883 resultados para tissue compatibility
Resumo:
The aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylate-based nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (?=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.
Resumo:
The aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylatebased nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (a=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the response of rat subcutaneous tissue to MTA Fillapex® (Angelus), an experimental root canal filling material based on Portland cement and propylene glycol (PCPG), and a zinc oxide, eugenol and iodoform (ZOEI) paste. These materials were placed in polyethylene tubes and implanted into the dorsal connective tissue of Wistar rats for 7 and 15 days. The specimens were stained with hematoxylin and eosin, and evaluated regarding inflammatory reaction parameters by optical microscopy. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated examiners for all experimental periods (kappa=0.96). The histological evaluation showed that all materials caused a moderate inflammatory reaction at 7 days, which subsided with time. A greater inflammatory reaction was observed at 7 days in the tubes filled with ZOEI paste. Tubes filled with MTA Fillapex presented some giant cells, macrophages and lymphocytes after 7 days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The tubes filled with PCPG showed similar results to those observed in MTA Fillapex. At 15 days, the inflammatory reaction was almost absent at the tissue, with several collagen fibers indicating normal tissue healing. Data were analyzed by the nonparametric Kruskal-Wallis test (?=0.05). Statistically significant difference (p<0.05) was found only between PCPG at 15 days and ZOEI at 7 days groups. No significant differences were observed among the other groups/periods (p>0.05). MTA Fillapex and Portland cement added with propylene glycol had greater tissue compatibility than the PCPG paste.
Resumo:
The experiments were designed to evaluate the biocompatibility of a plastically compressed collagen scaffold (PCCS). The ultrastructure of the PCCS was observed via scanning electron microscopy. Twenty New Zealand white rabbits were randomly divided into experimental and control groups that received corneal pocket transplantation with PCCS and an amniotic membrane, respectively. And the contralateral eye of the implanted rabbit served as the normal group. On the 1st, 7th, 14th, 21st, 30th, 60th, 90th, and 120th postoperative day, the eyes were observed via a slit lamp. On the 120th postoperative day, the rabbit eyes were enucleated to examine the tissue compatibility of the implanted stroma. The PCCS was white and translucent. The scanning electron microscopy results showed that fibers within the PCCS were densely packed and evenly arranged. No edema, inflammation, or neovascularization was observed on ocular surface under a slit lamp and few lymphocytes were observed in the stroma of rabbit cornea after histological study. In conclusion, the PCCS has extremely high biocompatibility and is a promising corneal scaffold for an artificial cornea. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2013.
Resumo:
P>Aim To evaluate the kinetics of the inflammatory tissue response to three root canal sealers using a physicochemical method for quantification of the enhanced vascular permeability and histopathological analysis. Methodology Twenty-eight male Wistar rats randomly assigned to four groups according to the evaluation periods (1, 3, 7 and 14 days) were used to assess the vascular permeability and histopathological reaction to RoekoSeal, AH Plus and Sealapex (new formulation) sealers, using saline and Chloropercha as negative and positive controls, respectively. Seven rats were sacrificed per period. The biocompatibility of the sealers was evaluated spectrophotometrically and histopathologically. Results At day 14, Sealapex produced significantly more inflammatory exudate than AH Plus and RoekoSeal (P < 0.05); however, there was no significant difference between AH Plus and RoekoSeal (P > 0.05). Sealapex (new formulation) was the most irritating sealer, producing severe inflammation with the presence of multinucleated giant cells. RoekoSeal was the most biocompatible sealer, producing the least amount of inflammatory exudate. Conclusions RoekoSeal root canal sealer was biocompatible when implanted in connective tissue.
Resumo:
Breast implants are medical devices that are used to augment breast size or to reconstruct the breast following mastectomy or to correct a congenital abnormality. Breast implants consist of a silicone outer shell and a filler (most commonly silicone gel or saline). Approximately 5 to 10 million women worldwide have breast implants. Histomorphometric study to evaluate the biological tissue compatibility of silicone implants suitable for plastic surgery and the adverse effects and risks of this material. Thirty Wistar white rats received subcutaneous implants and the revestiment of silicone gel Silimed ®®, and randomized into six groups of five animals each, according to the type of implanted material and the time of sacrifice. Eight areas of 60.11mm2 corresponding to the obtained surgical pieces were analyzed, counting mesenchymal cells, eosinophils, and foreign body giant cells, observing an acceptable biocompatibility in all implants, for subsequent statistical analysis by Tukey test. Silicone gel showed inflammation slightly greater than for other groups, with tissue reactions varying from light to moderate, whose result was the formation of a fibrous capsule around the material, recognized by the organism as a foreign body. Despite frequent local complications and adverse outcomes, this research showed that the silicone and top layer presented an acceptable chronic inflammatory reaction, which did not significantly differ from the control group. In general, it is possible to affirm that silicone gel had acceptable levels of biocompatibility, confirmed the rare presence of foreign body giant cells, and when of the rupture, formed a fibrous capsule around the material, separating the material of the organism. © AVICENA 2013.
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Objective: Histomorphometric study to evaluate the biological tissue compatibility of silicone implants suitable for plastic surgery. Methods: Thirty Wistar white rats received subcutaneous implants ande the revestiment of silicone gel Silimed, and randomized into six groups of five animals each, according to the type of implanted material and the time of sacrifice. Eight areas of 60.11 mm2 corresponding to the obtained surgical pieces were analyzed, counting mesenchymal cells, eosinophils, and foreign body giant cells, observing an acceptable biocompatibility in all implants, for subsequent statistical analysis by Tukey test. Results: Silicone gel showed inflammation slightly greater than for other groups, with tissue reactions varying from light to moderate, whose result was the formation of a fibrous capsule around the material, recognized by the organism as a foreign body. Conclusion: In general, it is possible to affirm that silicone gel had acceptable levels of biocompatibility, confirmed the rare presence of foreign body giant cells, and when of the rupture, formed a fibrous capsule around the material, separating the material of the organism.
Resumo:
The search for an effective treatment for septic arthritis is ongoing. Current therapies are expensive since they require repeated joint lavage and long term antibiotic treatment. Local application of antimicrobial drugs is advantageous because high concentrations can be attained at the infection site, although repeated injections increase the risk of superinfection of the joint. Thus, slow release formulations, which have the advantage of local treatment yet single application of the drug, are appealing. Antibiotics used in slow release formulations are selected for tissue compatibility, an appropriate antibacterial spectrum, and stability both during the mixing procedure and within the carrier during the release period. Ideally the carriers should be bioresorbable. Promising reports on the clinical use of poly(methyl methacrylate) (PMMA) mixed with several different antibiotics, and of collagen sponges impregnated with gentamicin, should encourage the search for formulations optimally adapted to veterinary medical requirements.
Resumo:
In a prospective randomized controlled double-blind study in 50 acutely injured patients, bacterially contaminated type 2-4 soft tissue wounds were treated with moist dressings of 0.2% Lavasept (fractionated polyhexamethylenbiguanide and macrogolum 4000) solution (n=28) in comparison with Ringer solution (n=22). Standardized swabs were taken on days 0, 2, 8 and 15 and investigated for microorganisms. For a quantitative evaluation, the number of colony forming units (CFU) was determined by a serial dilution technique. The tissue compatibility and anti-inflammatory effect were rated on a scale of 0 (=bad) to 3 (=very good). The most frequently found microorganism was Staphylococcus aureus, which was isolated from 13 wounds. Use of Lavasept led to a faster and significant reduction in microorganisms on the wound surfaces. The number of CFU per wound remained constant or decreased, in contrast to the wounds treated with Ringer solution. This was true for both Gram-positive and Gram-negative bacteria. There was no evidence of impaired wound healing in either group. The anti-inflammatory effect and the tissue compatibility of Lavasept were rated significantly better than that of Ringer solution. It is concluded that Lavasept combines antiseptic action with good tissue compatibility.
Resumo:
Objective-To evaluate local tissue compatibility of doxycycline hyclate (DOX) in antebrachiocarpal joints of calves. Animals-10 healthy calves between 80 and 110 kg. Procedures-Calves were assigned to 2 treatment groups. Calves in groups DOX(low) and DOX(high) were administered 5 and 10 mg of DOX, respectively, locally in 1 antebrachiocarpal joint. The contralateral joint served as a control joint and was injected with 0.9% NaCl solution. General and local clinical findings were scored. Several variables were assessed in blood and synovial fluid for 9 days. Calves were euthanatized and pathologic changes and drug residues evaluated. Results-Throughout the study, none of the calves had clinical changes or abnormal hematologic values. Significant differences between treatment and control joints were evident only for matrix metalloproteinases at 0.5 hours after injection, with less activity for the DOX-treated joints in both treatment groups. Values for all synovial fluid variables, except nitric oxide, increased significantly during the first 12 to 72 hours after arthrocentesis in control and DOX-treated joints. Histologic examination revealed minimal infiltration of inflammatory cells independent of the treatment. No drug residues were detected 9 days after arthrocentesis in any tissues obtained from the liver, kidneys, fat, and skeletal muscles. Conclusions and Clinical Relevance-DOX had excellent intra-articular compatibility in healthy calves. Arthrocentesis induced a mild transient increase of inflammatory mediators in the synovial fluid. Significant decreases in matrix metalloproteinase activity in DOX-treated joints may indicate a potential chondroprotective effect of DOX.
Resumo:
PURPOSE To determine whether particulate debris is present in periprosthetic tissue from revised Dynesys(®) devices, and if present, elicits a biological tissue reaction. METHODS Five Dynesys(®) dynamic stabilization systems consisting of pedicle screws (Ti alloy), polycarbonate-urethane (PCU) spacers and a polyethylene-terephthalate (PET) cord were explanted for pain and screw loosening after a mean of 2.86 years (1.9-5.3 years). Optical microscopy and scanning electron microscopy were used to evaluate wear, deformation and surface damage, and attenuated total reflectance Fourier transform infrared spectroscopy to assess surface chemical composition of the spacers. Periprosthetic tissue morphology and wear debris were determined using light microscopy, and PCU and PET wear debris by polarized light microscopy. RESULTS All implants had surface damage on the PCU spacers consistent with scratches and plastic deformation; 3 of 5 exhibited abrasive wear zones. In addition to fraying of the outer fibers of the PET cords in five implants, one case also evidenced cord fracture. The pedicle screws were unremarkable. Patient periprosthetic tissues around the three implants with visible PCU damage contained wear debris and a corresponding macrophage infiltration. For the patient revised for cord fracture, the tissues also contained large wear particles (>10 μm) and giant cells. Tissues from the other two patients showed comparable morphologies consisting of dense fibrous tissue with no inflammation or wear debris. CONCLUSIONS This is the first study to evaluate wear accumulation and local tissue responses for explanted Dynesys(®) devices. Polymer wear debris and an associated foreign-body macrophage response were observed in three of five cases.
Resumo:
BACKGROUND: XG-102 (formerly D-JNKI1), a TAT-coupled dextrogyre peptide which selectively inhibits the c-Jun N-terminal kinase, is a powerful neuroprotectant in mouse models of middle cerebral artery occlusion (MCAo) with delayed intracerebroventricular injection. We aimed to determine whether this neuroprotection could also be achieved by intravenous injection of XG-102, which is a more feasible approach for future use in stroke patients. We also tested the compatibility of the compound with recombinant tissue plasminogen activator (rtPA), commonly used for intravenous thrombolysis and known to enhance excitotoxicity. METHODS: Male ICR-CD1 mice were subjected to a 30-min-suture MCAo. XG-102 was injected intravenously in a single dose, 6 h after ischemia. Hippocampal slice cultures were subjected to oxygen (5%) and glucose (1 mM) deprivation for 30 min. rtPA was added after ischemia and before XG-102 administration, both in vitro and in vivo. RESULTS: The lowest intravenous dose achieving neuroprotection was 0.0003 mg/kg, which reduced the infarct volume after 48 h from 62 +/- 19 mm(3) (n = 18) for the vehicle-treated group to 18 +/- 9 mm(3) (n = 5, p < 0.01). The behavioral outcome was also significantly improved at two doses. Addition of rtPA after ischemia enhanced the ischemic damage both in vitro and in vivo, but XG-102 was still able to induce a significant neuroprotection. CONCLUSIONS: A single intravenous administration of XG-102 several hours after ischemia induces a powerful neuroprotection. XG-102 protects from ischemic damage in the presence of rtPA. The feasibility of systemic administration of this promising compound and its compatibility with rtPA are important steps for its development as a drug candidate in ischemic stroke.
Resumo:
The purpose of this work was to evaluate the biological compatibility of the Sealapex, Apexit, Sealer 26 and Ketac Endo endodontic cements. Polyethylene tubes containing these cements were implanted in the subcutaneous tissue of 40 (forty) rats. The animals were sacrificed after 14 and 90 days. A descriptive analysis of the reactions found in the connective tissue by contact with the cements was performed. The magnitude of inflammatory infiltrate, the presence and predominance of cell types and their distribution as to the filling material and reparative phenomena, such as fibroblastic and angioblastic proliferation and formation of fibrous capsules, were subjectively measured. After 90 days, all cements presented statistically significant reduction of the inflammatory reaction, presence of a fibrous tissue capsule in contact with the opening of the tubes containing the filling materials, and reduction of fibroblastic proliferation. Angioblastic proliferation decreased only for the Sealer 26 and Ketac Endo groups. All cements tested were either partially or totally phagocyted, and the mildest inflammatory response was found for the Sealer 26 group at both evaluation periods.