805 resultados para tilting pad
Resumo:
Thisresearch deals with the dynamic modeling of gas lubricated tilting pad journal bearings provided with spring supported pads, including experimental verification of the computation. On the basis of a mathematical model of a film bearing, a computer program has been developed, which can be used for the simulation of a special type of tilting pad gas journal bearing supported by a rotary spring under different loading conditions time dependently (transient running conditions due to geometry variations in time externally imposed). On the basis of literature, different transformations have been used in the model to achieve simpler calculation. The numerical simulation is used to solve a non-stationary case of a gasfilm. The simulation results were compared with literature results in a stationary case (steady running conditions) and they were found to be equal. In addition to this, comparisons were made with a number of stationary and non-stationary bearing tests, which were performed at Lappeenranta University of Technology using bearings designed with the simulation program. A study was also made using numerical simulation and literature to establish the influence of the different bearing parameters on the stability of the bearing. Comparison work was done with literature on tilting pad gas bearings. This bearing type is rarely used. One literature reference has studied the same bearing type as that used in LUT. A new design of tilting pad gas bearing is introduced. It is based on a stainless steel body and electron beam welding of the bearing parts. It has good operation characteristics and is easier to tune and faster to manufacture than traditional constructions. It is also suitable for large serial production.
Resumo:
This article presents a methodology for calculating the gains of an output feedback controller for active vibration control of flexible rotors. The methodology is based on modal reduction. The proportional and derivative gains are obtained by adjusting the first two damping factors of the system and keeping the lengths of the two eigenvalues constant in the real-imaginary plane. The methodology is applied to an industrial gas compressor supported by active tilting-pad journal bearings. The unbalance response functions and mode shapes of the flexible rotor with and without active control are presented, showing significative improvement in damping reserve with the control. The importance of sensor location is emphasized, on the basis of the energy necessary to operate the active system over the entire frequency range studied. The best results are obtained by a decentralized controller, observing displacement and velocity of the shaft at the bearing positions.
Resumo:
An HPLC-PAD method using a gold working electrode and a triple-potential waveform was developed for the simultaneous determination of streptomycin and dihydrostreptomycin in veterinary drugs. Glucose was used as the internal standard, and the triple-potential waveform was optimized using a factorial and a central composite design. The optimum potentials were as follows: amperometric detection, E1=-0.15V; cleaning potential, E2=+0.85V; and reactivation of the electrode surface, E3=-0.65V. For the separation of the aminoglycosides and the internal standard of glucose, a CarboPac™ PA1 anion exchange column was used together with a mobile phase consisting of a 0.070 mol L(-1) sodium hydroxide solution in the isocratic elution mode with a flow rate of 0.8 mL min(-1). The method was validated and applied to the determination of streptomycin and dihydrostreptomycin in veterinary formulations (injection, suspension and ointment) without any previous sample pretreatment, except for the ointments, for which a liquid-liquid extraction was required before HPLC-PAD analysis. The method showed adequate selectivity, with an accuracy of 98-107% and a precision of less than 3.9%.
Resumo:
An 8-year-old female neutered Siamese cat was presented with a recent history of incomplete excision of an apocrine gland adenocarcinoma from the palmar aspect of the right antebrachium, just proximal to the carpal joint. There was no evidence of metastasis. Wide surgical excision of the previous surgery site was performed resulting in a soft tissue defect. Partial reconstruction was achieved using digital pad transposition of the first digit (dewclaw), forming a local axial pattern flap that was transposed into the adjacent defect. The remaining defect was closed by primary apposition. The skin flap healed successfully. Some breakdown of the skin closed by primary apposition necessitated open wound management. The cosmetic and functional result of the first digital pad transposition was considered excellent, rendering it a useful means to reconstruct soft tissue defects in the carpal region.
Resumo:
The objective of the article is to evaluate the impact of the friction force mouse-pad in the contraction level of the forearm muscles M. extensor carpi ulnaris, M. extensor digitorum and M. extensor carpi radialis longus. A standard protocol of mouse movements was performed involving horizontal, vertical and diagonal mouse displacements drag-and-drop type. The operators were instructed to execute the protocol with their normal working speed. The movements protocol were performed by each subject (n=17) with three selected pairs mouse-pad, classified as low, medium and high friction force pairs. The mean time to execute the protocol with each mouse was ~138s. Mean values of ~13%MVE and ~17%MVE were found in the M. extensor carpi ulnaris and in the M. extensor digitorum respectively when performing the movements’ protocol. A 8.1% increase in %MVE was observed in the M. extensor digitorum and a 9.4% increase in %MVE was observed in the M. extensor carpi ulnaris when the high friction force pair was operated, relatively to the low friction force pair (p<0.05). The main preliminary conclusions of this study is that operating a high friction force mouse-pad may increase the risk to symptoms or disorders in the wrist due to an increase in the forearm muscles contraction levels, particularly during work with drawing application
Resumo:
PURPOSE: Upright tilt-table testing (UTT) is an useful method for identifying patients with neurocardiogenic syncope, but its role in the evaluation of therapeutic efficacy is controversial. The aim of this study was to determine the correlation between negative UTT after therapy introduction (acute efficacy) and symptom recurrence during follow-up (chronic efficacy). METHODS: We studied 56 severely symptomatic patients (age 27±19 years) with recurrent (7±12 episodes) neurocardiogenic syncope (positive UTT). Once empirical pharmacological therapy was initiated, all patients underwent another UTT (therapeutic evaluation test - TET). Therapy was not modified after TET results. The probability of symptom recurrence was analyzed with the Kaplan-Meier method and compared by log-rank test in patients with negative and positive TET. RESULTS: Negative UTT after therapy was related to a significantly lower probability of recurrence during follow-up (4.9 versus 52.4% in 12 months, P<0.0001). CONCLUSION: A good correlation exists between acute and long-term efficacy of pharmacological therapy for neurocardiogenic syncope, so that serial UTT may be considered a good method for identifying an effective therapeutic strategy.
Resumo:
The etiology of diabetic foot ulceration remains incompletely understood. Among other factors such as foot deformity in the presence of neuropathy, plantar fat pad atrophy has been identified as a contributory factor in diabetic foot ulceration. An association between fat pad atrophy and diabetic foot ulceration has been documented by imaging and histomorphological analysis of the calcaneal fat pad. However, histomorphological analysis of the metatarsal fat pad has not been performed to date. The present study entailed 14 patients with diabetes and 14 nondiabetic controls and was aimed at documenting histomorphological evidence for presumed plantar metatarsal fat pad atrophy in patients with diabetes. Histological stains and computer-assisted planimetry were performed on samples of metatarsal fat obtained during forefoot surgery. The histomorphological and planimetric analyses of adipocyte cross-sectional area and nuclear density demonstrated no differences between patients with diabetes and control patients. Our findings demonstrate that systemic atrophy of the metatarsal fat pad is not present in the diabetic foot and may not explain the structural changes previously proposed by noninvasive imaging. Level of Clinical Evidence: 3.
Resumo:
A mathematical model of the voltage drop which arises in on-chip power distribution networks is used to compare the maximum voltage drop in the case of different geometric arrangements of the pads supplying power to the chip. These include the square or Manhattan power pad arrangement, which currently predominates, as well as equilateral triangular and hexagonal arrangements. In agreement with the findings in the literature and with physical and SPICE models, the equilateral triangular power pad arrangement is found to minimize the maximum voltage drop. This headline finding is a consequence of relatively simple formulas for the voltage drop, with explicit error bounds, which are established using complex analysis techniques, and elliptic functions in particular.
Resumo:
Les personnes âgées atteintes de démence (PAD) souffrent de troubles importants de la communication associés à des manifestations psychologiques et comportementales comme l'agitation. La plupart de ces personnes hospitalisées sont en outre atteintes de comorbidités physiques ou psychologiques pouvant provoquer de l'inconfort. Ce travail décrit la fréquence des comportements d'agitation et de l'inconfort des PAD durant les soins d'hygiène et vérifie si ces deux phénomènes sont associés durant la toilette. La mise en perspective infirmière des résultats de l'étude est effectuée à partir des écrits scientifiques et du cadre théorique du confort de Kolcaba.
Resumo:
Objectives: To determine the efficacy of the pediculate flap with the buccal fat pad in the sealing of orosinusal communications, describe the surgical technique used, and report the main complications. Patients and method: A retrospective study was made of 8 patients seen in the Service of Oral Surgery of the University of Barcelona Dental Clinic (Spain) for the treatment of orosinusal communications between the years 2007 and 2009. In all cases a pediculate flap with the buccal fat pad was used to solve the problem. Results: All of the orosinusal communications were successfully resolved with this technique. The immediate postoperative complications were pain (37.5%), inflammation (37.5%), edema (32.5%), trismus (37.5%), halitosis (14.3%), suppuration (12.5%) and rhinorrhea (12.5%). Conclusions: The use of Bichat"s buccal fat pad is not regarded as the technique of choice for sealing small to medium sized orosinusal communications. However, in the case of large communications, it is a good option, and the results obtained are optimum.
Resumo:
A mathematical model of the voltage drop which arises in on-chip power distribution networks is used to compare the maximum voltage drop in the case of different geometric arrangements of the pads supplying power to the chip. These include the square or Manhattan power pad arrangement, which currently predominates, as well as equilateral triangular and hexagonal arrangements. In agreement with the findings in the literature and with physical and SPICE models, the equilateral triangular power pad arrangement is found to minimize the maximum voltage drop. This headline finding is a consequence of relatively simple formulas for the voltage drop, with explicit error bounds, which are established using complex analysis techniques, and elliptic functions in particular.