884 resultados para suture technique
Resumo:
To describe a new suture technique for laryngeal microsurgery and to test its applicability in human cadaver larynges. The new technique was experimentally tested in freshly excised human larynges fixed to a larynx holder appropriate for the simulation of laryngeal microsurgery. A mucosal flap was created in the vocal fold for the fabrication of a pocket for subepithelial fat implantation, and the wound edges were then brought together and sutured using the proposed technique. The time necessary for suture was measured with a stopwatch for five successive sutures performed by one of the surgeons. The presence or absence of mucosal rupture was determined for five sutures performed by two surgeons, for a total of 10 sutures. The sutures were performed without the help of an assistant, with no laceration of the mucosa being observed in any of the attempts, and within a relatively short period of time even without previous training. The sutures performed permitted the implanted fat to remain stable under the mucosal flap. Conclusions: the new suture technique is an easy procedure, which can be performed by a single surgeon under microscopic vision, with a low risk of tissue rupture. The technique does not markedly prolong the duration of surgery and a single suture thread can be used for the fabrication of more than one stitch.
Resumo:
Background: Several studies have already reported the utilization of fibrin glue in microvascular anastomoses to minimize the number of sutures and to decrease the operative time. Despite the good results obtained in most of these experiments, its clinical application has not launched. The aim of this study was to clarify the controversies around the safeness of fibrin glue application in microvascular anastomoses, and also to demonstrate the potential benefits of fibrin glue application in a realistic free flap model. Methods: Twenty-seven rabbits were used in this study The experimental model consisted of a free groin flap transfer to the anterior cervical region. The flap`s circulation was restored by means of an end-to-side anastomosis between the femoral and carotid arteries, and an end-to-end anastomosis between the femoral and external jugular veins. The animals were divided into two groups (n = 10) according to the anastomosis technique: Group I (conventional suture) and group 11 (fibrin glue). Results: The number of sutures required to complete the arterial and venous anastomoses was reduced in 39 and 37% in group 11, respectively. Despite this reduction, the anastomoses maintained adequate patency rates and mechanical strength. Both arterial and venous anastomoses benefited from fibrin glue application, which made them easier and faster to perform. The flaps` ischemic time and the total operative time were also significantly shortened. Conclusions: In this study, the application of fibrin glue in microvascular anastomoses was safe and reliable. The risk-benefit ratio of fibrin glue application in microvascular anastomoses is favorable for its use. (c) 2008 Wiley-Liss, Inc.
Resumo:
OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.
Resumo:
This research presents a new design of an adjustable suture that could provide a better intraocular pressure (IOP) control in the post treatment of trabeculectomy surgery and limit associated complication with the current suturing techniques. A better control in tension suture brings a great deal of advantages to this surgical technique compared with the traditional adjustable suture. A length adjustment can be added in advance to a 10-0 nylon suture which enables suture tension to be released during the postoperative period of trabeculectomy surgery. This adjustment has a D-ring geometry made of 10-0 nylon suture adhered to a 10-0 nylon surgical suture which is used to close the scalar flap. The D ring was adhered with about 180 microdroplet of Loctite 4311that was found to form a strong joint to connect the D ring to the main 10-0 nylon suture and strong enough to carry the added tension instead after cutting the central suture between the two joints of the D ring. The geometry of adjustment is the key factor of maintaining the IOP at the normal range and keeping the scleral flap tight enough and secure so that aqueous humor continues to percolate under the subconjunctiva. It has been found that a 365, and 450 µm length extensions can release suture tension postoperatively and relieve the intraocular pressure within the eye by 33, and 66% respectively. The fabrication process of the new adjustable suture was divided into two steps: fabrication of micro jig and forming microdroplets. A micro jig was fabricated in order to form and bond a precise length extension to the new design of the adjustable suture. In addition, a new liquid separation technique has been followed in this study in order to generate micro adhesive droplets as small as 50µm for bonding the new adjustable suture structure.
Resumo:
Background: Through an experimental biomechanical study on rabbits, tendon reinsertion by means of trans-osseous suture on a spongy bone bed and suture anchor were evaluated comparatively at different phases of healing. Methods: Twenty-four New Zealand White rabbits were used: 2 as pilots, 4 as the control group, and 18 as the experimental group. These 18 animals underwent sectioning and reinsertion of the Achilles tendon bilaterally, using the technique of trans-osseous suture on 1 side and suture anchor on the other. All the pelvic limbs that underwent the procedure were then immobilized for 3 weeks. The experimental group was divided into 3 groups that were sacrificed, respectively, 3, 6, and 12 weeks later. The tendon-bone complex was subjected to biomechanical tests to evaluate the parameters of maximum strength, stiffness, and yield strength. Results: There was no statistically significant difference between the suture anchor group and the trans-osseous suture group, in relation to yield strength (3 weeks, P = .222; 6 weeks, P = .465; and 12 weeks, P = .200) or maximum strength (3 weeks, P = .222; 6 weeks, P = .076; and 12 weeks, P = .078). In relation to stiffness, the suture anchor group showed a statistically significant difference only at 3 weeks of healing ( P = .032) over the trans-osseous suture group. Conclusion: The technique of suturing with an anchor was shown to be similar to the technique of trans-osseous suture for the studied parameters. Level of evidence: Basic Science Study, In-Vitro Biomechanics Study. (C) 2010 Journal of Shoulder and Elbow Surgery Board of Trustees.
Resumo:
BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.
Resumo:
BACKGROUND: Vascular reconstructions are becoming challenging due to the comorbidity of the aging population and since the introduction of minimally invasive approaches. Many sutureless anastomosis devices have been designed to facilitate the cardiovascular surgeon's work and the vascular join (VJ) is one of these. We designed an animal study to assess its reliability and long-term efficacy. METHODS: VJ allows the construction of end-to-end and end-to-side anastomoses. It consists of two metallic crowns fixed to the extremity of the two conduits so that vessel edges are joined layer by layer. There is no foreign material exposed to blood. In adult sheep both carotid arteries were prepared and severed. End-to-end anastomoses were performed using the VJ device on one side and the classical running suture technique on the other side. Animals were followed-up with Duplex-scan every 3 months and sacrificed after 12 months. Histopathological analysis was carried out. RESULTS: In 20 animals all 22 sutureless anastomoses were successfully completed in less than 2 min versus 6 +/- 3 min for running suture. Duplex showed the occlusion of three controls and one sutureless anastomosis. Two controls and one sutureless had stenosis >50%. Histology showed very thin layer of myointimal hyperplasia (50 +/- 10 microm) in the sutureless group versus 300 +/- 27 microm in the control. No significant inflammatory reaction was detected. CONCLUSIONS: VJ provides edge-to-edge vascular repair that can be considered the most physiological way to restore vessel continuity. For the first time, in healthy sheep, an anastomotic device provided better results than suture technique.
Resumo:
Accidents or diseases can affect the peripheral part of the nervous system, which raises clinical and surgical therapies, among others. In this context, the technique of end-to-side neurorrhaphy is a treatment option, yet its modification loop needs some additional efficacy studies. The purpose of this study was to compare, among rats, stereological results (axons volume density) after end-to-side neurorrhaphy and after end-to-side loop neurorrhaphy. Thirty Wistar rats were used, divided into six groups (five animals per group), consisting of two control groups (for the fibular and tibial nerves), two study groups for the fibular nerve (one with an end-to-side neurorrhaphy, and the other with an end-to-side loop neurorrhaphy) and two study groups for the tibial nerve (with an endto- side neurorrhaphy and the other one with an end-to-side loop neurorrhaphy). After 180 days, all groups were sacrificed for axonal stereological analysis (volume density) in distal nerve stumps. There was significant maintenance of neuronal-axonal density in the distal stumps to neurorrhaphy (p< 0.005) compared with the normal stumps. The end-to-side loop neurorrhaphy is a therapeutic option as suture technique after complete nerve section, in order to restore most of the axonal functional integrity.
Resumo:
Thirty-one patients with unilateral long-standing facial palsy underwent I-stage reanimation with free gracilis muscle transplant innervated by the masseteric branch of the trigeminal nerve. They were divided into 2 nonrandomized groups according to insertion technique: group 1 (9 patients), interrupted suture between the free flap and the orbicularis oris of the upper and lower lip on the paralyzed side; group It (22 patients), palmaris longus tendon graft placed between the gracilis free flap and the orbicularis oris of the upper and lower lip on the nonparalyzed side. Qualitative evaluation of the smile demonstrated better results in patients from group II. Comparing the position Of the Cupid`s bow at rest, pre- and postoperatively in each patient, we observed significant improvement of facial symmetry in both groups. During smile, however, there was a significantly higher rate of centralization of the Cupid`s bow in patients submitted to reanimation with the use of the palmaris longus tendon (group II).
Resumo:
Objective: To present the clinical and radiographic results of a case series of patients with acute acromioclavicular dislocation (MD) treated by arthroscopic coracoclavicular fixation with suture anchors. Method: Twenty patients with AAD with less than 30 days since the injury were submitted to a coracoclavicular stabilization procedure using 2 suture anchors placed at the base of the coracoid process. Each suture anchor was connected to 2 strands of No.2 nonabsorbable-braided sutures, which were passed through the holes drilled in the clavicle and tied to the upper surface of the clavicle. The coracoclavicular distance was measured and compared to the opposite side using radiographic evaluation. Constant and UCLA scores were used to determine clinical and functional evaluation after 6 months. Results: Of the initial twenty cases, six were submitted to a new surgical procedure and were excluded from the study. Of the fourteen patients remaining, only two maintained the initial reduction, while the remainder presented some degree of reduction loss. The Constant and UCLA score averages were 94.79 (82-100) and 32.64 (26-35) respectively. Conclusion: The technique had a high incidence of reduction loss after 6 months of follow up. The clinical and functional evaluation was satisfactory, with a high average score. Level of Evidence: Level III, retrospective study.
Resumo:
Background: Several studies have shown that robot-assisted laparoscopic radical prostatectomy (RALP) is feasible, with favorable complication rates and short hospital times. However, the early recovery of urinary continence remains a challenge to be overcome. Objective: We describe our technique of periurethral retropubic suspension stitch during RALP and report its impact on early recovery of urinary continence. Design, setting, and participants: We analyze prospectively 331 consecutive patients who underwent RALP, 94 without the placement of suspension stitch (group 1) and 237 with the application of the suspension stitch (group 2). Surgical procedure: The only difference between the groups was the placement of the puboperiurethral stitch after the ligation of the dorsal venous complex (DVC). The periurethral retropubic stitch was placed using a 12-in monofilament polyglytone suture on a CTI needle. The stitch was passed from right to left between the urethra and DVC, and then through the periostium on the pubic bone. The stitch was passed again through the DVC, and then through the pubic bone in a figure eight, and then tied. Measurements: Continence rates were assessed with a self-administered validated questionnaire (Expanded Prostate Cancer Index Composite [EPIC] at 1, 3, 6, and 12 mo after the procedure. Continence was defined as the use of no absorbent pads or no leakage of urine. Results and limitations: In group 1, the continence rate at 1, 3, 6, and 12 mo postoperatively was 33%, 83%, 94.7%, and 95.7%, respectively; in group 2, the continence rate was 40%, 92.8%, 97.9%, and 97.9%, respectively. The suspension technique resulted in significantly greater continence rates at 3 mo after RALP (p = 0.013). The median/mean interval to recovery of continence was also statistically significantly shorter in the suspension group (median: 6 wk; mean: 7.338 wk: 95% confidence interval [CI]: 6.387-8.288) compared to the non-suspension group (median: 7 wk; mean: 9.585 wk: 95% CI: 7.558-11.612; log rank test, p = 0.02). Conclusions: The suspension stitch during RALP resulted in a statistically significantly shorter interval to recovery of continence and higher continence rates at 3 mo after the procedure. (C) 2009 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Resumo:
Background: Enucleation of small lesions located near the hepatic surface can be achieved with low morbidity and mortality. This article describes a simple laparoscopic technique for enucleation of liver tumors. Methods: After inspection and intraoperative ultrasonography, Glisson`s capsule is marked with eletrocautery 2 cm away from the tumor margin. Ultrasonography is used to ascertain surgical margin right before liver transection. Hemihepatic ischemia is applied and marked area is anchored by stitches. The suture is held together by metallic clips and upward traction is performed, facilitating the transection of the parenchyma and correct identification of vascular and biliary structures. Results: This technique has been successfully employed in six consecutive patients. There were four men and two women, mean age 50.3 years. Four patients underwent liver resection for malignant disease and two for benign liver neoplasm. Pathologic surgical margins were free in all cases and mean hospital stay was 2 days. No postoperative mortality was observed. Conclusion: This technique may facilitate laparoscopic nonanatomical liver resection and reduce risk of positive surgical margins. It is also useful in combination with anatomical laparoscopic liver resections such as right or left hemihepatectomies in patients with bilateral liver tumors as occurred in one of our patients.
Resumo:
Flexor hallucis longus (FHL) transfer is a well-established treatment option in failed Achilles tendon (AT) repair and has been routinely performed as an open procedure. We detail the surgical steps needed to perform an arthroscopic transfer of the FHL for a chronic AT rupture. The FHL tendon is harvested as it enters in its tunnel beneath the sustentaculum tali; a tunnel is then drilled in the calcaneus as near to the AT footprint as possible. By use of a suture-passing device, the free end of the FHL is advanced to the plantar aspect of the foot. After adequate tension is applied to the construct, the tendon is fixed in place with an interference screw in an inside-out fashion. This minimally invasive approach is a safe and valid alternative to classic open procedures with the obvious advantages of preserving the soft-tissue envelope and using a biologically intact tendon.