985 resultados para sybr Green I detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To distinguish the cytoplasm of Danio rerio from that of Gobiocypris rarus, we cloned G. rarus COXI and constructed cytoplasmic molecular markers at the high identity domains of COXI by mutated primer PCR (MP-PCR for short). Then Sybr Green I was used to detect the single amplicon. As a result, we succeeded in getting the cytoplasmic molecular markers, G.M COXI and Z.M COXI, by MP-PCR strategy. They were used to detect the sperm-derived mtDNA in the sexual hybrid embryos (D. rerio female x G. rarus male) before the sphere stage. In the present study, all results demonstrate that MP-PCR approach and Sybr Green I detection are feasible to construct the molecular markers to identify genes that shared high identity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine whether continuous monitoring of SYBR Green I fluorescence provides a reliable and flexible method of quantitative RT-PCR. Our aims were (i) to test whether SYBR Green I analysis could quantify a wide range of known VEGF template concentrations, (ii) to apply this method in an experimental model, and (iii) to determine whether 20 existing primer pairs could be used to quantify their cognate mRNAs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Specific traditional plate count method and real-time PCR systems based on SYBR Green I and TaqMan technologies using a specific primer pair and probe for amplification of iap-gene were used for quantitative assay of Listeria monocytogenes in seven decimal serial dilution series of nutrient broth and milk samples containing 1.58 to 1.58×107 cfu /ml and the real-time PCR methods were compared with the plate count method with respect to accuracy and sensitivity. In this study, the plate count method was performed using surface-plating of 0.1 ml of each sample on Palcam Agar. The lowest detectable level for this method was 1.58×10 cfu/ml for both nutrient broth and milk samples. Using purified DNA as a template for generation of standard curves, as few as four copies of the iap-gene could be detected per reaction with both real-time PCR assays, indicating that they were highly sensitive. When these real-time PCR assays were applied to quantification of L. monocytogenes in decimal serial dilution series of nutrient broth and milk samples, 3.16×10 to 3.16×105 copies per reaction (equals to 1.58×103 to 1.58×107 cfu/ml L. monocytogenes) were detectable. As logarithmic cycles, for Plate Count and both molecular assays, the quantitative results of the detectable steps were similar to the inoculation levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current knowledge of the pathogenic hantavirus indicates that wild rodents are its primary natural reservoir. Specific primers to detect the presence of viral genomes were developed using an SYBR-Green-based real-time RT-PCR protocol. One hundred sixty-four rodents native to the Atlantic Forest biome were captured in So Paulo State, Brazil, and their tissues were tested. The presence of hantavirus RNA was detected in sixteen rodents: three specimens of Akodon montensis, three of Akodon cursor, two of Necromys lasiurus, one of Juliomys sp., one of Thaptomys nigrita, five of Oligoryzomys nigripes, and one of Oryzomys sp. This SYBR Green real-time RT-PCR method for detection of hantavirus may be useful for surveying hantaviruses in Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to optimize an internal control to improve SYBR-Green-based qPCR to amplify/detect the BoHV-5 US9 gene in bovine embryos produced invitro and experimentally exposed to the virus. We designed an SYBR-Green-based binding assay that is quick to perform, reliable, easily optimized and compares well with the published assay. Herein we demonstrated its general applicability to detect BoHV-5 US9 gene in bovine embryos produced invitro experimentally exposed to BoHV-5. In order to validate the assay, three different reference genes were tested; and the histone 2a gene was shown to be the most adequate for normalizing the qPCR reaction, by considering melting and standard curves ( p<0.05). On the other hand, no differences were found in the development of bovine embryos invitro whether they were exposed to BoHV-5 reference and field strains comparing to unexposed embryos. The developed qPCR assay may have important field applications as it provides an accurate BoHV-5 US9 gene detection using a proven reference gene and is considerably less expensive than the TaqMan qPCR currently employed in sanitary programs. © 2013 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DNA amplification using Polymerase Chain Reaction (PCR) in a small volume is used in Lab-on-a-chip systems involving DNA manipulation. For few microliters of volume of liquid, it becomes difficult to measure and monitor the thermal profile accurately and reproducibly, which is an essential requirement for successful amplification. Conventional temperature sensors are either not biocompatible or too large and hence positioned away from the liquid leading to calibration errors. In this work we present a fluorescence based detection technique that is completely biocompatible and measures directly the liquid temperature. PCR is demonstrated in a 3 ILL silicon-glass microfabricated device using non-contact induction heating whose temperature is controlled using fluorescence feedback from SYBR green I dye molecules intercalated within sensor DNA. The performance is compared with temperature feedback using a thermocouple sensor. Melting curve followed by gel electrophoresis is used to confirm product specificity after the PCR cycles. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using the LAMP method, a highly specific and sensitive detection system for genetically modified soybean (Roundup Ready) was designed. In this detection system, a set of four primers was designed by targeting the exogenous 35S epsps gene. Target DNA was amplified and visualized on agarose gel within 45 min under isothermal conditions at 65 degrees C. Without gel electrophoresis, the LAMP amplicon was visualized directly in the reaction tube by the addition of SYBR Green I for naked-eye inspection. The detection sensitivity of LAMP was 10-fold higher than the nested PCR established in our laboratory. Moreover, the LAMP method was much quicker, taking only 70 min, as compared with 300 min for nested PCR to complete the analysis of the GM soybean. Compared with traditional PCR approaches, the LAMP procedure is faster and more sensitive, and there is no need for a special PCR machine or electrophoresis equipment. Hence, this method can be a very useful tool for GMO detection and is particularly convenient for fast screening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The assessment of ERa, PgR and HER2 status is routinely performed today to determine the endocrine responsiveness of breast cancer samples. Such determination is usually accomplished by means of immunohistochemistry and in case of HER2 amplification by means of fluorescent in situ hybridization (FISH). The analysis of these markers can be improved by simultaneous measurements using quantitative real-time PCR (Qrt-PCR). In this study we compared Qrt-PCR results for the assessment of mRNA levels of ERa, PgR, and the members of the human epidermal growth factor receptor family, HER1, HER2, HER3 and HER4. The results were obtained in two independent laboratories using two different methods, SYBR Green I and TaqMan probes, and different primers. By linear regression we demonstrated a good concordance for all six markers. The quantitative mRNA expression levels of ERa, PgR and HER2 also strongly correlated with the respective quantitative protein expression levels prospectively detected by EIA in both laboratories. In addition, HER2 mRNA expression levels correlated well with gene amplification detected by FISH in the same biopsies. Our results indicate that both Qrt-PCR methods were robust and sensitive tools for routine diagnostics and consistent with standard methodologies. The developed simultaneous assessment of several biomarkers is fast and labor effective and allows optimization of the clinical decision-making process in breast cancer tissue and/or core biopsies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In our laboratory, we have developed methods in real-time detection and quantitative-polymerase chain reaction (Q-PCR) to analyse the relative levels of gene expression in post mortem brain tissues. We have then applied this method to examine differences in gene activity between normal white matter (NWM) and plaque tissue from multiple sclerosis (MS) patients. Genes were selected based on their association with pathology and through identification by previously conducted global gene expression analysis. Plaque tissue was obtained from secondary progressive (SP) patients displaying chronic active, as well as acute pathologies; while NWM from the same location was obtained from age- and sex-matched controls (normal patients). In this study, we used both SYBR Green I supplementation and commercially available mixes to assess both comparative and absolute levels of gene activity. The results of both methods compared favourably for four of the five genes examined (P < 0.05, Pearsons), while differences in gene expression between chronic active and acute pathologies were also identified. For example, a >50-fold increase in osteopontin (Spp1) and inositol 1-4-5 phosphate 3 kinase B (Itpkb) levels in acute plaques contrasted with the 5-fold or less increase in chronic active plaques (P < 0.05, unpaired t test). By contrast, there was no significant difference in the levels of the MS marker and calcium-dependent protease (Calpain, Capns1) in MS plaque tissue. In summary, Q-PCR analysis using SYBR Green I has allowed us to economically obtain what may be clinically significant information from small amounts of the CNS, providing an opportunity for further clinical investigations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have successfully achieved the integration of isothermal amplification and the subsequent analysis of specific gene fragments on poly(methyl methacrylate) microchips. In our experiments, loop-mediated isothermal amplification, which can offer higher specificity and efficiency than PCR, has been performed at a constant temperature (65 degreesC). After amplification, products could be either examined by the integrated microchip-based electrophoresis or directly observed by naked eye with SYBR Green I added into the reaction solution. By such an integrated microsystem, the amplification and the subsequent analysis of prostate-specific antigen gene with template concentration at 23 fg/muL could be finished within 15 min, which demonstrates its advantages of high specificity, good reproducibility, and fast speed in gene detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

White-tailed deer (Odocoileus virginianus) have recently emerged as a source of Mycobacterium bovis infection for cattle within North America. The objective of this study was to evaluate the antibody response of M. bovis–infected deer to crude mycobacterial antigens. Deer were experimentally inoculated with M. bovis strain 1315 either by intratonsilar instillation or by exposure to M. bovis–infected (i.e., in contact) deer. To determine the time course of the response, including the effects of antigen administration for comparative cervical skin testing, serum was collected periodically and evaluated by enzyme-linked immunosorbent assay (ELISA) for immunoglobulin (i.e., IgG heavy and light chains) reactivity to mycobacterial antigens. The reactivity to M. bovis purified protein derivative (PPDb) exceeded (P < 0.05) the reactivity to M. avium PPD (PPDa) only after in vivo administration of PPDa and PPDb for comparative cervical testing of the infected deer. The mean immunoglobulin response, as measured by ELISA, of intratonsilar-inoculated deer to a proteinase K–digested whole-cell sonicate (WCS-PK) of M. bovis strain 1315 exceeded (P < 0.05) the mean of the prechallenge responses to this antigen at approximately 1 month after inoculation and throughout the remainder of the study (i.e., ~11 months). This response also exceeded (P < 0.05) that of the uninfected deer. Although this is encouraging, further studies are necessary to validate the use of the proteinase K–digested M. bovis antigens in the antibody-based assays of tuberculosis.

Relevância:

100.00% 100.00%

Publicador: