999 resultados para turbidity measurements


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new microtiter-plate dilution method was applied during the expedition ANTARKTIS-XI/2 with RV Polarstern to determine the distribution of copiotrophic and oligotrophic bacteria in the water columns at polar fronts. Twofold serial dilutions were performed with an eight-channel Electrapette in 96-wells plates by mixing 150 µl of seawater with 150 µl of copiotrophic or olitrophic Trypticase-Broth, three times per well. After incubation of about 6 month at 2 °C, turbidities were measured with an eight-channel photometer at 405 nm and combinations of positive test results for three consecutive dilutions chosen and compared with a Most Probable Number table, calculated for 8 replicates and twofold serial dilutions. Densities of 12 to 661 cells/ml for copiotrophs, and 1 to 39 cells/ml for oligotrophs were found. Colony Forming Units on copiotrophic Trypticase-Agar were between 6 and 847 cells/ml, which is in the same range as determined with the MPN method.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A three day workshop on turbidity measurements was held at the Hawaii Institute of Marine Biology from August 3 1 to September 2, 2005. The workshop was attended by 30 participants from industry, coastal management agencies, and academic institutions. All groups recognized common issues regarding the definition of turbidity, limitations of consistent calibration, and the large variety of instrumentation that nominally measure "turbidity." The major recommendations, in order of importance for the coastal monitoring community are listed below: 1. The community of users in coastal ecosystems should tighten instrument design configurations to minimize inter-instrument variability, choosing a set of specifications that are best suited for coastal waters. The IS0 7027 design standard is not tight enough. Advice on these design criteria should be solicited through the ASTM as well as Federal and State regulatory agencies representing the majority of turbidity sensor end users. Parties interested in making turbidity measurements in coastal waters should develop design specifications for these water types rather than relying on design standards made for the analysis of drinking water. 2. The coastal observing groups should assemble a community database relating output of specific sensors to different environmental parameters, so that the entire community of users can benefit from shared information. This would include an unbiased, parallel study of different turbidity sensors, employing a variety of designs and configuration in the broadest range of coastal environments. 3. Turbidity should be used as a measure of relative change in water quality rather than an absolute measure of water quality. Thus, this is a recommendation for managers to develop their own local calibrations. See next recommendation. 4. If the end user specifically wants to use a turbidity sensor to measure a specific water quality parameter such as suspended particle concentration, then direct measurement of that water quality parameter is necessary to correlate with 'turbidity1 for a particular environment. These correlations, however, will be specific to the environment in which they are measured. This works because there are many environments in which water composition is relatively stable but varies in magnitude or concentration. (pdf contains 22 pages)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

As part of a larger experiment, atmospheric turbidity measurements were carried out during the austral summer 1985/86 in Adelie Land, Eastern Antarctica at 1560 m elevation. A comparison of our measurements of the solar beam with those of other areas in the Arctic and Antarctic was carried out. Our values were higher than all measurements from the Arctic. For Antarctica, Plateau and Mizuho Stations, both higher in altitude, had somewhat higher values, while the value of the coastal stations were lower. We calculated also turbidity indexes such as Unke's turbidity factor T and Angstrom's turbidity coefficient ß. Mean values of T were around 2.0, which are low values indeed. Beta values were around 0.04, a rather typical value for polar regions. No trend in turbidity could be observed for the time of observation. Further, it could be shown that the decrease in intensity with increasing optical air mass was less pronounced for larger wavelengths than for shorter ones.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The export of sediments from coastal catchments can have detrimental impacts on estuaries and near shore reef ecosystems such as the Great Barrier Reef. Catchment management approaches aimed at reducing sediment loads require monitoring to evaluate their effectiveness in reducing loads over time. However, load estimation is not a trivial task due to the complex behaviour of constituents in natural streams, the variability of water flows and often a limited amount of data. Regression is commonly used for load estimation and provides a fundamental tool for trend estimation by standardising the other time specific covariates such as flow. This study investigates whether load estimates and resultant power to detect trends can be enhanced by (i) modelling the error structure so that temporal correlation can be better quantified, (ii) making use of predictive variables, and (iii) by identifying an efficient and feasible sampling strategy that may be used to reduce sampling error. To achieve this, we propose a new regression model that includes an innovative compounding errors model structure and uses two additional predictive variables (average discounted flow and turbidity). By combining this modelling approach with a new, regularly optimised, sampling strategy, which adds uniformity to the event sampling strategy, the predictive power was increased to 90%. Using the enhanced regression model proposed here, it was possible to detect a trend of 20% over 20 years. This result is in stark contrast to previous conclusions presented in the literature. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Poly(ether imine) dendritic macromolecules were undertaken to study the reversible dendrimer monomer-megamer assembly-disassembly in aqueous solutions. Synthesis of thiol functionalized poly(ether imine) (PETIM) dendrimers and their covalent aggregation behavior in the aqueous solution of ethanol/water (2:1) is demonstrated. The dendritic megamers were characterized using microscopic techniques. Kinetics of the aggregation behavior was followed using turbidity measurements, light-scattering and atomic force microscopic techniques. Inherent luminescence behavior of PETIM dendrimer monomers was retained in the dendrimer megamers also, which allowed visualization of the megamers through confocal microscopy. Extent of thiol functionalities that remained after the megamer assembly was estimated through Ellman's assay. Subsequent to megamer assembly, disassembly of megamers to dendrimer monomers was conducted, using dithiothreitol reagent. Water-insoluble sudan I dye was encapsulated in dendrimer megamer and subsequent release profile was assessed during the disassembly in aqueous solutions. The studies were conducted using first, second and third generations, representing 4, 8 and 16 sulfhydryl groups at their peripheries of dendrimers, respectively. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present an improved procedure on the approach to determine the stability of polystyrene spheres at microscopic particle levels by means of artificially induced particle collisions with the aid of optical tweezers [J.Chem.Phys. 119, 2399(2003)]. The basic consideration on this new development is that the major contribution to the sticking probability for a particle pair caught into the optical trap for a short period is from its single collision; therefore, if the trapping duration for the pair is taken to be short, the accumulated sticking probability will be a good approximation for the single collision. The experimental procedure associated with this approximation does not resort to exactly controlling the short trapping duration or request the trapping duration correction as previously reported and therefore it is more practical and applicable for broader range of the stability ratio. The experimental results under different electrolyte concentrations by the new procedure are consistent with those from the turbidity measurements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A comprehensive study was made of the flocculation of dispersed E. coli bacterial cells by the cationic polymer polyethyleneimine (PEI). The three objectives of this study were to determine the primary mechanism involved in the flocculation of a colloid with an oppositely charged polymer, to determine quantitative correlations between four commonly-used measurements of the extent of flocculation, and to record the effect of varying selected system parameters on the degree of flocculation. The quantitative relationships derived for the four measurements of the extent of flocculation should be of direct assistance to the sanitary engineer in evaluating the effectiveness of specific coagulation processes.

A review of prior statistical mechanical treatments of absorbed polymer configuration revealed that at low degrees of surface site coverage, an oppositely- charged polymer molecule is strongly adsorbed to the colloidal surface, with only short loops or end sequences extending into the solution phase. Even for high molecular weight PEI species, these extensions from the surface are theorized to be less than 50 Å in length. Although the radii of gyration of the five PEI species investigated were found to be large enough to form interparticle bridges, the low surface site coverage at optimum flocculation doses indicates that the predominant mechanism of flocculation is adsorption coagulation.

The effectiveness of the high-molecular weight PEI species 1n producing rapid flocculation at small doses is attributed to the formation of a charge mosaic on the oppositely-charged E. coli surfaces. The large adsorbed PEI molecules not only neutralize the surface charge at the adsorption sites, but also cause charge reversal with excess cationic segments. The alignment of these positive surface patches with negative patches on approaching cells results in strong electrostatic attraction in addition to a reduction of the double-layer interaction energies. The comparative ineffectiveness of low-molecular weight PEI species in producing E. coli flocculation is caused by the size of the individual molecules, which is insufficient to both neutralize and reverse the negative E.coli surface charge. Consequently, coagulation produced by low molecular weight species is attributed solely to the reduction of double-layer interaction energies via adsorption.

Electrophoretic mobility experiments supported the above conclusions, since only the high-molecular weight species were able to reverse the mobility of the E. coli cells. In addition, electron microscope examination of the seam of agglutination between E. coli cells flocculation by PEI revealed tightly- bound cells, with intercellular separation distances of less than 100-200 Å in most instances. This intercellular separation is partially due to cell shrinkage in preparation of the electron micrographs.

The extent of flocculation was measured as a function of PEl molecular weight, PEl dose, and the intensity of reactor chamber mixing. Neither the intensity of mixing, within the common treatment practice limits, nor the time of mixing for up to four hours appeared to play any significant role in either the size or number of E.coli aggregates formed. The extent of flocculation was highly molecular weight dependent: the high-molecular-weight PEl species produce the larger aggregates, the greater turbidity reductions, and the higher filtration flow rates. The PEl dose required for optimum flocculation decreased as the species molecular weight increased. At large doses of high-molecular-weight species, redispersion of the macroflocs occurred, caused by excess adsorption of cationic molecules. The excess adsorption reversed the surface charge on the E.coli cells, as recorded by electrophoretic mobility measurements.

Successful quantitative comparisons were made between changes in suspension turbidity with flocculation and corresponding changes in aggregate size distribution. E. coli aggregates were treated as coalesced spheres, with Mie scattering coefficients determined for spheres in the anomalous diffraction regime. Good quantitative comparisons were also found to exist between the reduction in refiltration time and the reduction of the total colloid surface area caused by flocculation. As with turbidity measurements, a coalesced sphere model was used since the equivalent spherical volume is the only information available from the Coulter particle counter. However, the coalesced sphere model was not applicable to electrophoretic mobility measurements. The aggregates produced at each PEl dose moved at approximately the same vlocity, almost independently of particle size.

PEl was found to be an effective flocculant of E. coli cells at weight ratios of 1 mg PEl: 100 mg E. coli. While PEl itself is toxic to E.coli at these levels, similar cationic polymers could be effectively applied to water and wastewater treatment facilities to enhance sedimentation and filtration characteristics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A series of novel temperature- and pH-responsive graft copolymers, poly(L-glutamic acid)-g-poly(N-isopropylacrylamide), were synthesized by coupling amino-semitelechelic poly(N-isopropylacrylamide) with N-hydroxysuccinimide-activated poly(L-glutamic acid). The graft copolymers and their precursors were characterized, by ESI-FTICR Mass Spectrum, intrinsic viscosity measurements and proton nuclear magnetic resonance (H-1 NMR). The phase-transition and aggregation behaviors of the graft copolymers in aqueous solutions were investigated by the turbidity measurements and dynamic laser scattering.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The experimental data of phase diagrams for both polyethylene oxide/poly(ethylene oxide-b-dimethylsiloxane) binary and toluene/polyethylene oxide/poly(ethylene oxide-b-dimethylsiloxane) ternary polymer-containing systems was obtained at atmosphere pressure by light scattering method. The critical points for some pre-selected compositions and the pressure effect on the phase transition behavior of ternary system were investigated by turbidity measurements. The chosen system is a mixture of ternary which is one of the very few abnormal polymer-containing systems exhibiting pressure-induced both miscibility and immiscibility. This unusual behavior is related to the toluene concentration in the mixtures. The effect of toluene on the phase transition behavior of the ternary polymer-containing mixture was traced. Such behavior can make it possible to process composite materials from incompatible polymers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cloud-point temperatures (T-cl's) of poly(ethylene oxide) (PEO) and poly(ethylene oxide)-block-polydimethylsiloxane (P(EO-b-DMS)) homopolymer and block-oligomer mixtures were determined by turbidity measurements over a range of temperatures (105 to 130degrees), pressures (1 to 800 bar), and compositions (10-40 wt.-% PEO). The system phase separates upon cooling and T-cl was found to decrease with an increase in pressure for a constant composition. In the absence of special effects, this finding indicates negative excess volumes. Special attention was paid to the demixing temperatures as a function of the pressure for the different polymer mixtures and the plots in the T-phi plane (where phi signifies volume fractions). The cloud-point curves of the polymer mixture under pressures were observed for different compositions. The Sanchez-Lacombe (SL) lattice fluid theory was used to calculate the spinodals, the binodals, the Flory-Huggins (FH) interaction parameter, the enthalphy of mixing, and the volume changes of mixing. The calculated results show that modified P(EO-b-DMS) scaling parameters with the new combining rules can describe the thermodynamics of the PEO/P(EO-b-DMS) system well with the SL theory.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thesis submitted to Faculdade de Ciências e Tecnologia from Universidade Nova de Lisboa in partial fulfillment of the requirements for the obtention of the degree of Master of Science in Biotechnology

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Durant les dernières décennies, la technique Langmuir-Blodgett (LB) s’est beaucoup développée dans l’approche « bottom-up » pour la création de couches ultra minces nanostructurées. Des patrons constitués de stries parallèles d’environ 100 à 200 nm de largeur ont été générés avec la technique de déposition LB de monocouches mixtes de 1,2-dilauroyl-sn-glycéro-3-phosphatidylcholine (DLPC) et de 1,2-dipalmitoyl-sn-glycéro-3-phosphatidylcholine (DPPC) sur des substrats de silicium et de mica. Afin d’amplifier la fonctionnalité de ces patrons, la 1-palmitoyl-2-(16-(S-methyldithio)hexadécanoyl)-sn-glycéro-3-phosphatidylcholine (DSDPPC) et la 1-lauroyl-2-(12-(S-methyldithio)dodédecanoyl)-sn-glycéro-3-phosphatidylcholine (DSDLPC) ont été employées pour la préparation de monocouches chimiquement hétérogènes. Ces analogues de phospholipide possèdent un groupement fonctionnel méthyldisulfide qui est attaché à la fin de l’une des chaînes alkyles. Une étude exhaustive sur la structure de la phase des monocouches Langmuir, Langmuir-Schaefer (LS) et LB de la DSDPPC et de la DSDLPC et leurs différents mélanges avec la DPPC ou la DLPC est présentée dans cette thèse. Tout d’abord, un contrôle limité de la périodicité et de la taille des motifs des stries parallèles de DPPC/DLPC a été obtenu en variant la composition lipidique, la pression de surface et la vitesse de déposition. Dans un mélange binaire de fraction molaire plus grande de lipide condensé que de lipide étendu, une vitesse de déposition plus lente et une plus basse pression de surface ont généré des stries plus continues et larges. L’addition d’un tensioactif, le cholestérol, au mélange binaire équimolaire de la DPPC/DLPC a permis la formation de stries parallèles à de plus hautes pressions de surface. La caractérisation des propriétés physiques des analogues de phospholipides a été nécessaire. La température de transition de phase de la DSDPPC de 44.5 ± 1.5 °C comparativement à 41.5 ± 0.3 °C pour la DPPC. L’isotherme de la DSDPPC est semblable à celui de la DPPC. La monocouche subit une transition de phase liquide-étendue-à-condensée (LE-C) à une pression de surface légèrement supérieure à celle de la DPPC (6 mN m-1 vs. 4 mN m-1) Tout comme la DLPC, la DSDLPC demeure dans la phase LE jusqu’à la rupture de la monocouche. Ces analogues de phospholipide existent dans un état plus étendu tout au long de la compression de la monocouche et montrent des pressions de surface de rupture plus basses que les phospholipides non-modifiés. La morphologie des domaines de monocouches Langmuir de la DPPC et de la DSDPPC à l’interface eau/air a été comparée par la microscopie à angle de Brewster (BAM). La DPPC forme une monocouche homogène à une pression de surface (π) > 10 mN/m, alors que des domaines en forme de fleurs sont formés dans la monocouche de DSDPPC jusqu’à une π ~ 30 mN m-1. La caractérisation de monocouches sur substrat solide a permis de démontrer que le patron de stries parallèles préalablement obtenu avec la DPPC/DLPC était reproduit en utilisant des mélanges de la DSDPPC/DLPC ou de la DPPC/DSDLPC donnant ainsi lieu à des patrons chimiquement hétérogènes. En général, pour obtenir le même état de phase que la DPPC, la monocouche de DSDPPC doit être comprimée à de plus hautes pressions de surface. Le groupement disulfide de ces analogues de phospholipide a été exploité, afin de (i) former des monocouches auto-assemblées sur l’or et de (ii) démontrer la métallisation sélective des terminaisons fonctionnalisées des stries. La spectrométrie de photoélectrons induits par rayons X (XPS) a confirmé que la monocouche modifiée réagit avec la vapeur d’or pour former des thiolates d’or. L’adsorption de l’Au, de l’Ag et du Cu thermiquement évaporé démontre une adsorption préférentielle de la vapeur de métal sur la phase fonctionnalisée de disulfide seulement à des recouvrements sub-monocouche.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of the present study was to investigate the effect of chlorhexidine at subinhibitory concentration (50% minimal inhibitory concentration (MIC)) on the growth, cytolysin expression and phagocytosis of Streptococcus agalactiae ATCC 13813. Bacterial growth with and without chlorhexidine treatment was monitored by turbidity measurements, and exocytolysins were estimated by neutral red uptake assay by the McCoy cell line. The phagocytic process was evaluated using luminol-enhanced chemiluminescence to follow the respiratory burst of polymorphonuclear neutrophils exposed to bacteria. Chlorhexidine-treated culture did not exhibit a detectable decrease in cell growth, and no statistically significant reduction in the respiratory burst of polymorphonuclear neutrophils was observed. However, growth in the presence of chlorhexidine resulted in a significant reduction of S. agalactiae exocytolysins. Although 50% MIC of chlorhexidine did not interfere with S. agalactiae growth and phagocytosis, the knowledge that this concentration was still able to alter some bacterial virulence parameters may be useful in its therapeutic applications. (c) 2006 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die Forschung im Bereich der Drug Delivery-Systeme konzentriert sich auf biokompatible und wenig immunogene Trägermoleküle. Eine Klasse vielversprechender Trägersysteme stellen Peptid basierte Polymere dar, die neben einer hohen Biokompatibilität auch eine Sensitivität gegenüber externen Einflüssen aufweisen. Der zwitterionische Charakter von Aminosäuren und Peptiden verhindert die Adsorption von Serumproteinen und ein „antifouling“ Verhalten kann festgestellt werden, sodass diese Moleküle für den Einsatz als Wirkstoffträgersystem sehr geeignet scheinen. In Kombination mit einer bürstenartigen Struktur entstehen Systeme mit einer einzigartigen Peptidarchitektur, die sich durch eine hohe Dichte funktioneller Gruppen für Konjugationsreaktionen auszeichnen und deren formabhängige Zellaufnahme sie besonders attraktiv für die Anwendung als „Nanocarrier“ macht.rnrnDas zwitterionische Poly-(ε-N-Methacryloyl-L-Lysin) (Mw = 721,000 g∙mol 1) wurde durch freie radikalische Polymerisation dargestellt und seine Konformation in Abhängigkeit von Ionenstärke und pH-Wert untersucht. Die Biokompatibilität des Systems konnte durch Toxizitätstests und dynamische Lichtstreuung in humanem Blutserum nachgewiesen werden. Zusammen mit der vernachlässigbaren unspezifischen Aufnahme in dendritische Zellen aus Knochenmark erfüllt das System damit alle Bedingungen, die an ein polymeres Wirkstoffträgersystem gestellt werden. Darüber hinaus können Komplexe des Polymers mit DNA in Gegenwart von divalenten Metallionen für die Gentransfektion verwendet werden.rnrnDurch Kopplung von ε-N-Methacryloyl-L-Lysin mit der Elastin-ähnlichen Polypeptid Pentasequenz Valin-Prolin-Glycin-Glycin-Glycin konnte ein Hexapeptid-Makromonomer dargestellt werden, welches anschließend mittels „grafting through“ Polymerisation zur Polymerbürste umgesetzt wurde. Die wurmartige Struktur der Polymerbürsten wurde in AFM-Aufnahmen gezeigt und eine hohe Kettensteifigkeit der Polymerbürsten über dynamische und statische Lichtstreuung nachgewiesen. Zirkulardichroismus-Messungen lieferten Informationen über struktur-, salz- und temperaturabhängige Veränderungen der Konformation. Toxizitätstests und dynamische Lichtstreuung in humanem Blutserum bestätigten die erwartete Biokompatibilität.rnrnBasierend auf zwei Elastin-ähnlichen Polypeptiden mit ähnlicher Peptidsequenz wurden insgesamt vier unterschiedliche Makromonomere mit jeweils 20 Pentapeptid-Wiederholungseinheiten dargestellt. Über anschließende „grafting through“ Polymerisation entstanden molekulare Bürstenmoleküle mit variierenden externen funktionellen Gruppen, die für zukünftige Konjugationsreaktionen verwendet werden können. Der Einfluss von Ionenstärke und Temperatur auf die Konformation der Makromonomere und Polymere wurde mittels Zirkulardichroismus- und Trübungskurven-Messungen untersucht und ein starker Einfluss der hohen Seitenkettendichte auf das Verhalten der Polymerbürsten wurde festgestellt. Über dynamische Lichtstreuung konnte ein von den externen funktionellen Gruppen abhängiges Aggregationsverhalten in humanem Blutserum nachgewiesen werden.rnrnDie in dieser Arbeit synthetisierten Polymerbürsten mit peptidischen Seitenketten stellen damit biokompatible und vielversprechende Trägersysteme für die Konjugation mit Biomolekülen dar, die zukünftig als Drug Delivery-Systeme ihren Einsatz finden können.rn