999 resultados para velocity transducer


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the work related to characterisation of an ultrasonic transducer fabricated in the laboratory. The response of the medium to the ultrasonic wave was obtained by converting the time domain signal to frequency domain, using the FFT algorithm. Cross-correlation technique was adopted to increase the S/N ratio in the raw time domain signal and subsequently, to determine the ultrasonic velocity in the medium.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In normal dogs and dogs with subaortic stenosis, it is known that the subcostal transducer site provides higher left ventricular ejection velocities than does the left apical site. We hypothesized that aortic flow velocities could also be obtained from the right parasternal long-axis view, optimized for the placement of the Doppler cursor as parallel as possible into the aortic root. In 15 healthy dogs and 13 healthy cats, high-pulsed repetition frequency Doppler flow velocity measurements in the proximal aorta were performed using two-dimensional echocardiographic guidance. The mean [ +/- standard error of the mean (SEM)] peak aortic flow velocities in healthy dogs were as follows: subcostal site 1.46 +/- 0.05 m/s; apical site 1.12 +/- 0.06 m/s; right parasternal long-axis site 1.09 +/- 0.05 m/s. In healthy cats, the following peak aortic flow velocities were observed: apical site 0.87 +/- 0.03m/s; right parasternal long-axis site 0.87 +/- 0.03 m/s. Aortic flow velocities obtained from the subcostal site were significantly higher in healthy dogs than those obtained from the left apical and right parasternal long-axis site (P< 0.001). There was no statistical difference between the peak aortic flow velocities obtained from right parasternal long-axis and left apical transducer position in all groups. We conclude therefore that right parasternal long-axis and left apical-derived aortic flow velocities are similar and may be used interchangeably in healthy dogs and cats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The wake produced by the structural supports of the ultrasonic anemometers (UAs)causes distortions in the velocity field in the vicinity of the sonic path. These distortions are measured by the UA, inducing errors in the determination of the mean velocity, turbulence intensity, spectrum, etc.; basic parameters to determine the effect of wind on structures. Additionally, these distortions can lead to indefinition in the calibration function of the sensors (Cuerva et al., 2004). Several wind tunnel tests have been dedicated to obtaining experimental data, from which have been developed fit models to describe and to correct these distortions (Kaimal, 1978 and Wyngaard, 1985). This work explores the effect of a vortex wake generated by the supports of an UA, on the measurement of wind speed done by this instrument. To do this, the Von Karman¿s vortex street potential model is combined with the mathematical model of the measuring process carried out by UAs developed by Franchini et al. (2007). The obtained results are the correction functions of the measured wind velocity, which depends on the geometry of the sonic anemometer and aerodynamic conditions. These results have been validated with the ones obtained in a wind tunnel test done on a single path UA, especially developed for research. The supports of this UA have been modified in order to reproduce the conditions of the theoretical model. Good agreements between experimental and theoretical results have been found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Understanding arterial distensibility has shown to be important in the pathogenesis of cardiovascular abnormalities like hypertension. It is also known that arterial pulse wave velocity (PWV) is a measure of the elasticity or stiffness of peripheral arterial blood vessels. However, it generally requires complex instrumentations to have an accurate measurement and not suited for continual monitoring. In this paper, it describes a simple and non-intrusive method to detect the cardiovascular pulse from a human wrist above the radial artery and a fingertip. The main components of this proposed method are a piezoelectric transducer and a photo-plethysmography circuitry. 5 healthy adults (4 male) with age ranging from 25 to 38 years were recruited. The timing consistency of the detected pulsations is first evaluated and compared to that obtained from a commercial electrocardiogram. Furthermore, the derived PWV is then assessed by the predicted values attained from regression equations of two previous similar studies. The results show good correlations (p < 0.05) and similarities for the former and latter respectively. The simplicity and non-invasive nature of the proposed method can be attractive for even younger or badly disturbed patients. Moreover, it can be used for prolonged monitoring for the comfort of the patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work described in this thesis is the development of an ultrasonic tomogram to provide outlines of cross-sections of the ulna in vivo. This instrument, used in conjunction with X-ray densitometry previously developed in this department, would provide actual bone mineral density to a high resolution. It was hoped that the accuracy of the plot obtained from the tomogram would exceed that of existing ultrasonic techniques by about five times. Repeat measurements with these instruments to follow bone mineral changes would involve very low X-ray doses. A theoretical study has been made of acoustic diffraction, using a geometrical transform applicable to the integration of three different Green's functions, for axisymmetric systems. This has involved the derivation of one of these in a form amenable to computation. It is considered that this function fits the boundary conditions occurring in medical ultrasonography more closely than those used previously. A three dimensional plot of the pressure field using this function has been made for a ring transducer, in addition to that for disc transducers using all three functions. It has been shown how the theory may be extended to investigate the nature and magnitude of the particle velocity, at any point in the field, for the three functions mentioned. From this study. a concept of diffraction fronts has been developed, which has made it possible to determine energy flow also in a diffracting system. Intensity has been displayed in a manner similar to that used for pressure. Plots have been made of diffraction fronts and energy flow direction lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two-stroke outboard boat engines using total loss lubrication deposit a significant proportion of their lubricant and fuel directly into the water. The purpose of this work is to document the velocity and concentration field characteristics of a submerged swirling water jet emanating from a propeller in order to provide information on its fundamental characteristics. Measurements of the velocity and concentration field were performed in a turbulent jet generated by a model boat propeller (0.02 m diameter) operating at 1500 rpm and 3000 rpm. The measurements were carried out in the Zone of Established Flow up to 50 propeller diameters downstream of the propeller. Both the mean axial velocity profile and the mean concentration profile showed self-similarity. Further, the stand deviation growth curve was linear. The effects of propeller speed and dye release location were also investigated.