964 resultados para surgical technique


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To report a new technique to correct tube position in anterior chamber after glaucoma drainage device implantation.

PATIENT AND METHODS: A patient who underwent a glaucoma drainage device implantation was noted to have the tube touching the corneal endothelium. A 10/0 polypropylene suture with double-armed 3-inch long straight needle was placed transcamerally from limbus to limbus, in the superior part of the eye, passing the needle in front of the tube.

RESULTS: The position of the tube in the anterior chamber was corrected with optimal distance from corneal endothelium and iris surface. The position remained satisfactory after 20 months of follow-up.

CONCLUSIONS: The placement of a transcameral suture offers a safe, quick, and minimal invasive intervention for the correction of the position of a glaucoma drainage device tube in the anterior chamber.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had undergone multiple glaucoma laser and surgical procedures, including an initial first Molteno drainage device inserted superonasally that failed in April 2003 due to fibrotic membrane over the tube opening. As a result, he subsequently had a second Molteno drainage device inserted inferotemporally. To further maximize his vision he had an uncomplicated cataract extraction and intraocular lens implant in December 2004, after which he developed postoperative cystoid macular edema and corneal endothelial failure. He underwent a penetrating keratoplasty in the right eye thereafter in March 2007. After approximately a year, the second Molteno device developed drainage tube retraction, which was managed surgically to maintain optimum IOP in the right eye. His right eye vision to date is maintained at 6/12. © 2011 Mustafa and Azuara-Blanco.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A single coronary artery can complicate the surgical technique of arterial switch operations, impairing early and late outcomes. We propose a new surgical approach, successfully applied in a 2.1 kg neonate, aimed at reducing the risk of early and late compression and/or distortion of the newly constructed coronary artery system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The functional results associated with nonoperative treatment of severely impacted valgus fractures of the proximal part of the humerus are poor, and these injuries are difficult to treat with minimally invasive percutaneous fixation techniques. The aim of this study was to review the functional and radiographic results and complications of a new operative technique in a series of twenty-five patients.

Methods: Over a two-year period, we treated twenty-nine patients with a severely impacted valgus fracture of the proximal part of the humerus. Three patients were lost to follow-up and one died, leaving twenty-five patients who were available for the study. In all of the fractures, the head-shaft angle had been tilted into > or = 160 degrees of valgus and the greater tuberosity was displaced by >1 cm. All patients were treated with open reduction of the fracture, and the space created behind the humeral head was filled with Norian Skeletal Repair System (SRS) bone substitute. The fractures were stabilized with either screws or buttress plate fixation. Associated rotator cuff tears were repaired. All patients underwent functional outcome assessment with use of the Constant, DASH (Disabilities of the Arm, Shoulder and Hand), and SF-36 (Short Form-36) scores at one year, and twelve patients were followed for two years.

Results: All fractures united within the first year, all reductions were maintained, and no patient had signs of osteonecrosis of the humeral head on the latest follow-up radiographs. At one year, the median Constant score was 80 points and the median DASH score was 22 points. The functional results continued to be satisfactory in the twelve patients who were followed for two years. The results in our series were better than those achieved in studies of nonoperative treatment of similar fracture configurations. There were six clinically relevant complications, although none required a reoperation and all six patients had a satisfactory short-term functional outcome.

Conclusions: Internal fixation of severely impacted valgus fractures of the proximal part of the humerus, supplemented by Norian SRS bone substitute to fill the proximal humeral metaphyseal defect, produces good early functional and radiographic outcomes. Additional follow-up will be required to assess whether these initially satisfactory outcomes are maintained over the longer term.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This article describes a clinical report with a new system for guided surgical treatment and immediate load prosthesis in the flapless surgical technique. Case report: Based on a computed tomography (CT) of a 64 - year-old edentulous patient, the cross sections were reformatted and used to construct a virtual planning of the implants and a guide template in Dental Slice. Six dental implants were placed in the maxilla and mandible using a Slice Guide System. Following a 30-month in maxilla and 24-month in mandible healing period, the clinical and radiographic evaluation and computed tomography (CT) showed good clinical stability. The Slice Guide System proved satisfactory for the Flapless Surgical Technique in dental implants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several reconstructive methods of the alveolar ridge have been reported to make possible future rehabilitations with implants. Many of these methods come from studies done in animals, mainly rats. With this clinical practice based on scientific evidence, any experimental procedure that can be undertaken in real life is fundamental. Thus, any research that emulates as closely as possible those techniques used in humans are important. This study describes the modification of the technique for block bone graft fixation (onlay) in rats using the lag screw-type technique, normally used in clinical procedures for grafts in humans. The conclusion was that the execution of the described procedures minimizes interference of blood flow in the area because of the maintenance of the muscle insertion in the buckle aspect of the most anterior region of the mandible, providing better stability to the graft and better contact interface of the graft and receptor bed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cancado TO, Omais M, Ashmawi HA, Torres MLA - Chronic Pain after Cesarean Section. Influence of Anesthetic/Surgical Technique and Postoperative Analgesia. Background and objectives: Brazil ranks second among countries with the highest rates of cesarean section in the world. Little is known about the future consequences of this procedure on maternal health. This study investigated the influence of anesthetic/surgical technique and postoperative analgesia on the onset of chronic pain after three months of cesarean section. Method: This is a prospective randomized study of 443 patients undergoing cesarean section (elective and emergency), with different doses of hyperbaric bupivacaine 0.5% and opioids in spinal anesthesia. Patients were alocated into five groups as follow: G1 received hyperbaric bupivacaine (8 mg), sufentanil (2.5 mu g), and morphine (100 mu g); G2 received hyperbaric bupivacaine (10 mg), sufentanil (2.5 mu g), and morphine (100 mu g); G3 received hyperbaric bupivacaine (12.5 mg) and morphine (100 mu g); G4 received hyperbaric bupivacaine (15 mg) and morphine (100 mu g); G5 received hyperbaric bupivacaine (12.5 mg) and morphine (100 mu g), without perioperative anti-inflammatory. Pain at rest and in movement were evaluated in the immediate postoperative period. Phone contact was made after three months of surgery for identification of patients with chronic pain. Results: The incidence of chronic pain in the groups was G1 = 20%; G2 = 13%; G3 = 7.1%; G4 = 2.2%, and G5 = 20.3%. Patients who reported higher pain scores in the postoperative period had a higher incidence of chronic pain (p < 0.05). Conclusion: The incidence of chronic pain decreases with higher doses of local anesthetics and use of anti-inflammatory drugs. The higher pain scores in the postoperative period were associated with chronic pain development after three months of cesarean section.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Codivilla in 1901, Hey Groves in 1926, and Colonna in 1932 described similar capsular arthroplasties--wrapping the capsule around the femoral head and reducing into the true acetabulum--to treat completely dislocated hips in children with dysplastic hips. However, these procedures were associated with relatively high rates of necrosis, joint stiffness, and subsequent revision procedures, and with the introduction of THA, the procedure vanished despite some hips with high functional scores over periods of up to 20 years. Dislocated or subluxated hips nonetheless continue to be seen in adolescents and young adults, and survival curves of THA decrease faster for young patients than for patients older than 60 years. Therefore, joint preservation with capsular arthroplasty may be preferable if function can be restored and complication rates reduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this retrospective cohort study was to evaluate the rate of complications in relation to the extent of surgery and some of its consequences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Recent studies have suggested that tenotomy and repair of the subscapularis tendon carried out for anterior approaches to the shoulder can be followed by failure of the tendon repair and by changes resulting in permanent loss of subscapularis function. We hypothesized that release of the subscapularis with use of a superficial osteotomy of the lesser tuberosity followed by repair of the two opposing bone surfaces would lead to consistent bone-to-bone healing, which would be possible to monitor radiographically, and would lead to satisfactory clinical and structural outcomes. METHODS: Thirty-nine shoulders in thirty-six consecutive patients who, at an average age of fifty-seven years, had undergone total shoulder replacement through an anterior approach involving an osteotomy of the lesser tuberosity were evaluated at an average of thirty-nine months. Assessment included a standardized interview and physical examination, scoring according to the system described by Constant and Murley, and imaging with conventional radiography and computed tomography to assess healing of the osteotomy site and changes in the subscapularis. RESULTS: The osteotomized tuberosity fragment healed in an anatomical position in all shoulders, and no cuff tendon ruptures were observed. At the time of follow-up, thirty-three (89%) of thirty-seven shoulders evaluated with a belly-press test had a negative result and twenty-seven (75%) of thirty-six shoulders evaluated with a lift-off test had an unequivocally normal result. Fatty infiltration of the subscapularis muscle increased after the operation (p < 0.0001) and was at least stage two in eleven (32%) of thirty-four shoulders. The fatty infiltration had progressed by one stage in eight (24%) of the thirty-four shoulders, by two stages in five shoulders (15%), and by three stages in two shoulders (6%). CONCLUSIONS: Osteotomy of the lesser tuberosity provides an easy anterior approach for total shoulder replacement and is followed by consistent bone-to-bone healing, which can be monitored, and good subscapularis function. In the presence of documented anatomical healing of the osteotomy site, postoperative fatty infiltration of the subscapularis muscle remains unexplained and needs to be investigated further as it is associated with a poorer clinical outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Autogenous iliac crest has long served as the gold standard for anterior lumbar arthrodesis although added morbidity results from the bone graft harvest. Therefore, femoral ring allograft, or cages, have been used to decrease the morbidity of iliac crest bone harvesting. More recently, an experimental study in the animal showed that harvesting local bone from the anterior vertebral body and replacing the void by a radio-opaque beta-tricalcium phosphate plug was a valid concept. However, such a concept precludes theoretically the use of posterior pedicle screw fixation. At one institution a consecutive series of 21 patients underwent single- or multiple-level circumferential lumbar fusion with anterior cages and posterior pedicle screws. All cages were filled with cancellous bone harvested from the adjacent vertebral body, and the vertebral body defect was filled with a beta-tricalcium phosphate plug. The indications for surgery were failed conservative treatment of a lumbar degenerative disc disease or spondylolisthesis. The purpose of this study, therefore, was to report on the surgical technique, operative feasibility, safety, benefits, and drawbacks of this technique with our primary clinical experience. An independent researcher reviewed all data that had been collected prospectively from the onset of the study. The average age of the patients was 39.9 (26-57) years. Bone grafts were successfully harvested from 28 vertebral bodies in all but one patient whose anterior procedure was aborted due to difficulty in freeing the left common iliac vein. This case was converted to a transforaminal interbody fusion (TLIF). There was no major vascular injury. Blood loss of the anterior procedure averaged 250 ml (50-350 ml). One tricalcium phosphate bone plug was broken during its insertion, and one endplate was broken because of wrong surgical technique, which did not affect the final outcome. One patient had a right lumbar plexopathy that was not related to this special technique. There was no retrograde ejaculation, infection or pseudoarthrosis. One patient experienced a deep venous thrombosis. At the last follow up (mean 28 months) all patients had a solid lumbar spine fusion. At the 6-month follow up, the pain as assessed on the visual analog scale (VAS) decreased from 6.9 to 4.5 (33% decrease), and the Oswestry disability index (ODI) reduced from 48.0 to 31.7 with a 34% reduction. However, at 2 years follow up there was a trend for increase in the ODI (35) and VAS (5). The data in this study suggest that harvesting a cylinder of autograft from the adjacent vertebral body is safe and efficient. Filling of the void defect with a beta-tricalcium phosphate plug does not preclude the use of posterior pedicle screw stabilization.