434 resultados para tracheal intubation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the use of the SensaScope, an S-shaped rigid fibreoptic scope with a flexible distal end, in a series of 13 patients at high risk of, or known to have, a difficult intubation. Patients received conscious sedation with midazolam or fentanyl combined with a remifentanil infusion and topical lidocaine to the oral mucosa and to the trachea via a trans-cricoid injection. Spontaneous ventilation was maintained until confirmation of tracheal intubation. In all cases, tracheal intubation was achieved using the SensaScope. The median (IQR [range]) insertion time (measured from the time the facemask was taken away from the face until an end-expiratory CO(2) reading was visible on the monitor) was 58 s (38-111 [28-300]s). In nine of the 13 cases, advancement of the SensaScope into the trachea was easy. Difficulties included a poor view associated with a bleeding diathesis and saliva, transient loss of spontaneous breathing, and difficulty in advancing the tracheal tube in a patient with unforeseen tracheal narrowing. A poor view in two patients was partially improved by a high continuous flow of oxygen. The SensaScope may be a valuable alternative to other rigid or flexible fibreoptic scopes for awake intubation of spontaneously breathing patients with a predicted difficult airway.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim. To describe the subsequent treatment of airway trauma sustained during laryngoscopy and endotracheal intubation. Methods. A rare injury occurring during laryngoscopy and endotracheal intubation that resulted in perforation of the tongue by an endotracheal tube and the subsequent management of this unusual complication are discussed. A 65-year-old female with intraparenchymal brain hemorrhage with rapidly progressive neurologic deterioration had the airway secured prior to arrival at the referral institution. The endotracheal tube (ETT) was noted to have pierced through the base of the tongue and entered the trachea, and the patient underwent operative laryngoscopy to inspect the injury and the ETT was replaced by tracheostomy. Results. Laryngoscopy demonstrated the ETT to perforate the base of the tongue. The airway was secured with tracheostomy and the ETT was removed. Conclusions. A wide variety of complications resulting from direct and video-assisted laryngoscopy and tracheal intubation have been reported. Direct perforation of the tongue with an ETT and ability to ventilate and oxygenate subsequently is a rare injury.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Tracheal intubation is extremely distressing, painful, and may influence heart rate and blood pressure. Sedatives, analgesics, and muscle relaxants are not commonly used for intubation in neonates. Objectives: This study aimed to evaluate the effects of lidocaine spray as a non-intravenous drug before neonatal intubation on blood pressure, heart rate, oxygen saturation and time of intubation. Patients and Methods: In a randomized, controlled study each neonate was randomly assigned to one of the two study groups by staffs who were not involved in the infant's care. The allocation concealment was kept in an opaque sealed envelope, and the investigators, the patient care team, and the assessors were blinded to the treatment allocation. The selected setting was NICU unit of a teaching hospital in Ilam city, Iran and participants were 60 neonates with indication of tracheal intubation with gestational age >30 weeks. Patients in the treatment group received lidocaine spray and the placebo group received spray of normal saline prior to intubation. Main outcome measurements were the mean rates of blood pressure, heart rate, oxygen saturation, intubation time and lidocaine side effects were measured before and after intubation. Results: Totally 60 newborns including 31 boys and 29 girls were entered into the study (drug group n = 30; placebo group n = 30). Boy/girl ratio in treatment and placebo groups were 1.3 and 0.88, respectively. Mean age ± SD of participants was 34.1 ± 24.8 hours (treatment: 35.3 ± 25.7; placebo: 32.9 ± 24.3; P < 0.0001). Mean weight ± SD of neonates was 2012.5 ± 969 g. Application of lidocaine spray caused a significant reduction of mean intubation time among treatment group compared with placebo group (treatment: 15.03 ± 2.2 seconds; placebo: 18.3 ± 2.3 seconds; P < 0.0001). Mean blood pressure, heart rate and oxygen saturation rate, among neonates in treatment group was reduced after intubation compared with their relevant figures before intubation; however, their differences were not statistically significant except for mean oxygen saturation rate that was reduced significantly in placebo group. No side effects were observed during study. Conclusions: Though the current study revealed some promising results in the application of lidocaine spray during neonatal intubation without any considerable side effects; however, the current investigation could only be considered as a pilot study for further attempts in different locations with higher sample sizes and in different situations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The i-gel™ is a single-use supraglottic airway device (SAD) that allows fibreoptic-guided tracheal intubation through the device. Until now, no prospective data for this procedure are available. Therefore, in a prospective randomized controlled trial, we evaluated fibreoptic-guided tracheal intubation with a standard Rüsch™ PVC tracheal tube (TT) through the i-gel™ compared with the single-use ILMA™ (sILMA™) TT through the sILMA™ in patients with a predicted difficult airway.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Résumé : Contexte clinique et objectifs: l'intubation oro-trachéale peut être plus difficile chez les patients obèses morbides (index de masse corporelle BMI > 35 kg/m2) que chez les patients non-obèses. Récemment, de nouveaux instruments permettant une intubation assistée au moyen d'une caméra ont été développés. Notre expérience pratique avec la vidéolaryngoscopie nous a conduit à l'hypothèse que celle-ci pourrait améliorer la vision laryngoscopique chez cette population spécifique et de ce fait faciliter l'intubation. Le but de cette étude était donc d'évaluer le bénéfice du vidéolaryngoscope sur le grade de laryngoscopie chez le patient obèse morbide. Résultats : le grade laryngoscopique fut abaissé de manière significative avec le vidéolaryngoscope comparé à la vision directe avec un laryngoscope standard. Lorsque le grade laryngoscopique était plus grand que 1 à la laryngoscopie directe, il fut dans la grande majorité des cas (93% des patients) abaissé avec le vidéolaryngoscope. Chez les 7 % restant, le grade laryngoscopique resta identique. Conclusions : chez le patient obèse morbide, l'utilisation du vidéolaryngoscope améliore de manière significative la visualisation du larynx et de ce fait facilite l'intubation. Une application systématique de ce procédé pourrait donc permettre de réduire l'incidence d'une intubation difficile ainsi que ses conséquences chez cette population de patients. Summary : Background and objective: Tracheal intubation may be more difficult in morbidly obese patients (body mass index >35 kgM-2) than in the non-obese. Recently, new video-assisted intubation devices have been developed. After some experience with videolaryngoscopy, we hypothesized that it could improve the laryngoscopic view in this specific population and therefore facilitate intubation. The aim of this study was to assess the benefit of a videolaryngoscope on the grade of laryngoscopy in morbid obesity. Methods: We studied 80 morbidly obese patients undergoing bariatric surgery. They were randomly assigned to one of two groups. One group was intubated with the help of the videolaryngoscope and in the control group the screen of the videolaryngoscope was hidden to the intubating anaesthesiologist. The primary end-point of the study was to assess in both groups the Cormack and Lehane direct and indirect grades of laryngoscopy. The duration of intubation, the number of attempts needed as well as the minimal SPO2 reached during the intubation process were measured. Results: Grade of laryngoscopy was significantly lower with the videolaryngoscope compared with the direct vision (P < 0.001). When the grade of laryngoscopy was higher than one with the direct laryngoscopy (n = 30), it was lower in 28 cases with the videolaryngoscope and remained the same only in two cases (P < 0.001). The minimal SPO2 reached during the intubation was higher with the videolaryngoscope but it did not reach statistical significance. Conclusions: In morbidly obese patients, the use of the videolaryngoscope significantly improves the visualization of the larynx and thereby facilitates intubation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: The present study aimed to describe the characteristics and outcomes of intubation occurring in the ICU and ED of an Australian tertiary teaching hospital. Methods: This was a prospective observational study of intubation practice across the Geelong Hospital over a 6 month period from 1 August 2012 to 31 January 2013. Data were entered by the intubating team through an online data collection form. Results: There were 119 patients intubated and 134 attempts at intubation in the ED and ICU over a 6 month period. The first-pass success rate was 104/119 (87.4%), and all but a single patient was intubated by the second attempt. Propofol, fentanyl, midazolam and suxamethonium were the most common drugs used in rapid sequence induction. AEs were reported in 44/134 (32.8%) of intubation attempts, with transient hypoxia and hypotension being the most common. A significant adverse outcome, namely aspiration pneumonitis, occurred in one patient. There were no peri-intubation deaths. Conclusion: The majority of airways are managed by ICU and ED consultants and trainees, with success rates and AE rates comparable with other published studies. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Modern techniques for surgical treatment of midfacial and panfacial fractures in maxillofacial trauma lead to special problems for airway management. Usually, in perioperative management of panfacial fractures, the surgeon needs to control the dental occlusion and nasal pyramid assessment. For these reasons, oral and nasal endotracheal intubations are contraindicated for the management of panfacial fractures. Tracheotomy is considered by many as the preferred route for airway management in patients with severe maxillofacial fractures, but there are often perioperative and postoperative complications concerning this technique. The submental route for endotracheal intubation has been proposed as an alternative to tracheotomy in the surgical management of patients with panfacial fractures, besides it is accompanied by low morbidity. Thus, this paper aimed to describe the submental endotracheal intubation technique in a patient experiencing panfacial fracture. The subject was well treated using the submental endotracheal intubation to get good reconstruction of the fractures because the authors obtained free access of all facial fractures.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: To determine, in dogs anesthetized with nitrous oxide (N2O), whether the endotracheal tube (ETT) cuffed with a Lanz® pressure regulating valve decreases the tracheal consequences of tracheal intubation. Methods: Sixteen mixed-breed dogs were allocated to two groups according to the ETT used: Control group (n = 8) - Rüsch ETT, and Lanz group (n = 8) - ETT with Lanz® pressure regulating valve. The ETT cuffs in both groups were inflated with air to an intracuff pressure of 30 cm H2O. Anesthesia was induced and maintained with pentobarbitone and N2O (1.5 L·min-1) and O2 (1 L·min-1). ETT cuff pressures were measured before (control) and 60, 120, and 180 min during N2O administration. The dogs were sacrificed, and biopsy specimens from four predetermined areas of the tracheal mucosa in contact with the ETT were collected for light and scanning electron microscopy (SM) examination. Results: Cuff pressures in the Control group were higher than in the Lanz group at all time points studied (P < 0.001), with an increase over time only in the Control group (P < 0.001). Median neutrophilic inflammatory infiltration values of the epithelial surface, and in the subepithelial layer in contact with the cuff, were higher in the Control group as compared to the Lanz group (3.0 vs 1.0 and 3.0 vs 1.5 respectively) (P < 0.05). On SM examination, median histological grades were higher in the Control group compared to Lanz group (2.9 vs 1.9 respectively), (P < 0.05). Conclusions: The Lanz® ETT decreases tracheal mucosal injury in dogs.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Modern techniques for surgical treatment of midfacial and panfacial fractures in maxillofacial trauma lead to special problems for airway management. Usually, in perioperative management of panfacial fractures, the surgeon needs to control the dental occlusion and nasal pyramid assessment. For these reasons, oral and nasal endotracheal intubations are contraindicated for the management of panfacial fractures. Tracheotomy is considered by many as the preferred route for airway management in patients with severe maxillofacial fractures, but there are often perioperative and postoperative complications concerning this technique. The submental route for endotracheal intubation has been proposed as an alternative to tracheotomy in the surgical management of patients with panfacial fractures, besides it is accompanied by low morbidity. Thus, this paper aimed to describe the submental endotracheal intubation technique in a patient experiencing panfacial fracture. The subject was well treated using the submental endotracheal intubation to get good reconstruction of the fractures because the authors obtained free access of all facial fractures.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Video-laryngoscopes are marketed for intubation in difficult airway management. They provide a better view of the larynx and may facilitate tracheal intubation, but there is no adequately powered study comparing different types of video-laryngoscopes in a difficult airway scenario or in a simulated difficult airway situation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG variation) as a potential measure for analgesia and predictor of haemodynamic responsiveness during general anaesthesia. METHODS: Ninety-five patients, ASA I or II, were randomly assigned to five groups [Group 1: bispectral index (BIS) (range) 40-50, effect site remifentanil concentration 1 ng ml(-1);Group 2: BIS 40-50, remifentanil 2 ng ml(-1); Group 3: BIS 40-50, remifentanil 4 ng ml(-1); Group 4: BIS 25-35, remifentanil 2 ng ml(-1); Group 5: BIS 55-65, remifentanil 2 ng ml(-1)]. A 60 mA tetanic stimulus was applied for 5 s on the ulnar nerve. From the digitized pulse oximeter wave recorded on a laptop computer, linear and non-linear parameters of PPG variation during the 60 s period after stimulation were computed. The haemodynamic response to subsequent orotracheal intubation was recorded. The PPG variation was compared between groups and between responders and non-responders to intubation (anova). Variables independently predicting the response were determined by logistic regression. RESULTS: The probability of a response to tracheal intubation was 0.77, 0.47, 0.05, 0.18 and 0.52 in Groups 1-5, respectively (P<0.03). The PPG variability was significantly higher in responders than in non-responders but it did not improve the prediction of the response to tracheal intubation based on BIS level and effect site remifentanil concentration. CONCLUSION: Tetanic stimulation induced PPG variation does not reflect the analgesic state in a wide clinical range of surgical anaesthesia.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Paediatric supraglottic airway devices AmbuAura-i and Air-Q were designed as conduits for tracheal intubation. Although fibreoptic-guided intubation has proved successful, blind intubation as a rescue technique has never been evaluated. OBJECTIVE Evaluation of blind intubation through AmbuAura-i and Air-Q. On the basis of fibreoptic view data, we hypothesised that the success rate with the AmbuAura-i would be higher than with the Air-Q. DESIGN A prospective, randomised controlled trial with institutional review board (IRB) approval and written informed consent. SETTING University Childrens' Hospital; September 2012 to July 2014. PATIENTS Eighty children, American Society of Anesthesiologists (ASA) class I to III, weight 5 to 50 kg. INTERVENTIONS Tracheal intubation was performed through the randomised device with the tip of a fibrescope placed inside and proximal to the tip of the tracheal tube. This permitted sight of tube advancement, but without fibreoptic guidance (visualised blind intubation). MAIN OUTCOME MEASURES Primary outcome was successfully visualised blind intubation; secondary outcomes included supraglottic airway device success, insertion times, airway leak pressure, fibreoptic view and adverse events. RESULTS Personal data did not differ between groups. In contrast to our hypothesis, blind intubation was possible in 15% with the Air-Q and in 3% with the AmbuAura-i [95% confidence interval (95% CI) 6 to 31 vs. 0 to 13%; P = 0.057]. First attempt supraglottic airway device insertion success rates were 95% (Air-Q) and 100% (AmbuAura-i; 95% CI 83 to 99 vs. 91 to 100; P = 0.49). Median leak pressures were 18 cmH2O (Air-Q) and 17 cmH2O [AmbuAura-i; interquartile range (IQR) 14 to 18 vs. 14 to 19 cmH2O; P = 0.66]. Air-Q insertion was slower (27 vs. 19 s, P < 0.001). There was no difference in fibreoptic view, or adverse events (P > 0.05). In one child (Air-Q size 1.5, tube size 3.5), the tube dislocated during device removal. CONCLUSION Ventilation with both devices is reliable, but success of blind intubation is unacceptably low and cannot be recommended for elective or rescue purposes. If intubation through a paediatric supraglottic airway device is desired, we suggest that fibreoptic guidance is used. TRIAL REGISTRATION Clinicaltrials.gov identifier: NCT01692522.