31 resultados para thermodilution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over-resuscitation is deleterious in many critically ill conditions, including major burns. For more than 15 years, several strategies to reduce fluid administration in burns during the initial resuscitation phase have been proposed, but no single or simple parameter has shown superiority. Fluid administration guided by invasive hemodynamic parameters usually resulted in over-resuscitation. As reported in the previous issue of Critical Care, Sánchez-Sánchez and colleagues analyzed the performance of a 'permissive hypovolemia' protocol guided by invasive hemodynamic parameters (PiCCO, Pulsion Medical Systems, Munich, Germany) and vital signs in a prospective cohort over a 3-year period. The authors' results confirm that resuscitation can be achieved with below-normal levels of preload but at the price of a fluid administration greater than predicted by the Parkland formula (2 to 4 mL/kg per% burn). The classic approach based on an adapted Parkland equation may still be the simplest until further studies identify the optimal bundle of resuscitation goals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 +/- 2.0 kg.MethodsPropofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD.ResultsAt T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute-1 and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Induced mild hypothermia after cardiac arrest interferes with clinical assessment of the cardiovascular status of patients. In this situation, non-invasive cardiac output measurement could be useful. Unfortunately, arterial pulse contour is altered by temperature, and the performance of devices using arterial blood pressure contour analysis to derive cardiac output may be insufficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Intermittent (IT) and continuous (CT) thermodilution and esophageal Doppler (ED), are all used for hemodynamic monitoring. The aim of this study was to test the agreement between these methods during endotoxin (ET) and dobutamine infusion. METHODS: Twenty-two pigs (39 +/- 1.8 kg body weight) were randomized to general anesthesia and either continuous ET (n = 9) or placebo (PL, n = 13) infusion. After 18 hours of ET or PL infusion, the animals were further randomized to receive dobutamine (n = 3 in ET, n = 5 in PL) or PL. A set of measurements using the three methods were obtained every hour, and the relative blood flow changes between two subsequent measurements were calculated. RESULTS: Bias or limits of agreement for flows were 0.73 L/min or 1.80 L/min for IT and CT, -0.33 L/min or 4.29 L/min for IT and ED, and -1.06 or 3.94 for CT and ED (n = 515, each). For flow changes they were 1% or 44%, 2% or 59%, and 3% or 45%, respectively. Bias and limits of agreement did not differ in ET- and PL-treated animals or in animals with or without dobutamine. Despite significant correlation between any two methods, the respective correlation coefficients (r) were small (IT vs. CT: 0.452; IT vs. ED: 0.042; CT vs. ED: 0.069; all p < 0.001). The same directional changes were measured by any two methods in 49%, 40%, and 50%. When IT flows >5 L/min were compared with IT flows thermodilution methods, especially when cardiac output is >5 L/min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment of regional blood flow changes is difficult in the clinical setting. We tested whether conventional pulmonary artery catheters (PACs) can be used to measure regional venous blood flows by inverse thermodilution (ITD). Inverse thermodilution was tested in vitro and in vivo using perivascular ultrasound Doppler (USD) flow probes as a reference. In anesthetized pigs, PACs were inserted in jugular, hepatic, renal, and femoral veins, and their measurements were compared with simultaneous USD flow measurements from carotid, hepatic, renal, and femoral arteries and from portal vein. Fluid boluses were injected through the PAC's distal port, and temperature changes were recorded from the proximally located thermistor. Injectates of 2 and 5 mL at 22 degrees C and 4 degrees C were used. Flows were altered by using a roller pump (in vitro), and infusion of dobutamine and induction of cardiac tamponade, respectively. In vitro: At blood flows between 400 mL . min-1 and 700 mL . min-1 (n = 50), ITD and USD correlated well (r = 0.86, P < 0.0001), with bias and limits of agreement of 3 +/- 101 mL . min-1. In vivo: 514 pairs of measurements had to be excluded from analysis for technical reasons, and 976 were analyzed. Best correlations were r = 0.87 (P < 0.0001) for renal flow and r = 0.46 (P < 0.0001) for hepatic flow. No significant correlation was found for cerebral and femoral flows. Inverse thermodilution using conventional PAC compared moderately well with USD for renal but not for other flows despite good in vitro correlation in various conditions. In addition, this method has significant technical limitations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The accurate measurement of Cardiac output (CO) is vital in guiding the treatment of critically ill patients. Invasive or minimally invasive measurement of CO is not without inherent risks to the patient. Skilled Intensive Care Unit (ICU) nursing staff are in an ideal position to assess changes in CO following therapeutic measures. The USCOM (Ultrasonic Cardiac Output Monitor) device is a non-invasive CO monitor whose clinical utility and ease of use requires testing. Objectives To compare cardiac output measurement using a non-invasive ultrasonic device (USCOM) operated by a non-echocardiograhically trained ICU Registered Nurse (RN), with the conventional pulmonary artery catheter (PAC) using both thermodilution and Fick methods. Design Prospective observational study. Setting and participants Between April 2006 and March 2007, we evaluated 30 spontaneously breathing patients requiring PAC for assessment of heart failure and/or pulmonary hypertension at a tertiary level cardiothoracic hospital. Methods SCOM CO was compared with thermodilution measurements via PAC and CO estimated using a modified Fick equation. This catheter was inserted by a medical officer, and all USCOM measurements by a senior ICU nurse. Mean values, bias and precision, and mean percentage difference between measures were determined to compare methods. The Intra-Class Correlation statistic was also used to assess agreement. The USCOM time to measure was recorded to assess the learning curve for USCOM use performed by an ICU RN and a line of best fit demonstrated to describe the operator learning curve. Results In 24 of 30 (80%) patients studied, CO measures were obtained. In 6 of 30 (20%) patients, an adequate USCOM signal was not achieved. The mean difference (±standard deviation) between USCOM and PAC, USCOM and Fick, and Fick and PAC CO were small, −0.34 ± 0.52 L/min, −0.33 ± 0.90 L/min and −0.25 ± 0.63 L/min respectively across a range of outputs from 2.6 L/min to 7.2 L/min. The percent limits of agreement (LOA) for all measures were −34.6% to 17.8% for USCOM and PAC, −49.8% to 34.1% for USCOM and Fick and −36.4% to 23.7% for PAC and Fick. Signal acquisition time reduced on average by 0.6 min per measure to less than 10 min at the end of the study. Conclusions In 80% of our cohort, USCOM, PAC and Fick measures of CO all showed clinically acceptable agreement and the learning curve for operation of the non-invasive USCOM device by an ICU RN was found to be satisfactorily short. Further work is required in patients receiving positive pressure ventilation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electronic cigarette-generated mainstream aerosols were characterized in terms of particle number concentrations and size distributions through a Condensation Particle Counter and a Fast Mobility Particle Sizer spectrometer, respectively. A thermodilution system was also used to properly sample and dilute the mainstream aerosol. Different types of electronic cigarettes, liquid flavors, liquid nicotine contents, as well as different puffing times were tested. Conventional tobacco cigarettes were also investigated. The total particle number concentration peak (for 2-s puff), averaged across the different electronic cigarette types and liquids, was measured equal to 4.39 ± 0.42 × 109 part. cm−3, then comparable to the conventional cigarette one (3.14 ± 0.61 × 109 part. cm−3). Puffing times and nicotine contents were found to influence the particle concentration, whereas no significant differences were recognized in terms of flavors and types of cigarettes used. Particle number distribution modes of the electronic cigarette-generated aerosol were in the 120–165 nm range, then similar to the conventional cigarette one.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rationale: There is no effective pharmacological treatment for acute lung injury (ALI). Statins are a potential new therapy because they modify many of the underlying processes important in ALI.

Objectives: To test whether simvastatin improves physiological and biological outcomes in ALI.

Methods: We conducted a randomized, double-blinded, placebo-controlled trial in patients with ALI. Patients received 80 mg simvastatin or placebo until cessation of mechanical ventilation or up to 14 days. Extravascular lung water was measured using thermodilution. Measures of pulmonary and nonpulmonary organ function were assessed daily. Pulmonary and systemic inflammation was assessed by bronchoalveolar lavage fluid and plasma cytokines. Systemic inflammation was also measured by plasma C-reactive protein.

Measurements and Main Results: Sixty patients were recruited. Baseline characteristics, including demographics and severity of illness scores, were similar in both groups. At Day 7, there was no difference in extravascular lung water. By Day 14, the simvastatin-treated group had improvements in nonpulmonary organ dysfunction. Oxygenation and respiratory mechanics improved, although these parameters failed to reach statistical significance. Intensive care unit mortality was 30% in both groups. Simvastatin was well tolerated, with no increase in adverse events. Simvastatin decreased bronchoalveolar lavage IL-8 by 2.5-fold (P = 0.04). Plasma C-reactive protein decreased in both groups but failed to achieve significance in the placebo-treated group.

Conclusions: Treatment with simvastatin appears to be safe and may be associated with an improvement in organ dysfunction in ALI. These clinical effects may be mediated by a reduction in pulmonary and systemic inflammation.




Relevância:

10.00% 10.00%

Publicador:

Resumo:

El compromiso del sistema cardiovascular es frecuente en los pacientes en estado crítico, por tanto la monitorización hemodinámica es esencial para un tratamiento apropiado dirigido a objetivos terapéuticos en este grupo de pacientes. La monitorización hemodinámica del gasto cardíaco y la estimación del volumen intravascular son fundamentales para el manejo de los pacientes pediátricos en estado crítico, la medición del gasto cardíaco es uno de los principales elementos para evaluar la situación hemodinámica y la perfusión tisular de un paciente ayudando a dirigir el tratamiento y a monitorizar la respuesta clínica en pacientes con choque séptico. La hipovolemia es una causa común para la falla circulatoria en pacientes en condición crítica, el encontrar un método confiable para medición de precarga es importante para guiar la administración de líquidos. Tradicionalmente se han utilizado medidas de la volemia asociadas como la presión venosa central (PVC), frecuencia cardiaca (FC), presión arterial (PA) y el gasto urinario. Estos indicadores tienen grandes factores de distracción que hacen que su valor sea limitado y por tanto se tengan que buscar alternativas más confiables. En años recientes se han postulado parámetros dinámicos para la evaluación de la precarga, entre ellos uno de los mas ampliamente estudiado es la medición de la variabilidad de Volumen sistólico (VVS); Este valor se basa en el concepto de que durante la inspiración, la disminución del retorno venoso produce una disminución del Volumen sistólico, lo cual se manifiesta como una disminución en la onda de pulso; Por tanto en una situación de hipovolemia esta diferencia será mayor, dado que será más evidente la disminución del volumen al final de la diástole. En adultos este parámetro se ha convertido en una herramienta útil para evaluar estado de volumen de los pacientes que se encuentran en estado crítico y ha demostrado su utilidad para predecir respuesta a administración de fluidos en diferentes poblaciones de pacientes. En la actualidad no hay estudios en niños que comparen la medición de VVS contra dichas medidas tradicionales de volemia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective
Foot temperature has long been advocated as a reliable noninvasive measure of cardiac output despite equivocal evidence. The aim of this pilot study was to investigate the relationship between noninvasively measured skin temperature and the more invasive core-peripheral temperature gradients (CPTGs), against cardiac output, systemic vascular resistance, serum lactate, and base deficit.

Research methodology
The study was of a prospective, observational and correlational design. Seventy-six measurements were recorded on 10 adults postcardiac surgery. Haemodynamic assessments were made via bolus thermodilution. Skin temperature was measured objectively via adhesive probes, and subjectively using a three-point scale.

Setting
The study was conducted within a tertiary level intensive care unit.

Results
Cardiac output was a significant predictor for objectively measured skin temperature and CPTG (p = .001 and p = .004, respectively). Subjective assessment of skin temperature was significantly related to cardiac output, systemic vascular resistance, and serum lactate (p < .001, respectively).

Conclusions
These results support the utilisation of skin temperature as a noninvasive marker of cardiac output and perfusion. The use of CPTG was shown to be unnecessary, given the parallels in results with the less invasive skin temperature parameters. A larger study is however required to validate these findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We evaluated cardiac output (CO) using three new methods – the auto-calibrated FloTrac–Vigileo (COed), the non-calibrated Modelflow (COmf ) pulse contour method and the ultra-sound HemoSonic system (COhs) – with thermodilution (COtd) as the reference. In 13 postoperative cardiac surgical patients, 104 paired CO values were assessed before, during and after four interventions: (i) an increase of tidal volume by 50%; (ii) a 10 cm H2O increase in positive end-expiratory pressure; (iii) passive leg raising and (iv) head up position. With the pooled data the difference (bias (2SD)) between COed and COtd, COmf and COtd and COhs and COtd was 0.33 (0.90), 0.30 (0.69) and −0.41 (1.11) l.min−1, respectively. Thus, Modelflow had the lowest mean squared error, suggesting that it had the best performance. COed significantly overestimates changes in cardiac output while COmf and COhs values are not significantly different from those of COtd. Directional changes in cardiac output by thermodilution were detected with a high score by all three methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To evaluate the effects of butorphanol on cardiopulmonary parameters in dogs anesthetized with desflurane and breathing spontaneously.Study design Prospective, randomized experimental trial.Animals Twenty dogs weighing 12 +/- 3 kg.Methods Animals were distributed into two groups: a control group (CG) and butorphanol group (BG). Propofol was used for induction and anesthesia was maintained with desflurane (10%). Forty minutes after induction, the dogs in the CG received sodium chloride 0.9% (0.05 mL kg(-1) IM), and dogs in the BG received butorphanol (0.4 mg kg(-1) IM). The first measurements of body temperature (BT), heart rate (HR), arterial pressures (AP), cardiac output (CO), cardiac index (CI), central venous pressure (CVP), stroke volume index (SVI), pulmonary arterial occlusion pressure (PAOP), mean pulmonary arterial pressure (mPAP), left ventricular stroke work (LVSW), systemic (SVR) and pulmonary (PVR) vascular resistances, respiratory rate (fR), and arterial oxygen (PaO(2)) and carbon dioxide (PaCO(2)) partial pressures were taken immediately before the administration of butorphanol or sodium chloride solution (T0) and then at 15-minute intervals (T15-T75).Results In the BG, HR, AP, mPAP and SVR decreased significantly from T15 to T75 compared to baseline. fR was lower at T30 than at T0 in the BG. AP and fR were significantly lower than in the CG from T15 to T75. PVR was lower in the BG than in the CG at T30, while PaCO(2) was higher compared with T0 from T30 to T75 in the BG and significantly higher than in the CG at T30 to T75.Conclusions and clinical relevance At the studied dose, butorphanol caused hypotension and decreased ventilation during desflurane anesthesia in dogs. The hypotension (from 86 +/- 10 to 64 +/- 10 mmHg) is clinically relevant, despite the maintenance of cardiac index.