997 resultados para vascular ultrasonography


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trauma care in the general population has largely become protocol-driven, with an emphasis on fast and efficient treatment, good team communication at all levels of care including prehospital care, initial resuscitation, intensive care, and rehabilitation. Most available literature on trauma care has focused on adults, allowing the potential to apply concepts from adult care to pediatric care. But there remain issues that will always be specific to pediatric patients that may not translate from adults. Several new devices such as intraosseous (IO) needle systems and techniques such as ultrasonography to cannulate central and peripheral veins have become available for integration into our pre-existing trauma care system for children. This review will focus specifically on the latest techniques and evidence available for establishing intravenous access, rational approaches to fluid resuscitation, and blood product transfusion in the pediatric trauma patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The identification of pre-clinical microvascular damage in hypertension by non-invasive techniques has proved frustrating for clinicians. This proof of concept study investigated whether entropy, a novel summary measure for characterizing blood velocity waveforms, is altered in participants with hypertension and may therefore be useful in risk stratification.

Methods: Doppler ultrasound waveforms were obtained from the carotid and retrobulbar circulation in 42 participants with uncomplicated grade 1 hypertension (mean systolic/diastolic blood pressure (BP) 142/92 mmHg), and 26 healthy controls (mean systolic/diastolic BP 116/69 mmHg). Mean wavelet entropy was derived from flow-velocity data and compared with traditional haemodynamic measures of microvascular function, namely the resistive and pulsatility indices.

Results: Entropy, was significantly higher in control participants in the central retinal artery (CRA) (differential mean 0.11 (standard error 0.05 cms(-1)), CI 0.009 to 0.219, p 0.017) and ophthalmic artery (0.12 (0.05), CI 0.004 to 0.215, p 0.04). In comparison, the resistive index (0.12 (0.05), CI 0.005 to 0.226, p 0.029) and pulsatility index (0.96 (0.38), CI 0.19 to 1.72, p 0.015) showed significant differences between groups in the CRA alone. Regression analysis indicated that entropy was significantly influenced by age and systolic blood pressure (r values 0.4-0.6). None of the measures were significantly altered in the larger conduit vessel.

Conclusion: This is the first application of entropy to human blood velocity waveform analysis and shows that this new technique has the ability to discriminate health from early hypertensive disease, thereby promoting the early identification of cardiovascular disease in a young hypertensive population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This study examined whether patellar tendon vascularity could be quantified accurately in the clinical setting using colour Doppler ultrasonography.

Methods: A sonographer and two radiologists visually estimated tendon vascularity in millimetres in 74 tendons during ultrasound (US) examination and from hard copy films. These estimates were then compared to the length of vessels measured from the digital image in millimetres and the correlation between them was determined. A subset of 16 tendons was used to compare the estimates of vascularity by two examiners at US examination.

Results: The estimation of vascular length at US examination correlated highly with the measured vascular length (r = 0.92; 95% confidence interval (CI) 0.87 to 0.94), as did the length estimated from the films (r = 0.94; 95% CI 0.9 to 0.96). The correlation between examiners was 0.84 (95% CI 0.51 to 0.94) for the estimates made during US examination and 0.85 (95% CI 0.59 to 0.95) for the vessel lengths measured from the digital images.

Conclusions: These excellent correlations indicate that tendon vascularity can be reliably estimated using colour Doppler ultrasonography and tendon vascularity could therefore be used by clinicians to rate clinical change. This method of quantifying tendon vascularity could also be used in research to investigate the effects of tendon treatments on vascularity.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A disfunção autonômica está associada com aumento da mortalidade em pacientes diabéticos, especialmente naqueles com doença cardiovascular. Neuropatia periférica, mau controle glicêmico, dislipidemia e hipertensão são alguns dos fatores de risco para o desenvolvimento de doença vascular periférica (DVP) nestes pacientes. O objetivo deste estudo foi avaliar os fatores de risco associados com a presença de DVP em pacientes com DM tipo 2. Um estudo transversal foi realizado em 84 pacientes com DM tipo 2 ( 39 homens, idade média de 64,9 ± 7,5 anos). Os pacientes foram submetidos a uma avaliação clínica e laboratorial. A presença de DVP foi definida, utilizando-se um um aparelho manual de ultrasom com doppler (índice perna-braço < 0,9). A atividade autonômica foi avaliada através da análise da variabilidade da freqüência cardíaca (HRV) por métodos no domínio do tempo e da freqüência (análise espectral), e pelo mapa de retorno tridimensional durante o período do dia e da noite. Para a análise da HRV, um eletrocardiograma de 24 horas foi gravado e as fitas analisadas em um analisador de Holter Mars 8000 (Marquete). A potência espectral foi quantificada pela área em duas bandas de freqüência: 0,04-0,15 Hz – baixa freqüência (BF), 0,015-0,5 Hz – alta freqüência (AF). A razão BF/AF foi calculada em cada paciente. O mapa de retorno tridimensional foi construído através de um modelo matemático onde foram analisados os intervalos RR versus a diferença entre os intervalos RR adjacentes versus o número de contagens verificadas, e quantificado por três índices refletindo a modulação simpática (P1) e vagal (P2 e P3). DVP estava presente em 30 (36%) pacientes. Na análise univariada, pacientes com DVP apresentaram índices que refletem a modulação autonômica (análise espectral) diminuídos quando comparados aos pacientes sem DVP, respectivamente: BF = 0,19 ± 0,07 m/s2 vs. 0,29 ± 0,11 m/s2 P = 0,0001; BF/AF = 1,98 ± 0,9 m/s2 vs. 3,35 ± 1,83 m/s2 p = 0,001. Além disso, o índice que reflete a atividade simpática no mapa de retorno tridimensional (P1), foi mais baixo em pacientes com DVP (61,7 ± 9,4 vs. 66,8 ± 9,7 unidades arbitrárias, P = 0,04) durante a noite, refletindo maior ativação simpática neste período. Estes pacientes também apresentavam uma maior duração do diabetes (20 ± 8,1 vs. 15,3 ± 6,7 anos, P = 0,006), níveis de pressão arterial sistólica (154 ± 20 vs. 145 ± 20 mmHg, P = 0,04), razão cintura-quadril ( 0,98 ± 0,09 vs.0,92 ± 0,08, P = 0,01), e níveis de HbA1c mais elevados (7,7 ± 1,6 vs. 6,9 ± 1,7 %, P = 0,04), bem como valores de triglicerídeos ( 259 ± 94 vs. 230 ± 196 mg/dl, P= 0,03) e de excreção urinária de albumina ( 685,5 ± 1359,9 vs. 188,2 ± 591,1 μ/min, P = 0,02) superiores aos dos pacientes sem DVP.. Nos pacientes com DVP observou-se uma presença aumentada de nefropatia diabética (73,3% vs. 29,6% P = 0,0001), de retinopatia (73,3% vs. 44,4% P = 0,02) e neuropatia periférica (705 vs. 35,1% P = 0,006). Os grupos não diferiram quanto à idade, índice de massa corporal, tabagismo e presença de doença arterial coronariana. Na análise logística multivariada, a DVP permaneceu associada com a disfunção autonômica, mesmo após ter sido controlada pela pressão arterial sistólica, duração do DM, HbA1c, triglicerídeos e excreção urinária de albumina. Concluindo, pacientes com DVP e DM tipo 2 apresentam índices que refletem a modulação autonômica diminuídos, o que pode representar um fator de risco adicional para o aumento da mortalidade nestes pacientes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluate the distribution and variation of placental vascular indices according to gestational age and placental volume. From March to November 2007, three-dimensional (3D)-power Doppler ultrasound was performed in 295 normal pregnancies from 12 to 40 weeks of gestation. Using the same preestablished settings for all patients, power Doppler was applied to the placenta and placental Volume was obtained by the rotational technique (VOCAL(TM)). The 3D-power histogram was used to determine the placental vascular indices: vascularization index (VI), flow index (FI) and vascularization-flow index (VFI). The placental vascular indices were then plotted against gestational age and placental volume. All placental vascular indices showed constant distribution throughout gestation. A tendency for a reduction in placental vascular indices with increased placental volume was observed, but was only statistically significant when placental FI was considered (p < 0.05). All placental vascular indices estimated by 3D-power Doppler ultrasonography presented constant distribution throughout gestation, despite the increase in placental volume according to gestational age. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Doppler ultrasonography is a non-invasive real time pulse-wave technique recently used for the transrectal study of the reproductive system hemodynamics in large animals. This technic is based in the Doppler Effect Principle that proposes the change in frequency of a wave for an observer (red blood cells) moving relative to the source of the respective wave (ultrasonic transducer). This method had showed to be effective and useful for the evaluation of the in vivo equine reproductive tract increasing the diagnostic, monitoring, and predictive capabilities of theriogenology in mares. However, an accurate and truthful ultrasonic exam requires the previous knowledge of the Doppler ultrasonography principles. Review: In recent years, the capabilities of ultrasound flow imaging have increased enormously. The current Doppler ultrasound machines offer three methods of evaluation that may be used simultaneously (triplex mode). In B-mode ultrasound, a linear array of transducers simultaneously scans a plane through the tissue that can be viewed as a two-dimensional gray-scale image on screen. This mode is primarily used to identify anatomically a structure for its posterior evaluation using colored ultrasound modes (Color or Spectral modes). Colored ultrasound images of flow, whether Color or Spectral modes, are essentially obtained from measurements of moving red cells. In Color mode, velocity information is presented as a color coded overlay on top of a B-mode image, while Pulsed Wave Doppler provides a measure of the changing velocity throughout the cardiac cycle and the distribution of velocities in the sample volume represented by a spectral graphic. Color images conception varies according to the Doppler Frequency that is the difference between the frequency of received echoes by moving blood red cells and wave frequency transmitted by the transducer. To produce an adequate spectral graphic it is important determine the position and size of the simple gate. Furthermore, blood flow velocity measurement is influence by the intersection angle between ultrasonic pulses and the direction of moving blood-red cells (Doppler angle). Objectively colored ultrasound exam may be done on large arteries of the reproductive tract, as uterine and ovary arteries, or directly on the target tissue (follicle, for example). Mesovarium and mesometrium attachment arteries also can be used for spectral evaluation of the equine reproductive system. Subjectively analysis of the ovarian and uterine vascular perfusion must be done directly on the corpus luteum, follicular wall and uterus (endometrium and myometrium associated), respectively. Power-flow imaging has greater sensitivity to weak blood flow and independent of the Doppler angle, improving the evaluation of vessels with small diameters and slow blood flow. Conclusion: Doppler ultrasonography principles, methods of evaluation and reproductive system anatomy have been described. This knowledge is essential for the competent equipment acquisition and precise collection and analysis of colored ultrasound images. Otherwise, the reporting of inconsistent and not reproducible findings may result in the discredit of Doppler technology ahead of the scientific veterinary community.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: This study aimed to evaluate the characteristics of the brain and vascular indicesof the middle cerebral artery of canine foetuses. Methods: Twenty-five bitches were selected. Tissue development, echogenicity, echotexture and brain echobiometric data were studied, and the major structures were identified between the 5th and 8th gestational weeks. The area and volume of the brain mass (BMA and BMV), cranial area and volume (AC and VC), brain mass index (BMI) and brain volume index (BVI) were determined. A single ultrasound examination was performed during each studied week (6th, 7th and 8th). Doppler ultrasonography was performed to assess the maximum and minimum velocity, resistance and pulsatility index of middle cerebral artery of the foetuses. Results: Echoencephalography was performed to evaluate the morphological characteristics of the central nervous system. Cerebral echobiometry indicated an increase in area and volume of the hemispheres and cranium (P<0·001) but no changes in BMI or BVI over the gestational period studied. Doppler ultrasonography identified increases in peak systolic velocity (P=0·0188) and end diastolic velocity (P=0·0274) and decreases in resistance index (P=0·0002) and pulsatility index (P<0·001). Clinical Significance: Echoencephalography and spectral Doppler ultrasonography of the middle cerebral artery in canine foetuses might be a useful technique for prenatal care. © 2013 British Small Animal Veterinary Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Annually hundreds of crab-eating foxes (Cerdocyon thous) are referred to rehabilitation centers and zoos in Brazil. The ultrasonographic study of wildlife species is an important tool for a non-invasive and accurate anatomical description and provides important information for wildlife veterinary care. The aim of the present study was to determine the characteristics of the main abdominal organs as well as the vascular indexes of the abdominal aorta and renal arteries of crab-eating foxes (Cerdocyon thous) using mode B ultrasonography and Doppler ultrasonography, respectively. Ultrasonographic features of the main abdominal organs were described and slight differences were noticed between ultrasound imaging of abdominal organs of crab-eating foxes and other species. The bladder presented wall thickness of 12 +/- 0.01 mm, with three defined layers. Both, the right and left kidneys presented corticomedullary ratio of 1: 1 and similarly to the adrenals and the liver, they were homogeneous and hypoechoic compared to the spleen. The spleen was homogeneous and hyperechoic compared to the kidneys. The stomach presented 3 to 5 peristaltic movements per minute, wall thickness of 39 +/- 0.05 mm and lumen and mucosa with hyperechoic and hypoechoic features, respectively. Small and large intestines presented 2 to 3 peristaltic movements per minute, wall thickness of 34 +/- 0.03 mm and three defined layers with hyperechogenic (submucosa and serosa) and hypoechogenic (muscular) features. Ovaries of the female crab-eating fox were hypoechoic compared to the spleen and with heterogeneous parenchyma due to the presence of 2x2 mm ovarian follicles. Prostates of the six males were regular and with a well defined boundary, with a homogeneous and hyperechoic parenchyma compared to the spleen. Vascular indexes of the abdominal aorta (PSV: 25.60 +/- 0.32 cm/s; EDV: 6.96 +/- 1.68cm/s; PI: 1.15 +/- 0.07 e RI: 0.73 +/- 0.07) and right (PSV: 23.08 +/- 3.34cm/s; EDV: 9.33 +/- 2.36cm/s; PI: 1.01 +/- 0.65 e RI: 0.65 +/- 0.16) and left renal arteries (PSV: 23.74 +/- 3.94cm/s; EDV: 9.07 +/- 3.02cm/s; PI: 1.04 +/- 0.31 e RI: 0.64 +/- 0.10) were determined. Thus, conventional and Doppler ultrasonographic imaging provides basic information that can be used as reference for the species as well for other wild canids and it is a precise and non-invasive method that can be safely used to evaluate and diagnose abdominal injuries in these patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasonography (US) is an essential imaging tool for identifying abnormalities of the liver parenchyma, biliary tract and vascular system. US has replaced radiography as the initial imaging procedure in screening for liver disease in small animals. There are few reports of the use of conventional and helical computed tomography (CT) to assess canine or feline parenchymal and neoplastic liver disease and biliary disorders. In human medicine the development of multidetector- row helical computed tomography (MDCT), with its superior spatial and temporal resolution, has resulted in improved detection and characterization of diffuse and focal liver lesions. The increased availability of MDCT in veterinary practice provides incentive to develop MDCT protocols for liver imaging in small animals. The purpose of this study is to assess the rule of MDCT in the characterization of hepatobiliary diseases in small animals; and to compare this method with conventional US. Candidates for this prospective study were 175 consecutive patients (dogs and cats) referred for evaluation of hepatobiliary disease. The patients underwent liver US and MDCT. Percutaneous needle biopsy was performed on all liver lesions or alterations encountered. As for gallbladder, histopatological evaluation was obtained from cholecystectomy specimens. Ultrasonographic findings in this study agreed well with those of previous reports. A protocol for dual-phase liver MDCT in small animals has been described. MDCT findings in parenchymal disorders of the liver, hepatic neoplasia and biliary disorders are here first described in dogs and cats and compared with the corresponding features in human medicine. The ability of MDCT in detection and characterization of hepatobiliary diseases in small animals is overall superior to conventional US. Ultrasonography and MDCT scanning, however, play complementary rules in the evaluation of these diseases. Many conditions have distinctive imaging features that may permit diagnosis. In most instances biopsy is required for definitive diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Type--Therapy (case series) Level of Evidence 4. What's known on the subject? and What does the study add? Vasectomy reversal is often performed in general or neuraxial anaesthesia. Even though the site of vasectomy reversal is easily amenable to regional/local anaesthesia, spermatic cord blocks are rarely applied because of their risk of vascular damage within the spermatic cord. Recently, we described the technique of ultrasonography (US)-guided spermatic cord block for scrotal surgery, which, thanks to the US guidance, at the same time avoids the risk of vascular damage of blindly performed injections and the risks of general and neuraxial anaesthesia. Vasectomy reversal can easily be done in regional anaesthesia with the newly described technique of US-guided spermatic cord block without the risks of vascular damage by a blindly performed injection and the risks of standard general and neuraxial anaesthesia. In addition, this technique grants long-lasting postoperative pain relief and patients recover more quickly. Microsurgical conditions are excellent and patient satisfaction is high. Thanks to these advantages, more patients undergoing vasectomy reversal might avoid general or neuraxial anaesthesia.