899 resultados para visible losses
Resumo:
The system of mechanized harvesting can seek process improvements using quality tools that can assist in reducing losses, damaged ratoons and increase the longevity of sugarcane crop. Therefore, the objective this study was to detect the effective control of the variability of losses and damage to ratoon and identify whether they are within acceptable standards. Thus, 40 points were sampled in two periods of harvest, diurnal and nocturnal, in rectangular grids (55 x 45 m) for determining visible losses (whole and shattered billets, fixed and loose piece, stump and shrapnel), using frames of 10 m(2). Also, we measured the height of cut and degree of damage to ratoon (without damage, partial injury and fragmentation). The statistic used was descriptive variables for the loss of sugarcane during the diurnal (D) and nocturnal (N) periods, analysis of variance using the F test at 5% probability and the Tukey test for comparison of the mean, also using the statistical control through charts process. There was no difference to ratoon damage. In the process of harvest, losses of whole and shattered billets by grinding were considered under control, so as losses from the stump. on the other hand, the losses of fixed piece, shrapnel and whole-cane were not controlled. The cutting height and total losses were higher during the nocturnal harvest. The charts were shown to be effective for the evaluation of control process of diurnal and nocturnal harvests.
Resumo:
O avanço da mecanização na colheita da cana-de-açúcar (Saccharum spp.) proporcionou o uso de novas tecnologias e ganho em produtividade para a cultura. O controle da qualidade do processo de colheita da cana-de-açúcar é fundamental para reduzir as perdas. Este trabalho teve o objetivo de avaliar as perdas na colheita mecanizada de cana-de-açúcar, utilizando-as como indicadores de qualidade do processo de colheita. Os dados foram coletados em duas propriedades próximas a Jaboticabal - SP, com a variedade SP80-3280, em 3º e 4º cortes. Caracterizou-se o porte do canavial e, após a colheita, demarcou-se área de 1,5 ha, sendo demarcados 25 pontos, espaçados de 12 x 50 m, quantificando-se as perdas visíveis. Posteriormente, foi aplicado o controle estatístico do processo pela média, que consta de três vezes o desvio-padrão para mais ou para menos, sendo esses os limites superior e inferior de controle, respectivamente. A média das perdas de pedaço solto foi estatisticamente maior do que as médias de perdas em pedaço fixo, cana inteira, cana-ponta e toco. A ocorrência de perdas em rebolo estilhaçado foi menor para o 4º corte em relação ao 3º corte, enquanto as perdas em pedaço fixo e toco foram menores no 3º corte, comparadas às perdas no 4º corte. em cada corte, as médias para as perdas totais estiveram próximas dos valores encontrados na bibliografia. Pedaço solto foi a variável de perdas visíveis com maior percentagem de ocorrência. As perdas demonstraram que a colheita mecanizada não se encontra sob controle estatístico de processo.
Resumo:
Organic-inorganic hybrids were prepared using ureapropyltriethoxysilane, methacryloxypropyltrimethoxysilane and acrylic acid modified zirconium(IV) n-propoxide precursors and were characterized by small angle X-ray scattering, X-ray diffraction and photoluminescence spectroscopy. The results indicate an effective interaction between the zirconium-based nanoparticles and the siliceous nanodomains that induces changes in the hybrids' emission features. Planar waveguides were obtained by spin-coating of the prepared sols on sodalime and silica substrates. Refractive index, thickness, number of propagating modes, and attenuation coefficient were measured at 543.5, 632.8 and 1550 nm by the prism coupling technique. The synergism between the two hybrid precursors resulted in monomode planar waveguides with low losses in the infrared ( from 0.6-1.1 dB cm(-1)) which also support a number of propagating modes in the visible ( losses from 0.4-1.5 dB cm(-1)). Channel waveguides were also obtained by UV photopatterning using amplitude or phase masks and propagating modes were observed at 1550 nm.
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The work presented here demonstrates the feasibility of using the single-mode fibers of an optical Internet network to deliver visible light between separate laboratories as a way to perform remote spectroscopy in the visible for teaching purposes. The coupling of a broadband light source into the single-mode fiber (SMF) and the characterization of optical losses as a function of the wavelength are discussed. Sample spectra were measured with a portable spectrometer controlled by an acquisition program developed with the LabVIEW software that allows the data to be collected and analyzed.
Resumo:
PURPOSE: To explore the effects of glaucoma and aging on low-spatial-frequency contrast sensitivity by using tests designed to assess performance of either the magnocellular (M) or parvocellular (P) visual pathways. METHODS: Contrast sensitivity was measured for spatial frequencies of 0.25 to 2 cyc/deg by using a published steady- and pulsed-pedestal approach. Sixteen patients with glaucoma and 16 approximately age-matched control subjects participated. Patients with glaucoma were tested foveally and at two midperipheral locations: (1) an area of early visual field loss, and (2) an area of normal visual field. Control subjects were assessed in matched locations. An additional group of 12 younger control subjects (aged 20-35 years) were also tested. RESULTS: Older control subjects demonstrated reduced sensitivity relative to the younger group for the steady (presumed M)- and pulsed (presumed P)-pedestal conditions. Sensitivity was reduced foveally and in the midperiphery across the spatial frequency range. In the area of early visual field loss, the glaucoma group demonstrated further sensitivity reduction relative to older control subjects across the spatial frequency range for both the steady- and pulsed-pedestal tasks. Sensitivity was also reduced in the midperipheral location of "normal" visual field for the pulsed condition. CONCLUSIONS: Normal aging results in a reduction of contrast sensitivity for the low-spatial-frequency-sensitive components of both the M and P pathways. Glaucoma results in a further reduction of sensitivity that is not selective for M or P function. The low-spatial-frequency-sensitive channels of both pathways, which are presumably mediated by cells with larger receptive fields, are approximately equivalently impaired in early glaucoma.
Resumo:
Qualitative research methods require transparency to ensure the ‘trustworthiness’ of the data analysis. The intricate processes of organizing, coding and analyzing the data are often rendered invisible in the presentation of the research findings, which requires a ‘leap of faith’ for the reader. Computer assisted data analysis software can be used to make the research process more transparent, without sacrificing rich, interpretive analysis by the researcher. This article describes in detail how one software package was used in a poststructural study to link and code multiple forms of data to four research questions for fine-grained analysis. This description will be useful for researchers seeking to use qualitative data analysis software as an analytic tool.
Resumo:
Dolomite mineral samples having white and light green colours of Indian origin have been characterized by EPR, optical and NIR spectroscopy. The optical spectrum exhibits a number of electronic bands due to presence of Fe(III) ions in the mineral. From EPR studies, the parameters of g for Fe(III) and g, A and D for Mn(II) are evaluated and the data confirm that the ions are in distorted octahedron. Optical absorption studies reveal that Fe(III) is in distorted octahedron. The bands in NIR spectra are due to the overtones and combinations of water molecules. Thus EPR and optical absorption spectral studies have proven useful for the study of the chemistry of dolomite.