951 resultados para transient loads


Relevância:

70.00% 70.00%

Publicador:

Resumo:

An analysis of the emissions from 14 CNG and 5 Diesel buses was conducted during April & May, 2006. Studies were conducted at both steady state and transient driving modes on a vehicle dynamometer utilising a CVS dilution system. This article will focus on the volatile properties of particles from 4 CNG and 4 Diesel vehicles from within this group with a priority given to the previously un-investigated CNG emissions produced at transient loads. Particle number concentration data was collected by three CPC’s (TSI 3022, 3010 & 3782WCPC) having D50 cut-offs set to 5nm, 10nm & 20nm respectively. Size distribution data was collected using a TSI 3080 SMPS with a 3025 CPC during the steady state driving modes. During transient cycles mono-disperse “slices” of between 5nm & 25nm were measured. The volatility of these particles was determined by placing a thermodenuder before the 3022 and the SMPS and measuring the reduction in particle number concentration as the temperature in the thermodenuder was increased. This was then normalised against the total particle count given by the 3010 CPC to provide high resolution information on the reduction in particle concentration with respect to temperature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION. The intervertebral disc is the largest avascular structure in the human body, withstanding transient loads of up to nine times body weight during rigorous physical activity. The key structural elements of the disc are a gel-like nucleus pulposus surrounded by concentric lamellar rings containing criss-crossed collagen fibres. The disc also contains an elastic fiber network which has been suggested to play a structural role, but to date the relationship between the collagen and elastic fiber networks is unclear. CONCLUSION. The multimodal transmitted and reflected polarized light microscopy technique developed here allows clear differentiation between the collagen and elastic fiber networks of the intervertebral disc. The ability to image unstained specimens avoids concerns with uneven stain penetration or specificity of staining. In bovine tail discs, the elastic fiber network is intimately associated with the collagen network.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study reports the development and performance evaluation of prototypes of biogas-fuelled stationary power generators in the range of 1 kW. Strategies to achieve high engine efficiency namely pulsed manifold injection, electronic throttle control and dual spark plugs, have been incorporated in the prototype. A complete closed-loop control of the engine operation to maintain a steady engine speed of 3000 rpm (+/- 5%) across the entire load range while maintaining an optimum fuel-air equivalence ratio is made possible by an electronic control unit (ECU) controlling the injection duration, ignition timing and throttle position. This study specifically focuses on the response of the generator to transient loads, and the overall efficiency obtained. The results obtained from testing the prototype have been found to be satisfactory and show that biogas power generators for low power applications can be made efficient (overall efficiency of 19% at electrical load of 640 W) using the strategies of biogas fuel injection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Transient power dissipation profiles in handheld electronic devices alternate between high and low power states depending on usage. Capacitive thermal management based on phase change materials potentially offers a fan-less thermal management for such transient profiles. However, such capacitive management becomes feasible only if there is a significant enhancement in the enthalpy change per unit volume of the phase change material since existing bulk materials such as paraffin fall short of requirements. In this thesis I propose novel nanostructured thin-film materials that can potentially exhibit significantly enhanced volumetric enthalpy change. Using fundamental thermodynamics of phase transition, calculations regarding the enhancement resulting from superheating in such thin film systems is conducted. Furthermore design of a microfabricated calorimeter to measure such enhancements is explained in detail. This work advances the state-of-art of phase change materials for capacitive cooling of handheld devices.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Finite element analyses of a long hollow cylinder having an axisymmetric circumferential internal edge crack, subjected to convective cooling on the inner surface are performed. The transient thermal stress intensity factor is estimated using a domain version of the J-integral method. The effect of the thickness of the cylinder, crack length, and heat transfer coefficient on the stress intensity factor history are studied. The variations of critical normalized stress intensity factor with crack length-to-thickness ratio for different parameters are presented. The results show that if a small inner surface crack begins to grow, its stress intensity factor will increase with increase in crack length, reach a maximum, and then begin to drop. Based on the results, a fracture-based design methodology for cracked hollow pipes under transient thermal loads is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this contribution, a stability analysis for a dynamic voltage restorer (DVR) connected to a weak ac system containing a dynamic load is presented using continuation techniques and bifurcation theory. The system dynamics are explored through the continuation of periodic solutions of the associated dynamic equations. The switching process in the DVR converter is taken into account to trace the stability regions through a suitable mathematical representation of the DVR converter. The stability regions in the Thevenin equivalent plane are computed. In addition, the stability regions in the control gains space, as well as the contour lines for different Floquet multipliers, are computed. Besides, the DVR converter model employed in this contribution avoids the necessity of developing very complicated iterative map approaches as in the conventional bifurcation analysis of converters. The continuation method and the DVR model can take into account dynamics and nonlinear loads and any network topology since the analysis is carried out directly from the state space equations. The bifurcation approach is shown to be both computationally efficient and robust, since it eliminates the need for numerically critical and long-lasting transient simulations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper examines a buffer scheme to mitigate the negative impacts of power-conditioned loads on network voltage and transient stabilities. The scheme is based on the use of battery energy-storage systems in the buffers. The storage systems ensure that protected loads downstream of the buffers can ride through upstream voltage sags and swells. Also, by controlling the buffers to operate in either constant impedance or constant power modes, power is absorbed or injected by the storage systems. The scheme thereby regulates the rotor-angle deviations of generators and enhances network transient stability. A computational method is described in which the capacity of the storage systems is determined to achieve simultaneously the above dual objectives of load ride-through and stability enhancement. The efficacy of the resulting scheme is demonstrated through numerical examples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Particle emission measurements from a fleet of 14 CNG and 5 Diesel buses were measured both for transient and steady state mode s on a chassis dynamometer with a CVS dilution system. Several transient DT80 cycles and 4 steady sate modes (0, 25, 50 100% of maximum load) were measured for each bus tested. Particle number concentration data was collected by three CPC’s (TSI 3022, 3010 3782WCPC) having D50 cut-offs set to 5, 10 and 20nm respectively. The size distributions were measured with a TSI 3080 SMPS with a 3025 CPC during the steady state modes. Particle mass emissions were measured with a TSI Dustrak. Particle mass emissions for Diesel buses were upto 2 orders of magnitude higher than for CNG buses. Particle number emissions during steady state modes for Diesel busses were 2 to 5 times higher than for CNG busses for all of the tested loads. On the other hand for the DT80 transient cycle particle number emissions were up to 3 times higher for the CNG buses. More detailed analysis of the transient cycles revealed that the reason for this was due to high particle number emissions from CNG busses during the acceleration parts of the cycles. Particles emitted by the CNG busses during acceleration were in the nucleation mode with the majority being smaller than 10nm. Volatility measurements have also shown that they were highly volatile.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A laboratory model of a thermally driven adsorption refrigeration system with activated carbon as the adsorbent and 1,1,1,2-tetrafluoroethane (HFC 134a) as the refrigerant was developed. The single stage compression system has an ensemble of four adsorbers packed with Maxsorb II specimen of activated carbon that provide a near continuous flow which caters to a cooling load of up to 5W in the 5-18 degrees C region. The objective was to utilise the low grade thermal energy to drive a refrigeration system that can be used to cool some critical electronic components. The laboratory model was tested for it performance at various cooling loads with the heat source temperature from 73 to 93 degrees C. The pressure transients during heating and cooling phases were traced. The cyclic steady state and transient performance data are presented. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phase-change cooling technique is a suitable method for thermal management of electronic equipment subjected to transient or cyclic heat loads. The thermal performance of a phase-change based heat sink under cyclic heat load depends on several design parameters, namely, applied heat flux, cooling heat transfer coefficient, thermophysical properties of phase-change materials (PCMs), and physical dimensions of phase-change storage system during melting and freezing processes. A one-dimensional conduction heat transfer model is formulated to evaluate the effectiveness of preliminary design of practical PCM-based energy storage units. In this model, the phase-change process of the PCM is divided into melting and solidification subprocesses, for which separate equations are written. The equations are solved sequentially and an explicit closed-form solution is obtained. The efficacy of analytical model is estimated by comparing with a finite-volume-based numerical solution for both transient and cyclic heat loads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Submarine pipelines are always trenched within a seabed for reducing wave loads and thereby enhancing their stability. Based on Biot’s poroelastic theory, a two-dimensional finite element model is developed to investigate non-linear wave-induced responses of soil around a trenched pipeline, which is verified with the flume test results by Sudhan et al. [Sudhan, C.M., Sundar, V., Rao, S.N., 2002. Wave induced forces around buried pipeline. Ocean Engineering, 29, 533–544] and Turcotte et al. [Turcotte, B.R., Liu, P.L.F., Kulhawy, F.H., 1984. Laboratory evaluation of wave tank parameters for wave-sediment interaction. Joseph H. Defree Hydraulic Laboratory Report 84-1, School of Civil and Environmental Engineering, Cornell University]. Non-linear wave-induced transient pore pressure around pipeline at various phases of wave loading is examined firstly. Unlike most previous investigations, in which only a single sediment layer and linear wave loading were concerned, in this study, the influences of the non-linearity of wave loading, the physical properties of backfill materials and the geometry profile of trenches on the excess pore pressures within the soil around pipeline, respectively, were explored, taking into account the in situ conditions of buried pipeline in the shallow ocean zones. Based on the parametric study, it is concluded that the shear modulus and permeability of backfill soils significantly affect the wave-induced excess pore pressures around trenched pipeline, and that the effect of wave non-linearity becomes more pronounced and comparable with that of trench depth, especially at high wave steepness in shallow water.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Building integrated photovoltaics (BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influence on the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. Four different roofs are used to assess the impacts of BIPV on the building's heating-and-cooling loads; namely ventilated air-gap BIPV, non-ventilated (closed) air-gap BIPV, closeroof mounted BIPV, and the conventional roof with no PV and no air gap. One-dimensional transient models of four cases are derived to evaluate the PV performances and building cooling-and-heating loads across the different roofs in order to select the appropriate PV building integration method in Tianjin, China. The simulation results show that the PV roof with ventilated air-gap is suitable for the application in summer because this integration leads to the low cooling load and high PV conversion efficiency. The PV roof with ventilation air-gap has a high time lag and small decrement factor in comparison with other three roofs and has the same heat gain as the cool roof of absorptance 0.4. In winter, BIPV of non-ventilated air gap is more appropriate due to the combination of the low heating-load through the PV roof and high PV electrical output. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent research on Variable Stiffness (VS) laminates, which are constructed by steering the fiber orientation as a spatial function of location, have shown to improve laminate performance under mechanical loads. Two distinct cases of stiffness variation can be achieved either by variation of the fiber orientation in the direction of the global x-axis, or perpendicular to it. In the present paper, thermal analysis of a VS laminate is performed to study the effect of steering fibers on transient heat conduction under uniform heat flux using finite element method. The goal of the present paper is a parametric study of the effect of variable stiffness properties on transient response including time to reach steady state and temperature profile. Also, stress resultants and maximum stress location are investigated under different boundary conditions. A FEM algorithm is applied to exactly incorporate the boundary conditions for stress resultant analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent research on Variable Stiffness (VS) laminates, which are constructed by steering the fiber orientation as a spatial function of location, have shown to improve laminate performance under mechanical loads. Two distinct cases of stiffness variation can be achieved either by variation of the fiber orientation in the direction of the global x-axis, or perpendicular to it. In the present paper, thermal analysis of VS laminate is performed to study the effect of steering fibers on transient heat conduction under uniform heat flux using finite element method. The goal of the present paper is a parametric study of the
effect of variable stiffness properties on transient response including time to reach steady state and temperature profile. Also, stress resultants and maximum stress location are investigated under different boundary conditions. A FEM algorithm is applied to exactly incorporate the boundary conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over-frequency generator tripping (OFGT) is used to cut off extra generation to balance power and loads in an isolated system. In this paper the impact of OGFT as a consequence of grid-connected wind farms and under-frequency load shedding (UFLS) is analysed. The paper uses a power system model to demonstrate that wind power fluctuations can readily render OFGT and UFLS maloperation. Using combined hydro and wind generation, the paper proposes a coordinated strategy which resolves problems associated with OFGT and UFLS and preserves system stability.