943 resultados para synchronization protocols


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clock synchronization in wireless sensor networks (WSNs) assures that sensor nodes have the same reference clock time. This is necessary not only for various WSN applications but also for many system level protocols for WSNs such as MAC protocols, and protocols for sleep scheduling of sensor nodes. Clock value of a node at a particular instant of time depends on its initial value and the frequency of the crystal oscillator used in the sensor node. The frequency of the crystal oscillator varies from node to node, and may also change over time depending upon many factors like temperature, humidity, etc. As a result, clock values of different sensor nodes diverge from each other and also from the real time clock, and hence, there is a requirement for clock synchronization in WSNs. Consequently, many clock synchronization protocols for WSNs have been proposed in the recent past. These protocols differ from each other considerably, and so, there is a need to understand them using a common platform. Towards this goal, this survey paper categorizes the features of clock synchronization protocols for WSNs into three types, viz, structural features, technical features, and global objective features. Each of these categories has different options to further segregate the features for better understanding. The features of clock synchronization protocols that have been used in this survey include all the features which have been used in existing surveys as well as new features such as how the clock value is propagated, when the clock value is propagated, and when the physical clock is updated, which are required for better understanding of the clock synchronization protocols in WSNs in a systematic way. This paper also gives a brief description of a few basic clock synchronization protocols for WSNs, and shows how these protocols fit into the above classification criteria. In addition, the recent clock synchronization protocols for WSNs, which are based on the above basic clock synchronization protocols, are also given alongside the corresponding basic clock synchronization protocols. Indeed, the proposed model for characterizing the clock synchronization protocols in WSNs can be used not only for analyzing the existing protocols but also for designing new clock synchronization protocols. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Experiment 1, effects of an intravaginal progesterone insert (CIDR) for synchronization of estrus in non-suckled cycling primiparous Bos indicus beef cows were evaluated. Cows received either no treatment (Control), prostaglandin F(2 alpha) (PGF), or CIDR (6 d)+prostaglandin F(2 alpha) (CIDR+PGF). There were greater (P<0.05) percentages of cows inseminated and pregnant in 4 d of breeding season in CIDR+PGF (81.6%; 48.7%) than in PGF (53.8%; 32.5%) and Control cows (14.6%; 8.5%). In Experiment 2, efficacy of a treatment with CIDR (6 d)+prostaglandin F(2 alpha)+48 h temporary weaning (CIDR+PGF+TW) associated or not with equine chorionic gonadotropin (eCG) for synchronization of estrus in suckled primiparous B. indicus beef cows was evaluated. Cows were assigned to receive either no treatment (Control), CIDR+PGF+TW, CIDR+PGF+TW+200 IU of eCG, or CIDR+PGF+IW+400 IU of eCG. There were greater (P<0.05) percentages of insemination and pregnancy in 4 d of breeding season in treatment groups (47.0%; 27.5%) than in Control cows(4.5%; 3.0%) and in cows treated with eCG (50.9%; 29.4%) than in cows treated only with CIDR+PGF+TW (39.4%: 23.7%). No effects of eCG dosage were detected. The percentage of cows inseminated and pregnant in a 30 d breeding season were greater (P<0.05) in cows assigned to synchronization treatments (53.3%; 37.2%) than in Control cows (35.3%; 21.4%). In the beginning of the BS, non-suckled primiparous cows treated with CIDR+PGF with estrous cycles having been initiated following calving had greater estrous detection and pregnancy rates than PGF and Control cows, and suckled primiparous cows had improved estrous detection and pregnancy rates when eCG was associated with CIDR+PGF+TW. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Five experiments were conducted on commercial farms in Brazil designed to develop the basis for an estrus synchronization protocol using melengestrol acetate (MGA) in Bos indicus cattle. These studies resulted in the development of the following protocol: 0.5 mg.d(-1) of MGA between d -14 and -1; 2.0 mg i.m. injection of estradiol cypionate on d -9; 48 h temporary weaning between d 0 and 2; and natural service beginning on d 0. The basis of this protocol was to induce estrous cyclicity before postpartum loss of body condition, prevent premature luteolysis, eliminate the need for labor required to detect estrus, and consequently increase the likelihood of pregnancy early during the postpartum period. This treatment effectively induced estrous cyclicity among anestrous cows, synchronized estrus activity, and prevented premature luteolysis with no negative effect on pregnancy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an improved and updated taxonomy for Time Warp based distributed synchronization protocols. This taxonomy aims to allow the grouping of several optmistic distributed simulation synchronization protocols, with the objective to facilitate the task to decide which protocol is better for a specific simulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Palhano H.B., Jesus V.L.T., Abidu-Figueiredo M., Baldrighi J.M. & Mello M.R.B. [Effect of nAellore cows ciclicity on conception and pregnant rates after synchronization protocols for fixed timed artificial insemination]. Efeito da ciclicidade de vacas Nelore sobre as taxas de concepcao e de prenhez apos protocolos de sincronizacao para inseminacao artificial em tempo fixo. Revista Brasileira de Medicina Veterinaria, 34(1):63-68, 2012. Departamento de Biologia Animal, Universidade Federal Rural do Rio de Janeiro, BR 465 km 7, Seropedica, RJ 23890-000, Brasil. Email: hbpalhano@gmail.com The present study evaluated the effect on conception and pregnancy rates of Nellore cows selected for Fixed Timed Artificial Insemination (FTAI) program, submitted to four synchronization protocols. Four hundred and ninety lactating females were used and assigned to eight groups: I-OvSynch, n=68, with selection of cycling cows; II-OvSynch + progesterone (P-4), n=67, after selection of non-cycling animals; III-OvSynch, without selection, n=68; IV-OvSynch + P-4, without selection, n=67; V-Co-Synch, n=55, with selection of cycling cows; VI-Co-Synch + P-4, n=55, with selection non-cycling cows; VII- Co-Synch without selection, n=55; VIII- Co-Synch + P-4, without selection, n=55. The conception and pregnancy rates were, respectively, 45.6%, 27.9% and 82.4%, 48.5% for groups I and III; 61.2%, 37.3% and 85.1%, 58.2% for groups II and IV; 43.6%, 25.5% and 80%, 41.8% for groups V and VII; 52.7%, 32.7% and 83.6%, 50.9% for groups VI and VIII. When compared these rates, the results after chi-square test showed significant difference (P < 0.05) among protocols with or without selection. There was no significant difference (P > 0.05) between OvSynch and Co-Synch protocols, with or without P-4 and with selection, considering Co-Synch a viable option for optimization of FTAI. In conclusion, the selection of cows before FTAI program contributed significantly to improve the conception and pregnancy rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effects of the PGF2˛treatment givenat the onset of a synchronization of ovulation protocol using a norgestomet (NORG) earimplant on ovarian follicular dynamics (Experiment 1) and pregnancy per AI (P/AI; Exper-iment 2) in cyclic (CL present) Bos indicus heifers. In Experiment 1, a total of 46 heiferswere presynchronized using two consecutive doses of PGF2˛12 days apart. At first dayof the synchronization protocol the heifers received implants containing 3 mg of NORGand 2 mg of estradiol benzoate (EB). At the same time, heifers were randomly assignedto receive 150 mg of d-cloprostenol (n = 23; PGF2˛) or no additional treatment (n = 23;Control). When the ear implants were removed 8 days later, all heifers received a PGF2˛treatment and 1 mg of EB was given 24 h later. The follicular diameter and interval toovulation were determined by transrectal ultrasonography. No effects of PGF2˛treat-ment on the diameter of the largest follicle present were observed at implant removal(PGF2˛= 9.8 ± 0.4 vs. Control = 10.0 ± 0.3 mm; P = 0.73) or after 24 h (PGF2˛= 11.1 ± 0.4 vs.Control = 11.0 ± 0.4 mm; P = 0.83). No differences in the time of ovulation after ear implantremoval (PGF2˛= 70.8 ± 1.2 vs. Control = 73.3 ± 0.9 h; P = 0.10) or in the ovulation rate(PGF2˛= 87.0 vs. Control = 82.6%; P = 0.64) between treatments were observed. In Experi-ment 2, 280 cyclic heifers were synchronized using the same experimental design describedabove (PGF2˛; n = 143 and Control; n = 137), at random day of the estrous cycle. All heifersreceived 300 IU of equine chorionic gonadotropin (eCG) and 0.5 mg of estradiol cypionate(as ovulatory stimulus) when the NORG ear implants were removed. Timed artificial insem-ination (TAI) was performed 48 h after implant removal and the pregnancy diagnosis wasconducted 30 days later. No effects on the P/AI due to PGF2˛treatment were observed(PGF2˛= 51.7 vs. Control = 57.7%; P = 0.29). In conclusion, PGF2˛treatment at the onset ofNORG-based protocols for the synchronization of ovulation did not alter the ovarian follic-ular responses or the P/AI in cyclic Bos indicus beef heifers synchronized for TAI.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Clock synchronization in a wireless sensor network (WSN) is quite essential as it provides a consistent and a coherent time frame for all the nodes across the network. Typically, clock synchronization is achieved by message passing using a contention-based scheme for media access, like carrier sense multiple access (CSMA). The nodes try to synchronize with each other, by sending synchronization request messages. If many nodes try to send messages simultaneously, contention-based schemes cannot efficiently avoid collisions. In such a situation, there are chances of collisions, and hence, message losses, which, in turn, affects the convergence of the synchronization algorithms. However, the number of collisions can be reduced with a frame based approach like time division multiple access (TDMA) for message passing. In this paper, we propose a design to utilize TDMA-based media access and control (MAC) protocol for the performance improvement of clock synchronization protocols. The basic idea is to use TDMA-based transmissions when the degree of synchronization improves among the sensor nodes during the execution of the clock synchronization algorithm. The design significantly reduces the collisions among the synchronization protocol messages. We have simulated the proposed protocol in Castalia network simulator. The simulation results show that the proposed protocol significantly reduces the time required for synchronization and also improves the accuracy of the synchronization algorithm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper aims to present, using a set of guidelines, how to apply the conservative distributed simulation paradigm (CMB protocol) to develop efficient applications. Using these guidelines, even a user with little experience on distributed simulation and computer architecture can have good performance on distributed simulations using conservative synchronization protocols for parallel processes.The set of guidelines is focus on a specific application domain, the performance evaluation of computer systems, considering models with coarse granularity and few logical processes and running over two platforms: parallel (high performance communication environment) and distributed (low performance communication environment).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Apesar dos avanços tecnológicos alcançados no manejo de criação de búfalos e de técnicas de melhoramento genético, pouco se utilizam na prática para búfalos criados de forma extensiva. O desenvolvimento de protocolos de sincronização, que diminuam o estresse de contenção e reduzem os custos, contribuirá para o incremento da utilização da IATF nos rebanhos bubalinos. O experimento objetivou avaliar um método de sincronização e IATF econômico e pratico compatível ao tipo de criação extensiva. O experimento foi realizado em três fazendas distintas, duas em uma região de várzea, no Estado do Amapá (Local 1 e 2) conduzido na estação reprodutiva favorável. O terceiro no estado do Pará em pastagem cultivada de terra firme. Foram utilizadas 208 búfalas lactantes mestiças mediterrâneo/murrah com idades variadas de 2,5 a 10 anos com histórico de período pós parto ≥ 60 dias. As matrizes que portavam um corpo lúteo foi aplicado 2.0 ml Intra-Muscular de prostaglandina (PGF2α) (150μg/D-cloprostenol) no Dia 0 = D0. Setenta duas horas depois (Dia 3 = D3), foram realizados exame ginecológico para verificar a presença de muco e contratilidade uterina, e posterior inseminação e aplicação de 1.0 ml (100μg) IM de GnRH, com sêmen, de diferentes reprodutores. O diagnóstico de prenhez foi realizado entre 45 a 90 dias, através da palpação retal. O CL-Synch proporcionou uma taxa de prenhez media de 42,79%. Houve efeito significativo das variáveis: presença de contratilidade uterina (χ²= 10.9891; P= 0.0009), muco (χ²= 10.9891; P= 0.0009) e a condição corporal, (χ²= 20.2247; P= 0.0005). A presença do tônus uterino e do muco uterino mostraram-se como excelentes sinais indicativos de uma resposta de crescimento e diferenciação folicular e ovulação à estimulação hormonal. A relação reprodutor e taxa de prenhez não foi estatisticamente significativo (P=0,1684), sugerindo a uniformidade na qualidade do sêmen congelado proveniente da mesma central. Concluí-se que o CL-synch é promissor e suas vantagens se concentram no manejo de contenção das fêmeas e o baixo custo, pois possibilita a contenção somente duas vezes, quando comparado aos demais protocolos que necessitam de contenção de quatro vezes ou mais, diminuindo consideravelmente o estresse.