969 resultados para ultrasonography, Doppler, duplex


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a 34-year-old patient with digital necrosis due to thromboangiitis obliterans. He was successfully treated with iloprost, a prostaglandin analogue. Duplex ultrasonography was performed during the perfusion of iloprost to optimize the doses and the treatment duration. A complete revascularization was observed after 10 days. Iloprost perfusions were stopped, and a slow regression of the necroses was observed in the subsequent days. With the use of duplex ultrasonography, unnecessary high doses of iloprost and long periods of treatment can be avoided reducing side effects and treatment costs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The superficial femoral vein (SFV) is a well-established alternative conduit for infra-inguinal reconstructivenous hypertension after SFV harvest may however result in significant morbidity. This study reports the efficiency of SFV as conduit for infra-inguinal reconstructions and characterize the anatomic and physiologic changes in harvest limbs and their relationship to the development of venous complications. METHODS: From May 1999 through November 2003, 23 SFV were harvested from 21 patients undergoing infra-inguinal reconstructions. Bypasses were controlled by regular duplex-ultrasound. The venous morbidity was assessed by measurements of leg circumferences, strain-gauge plethysmography and quality of life, investigated by the VEINES-QOL scale. RESULTS: At a mean follow-up of 10.4 months (range 1-56), primary, secondary patency and limb salvage rates of infra-inguinal bypasses using SFV are 71.4%, 76.2% and 85.7% respectively. No patient had major venous claudication. Oedema was significantly present in nine patients. Strain-gauge plethysmography showed outflow obstruction in all patients. The VEINES-QOL assessment showed no limitation in social and domestic activity, moderate complain about leg heaviness despite presence of oedema. CONCLUSION: The SFV harvest is a reliable conduit for infra-inguinal reconstructions and results in moderate venous morbidity in terms of functional consequences and quality of life.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The study aims to assess the feasibility and midterm outcome of trans-peritoneal laparoscopy for coeliac artery compression syndrome (CACS).Design: Retrospective chart review involving four European vascular surgery departments and two surgical teams.Materials and methods: charts for patients who underwent laparoscopy for symptomatic CACS between December 2003 and November 2009 were reviewed. Preoperative computed tomography (CT) angiography and postoperative duplex scan and/or CT angiography were performed.Results: Eleven consecutive patients (nine women) with a median age of 52 years (interquartile range: 42.5-59 years) underwent trans-peritoneal laparoscopy for CACS. All patients had a history of postprandial abdominal pain; weight loss exceeded 10% of the body mass in eight cases. Preoperative CT angiography revealed coeliac trunk stenosis >70% in all cases. One patient had additional aortitis and inferior mesenteric artery occlusion, while another patient presented with an occluded superior mesenteric artery. Two conversions occurred (one difficult dissection and one aorto-hepatic bypass needed for incomplete release of CACS). The median blood loss was 195 ml (range: 50-900 ml) and median operative time was 80 min (interquartile range: 65-162.5 years). Symptoms improved immediately in 10/11 patients (no residual stenosis) while one remained unchanged despite a residual stenosis treated by a percutaneous angioplasty. Symptoms reappeared in one patient due to coeliac axis occlusion. The mean follow-up period was 35 +/- 23 months (range: 12-78 months).Conclusion: Our study demonstrates that trans-peritoneal laparoscopy for treating median arcuate ligament syndrome is safe and feasible. Additional patients and a longer follow-up are needed for long-term assessment of this laparoscopic technique. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: Chronic critical limb ischemia (CLI) often requires venous bypass grafting to distal arterial segments. However, graft patency is influenced by the length and quality of the graft and occasionally patients may have limited suitable veins. We investigated short distal bypass grafting from the superficial femoral or popliteal artery to the infrapopliteal, ankle or foot arteries, despite angiographic alterations of inflow vessels, providing that invasive pressure measurement at the site of the planned proximal anastomosis revealed an inflow-brachial pressure difference of <or=10 mmHg. METHODS: Four hundred and twenty-three consecutive infrainguinal bypass grafts were performed for CLI between June, 1999 and November, 2002 at our institution. All patients underwent preoperative clinical examination, arteriography and assessment of the veins by duplex ultrasound. The study group are patients in whom the proximal and distal anastomoses of the bypass are below the femoral bifurcation and the popliteal artery, respectively. Invasive arterial pressure measurements were recorded at the level of the planned proximal anastomosis which was performed at that level if the difference of the inflow-brachial pressure was <or=10 mmHg, irrespective of angiographic alterations of the inflow vessels proximal to the planned anastomosis. All patients had a clinical follow-up included a duplex examination of their graft, at 1 week, 3, 9 and 12 months and, thereafter, annually. No patient was lost to follow-up. RESULTS: Sixty-seven patients underwent 71 short distal bypass grafts in 71 limbs with reversed saphenous vein grafts in 52, in situ saphenous veins in 11, reversed cephalic vein in 1 and composite veins in 7, respectively. Surgical or endovascular interventions to improve inflow were required in 4 limbs (5.6%). The mean follow-up time was 22.5 months and the two-year survival was 92.5%. Primary and secondary patency rates at 2 years were 73% and 93%, respectively, and the limb salvage rate was 98.5%. CONCLUSION: In appropriately selected patients, short distal venous bypass grafts can be performed with satisfactory patency and limb salvage rates even in the presence of morphologic alterations of the inflow vessels providing that these are not hemodynamically significant, or can be corrected intraoperatively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: We report a new salvage technique for treating venous aneurysms (VAs) complicating vascular access arteriovenous fistula (AVF) using externally reinforced venous aneurysmorrhaphy. DESIGN: A retrospective study over a 20-month period from a single centre. PATIENTS: Patients presenting to the vascular surgery department, Bordeaux University Hospital for revision of a vascular access AVF were included. METHODS: Reinforced venous aneurysmorrhaphy consisted in removal of redundant vessel wall followed by reinforcement using an external prosthetic graft. Patency, diameter and flow were assessed by duplex ultrasound at 1, 6 and 12 months after salvage. RESULTS: Thirty-eight eligible patients were identified. Five were excluded because VA was associated with central vein stenosis; the remaining 33 underwent salvage. Indications were rapidly expanding or painful VA in seven cases; VA with frequent bleeding or damaged overlying skin in eight; VA in close relation to a stenosis in two; and VA associated with high-flow rate in 16. Cannulation was attempted after 30 days. Mean follow-up time was 12 S.D. 5 months (range: 4-22). Two repaired AVFs failed. Primary 1-year patency was 93%. No aneurysm or infection occurred. Reduction of high flow was successful in 12 of 16 patients. The remaining four required re-operation. CONCLUSIONS: Reinforced venous aneurysmorrhaphy is effective in controlling venous dilation and achieving patency. Reduction of high-flow rates was not always achieved. Further study is needed to evaluate long-term efficacy of this treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Determine if arm veins are good conduits for infrainguinal revascularisation and should be used when good quality saphenous vein is not available. DESIGN: Retrospective study. MATERIALS AND METHODS: We evaluated a consecutive series of infrainguinal bypass (IB) using arm vein conduits from March 2001 to December 2006.We selected arm vein by preoperative ultrasound mapping to identify suitable veins. We measured vein diameter and assessed vein wall quality. We followed patients with systematic duplex imaging at 1 week, 1, 3, 6 and 12 months, and annually thereafter. We treated significative stenoses found during the follow-up. RESULTS: We performed 56 infrainguinal revascularisation using arm vein conduits in 56 patients. Primary patency rates at 1, 2 and 3 years were 65%, 51% and 47%. Primary assisted patencies at 1, 2 and 3 years were 96%, 96% and 82%. Secondary patency rates at 1, 2 and 3 years were 92%, 88% and 88%. The three-year limb salvage rate was 88%. CONCLUSIONS: We conclude that infrainguinal bypass using arm vein for conduits gives good patency rates, if selected by a preoperative US mapping to use the best autogenous conduit available.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Long occlusions in calcified crural arteries are a major cause of endovascular technical failure in patients with critical limb ischaemia. Therefore, distal bypasses are mainly performed in patients with heavily calcified arteries and with consequently delicate clamping. A new reverse thermosensitive polymer (RTP) is an alternative option to occlude target vessels. The aim of the study is to report our technical experience with RTP and to assess its safety and efficiency to temporarily occlude small calcified arteries during anastomosis time. METHODS: Between July 2010 and December 2011, we used RTP to occlude crural arteries in 20 consecutive patients with 20 venous distal bypasses. We recorded several operative parameters, such as volume of injected RTP, duration of occlusion and anastomotic time. Quality of occlusion was subjectively evaluated. Routine on-table angiography was performed to search for plug emboli. Primary patency, limb salvage and survival rates were reported at 6 months. RESULTS: In all patients, crural artery occlusion was achieved with the RTP without the use of an adjunct occlusion device. Mean volume of RTP used was 0.3 ml proximally and 0.25 ml distally. Mean duration of occlusion was 14.4 ± 4.5 min, while completion of the distal anastomosis lasted 13.4 ± 4.3 min. Quality of occlusion was judged as excellent in eight cases and good in 12 cases. Residual plugs were observed in two patients and removed with an embolectomy catheter, before we amended the technique for dissolution of RTP. At 6 months, primary patency rate was 75% but limb salvage rate was 87.5%. The 30-day mortality rate was 10%. CONCLUSIONS: This study shows that RTP is safe when properly dissolved and effective to occlude small calcified arteries for completion of distal anastomosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper aims to describe the uterine and ovarian ultrasonographic characteristics and Doppler velocimetric features of their arteries in bitches during the periovulatory period. Fifteen estrous cycles in 10 animals were evaluated. The ultrasonographic characteristics, resistance indices (RI) and pulsatility indices (PI) of the uterus and ovaries in each animal were recorded 5 days before and after ovulation (D0). The data were statistically analyzed, and the results were expressed as the mean ± standard error of mean (P<0.05). In results the ultrasonographic features of the uterus were the same on all of the cycles and evaluated days. The uterus had an average diameter of 0.85±0.02cm. An increase in the volume of the ovaries and the diameter of the ovarian follicles were measured. Ovaries had a volume of 0.64±0.06cm³, and the follicles cavities had a diameter of 0.46 ± 0.01 cm on the day of ovulation. After ovulation, it was observed that some follicles not collapse in some cycles. Two days prior to ovulation, the uterine blood perfusion decreased. This decrease remained unchanged until ovulation. Following ovulation, we measured a gradual increase in the uterine perfusion and in the ovarian artery. This artery directed blood flow to the ovaries and increased the intra-ovarian perfusion on the day after ovulation. In conclusion, specific features are observed in the uterus and ovarian ultrasound image and Doppler values of their arteries presented on the periovulatory days and when associated allow to estimate more accurately the date of ovulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: Annually hundreds of crab-eating foxes (Cerdocyon thous) are referred to rehabilitation centers and zoos in Brazil. The ultrasonographic study of wildlife species is an important tool for a non-invasive and accurate anatomical description and provides important information for wildlife veterinary care. The aim of the present study was to determine the characteristics of the main abdominal organs as well as the vascular indexes of the abdominal aorta and renal arteries of crab-eating foxes (Cerdocyon thous) using mode B ultrasonography and Doppler ultrasonography, respectively. Ultrasonographic features of the main abdominal organs were described and slight differences were noticed between ultrasound imaging of abdominal organs of crab-eating foxes and other species. The bladder presented wall thickness of 12±0.01mm, with three defined layers. Both, the right and left kidneys presented corticomedullary ratio of 1:1 and similarly to the adrenals and the liver, they were homogeneous and hypoechoic compared to the spleen. The spleen was homogeneous and hyperechoic compared to the kidneys. The stomach presented 3 to 5 peristaltic movements per minute, wall thickness of 39±0.05mm and lumen and mucosa with hyperechoic and hypoechoic features, respectively. Small and large intestines presented 2 to 3 peristaltic movements per minute, wall thickness of 34±0.03mm and three defined layers with hyperechogenic (submucosa and serosa) and hypoechogenic (muscular) features. Ovaries of the female crab-eating fox were hypoechoic compared to the spleen and with heterogeneous parenchyma due to the presence of 2x2mm ovarian follicles. Prostates of the six males were regular and with a well defined boundary, with a homogeneous and hyperechoic parenchyma compared to the spleen. Vascular indexes of the abdominal aorta (PSV: 25.60±0.32cm/s; EDV: 6.96±1.68cm/s; PI: 1.15±0.07 e RI: 0.73±0.07) and right (PSV: 23.08±3.34cm/s; EDV: 9.33±2.36cm/s; PI: 1.01±0.65 e RI: 0.65±0.16) and left renal arteries (PSV: 23.74±3.94cm/s; EDV: 9.07±3.02cm/s; PI: 1.04±0.31 e RI: 0.64±0.10) were determined. Thus, conventional and Doppler ultrasonographic imaging provides basic information that can be used as reference for the species as well for other wild canids and it is a precise and non-invasive method that can be safely used to evaluate and diagnose abdominal injuries in these patients.