994 resultados para ultrasound measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unpredicted difficult intubation can have severe consequences, and it is a significant source of morbidity and mortality. Although recent studies indicate that specific ultrasonography (US) measurements may be predictors of difficult laryngoscopy, their use is still limited, and its quantification is missing. The purpose of this prospective observational study is to evaluate the use of US-measured distance from skin to epiglottis (DSE) for difficult laryngoscopy prediction.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Quantitative ultrasound of bone is a promising method for bone assessment: radiation-free, portable and predictive of hip fracture. Its portability allowed us to study the relationships between ultrasonic parameters of bone with age and with non-vertebral fractures in elderly women living in 19 nursing homes. Broadband ultrasound attenuation (BUA) and speed of sound (SOS) of the calcaneus were measured (and the stiffness index calculated) in a sample of 270 institutionalized women, aged 85 +/- 7 years, using an Achilles bone densitometer (Lunar). The effects of age, history of non-vertebral and non-traumatic fractures, body mass index, triceps skinfold and arm circumference were assessed on BUA, SOS and stiffness index. Furthermore, to evaluate longitudinally the influence of aging on the ultrasound parameters of bone, 60 subjects from the same group had a second ultrasound measurement after 1 year. The cross-sectional analysis of the data on all 270 women showed a significant decrease (p < 0.001) with age in BUA, SOS and stiffness index (-0.47%, -0.06%, and -1.01% respectively per year). In the 94 women, (35%) with a history of previous non-vertebral fractures, ultrasound parameters were significantly lower (p < 0.0001) than in the 176 women with no history of fracture (-8.3% for BUA, -1.3% for SOS, -18.9% for stiffness index). In contrast, there was no significant difference in anthropometric measurements between the groups with and without previous non-vertebral fractures, although the measurements decreased significantly with age. In the longitudinal study, repeated quantitative ultrasound after 11.4 +/- 0.8 months showed no significant decrease in BUA (-1%) but a significant decrease in SOS (-0.3%, p < 0.0001) and in stiffness index (-3.6%, p < 0.0002). In conclusion, quantitative ultrasound of the calcaneus measures properties of bone which continue to decline in institutionalized elderly women, and is able to discriminate women with previous non-vertebral fractures.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

There are several filtration applications in the pulp and paper industry where the capacity and cost-effectiveness of processes are of importance. Ultrafiltration is used to clean process water. Ultrafiltration is a membrane process that separates a certain component or compound from a liquid stream. The pressure difference across the membrane sieves macromolecules smaller than 0.001-0.02 μm through the membrane. When optimizing the filtration process capacity, online information about the conditions of the membrane is needed. Fouling and compaction of the membrane both affect the capacity of the filtration process. In fouling a “cake” layer starts to build on the surface of the membrane. This layer blocks the molecules from sieving through the membrane thereby decreasing the yield of the process. In compaction of the membrane the structure is flattened out because of the high pressure applied. The higher pressure increases the capacity but may damage the structure of the membrane permanently. Information about the compaction is needed to effectively operate the filters. The objective of this study was to develop an accurate system for online monitoring of the condition of the membrane using ultrasound reflectometry. Measurements of ultrafiltration membrane compaction were made successfully utilizing ultrasound. The results were confirmed by permeate flux decline, measurements of compaction with a micrometer, mechanical compaction using a hydraulic piston and a scanning electron microscope (SEM). The scientific contribution of this thesis is to introduce a secondary ultrasound transducer to determine the speed of sound in the fluid used. The speed of sound is highly dependent on the temperature and pressure used in the filters. When the exact speed of sound is obtained by the reference transducer, the effect of temperature and pressure is eliminated. This speed is then used to calculate the distances with a higher accuracy. As the accuracy or the resolution of the ultrasound measurement is increased, the method can be applied to a higher amount of applications especially for processes where fouling layers are thinner because of smaller macromolecules. With the help of the transducer, membrane compaction of 13 μm was measured in the pressure of 5 bars. The results were verified with the permeate flux decline, which indicated that compaction had taken place. The measurements of compaction with a micrometer showed compaction of 23–26 μm. The results are in the same range and confirm the compaction. Mechanical compaction measurements were made using a hydraulic piston, and the result was the same 13 μm as obtained by applying the ultrasound time domain reflectometry (UTDR). A scanning electron microscope (SEM) was used to study the structure of the samples before and after the compaction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To evaluate the percutaneous Achilles tendon sectioning technique using a large gauge needle for the correction of residual equinus of congenital clubfoot treated with the Ponseti method. Methods: Fifty-seven Achilles tendon sections were prospectively evaluated in thirty-nine patients with clubfoot, treated with the Ponseti method between July 2005 and December 2008. The tenotomy was performed percutaneously with a large gauge needle. Ultrasound scan was performed immediately after the section, to ascertain whether the tenotomy was complete, as well as stump separation. Results: There was complete tendon section in all cases, but the need to perform the section maneuver more than once was common, due to the persistence of the residual strands between tendon stumps. The Thompson test and dynamic ultrasound evaluation were able to detect incomplete tenotomies. The mean ultrasound measurement of the tendon gap was 5.70 +/- 2.23 mm. Two patients had abnormal bleeding, which was controlled by digital pressure and did not compromise foot perfusion. Conclusion: Percutaneous Achilles tendon sectioning with a needle proved to be efficient and safe to correct residual equinus of clubfoot treated with the Ponseti technique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To compare measurements of the upper arm cross-sectional areas (total arm area,arm muscle area, and arm fat area of healthy neonates) as calculated using anthropometry with the values obtained by ultrasonography. Materials and methods: This study was performed on 60 consecutively born healthy neonates: gestational age (mean6SD) 39.661.2 weeks, birth weight 3287.16307.7 g, 27 males (45%) and 33 females (55%). Mid-arm circumference and tricipital skinfold thickness measurements were taken on the left upper mid-arm according to the conventional anthropometric method to calculate total arm area, arm muscle area and arm fat area. The ultrasound evaluation was performed at the same arm location using a Toshiba sonolayer SSA-250AÒ, which allows the calculation of the total arm area, arm muscle area and arm fat area by the number of pixels enclosed in the plotted areas. Statistical analysis: whenever appropriate, parametric and non-parametric tests were used in order to compare measurements of paired samples and of groups of samples. Results: No significant differences between males and females were found in any evaluated measurements, estimated either by anthropometry or by ultrasound. Also the median of total arm area did not differ significantly with either method (P50.337). Although there is evidence of concordance of the total arm area measurements (r50.68, 95% CI: 0.55–0.77) the two methods of measurement differed for arm muscle area and arm fat area. The estimated median of measurements by ultrasound for arm muscle area were significantly lower than those estimated by the anthropometric method, which differed by as much as 111% (P,0.001). The estimated median ultrasound measurement of the arm fat was higher than the anthropometric arm fat area by as much as 31% (P,0.001). Conclusion: Compared with ultrasound measurements using skinfold measurements and mid-arm circumference without further correction may lead to overestimation of the cross-sectional area of muscle and underestimation of the cross-sectional fat area. The correlation between the two methods could be interpreted as an indication for further search of correction factors in the equations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: 1. Identify differences in optic nerve sheath diameter (ONSD) as an indirect measure of intracranial pressure (ICP) in glaucoma patients and a healthy population. 2. Identify variables that may correlate with ONSD in primary open-angle glaucoma (POAG) and normal tension glaucoma (NTG) patients. METHODS: Patients with NTG (n = 46) and POAG (n = 61), and healthy controls (n = 42) underwent B-scan ultrasound measurement of ONSD by an observer masked to the patient diagnosis. Intraocular pressure (IOP) was measured in all groups, with additional central corneal thickness (CCT) and visual field defect measurements in glaucomatous patients. Only one eye per patient was selected. Kruskal-Wallis or Mann-Whitney were used to compare the different variables between the diagnostic groups. Spearman correlations were used to explore relationships among these variables. RESULTS: ONSD was not significantly different between healthy, NTG and POAG patients (6.09 ± 0.78, 6.03 ± 0.69, and 5.71 ± 0.83 respectively; p = 0.08). Visual field damage and CCT were not correlated with ONSD in either of the glaucoma groups (POAG, p = 0.31 and 0.44; NTG, p = 0.48 and 0.90 respectively). However, ONSD did correlate with IOP in NTG patients (r = 0.53, p < 0.001), while it did not in POAG patients and healthy controls (p = 0.86, p = 0.46 respectively). Patient's age did not relate to ONSD in any of the groups (p > 0.25 in all groups). CONCLUSIONS: Indirect measurements of ICP by ultrasound assessment of the ONSD may provide further insights into the retrolaminar pressure component in glaucoma. The correlation of ONSD with IOP solely in NTG patients suggests that the translaminar pressure gradient may be of particular importance in this type of glaucoma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Despite the apparent familial tendency toward abdominal aortic aneurysm (AAA) formation, the genetic causes and underlying molecular mechanisms are still undefined. In this study, we investigated the association between familial AAA (fAAA) and atherosclerosis. METHODS: Data were collected from a prospective database including AAA patients between 2004 and 2012 in the Erasmus University Medical Center, Rotterdam, The Netherlands. Family history was obtained by written questionnaire (93.1% response rate). Patients were classified as fAAA when at least one affected first-degree relative with an aortic aneurysm was reported. Patients without an affected first-degree relative were classified as sporadic AAA (spAAA). A standardized ultrasound measurement of the common carotid intima-media thickness (CIMT), a marker for generalized atherosclerosis, was routinely performed and patients' clinical characteristics (demographics, aneurysm characteristics, cardiovascular comorbidities and risk factors, and medication use) were recorded. Multivariable linear regression analyses were used to assess the mean adjusted difference in CIMT and multivariable logistic regression analysis was used to calculate associations of increased CIMT and clinical characteristics between fAAA and spAAA. RESULTS: A total of 461 AAA patients (85% men, mean age, 70 years) were included in the study; 103 patients (22.3%) were classified as fAAA and 358 patients (77.7%) as spAAA. The mean (standard deviation) CIMT in patients with fAAA was 0.89 (0.24) mm and 1.00 (0.29) mm in patients with spAAA (P = .001). Adjustment for clinical characteristics showed a mean difference in CIMT of 0.09 mm (95% confidence interval, 0.02-0.15; P = .011) between both groups. Increased CIMT, smoking, hypertension, and diabetes mellitus were all less associated with fAAA compared with spAAA. CONCLUSIONS: The current study shows a lower atherosclerotic burden, as reflected by a lower CIMT, in patients with fAAA compared with patients with spAAA, independent of common atherosclerotic risk factors. These results support the hypothesis that although atherosclerosis is a common underlying feature in patients with aneurysms, atherosclerosis is not the primary driving factor in the development of fAAA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ultrasound as a metrology tool has many applications in health care, industrial, and chemical analyses. Ultrasonic techniques are rapid, low-cost, non-invasive, and highly repeatable. Although ultrasound can be used to measure emulsions, no effort had been made thus far to optimize its sensitivity for metrological analysis. In this work, a technique for analyzing oil in water was validated. The wave velocity and attenuation were chosen as the ultrasonic parameters. The technique was implemented in the boundary region established by law for effluents from industrial plants involved with biofuel manufacturing. A technical effort of this study was to establish stable emulsions in concentrations close to the desired limit of study. The phase behaviours of pseudo-ternary oil, sodium chloride, and sodium lauryl sulphate were studied. The composition in the widest region of the diagram allowed for the formation of a stable emulsion, from which the ultrasound measurement was carried out. An analytical curve was obtained using ultrasonic attenuation to determine the content of oils and greases in wastewater ranging 15–240 ppm. The speed of sound did not appear to be an applicable parameter for this application. The technique was demonstrated to be an important alternative solution for the continuous monitoring of wastewater with regard to oil concentrations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Höyryvoimalaitoksen käyttöönotossa muodostuu kattilaputkien sisäpinnoille niitä korroosiolta suojaava ohut metallioksidikerros. Tämän kerroksen päälle kasvaa kattilan käytön aikana haitallista kerrostumaa paikallisen korroosion tai kattilavedessä olevien epäpuhtauksien kerääntymisen tai kiteytymisen seurauksena. Kerrostuma haittaa lämmönsiirtoa tulipesästä putkiseinämän läpi kattilaveteen. Putkien lämpötilan nousu suunniteltua korkeammaksi kasvattaa putkivaurioiden ja sisäpuolisen korroosion riskiä. Tästä johtuen paksuksi kasvaneet kerrostumat pyritään poistamaan happokäsittelyllä eli peittauksella ennen vaurioiden syntyä. Perinteisesti kerrostumapaksuus on määritetty kattilasta irrotetuista näyteputkista mikroskoopilla. Työn tavoitteena oli tutkia uudenlaisen ultraäänimittauksen teoriaa ja selvittää sen toimivuus höyrystinputkien kerrostumapaksuusmittauksissa. Lisäksi tavoitteena oli tutkia voimalaitoksen höyrystimen sisäpuolisten kerrostumien muodostumista ja niiden vaikutuksia sekä kattilan peittaustarpeen arviointia. Höyrystimen kerrostumien kasvunopeuteen vaikuttavat eniten voimalaitostyyppi, käytetty vesikemia ja kattilaveteen kulkeutuvien epäpuhtauksien määrä. Kasvunopeus vaihtelee laitosten välillä suuresti ja eroaa myös tulipesän eri kohdissa. Kattilaveden epäpuhtauspitoisuus ja kerrostumapaksuus vaikuttavat molemmat korroosiovaurioiden todennäköisyyteen. Peittauspaksuuden ohjearvoissa tulisi huomioida kattilan käyttöpaine, kattilatyyppi ja riski kattilaveden laadun heikkenemiselle. Putkinäytteistä ja laitoksilla suoritettujen mittauksien perusteella uusi ultraäänitekniikka tuottaa luotettavia tuloksia tavanomaisten kerrostumien mittauksessa. Vain yhdellä laitoksella esiintyi irtonaisen sakan kaltaista kerrostumaa, jota mittaus ei kyennyt havaitsemaan. Mittaustulokset kerrostumista tulipesän eri osissa antavat hyvän perustan peittaustarpeen arviointiin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La inducción del trabajo de parto ha demostrado aumentar simultáneamente las tasas de cesárea, especialmente en nulíparas con cérvix clínicamente desfavorables. Ya que la valoración clínica del cérvix es un método subjetivo, aunque ampliamente utilizado, el objetivo del presente estudio fue determinar la utilidad de la medición ecográfica de la longitud cervical comparándola con el puntaje de Bishop, en la predicción del éxito de la inducción del parto en las pacientes nulíparas en el servicio de Obstetricia del Hospital Universitario Clínica San Rafael, Bogotá. Materiales y métodos: Se realizó un estudio observacional, evaluando una cohorte prospectiva de 80 gestantes a quienes se les realizó valoración ultrasonográfica y clínica del cérvix antes de iniciar la inducción del trabajo de parto. Resultados: El análisis bivariado demostró que las pacientes con longitud cervical >20mm tienen 1.57 veces la probabilidad de tener parto por cesárea (RR 1.57 IC95% 1.03-2.39 p <0.05). De manera similar las pacientes con puntaje de Bishop 0 a 3 tienen 2.33 veces la probabilidad de tener parto por cesárea (RR 2.33 IC95% 1.28-4.23 p <0.05). La regresión logística binaria demostró que la edad materna y la longitud cervical fueron los únicos parámetros independientes con significancia estadística para predecir el éxito de la inducción. Conclusiones: La medición ecográfica de la longitud cervical tiene mayor utilidad que la valoración clínica del cérvix en la predicción del éxito de la inducción del parto en nulíparas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Steers were sorted into four groups based on hip height and fat cover at the start of the finishing period. Each group of sorted steers was fed diets containing 0.59 or 0.64 Mcal NEg per lb. of diet dry matter. Steers with less initial fat cover (0.08 in.) compared with those with more (0.17) had less carcass fat cover 103 days later. The steers with less fat cover accumulated fat at a faster rate, but this was not apparent prior to 80 days. Accretion of fat was best predicted by an exponential growth equation, and was not affected by the two concentrations of energy fed in this study. Steers with greater initial height accumulated fat cover at a slower rate than shorter steers. This difference was interpreted to mean that large-frame steers accumulate subcutaneous fat at a slower rate than medium-frame steers. Increase in area of the ribeye was best described by a linear equation. Initial fat cover, hip height, and concentrations of energy in the diet did not affect rate of growth of this muscle. Predicting carcass fat cover from the initial ultrasound measurement of fat thickness found 46 of the 51 carcasses with less than 0.4 in. of fat cover. Twelve carcasses predicted to have less than 0.4 in. of fat cover had more than 0.4 in. Five carcasses predicted to have more than 0.4 in. actually had less than that. Accurate initial measurements of initial fat thickness with ultrasound might be a useful measurement to sort cattle for specific marketing grids.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O HDL-c é um fator de risco cardiovascular negativo e sua concentração plasmática apresenta relação inversa com a incidência de eventos cardiovasculares. Entretanto, as evidências relativas ao grupo de indivíduos com níveis de HDL-c acima do percentil 95 da população geral ainda são escassas e o impacto da hiperalfalipoproteinemia (HALP) sobre o risco cardiovascular continua representando motivo de controvérsia na literatura médica. Alguns estudos em populações específicas associam a HALP a aumento do risco cardiovascular. Ao mesmo tempo, outros estudos identificaram populações de indivíduos hipoalfalipoproteinêmicos com marcada longevidade. Assim, demonstrou-se aparente dissociação entre níveis de HDL-c e risco cardiovascular em determinadas populações, reconduzível a aspectos disfuncionais da HDL. O objetivo do presente estudo foi verificar o papel da HALP na determinação do risco cardiovascular; comparar a prevalência de doença cardiovascular subclínica, avaliada por meio da quantificação ultrassonográfica da Espessura Íntimo-Medial Carotídea (EIMC), entre portadores de HDL-c >= 90mg/dL (grupo HALP) e portadores de concentrações de HDL-c atualmente consideradas normais (entre 40 e 50mg/dL para os homens e entre 50 e 60mg/dL para as mulheres); e avaliar características e função da HDL em portadores de HALP por meio do estudo de sua composição, de sua capacidade de efluxo de colesterol, e de sua atividade anti-inflamatória e antioxidante, correlacionando estas características com a presença de doença cardiovascular subclínica avaliada por meio da determinação da EIMC, da Velocidade de Onda de Pulso (VOP) e da presença de Calcificação Arterial Coronariana (CAC) avaliada pela TCMD. Para responder estas perguntas, o presente estudo foi articulado em dois braços: Braço 1: Análise da coorte do estudo ELSA com o objetivo de determinar a prevalência de HALP em uma população geral; definir o perfil demográfico, antropométrico e metabólico dos portadores de HALP; e comparar a prevalência de doença vascular subclínica deste grupo com controles da mesma coorte com níveis normais de HDL-colesterol. Braço 2: Recrutamento de 80 voluntários hígidos e portadores de HALP para avaliação da correlação entre presença de doença vascular subclínica, e aspectos estruturais e funcionais da HDL. Em seus dois braços, o estudo levou a quatro conclusões principais: 1) Níveis marcadamente elevados de HDL-c estão associados a menor espessura íntimo-medial carotídea quando comparados a níveis de HDL-c considerados normais pelas diretrizes vigentes. Embora portadores do fenótipo HALP apresentem, como grupo, um perfil metabólico mais favorável que o encontrado em indivíduos com HDL-c normal, a associação entre EIMC e HALP foi independente dos fatores de risco tradicionais, indicando que a menor prevalência destes últimos em portadores de HDL-c marcadamente elevado justifica apenas parcialmente a menor prevalência de doença vascular subclínica neste grupo; 2) Embora a HALP se apresente como um fenótipo ateroprotetor, há indivíduos com níveis marcadamente elevados de HDL-c que evoluem com doença cardiovascular, clínica ou subclínica. Neste contexto, nossos resultados indicam correlação entre os três métodos avaliados para estudar doença vascular subclínica em portadores de HALP: EIMC, VOP e CAC; 3) Os fatores de risco tradicionais continuam exercendo seu peso na determinação do risco cardiovascular em portadores de HALP. Idade, tabagismo, hipertensão arterial, hipertrigliceridemia e altos níveis de LDL-c apresentaram associação estatisticamente significativa com a presença de doença vascular subclínica no grupo estudado; 4) A avaliação da composição e da função da HDL em portadores de HALP pode permitir identificar indivíduos especificamente mais suscetíveis à aterosclerose. Nossos resultados indicam que, em particular, a atividade anti-inflamatória da HDL, avaliada pela capacidade de inibição da produção de IL-6; o efluxo de colesterol e a capacidade de transferência de triglicérides apresentaram associação independente com menor espessura íntimo-medial carotídea em portadores de HALP, enquanto níveis mais altos de Apo A-IV se associaram a maior grau de doença cardiovascular subclínica