55 resultados para translucency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of surface sealant on the translucency of composite resin immersed in different solutions. The study involved the following materials: Charisma, Fortify and coffee, Coca-Cola®, tea and artificial saliva as solutions. Sixty-four specimens (n = 8) were manufactured and immersed in artificial saliva at 37 ± 1 °C. Samples were immersed in the solutions for three times a day and re-immersed in artificial saliva until the translucency readings. The measurements were carried out at nine times: T1 - 24 hours after specimen preparation, T2 - 24 hours after immersion in the solutions, T3 - 48 hours and T4 to T9 - 7, 14, 21, 30, 60 and 90 days, respectively, after immersion. The translucency values were measured using a JOUAN device. The results were subjected to ANOVA and Tukey's test at 5%. The surface sealant was not able to protect the composite resin against staining, the coffee showed the strongest staining action, followed by tea and regarding immersion time, a significant alteration was noted in the translucency of composite resin after 21 days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tooth shade results from the interaction between enamel color, enamel translucency and dentine color. A change in any of these parameters will change a tooth’s color. The objective of this study was to evaluate the changes occurring in enamel translucency during a tooth whitening process. Fourteen human tooth enamel fragments, with a mean thickness of 0.96 mm (± 0.3 mm), were subjected to a bleaching agent (10% carbamide peroxide) 8 hours per day for 28 days. The enamel fragment translucency was measured by a computer controlled spectrophotometer before and after the bleaching agent applications in accordance with ANSI Z80.3-1986 - American National Standard for Ophthalmics - nonprescription sunglasses and fashion eyewear-requirements. The measurements were statistically compared by the Mann-Whitney non-parametric test. A decrease was observed in the translucency of all specimens and, consequently, there was a decrease in transmittance values for all samples. It was observed that the bleaching procedure significantly changes the enamel translucency, making it more opaque.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The regular use of mouthrinses, particularly when combined with the use of air-powder polishing, could affect the appearance of tooth-colored restorations. The current study sought to evaluate the effect of NaHCO(3) powder on translucency of a microfilled composite resin immersed in different mouthrinses, at distinct evaluation periods. Eighty disk-shaped specimens of composite resin (Durafill VS, Heraeus Kulzer GmbH & Co. KG, Hanau, Germany) were prepared. The composite specimens were then randomly allocated into two groups according to the surface treatment: exposure to NaHCO(3) powder (10 seconds) or nonexposure, and they were randomly assigned into four subgroups, according to the mouthrinses employed (N = 10): Periogard (Colgate/Palmolive, Sao Bernardo do Campo, SP, Brazil), Cepacol (Aventis Pharma, Sao Paulo, SP, Brazil), Plax (Colgate/Palmolive), and distilled water (control group). The samples were immersed for 2 minutes daily, 5 days per week, over a 4-month test period. Translucency was measured with a transmission densitometer at seven evaluation periods. Statistical analyses (analysis of variance and Tukey`s test) revealed that: distilled water presented higher translucency values (86.72%); Periogard demonstrated the lowest translucency values (72.70%); and Plax (74.05%) and Cepacol (73.32%) showed intermediate translucency values, which were statistically similar between them (p > 0.01). NaHCO(3) air-powder polishing increased the changes in translucency associated with the mouthrinses. Air-powder polishing alone had no effect on material translucency. Translucency percent was gradually decreased from 1 week of immersion up to 4 months. It may be concluded that the NaHCO(3) powder and the tested mouthrinses have affected the translucency of microfilled composite resin, according to the tested time. CLINICAL SIGNIFICANCE During the last decade, the demand for composite resin restorations has grown considerably, however, controversy persists regarding the effect of surface roughness on color stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light dynamics is a relevant phenomenon with respect to esthetic restorations, as incorrect analysis of the optical behavior of natural dentition may lead to potential clinical failures. The nature of incident light plays a major role in determining the amount of light transmission or reflection, and how an object is perceived depends on the nature of the light source. Natural teeth demonstrate translucency, opalescence, and fluorescence, all of which must be replicated by restorative materials in order to achieve clinical success. Translucency is the intermediary between complete opacity and complete transparency, making its analysis highly subjective. In nature, the translucency of dental enamel varies from tooth to tooth, and from individual to individual. Therefore, four important factors must be considered when appraising translucency. Presence or absence of color, thickness of the enamel, degree of translucency, and surface texture are essential components when determining translucency. State-of-the-art resin composites provide varying shades and opacities that deliver a more faithful reproduction of the chromaticity and translucency/opacity of enamel and dentin. This enables the attainment of individualized and customized composite restorations. The objective of this article is to provide a review of the phenomena of translucency and opacity in the natural dentition and composite resins, under the scope of optics, and to describe how to implement these concepts in the clinical setting.CLINICAL SIGNIFICANCEChoosing composite resins, based on optical properties alone, in order to mimic the properties of natural tooth structures, does not necessarily provide a satisfactory esthetic outcome. In many instances, failure ensues from incorrect analysis of the optical behaviors of the natural dentition as well as the improper use of restorative materials. Therefore, it is necessary to implement a technique that enables a restorative material to be utilized to its full potential to correctly replicate the natural teeth.(J Esthet Restor Dent 23:73-88, 2011).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of surface sealant on the translucency of composite resin immersed in different solutions. The study involved the following materials: Charisma, Fortify and coffee, Coca-Cola®, tea and artificial saliva as solutions. Sixty-four specimens (n = 8) were manufactured and immersed in artificial saliva at 37 ± 1 °C. Samples were immersed in the solutions for three times a day and re-immersed in artificial saliva until the translucency readings. The measurements were carried out at nine times: T1 - 24 hours after specimen preparation, T2 - 24 hours after immersion in the solutions, T3 - 48 hours and T4 to T9 - 7, 14, 21, 30, 60 and 90 days, respectively, after immersion. The translucency values were measured using a JOUAN device. The results were subjected to ANOVA and Tukey's test at 5%. The surface sealant was not able to protect the composite resin against staining, the coffee showed the strongest staining action, followed by tea and regarding immersion time, a significant alteration was noted in the translucency of composite resin after 21 days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of fluoride-containing solutions on the translucency of flowable composite resins, with respect the immersion time. Flow-It! (FI) and Natural Flow (NF) composite resins and three commercial brands of fluoride-containing solutions (Fluordent, Fluorgard and Oral B) were used. Specimens were prepared and stored in the solutions at 37degreesC, until the measurements were made after the following treatments: T1 - after 1 hour in relative humidity; T2 - after 1 h in solution; T3 - 24 h; T4 - 48 h; T5 - after a week; from T9, the measurements were accomplished weekly, up to 30-day immersion. To obtain translucency values an electrophoresis equipment was employed. Data were submitted to ANOVA and Tukey tests. The results disclosed that NF showed highest values of translucency and was statistically different from FI (p < 0.001). As regards the solutions, Fluordent and Oral B presented similar values and were statistically superior to Fluorgard (p < 0.05). Concerning the immersion time, similar results were observed for the different evaluation periods. It may be concluded that the fluoride-containing solutions affected the translucency of the composite resins, independently of the materials used. Among the tested resins, NF presented the best performance. (C) 2003 Kluwer Academic Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the color, translucency and fluorescence of bovine enamel and dentin submitted to different bleaching modalities. Pairs of enamel and dentin discs (3 mm in diameter) were obtained from 150 bovine teeth. In 75 of the pairs, one specimen had the enamel removed (Dentin Group). The dentin was removed from one specimen of the remaining 75 pairs (Enamel Group) and the other specimen was left unaltered (Enamel + Dentin). The evaluation of color, translucency and fluorescence was performed with a spectrophotometer using the CIE L* a* b*. Each group was subdivided into three subgroups: Control, composed of specimens that were not bleached, and two experimental subgroups, bleached with either 10% carbamide peroxide (CP10%) or 35% hydrogen peroxide (HP35%). The CP10% bleaching gel was applied 2 h/day for 14 days. The HP35% bleaching agent was applied using two applications of 30 min each, with a one week interval between each application. When not being bleached, the specimens were immersed in artificial saliva. The color, translucency and fluorescence ratings were assessed using spectrophotometry 7 days after the treatment. Regarding color, significant differences were found between bleaching techniques in the groups Enamel and Enamel + Dentin, with a higher color difference for HP35%. Bleaching did not change the translucency of the dental tissues. There were significant differences for fluorescence for the HP35% subgroups of Dentin and Enamel + Dentin, and for the CP10% subgroup of Enamel. Dental bleaching changed the color and fluorescence of the dental tissues, however translucency was not affected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Genetic sonography following first-trimester combined screening appears to increase substantially detection rates for Down syndrome but it relies on the unproved assumption of independence between these tests. In this study we aimed to investigate the relationship between first-trimester nuchal translucency (NT) and a series of second-trimester soft markers and structural defects in unaffected pregnancies. Methods NT measurement in the first trimester was followed by second-trimester scan (18 to 23 + 6 weeks) including examination for three categorical markers (intracardiac echogenic foci, hyperechogenic bowel and structural defects) and measurement of nasal bone length, nuchal-fold thickness, femur length, humerus length, renal pelvis diameter and prenasal thickness. All continuous variables were expressed in multiples of the median (MoM) for gestation and correlation coefficients between log-transformed NT and second-trimester variables were calculated. In addition, frequencies of soft markers and structural defects in cases with increased NT were compared to those with normal NT, using MoM cut-offs. Results In a dataset of 1970 cases, NT was significantly correlated (P < 0.05) with all second-trimester continuous variables, the correlation being strongest for nuchal-fold thickness (r = 0.10). There was a higher frequency of cases with second-trimester nuchal-fold thickness above the 97.5th centile (10.7 vs. 2.2%) and hyperechogenic bowel (2.4 vs. 0.1%) in cases with increased NT. Conclusions Straightforward reassessment of risk using likelihood ratios derived from the second-trimester genetic sonogram might lead to inaccurate estimates. Multivariate models using continuous second-trimester variables might be preferable in sequential screening strategies. Copyright. 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To determine normal blood flow velocities across the fetal tricuspid valve (TV) at 11-13 weeks and 6 days of gestation and to examine the reproducibility of these measurements. Methods A prospective study involving 166 normal singleton pregnancies examined at 11-13 weeks and 6 days was carried out. Descriptive analysis of E- and A-waves` maximum velocities, E/A ratio, duration of the cardiac cycle (C) and diastole (D) and D/C ratio were calculated. Intraobserver and interobserver agreement analysis was performed in a subgroup of 12 cases. Results Average (+/- SD) flow velocities were: E-wave, 25.0 (+/- 4.6) cm/s; A-wave. 42.9 (+/- 5.9) cm/s; E/A, 0.58 (+/- 0.07); cardiac cycle, 390 (+/- 21.1) ms; diastole, 147 (+/- 18) ms and D/C, 0.38 (+/- 0.04). Significant correlation was observed between all parameters (except A-wave) and gestational age but not with nuchal translucency (NT). Intraclass correlation coefficients (interobserver, intraobsever examiner I and intraobserver examiner 2) were: E-wave, 0.53, 0.53 and 0.64; A-wave, 0.45, 0.46 and 0.49; cardiac cycle, 0.70, 0.79 and 0.84 and diastole, 0.63, 0.85 and 0.82, respectively. Conclusions The present study establishes normal Doppler parameters for blood flow across the TV at 11 - 13 weeks and 6 days and demonstrates that these parameters do not correlate with NT measurement and have good/moderate reproducibility. Copyright (C) 2010 John Wiley & Sons, Ltd.