power pre-emphasis technique was adopted. © 2014 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laponite-derived materials represent promising materials for optical applications. In this work, Eu(3+)- or Er(3+)-doped laponite xerogels and films were prepared from colloidal dispersion. Homogeneous, crack-free and transparent single layers were deposited on soda-lime substrates with a thickness of 10 mu m. Structural and spectroscopic properties were analyzed by thermal analyses, X-ray diffractometry, transmission electron microscopy, infrared spectroscopy, and luminescence spectroscopy. The addition of a rare earth ion to the laponite does not promote any changes in thermal stability or phase transition. Laponite clay was identified after annealing up to 500 degrees C, with a decrease in basal spacing when the annealing temperature is changed from 100 degrees C to 500 degrees C. Enstatite polymorphs and amorphous silicate phases were observed after heat treatment at 700 degrees C and 900 degrees C. Stationary and time-dependent luminescence spectra in the visible region for Eu(3+), and (5)D(0) lifetime are discussed in terms of thermal treatment and structural evolution. In the layered host, the Eu(3+) ions are distributed in many different local environments. However, Eu(3+) ions were found to occupy at least two symmetry sites, and the ions are preferentially incorporated into the crystalline enstatite for the materials annealed at 700 degrees C and 900 degrees C. A (5)D(0) lifetime of 1.3 ms and 3.1 ms was obtained for Eu(3+) ions in an amorphous silicate and crystalline MgSiO(3) local environment, respectively. Strong Er(3+) emission at the 1550 nm region was observed for the materials annealed at 900 degrees C, with a bandwidth of 44 nm. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Results on the use of a double a-SiC:H p-i-n heterostructure for signal multiplexing and demultiplexing applications in the visible range are presented. Pulsed monochromatic beams together (multiplexing mode), or a single polychromatic beam (demultiplexing mode) impinge on the device and are absorbed, accordingly to their wavelength. Red, green and blue pulsed input channels are transmitted together, each one with a specific transmission rate. The combined optical signal is analyzed by reading out, under different applied voltages, the generated photocurrent. Results show that in the multiplexing mode the output signal is balanced by the wavelength and transmission rate of each input channel, keeping the memory of the incoming optical carriers. In the demultiplexing mode the photocurrent is controlled by the applied voltage allowing regaining the transmitted information. A physical model supported by a numerical simulation gives insight into the device operation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we present results on the use of multilayered a-SiC:H heterostructures as a device for wavelength-division demultiplexing of optical signals. These devices are useful in optical communications applications that use the wavelength division multiplexing technique to encode multiple signals into the same transmission medium. The device is composed of two stacked p-i-n photodiodes, both optimized for the selective collection of photo generated carriers. Band gap engineering was used to adjust the photogeneration and recombination rate profiles of the intrinsic absorber regions of each photodiode to short and long wavelength absorption in the visible spectrum. The photocurrent signal using different input optical channels was analyzed at reverse and forward bias and under steady state illumination. A demux algorithm based on the voltage controlled sensitivity of the device was proposed and tested. An electrical model of the WDM device is presented and supported by the solution of the respective circuit equations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Le petit ouvrage de Roland Campiche répond à deux objectifs. Le premier est de rappeler au public helvétique que si la religion joue un rôle différent depuis 50 ans, elle n'en est pas moins demeurée un acteur de la scène tant publique que privée de notre pays. Le second est de défendre l'idée d'une dualisation de la religion. Cette notion n'est pas nouvelle, puisque le sociologue, fondateur de l'Observatoire des religions en Suisse (ORS) à l'Université de Lausanne, l'avait déjà émise dans son livre "Les deux visages de la religion".

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to improve the efficacy and safety of treatments, drug dosage needs to be adjusted to the actual needs of each patient in a truly personalized medicine approach. Key for widespread dosage adjustment is the availability of point-of-care devices able to measure plasma drug concentration in a simple, automated, and cost-effective fashion. In the present work, we introduce and test a portable, palm-sized transmission-localized surface plasmon resonance (T-LSPR) setup, comprised of off-the-shelf components and coupled with DNA-based aptamers specific to the antibiotic tobramycin (467 Da). The core of the T-LSPR setup are aptamer-functionalized gold nanoislands (NIs) deposited on a glass slide covered with fluorine-doped tin oxide (FTO), which acts as a biosensor. The gold NIs exhibit localized plasmon resonance in the visible range matching the sensitivity of the complementary metal oxide semiconductor (CMOS) image sensor employed as a light detector. The combination of gold NIs on the FTO substrate, causing NIs size and pattern irregularity, might reduce the overall sensitivity but confers extremely high stability in high-ionic solutions, allowing it to withstand numerous regeneration cycles without sensing losses. With this rather simple T-LSPR setup, we show real-time label-free detection of tobramycin in buffer, measuring concentrations down to 0.5 μM. We determined an affinity constant of the aptamer-tobramycin pair consistent with the value obtained using a commercial propagating-wave based SPR. Moreover, our label-free system can detect tobramycin in filtered undiluted blood serum, measuring concentrations down to 10 μM with a theoretical detection limit of 3.4 μM. While the association signal of tobramycin onto the aptamer is masked by the serum injection, the quantification of the captured tobramycin is possible during the dissociation phase and leads to a linear calibration curve for the concentrations over the tested range (10-80 μM). The plasmon shift following surface binding is calculated in terms of both plasmon peak location and hue, with the latter allowing faster data elaboration and real-time display of the results. The presented T-LSPR system shows for the first time label-free direct detection and quantification of a small molecule in the complex matrix of filtered undiluted blood serum. Its uncomplicated construction and compact size, together with the remarkable performances, represent a leap forward toward effective point-of-care devices for therapeutic drug concentration monitoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. West Nile Virus (WNV), a mosquito-borne flavivirus, is one of an increasing number of infectious diseases that have been emerging or re-emerging in the last two decades. Since the arrival ofWNV to Canada to present date, the Niagara Region has only reported 30 clinical cases, a small number compared to the hundreds reported in other regions of similar conditions. Moreover, the last reported human case in Niagara was in 2006. As it has been demonstrated that the majority of WNV infections are asymptomatic, the question remains whether the lack of clinical cases in Niagara truly reflects the lack of transmission to humans or if infections are still occurring but are mostly asymptomatic. Objectives. The general objective of this study was to establish whether or not active WNV transmission could be detected in a human population residing in Niagara for the 2007 transmission season. To fullfil this objective, a cross-sectional seroprevalence study was designed to investigate for the presence of anti-WNV antibodies in a sample of Mexican migrant agricultural workers employed in farms registered with the Seasonal Agricultural Workers Program (SAWP). Due to the Mexican origin of the study participants, three specific research objectives were proposed: a) determine the seroprevalence ofanti-WNV antibodies as well as anti-Dengue virus antibodies (a closely related virus prevalent in Mexico and likely to confound WNV serology); b) analyze risk factors associated with WNV and Dengue virus seropositivity; and c) assess the awareness of study participants about WNV infection as well as their understanding of the mode of transmission and clinical importance of the infection. Methodology: After obtaining ethics clearance from Brock University, farms were visited and workers invited to participate. Due to time constraints, only a small number of farms were enrolled with a resulting convenience and non-randomized study sample. Workers' demographic and epidemiological data were collected using a standardized questionnaire and blood samples were drawn to determine serum anti-WNV and anti- Dengue antibodies with a commercial ELISA. All positive samples were sent to the National Microbiology Laboratory in Winnipeg, Manitoba for confirmation with the Plaque Reduction Neutralization Test (PRNT). Data was analyzed with Stata 10.0. Antibody determinations were reported as seroprevalence proportions for both WNV and Dengue. Logistic regression was used to analyze risk factors that may be associated with seropositivity and awareness was reported as a proportion of the number of individuals possessing awareness over the total number of participants. Results and Discussion. In total 92 participants working in 5 farms completed the study. Using the commercial ELISA, seropositivity was as follows: 2.2% for WNV IgM, 20.7% for WNV IgG, and 17.1 % for Dengue IgG. Possible cross-reactivity was demonstrated in 15/20 (75.0%) samples that were positive for both WNV IgG and Dengue IgG. Confirmatory testing with the PRNT demonstrated that none of the WNV ELISA positive samples had antibodies to WNV but 13 samples tested positive for anti-Dengue antibodies (14.1 % Dengue sereoprevalence). The findings showed that the ELISA performance was very poor for assessing anti-WNV antibodies in individuals previously exposed to Dengue virus. However, the ELISA had better sensitivity and specificity for assessing anti-Dengue antibodies. Whereas statistical analysis could not be done for WNV seropositivity, as all samples were PRNT negative, logistic regression demonstrated several risk factors for Dengue exposure_ The first year coming to Canada appeared to be significantly associated with increased exposure to Dengue while lower socio-economic housing and the presence of a water basin in the yard in Mexico appeared to be significantly associated with a decreased exposure to Dengue_ These seemingly contradictory results illustrate that in mobile populations such as migrant workers, risk factors for exposure to Dengue are not easily identified and more research is needed. Assessing the awareness of WNV and its clinical importance showed that only 23% of participants had some knowledge of WNV, of which 76% knew that the infection was mosquito-borne and 47% recognized fever as a symptom. The identified lack of understanding and awareness was not surprising since WNV is not a visible disease in Mexico. Since WNV persists in an enzootic cycle in Niagara and the occurrence of future outbreaks is unpredictable, the agricultural workers remain at risk for transmission. Therefore it important they receive sufficient health education regarding WNV before leaving Mexico and during their stay in Canada. Conclusions. Human transmission of WNV could not be proven among the study participants even when due to their occupation they are at high risk for mosquito bites. The limitations of the study sample do not permit generalizable conclusions, however, the study findings are consistent with the absence of clinical cases in the Niagara Region, so it is likely that human transmission is indeed neglible or absent. As evidenced by our WNV serology results, PRNT must be utilized as a confirmatory test since false positivity occurs frequently. This is especially true when previous exposure to Dengue virus is likely.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tunable Optical Sensor Arrays (TOSA) based on Fabry-Pérot (FP) filters, for high quality spectroscopic applications in the visible and near infrared spectral range are investigated within this work. The optical performance of the FP filters is improved by using ion beam sputtered niobium pentoxide (Nb2O5) and silicon dioxide (SiO2) Distributed Bragg Reflectors (DBRs) as mirrors. Due to their high refractive index contrast, only a few alternating pairs of Nb2O5 and SiO2 films can achieve DBRs with high reflectivity in a wide spectral range, while ion beam sputter deposition (IBSD) is utilized due to its ability to produce films with high optical purity. However, IBSD films are highly stressed; resulting in stress induced mirror curvature and suspension bending in the free standing filter suspensions of the MEMS (Micro-Electro-Mechanical Systems) FP filters. Stress induced mirror curvature results in filter transmission line degradation, while suspension bending results in high required filter tuning voltages. Moreover, stress induced suspension bending results in higher order mode filter operation which in turn degrades the optical resolution of the filter. Therefore, the deposition process is optimized to achieve both near zero absorption and low residual stress. High energy ion bombardment during film deposition is utilized to reduce the film density, and hence the film compressive stress. Utilizing this technique, the compressive stress of Nb2O5 is reduced by ~43%, while that for SiO2 is reduced by ~40%. Filters fabricated with stress reduced films show curvatures as low as 100 nm for 70 μm mirrors. To reduce the stress induced bending in the free standing filter suspensions, a stress optimized multi-layer suspension design is presented; with a tensile stressed metal sandwiched between two compressively stressed films. The stress in Physical Vapor Deposited (PVD) metals is therefore characterized for use as filter top-electrode and stress compensating layer. Surface micromachining is used to fabricate tunable FP filters in the visible spectral range using the above mentioned design. The upward bending of the suspensions is reduced from several micrometers to less than 100 nm and 250 nm for two different suspension layer combinations. Mechanical tuning of up to 188 nm is obtained by applying 40 V of actuation voltage. Alternatively, a filter line with transmission of 65.5%, Full Width at Half Maximum (FWHM) of 10.5 nm and a stopband of 170 nm (at an output wavelength of 594 nm) is achieved. Numerical model simulations are also performed to study the validity of the stress optimized suspension design for the near infrared spectral range, wherein membrane displacement and suspension deformation due to material residual stress is studied. Two bandpass filter designs based on quarter-wave and non-quarter-wave layers are presented as integral components of the TOSA. With a filter passband of 135 nm and a broad stopband of over 650 nm, high average filter transmission of 88% is achieved inside the passband, while maximum filter transmission of less than 1.6% outside the passband is achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: We present an iterative framework for CT reconstruction from transmission ultrasound data which accurately and efficiently models the strong refraction effects that occur in our target application: Imaging the female breast. Methods: Our refractive ray tracing framework has its foundation in the fast marching method (FNMM) and it allows an accurate as well as efficient modeling of curved rays. We also describe a novel regularization scheme that yields further significant reconstruction quality improvements. A final contribution is the development of a realistic anthropomorphic digital breast phantom based on the NIH Visible Female data set. Results: Our system is able to resolve very fine details even in the presence of significant noise, and it reconstructs both sound speed and attenuation data. Excellent correspondence with a traditional, but significantly more computationally expensive wave equation solver is achieved. Conclusions: Apart from the accurate modeling of curved rays, decisive factors have also been our regularization scheme and the high-quality interpolation filter we have used. An added benefit of our framework is that it accelerates well on GPUs where we have shown that clinical 3D reconstruction speeds on the order of minutes are possible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

intense photoluminescence in the visible region was observed at room temperature in standard soda-lime-silica glass powder, mechanically milled in a high-energy attrition mill. The emission band maximum shows an interesting dependence on the exciting wavelength, suggesting the possibility to tune the PL emission. These findings indicate that the photoluminescence may be directly related to unsatisfied chemical bonds correlated with the high surface area. The Raman scattering and ultraviolet-visible optical reflectance measurements corroborate this assertion. Transmission electron microscopy measurements indicate that samples milled more than 10 h present the formation of nanocrystallites with about 10-20 nm. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ITO nanowires were synthesized by carbothermal reduction process, using a co-evaporation method, and have controlled size, shape, and chemical composition. The electrical measurements of nanowires showed they have a resistance of about 102 Ω. In order to produce nanocomposites films, nanowires were dispersed in toluene using an ultrasonic cleaner, so the PMMA polymer was added, and the system was kept under agitation up to obtain a clear suspension. The PMMA polymer was filled with 1, 2, 5 and 10% in weight of nanowires, and the films were done by tape casting. The results showed that the electrical resistance of nanocomposites changed by over 7 orders of magnitude by increasing the amount of filler, and using 5 wt% of filler the composite resistance decreased from 1010 Ω to about 104 Ω, which means that percolation threshold of wires occurred at this concentration. This is an interesting result once for nanocomposites filled with ITO nanoparticles is necessary about 18% in weight to obtain percolation. The addition of filler up to 10 wt% decreased the resistance of the composite to 103 Ω, which is a value close to the resistance of wires. The composites were also analyzed by transmission electron microscopy (TEM), and the TEM results are in agreement with the electrical ones about percolation of nanowires. These results are promising once indicates that is possible to produce conductive and transparent in the visible range films by the addition of ITO nanowires in a polymeric matrix using a simple route. © 2011 Materials Research Society.