946 resultados para vein diameter


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Duplex ultrasound scanning (DUS) is the method of choice for diagnosis of deep vein thrombosis (DVT). However, only a few studies have performed prospective serial DUS after an acute episode of DVT to assess its evolution. This study aimed to report our experience using DUS combined with a thrombosis score (TS) and a newly proposed vein diameter variation index (VDVI) to evaluate the rate of resolution of DVT by assessing and quantifying the early stages of vein recanalization in proximal vein segments within 6 months after an episode of acute lower extremity DVT.Methods: Twelve patients with first episode of acute lower extremity DVT confirmed by DUS as occurring in <= 10 days after the onset of venous thrombosis symptoms were followed up prospectively for 6 months. TS and VDVI were calculated at 1, 3, and 6 months to assess vein recanalization. Intra-thrombus arteriovenous fistula formation was also investigated and related to the recanalization process.Results: Seven (58%) women were included, with a total cohort median age of 53.5 +/- 19 years. The left lower extremity was affected in 7 (58%) patients. DVT was diagnosed in 55 proximal vein segments. All patients had proximal DVT, with involvement of the external iliac, femoral, and popliteal veins. After 6 months, there was a significant decrease in TS and increase in VDVI (P < 0.001) in all proximal vein segments assessed, indicating thrombus regression. The more distal the DVT was, the faster was the VDVI increase, with most popliteal veins being recanalized at 3 months (P < 0.001). Intra-thrombus arteriovenous fistula was identified in 50% of patients at 1 month while on anticoagulation.Conclusions: The combined use of two different DUS-based assessment tools, TS and the proposed VDVI, provided an effective method to prospectively assess vein recanalization rates after an episode of acute lower extremity DVT in this series of patients and may allow a correct evaluation of DVT and its resolution or progression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Choosing an appropriately sized vein reduces the risk of venous thromboembolism associated with peripherally inserted central catheters. This observational study described the diameters of the brachial, basilic, and cephalic veins and determined the effect of patient factors on vein size. Ultrasound was used to measure the veins of 176 participants. Vein diameter was similar in both arms regardless of hand dominance and side. Patient factors-including greater age, height, and weight, as well as male gender-were associated with increased vein diameter. The basilic vein tended to have the largest diameter statistically. However, this was the case in only 55% of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The risk of venous thromboembolism (VTE) may be reduced if a vein of appropriate diameter is used forperipherally inserted central catheter (PICC) insertion. However, clinicians may have predilections to cannulate certainvein types and use particular insertion sites (eg, right or left arm) and therefore do not necessarily assess all veinsavailable to determine the most optimal vessel to introduce a catheter. It is important that clinicians have anunderstanding of the diameter of veins used for PICC insertion and the effect of patient factors such as hand dominanceon vein size to determine whether their clinical practice is appropriate.

Methods: A scoping review of published literature was performed to determine existing knowledge regarding thediameters of veins used for PICC insertion and the influence of patient factors such as hand dominance and laterality(left or right arm) on vein size.

Results: There was limited published research about the diameters of the basilic, brachial, and cephalic veins at themidupper arm, with only 6 studies identified. Three of the 6 selected articles focused on vein diameter measurement toinform arteriovenous fistula development. Only 1 study included participants undergoing PICC insertion. Scant researchexamined the effect of laterality on vein diameter and 1 study was identified that reported the influence of handdominance or vein type on the diameter of veins used for PICC insertion.

Conclusions: This review found that there is a paucity of studies that have examined the veins used for PICC insertion.Nevertheless, it appears that the basilic vein has the largest diameter (with smaller brachial and cephalic veins),although this is not always the case. Laterality and hand dominance does not seem to influence vein diameter. Furtherresearch about the vasculature used for PICC insertion is needed to inform clinical practice.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cold water immersion (CWI) is a popular recovery modality, but actual physiological responses to CWI after exercise in the heat have not been well documented. The purpose of this study was to examine effects of 20-min CWI (14 degrees C) on neuromuscular function, rectal (T(re)) and skin temperature (T(sk)), and femoral venous diameter after exercise in the heat. Ten well-trained male cyclists completed two bouts of exercise consisting of 90-min cycling at a constant power output (216+/-12W) followed by a 16.1km time trial (TT) in the heat (32 degrees C). Twenty-five minutes post-TT, participants were assigned to either CWI or control (CON) recovery conditions in a counterbalanced order. T(re) and T(sk) were recorded continuously, and maximal voluntary isometric contraction torque of the knee extensors (MVIC), MVIC with superimposed electrical stimulation (SMVIC), and femoral venous diameters were measured prior to exercise, 0, 45, and 90min post-TT. T(re) was significantly lower in CWI beginning 50min post-TT compared with CON, and T(sk) was significantly lower in CWI beginning 25min post-TT compared with CON. Decreases in MVIC, and SMVIC torque after the TT were significantly greater for CWI compared with CON; differences persisted 90min post-TT. Femoral vein diameter was approximately 9% smaller for CWI compared with CON at 45min post-TT. These results suggest that CWI decreases T(re), but has a negative effect on neuromuscular function.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Peripherally inserted central catheters (PICCs) are a common vascular access device used in clinical practice. Their use may be complicated by adverse events such as venous thromboembolism (VTE). The size of the vein used for PICC insertion and thus the catheter to vein ratio is thought to be a controllable factor in the reduction of VTE rates in patients who have a PICC. However, an optimal catheter to vein ratio for PICC insertion has not previously been investigated to inform clinical practice. OBJECTIVES: To determine the effect of the catheter to vein ratio (proportion of the vein measured at the insertion point taken up by the catheter) on rates of symptomatic VTE in patients with a PICC and identify the optimal ratio cut-off point to reduce rates of this adverse event. METHOD: Adult patients waiting for PICC insertion at a large metropolitan teaching hospital were recruited between May and December 2013. Vein diameter at the PICC insertion site was measured using ultrasound with in-built callipers. Participants were followed up at eight weeks to determine if they developed symptomatic VTE. RESULTS: Data were available for 136 patients (50% cancer; 44% infection; 6% other indication for PICC). Mean age was 57 years with 54% males. There were four cases of confirmed symptomatic VTE (two involving the deep veins, one peripheral vein and one pulmonary embolism). Receiver operator characteristic (ROC) analysis determined that a 45% catheter to vein ratio was the ideal cut off point to maximise sensitivity and specificity (AUC 0.761; 95% CI 0.681-0.830). When a ratio of 46% or above was compared to one that was less than or equal to 45% using a log binomial generalised linear model it was found that participants with a catheter to vein ratio >45% were 13 times more likely to suffer VTE (relative risk 13, p=0.022; CI 1.445-122.788). CONCLUSION: It was found that a 45% catheter to vein ratio was the optimal cut off with high sensitivity and specificity to reduce the risk of VTE. However, further research is needed to confirm these results as although adequately powered; the number of cases of VTE was comparatively small, resulting in wide confidence intervals.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Peripherally inserted central catheters (PICCs) are increasingly inserted by trained registered nurses, necessitating the development of specialized skills such as the use of ultrasound. The selection of an adequately sized vein is an important factor in reducing adverse events such as deep vein thrombosis. However, PICC nurses may receive minimal training in the use of ultrasound for vein measurement. Objective We aimed to demonstrate the reliability of a vein measurement protocol using ultrasound by a PICC nurse trained in sonography. Methods The diameter of the basilic, brachial, and cephalic veins in the left arms of healthy participants (n = 12) were measured using ultrasound by a PICC nurse and a sonographer. A PICC nurse performed the measurement twice and the sonographer once; the PICC nurse's results were compared for intra-rater reliability and compared with the sonographer for inter-rater reliability. The results were analyzed using intraclass correlation coefficients (ICCs). Results Inter-rater reliability between the PICC nurse and the sonographer was adequate, the ICC for the brachial vein was 0.60 (95% confidence interval [CI], 0.06-0.87), basilic vein ICC was 0.87 (95% CI, 0.58-0.96) and cephalic vein ICC was 0.77 (95% CI, 0.39-0.93). Intra-rater reliability of the PICC nurse was higher; the ICC for the brachial vein was 0.80 (95% CI, 0.44-0.94), basilic vein ICC was 0.92 (95% CI, 0.67-0.98), and cephalic vein ICC was 0.78 (95% CI, 0.40-0.93). Conclusions Using a suitable protocol, a PICC nurse was able to measure vein diameter reliably when compared with a sonographer and consistently replicate these results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to investigate endothelial venous function, mflammatory markers, and systemic oxidative stress after an oral lipid overload (OLO). We studied 18 healthy adults (9 men; age, 29.2 +/- 0.9 years; body mass index, 22.3 +/- 0.4 kg/m(2)). Blood samples were collected in the fasting state and 3, 4, and 5 hour after the OLO (1000 kcal, 58% fat) for metabolic variables, oxidative stress, inflammatory markers, adiponectin, and resistin. Changes in vein diameter to phenylephrine, acetylcholine, and sodium nitroprusside (dorsal hand vein technique) were measured before and after the OLO. Oral lipid overload increased triglycerides (61 +/- 6 vs 134 +/- 17 mg/dL, P <.001), insulin (7.2 +/- 0.8 vs 10.7 +/- 1.3 mu U/mL, P <.05), and resistin (5.38 +/- 0.5 vs 6.81 +/- 0.7 ng/mL, P <.05) and reduced antioxidant capacity (plasma total antioxidant capacity: 186.7 +/- 56 vs 161.8 +/- 50 U Trolox per microliter plasma, P <.01), vascular reactivity (171.3 +/- 85 vs 894.4 +/- 301 ng/mL, P <.001), and maximum acetylcholine venodilation (105.9% +/- 9% vs 61.0% +/- 7%, P <.05). No changes were observed for sodium nitroprusside. Post-OLO triglycerides were positively correlated with phenylephrine dose (rho = 0.38, P <.05) and resistin (rho = 0.43, P <.01) and negatively correlated with the maximum acetylcholine venodilation (rho = -0.36, P <.05). In conclusion, an OLO impaired venoconstriction responsiveness in healthy subjects, probably because of a reduction in the antioxidant capacity. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a case of a 71-year-old man with a long coronary artery disease history and two sets of coronary artery bypass grafts. He developed large aortocoronary saphenous vein graft aneurysms in the two grafts from the first set of aortocoronary saphenous venous 20 years later. During the previous 3 years, the aneurysms grew in diameter from 22 to 50 mm. Because of severe renal insufficiency, and in order to avoid jeopardizing the late normal coronary artery bypass grafts by further thoracic surgery, we excluded successfully these altered grafts percutaneously by using 13 coils during the same procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An equine, American Troter, female, 5 years of age, was referred to the Diagnostic Imaging Sector at the Veterinary Hospital of the FMVZ, Unesp, Botucatu Campus, with suspected jugular thrombosis. Ultrasonographic findings were heterogeneous tissue at the lumen of the right jugular vein with blockage of its diameter and collateral blood flow formation.