906 resultados para surgical forces


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Adolescent idiopathic scoliosis (AIS) is a deformity of the spine, which may 34 require surgical correction by attaching a rod to the patient’s spine using screws 35 implanted in the vertebral bodies. Surgeons achieve an intra-operative reduction in the 36 deformity by applying compressive forces across the intervertebral disc spaces while 37 they secure the rod to the vertebra. We were interested to understand how the 38 deformity correction is influenced by increasing magnitudes of surgical corrective forces 39 and what tissue level stresses are predicted at the vertebral endplates due to the 40 surgical correction. 41 Methods: Patient-specific finite element models of the osseoligamentous spine and 42 ribcage of eight AIS patients who underwent single rod anterior scoliosis surgery were 43 created using pre-operative computed tomography (CT) scans. The surgically altered 44 spine, including titanium rod and vertebral screws, was simulated. The models were 45 analysed using data for intra-operatively measured compressive forces – three load 46 profiles representing the mean and upper and lower standard deviation of this data 47 were analysed. Data for the clinically observed deformity correction (Cobb angle) were 48 compared with the model-predicted correction and the model results investigated to 49 better understand the influence of increased compressive forces on the biomechanics of 50 the instrumented joints. 51 Results: The predicted corrected Cobb angle for seven of the eight FE models were 52 within the 5° clinical Cobb measurement variability for at least one of the force profiles. 53 The largest portion of overall correction was predicted at or near the apical 54 intervertebral disc for all load profiles. Model predictions for four of the eight patients 55 showed endplate-to-endplate contact was occurring on adjacent endplates of one or 56 more intervertebral disc spaces in the instrumented curve following the surgical loading 57 steps. 58 Conclusion: This study demonstrated there is a direct relationship between intra-59 operative joint compressive forces and the degree of deformity correction achieved. The 60 majority of the deformity correction will occur at or in adjacent spinal levels to the apex 61 of the deformity. This study highlighted the importance of the intervertebral disc space 62 anatomy in governing the coronal plane deformity correction and the limit of this 63 correction will be when bone-to-bone contact of the opposing vertebral endplates 64 occurs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION. Following anterior thoracoscopic instrumentation and fusion for the treatment of thoracic AIS, implant related complications have been reported as high as 20.8%. Currently the magnitudes of the forces applied to the spine during anterior scoliosis surgery are unknown. The aim of this study was to measure the segmental compressive forces applied during anterior single rod instrumentation in a series of adolescent idiopathic scoliosis patients. METHODS. A force transducer was designed, constructed and retrofitted to a surgical cable compression tool, routinely used to apply segmental compression during anterior scoliosis correction. Transducer output was continuously logged during the compression of each spinal joint, the output at completion converted to an applied compression force using calibration data. The angle between adjacent vertebral body screws was also measured on intra-operative frontal plane fluoroscope images taken both before and after each joint compression. The difference in angle between the two images was calculated as an estimate for the achieved correction at each spinal joint. RESULTS. Force measurements were obtained for 15 scoliosis patients (Aged 11-19 years) with single thoracic curves (Cobb angles 47˚- 67˚). In total, 95 spinal joints were instrumented. The average force applied for a single joint was 540 N (± 229 N)ranging between 88 N and 1018 N. Experimental error in the force measurement, determined from transducer calibration was ± 43 N. A trend for higher forces applied at joints close to the apex of the scoliosis was observed. The average joint correction angle measured by fluoroscope imaging was 4.8˚ (±2.6˚, range 0˚-12.6˚). CONCLUSION. This study has quantified in-vivo, the intra-operative correction forces applied by the surgeon during anterior single rod instrumentation. This data provides a useful contribution towards an improved understanding of the biomechanics of scoliosis correction. In particular, this data will be used as input for developing patient-specific finite element simulations of scoliosis correction surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Adolescent idiopathic scoliosis (AIS) is the most common form of spinal deformity in paediatrics, prevalent in approximately 2-4% of the general population. While it is a complex three-dimensional deformity, it is clinically characterised by an abnormal lateral curvature of the spine. The treatment for severe deformity is surgical correction with the use of structural implants. Anterior single rod correction employs a solid rod connected to the anterior spine via vertebral body screws. Correction is achieved by applying compression between adjacent vertebral body screws, before locking each screw onto the rod. Biomechanical complication rates have been reported as high as 20.8%, and include rod breakage, screw pull-out and loss of correction. Currently, the corrective forces applied to the spine are unknown. These forces are important variables to consider in understanding the biomechanics of scoliosis correction. The purpose of this study was to measure these forces intra-operatively during anterior single rod AIS correction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At the Mater Children’s Hospital, approximately 80% of patients presenting with Adolescent Idiopathic Scoliosis requiring corrective surgery receive a fulcrum bending radiograph. The fulcrum bending radiograph provides a measurement of spine flexibility and a better indication of achievable surgical correction than lateral-bending radiographs (Cheung and Luk, 1997; Hay et al 2008). The magnitude and distribution of the corrective force exerted by the bolster on the patient’s body is unknown. The objective of this pilot study was to measure, for the first time, the forces transmitted to the patient’s ribs through the bolster during the fulcrum bending radiograph.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Scoliosis is a deformity of the spine which affects children and adolescents, and remains a challenge to treat. This study measured the forces used during surgery to correct scoliosis and studied changes to spinal mechanics from the implantation of metal rods used to hold the spine straight. The results of this study will help surgeons and engineers understand how to straighten the spine more efficiently to provide patients with better outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Cranial cruciate ligament rupture (CCLR) is one of the most important stifle injuries and a common cause of lameness in dogs. Our objective was to measure the vertical forces in the pads of Pitbulls with cranial cruciate ligament rupture (CCLR) using a pressure sensitive walkway. A pressure sensitive walkway was used to collect vertical force data from the pads of 10 Pitbulls affected with unilateral CCLR. Ten healthy Pitbulls were included in the study as controls. Velocity varied between 1.3 and 1.6 m/s and acceleration was kept below ± 0.1 m/s2. Differences between groups and between pads in the same limb within groups were investigated using ANOVA and the Tukey test. The paired Student t-test was employed to assess gait symmetry (p < 0.05). Results: Peak vertical forces (PVF) were lower in the affected limb, particularly in the metatarsal pad. Increased PVF values in the forelimb and the contralateral hind limb pads of affected dogs suggest a compensatory effect. Conclusions: A consistent pattern of vertical force distribution was observed in the pads of dogs with CCLR. These data are important for increased understanding of vertical force distribution in the limb of dogs with CCLR disease. Kinetic analysis using pressure sensitive walkways can be useful in follow-up assessment of surgically treated dogs regardless of the surgical technique employed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Image-guided, computer-assisted neurosurgery has emerged to improve localization and targeting, to provide a better anatomic definition of the surgical field, and to decrease invasiveness. Usually, in image-guided surgery, a computer displays the surgical field in a CT/MR environment, using axial, coronal or sagittal views, or even a 3D representation of the patient. Such a system forces the surgeon to look away from the surgical scene to the computer screen. Moreover, this kind of information, being pre-operative imaging, can not be modified during the operation, so it remains valid for guidance in the first stage of the surgical procedure, and mainly for rigid structures like bones. In order to solve the two constraints mentioned before, we are developing an ultrasoundguided surgical microscope. Such a system takes the advantage that surgical microscopy and ultrasound systems are already used in neurosurgery, so it does not add more complexity to the surgical procedure. We have integrated an optical tracking device in the microscope and an augmented reality overlay system with which we avoid the need to look away from the scene, providing correctly aligned surgical images with sub-millimeter accuracy. In addition to the standard CT and 3D views, we are able to track an ultrasound probe, and using a previous calibration and registration of the imaging, the image obtained is correctly projected to the overlay system, so the surgeon can always localize the target and verify the effects of the intervention. Several tests of the system have been already performed to evaluate the accuracy, and clinical experiments are currently in progress in order to validate the clinical usefulness of the system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: How a scar is managed postoperatively influences Its cosmetic outcome. After Suture removal, scars are susceptible to skin tension, which may be the trigger for hypertrophic scarring. Paper tape to support the scar may reduce multidirectional forces and prevent hypertrophic scarring. Methods: Seventy patients who had under gone cesarean section at the Royal Brisbane and Women's Hospital were randomized to treatment and control groups. Patients in the control group received no postoperative intervention. Patients in the treatment group applied paper tape to their scars for 12 weeks. Scars were assessed at 6 weeks, 12 weeks, and 6 months after surgery using Ultrasound to measure intradermal scar volume. Scars were also assessed using the International Clinical Recommendations. Results: Paper tape significantly decreased scar volume by a mean of 0.16 cm(3), (95 percent confidence Interval, 0.00 to 0.29 cm(3)) At 12 weeks after surgery, 41 percent of the control group developed hypertrophic scars compared with none in the treatment group (exact test, p = 0.003). In the treatment group, one patient developed a hypertrophic scar and four developed stretched scars only after the tape was removed. The odds of developing a hypertrophic scar were 13.6 times greater in the control than in the treatment group (95 percent confidence interval, 3.6 to 66.9). Of the 70 patients randomized, 39 completed the study. Four patients in the treatment group developed a localized red rash beneath the tape. These reactions were minor and transient and resolved without medical intervention. Conclusions: The development of hypertrophic and stretched scars in the treatment group only after the tape was removed suggests that tension acting on a scar is die trigger for hypertrophic scarring. Paper tape is likely to be an effective modality for the prevention of hypertrophic scarring through its ability to eliminate scar tension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hospital acquired infections (HAI) are costly but many are avoidable. Evaluating prevention programmes requires data on their costs and benefits. Estimating the actual costs of HAI (a measure of the cost savings due to prevention) is difficult as HAI changes cost by extending patient length of stay, yet, length of stay is a major risk factor for HAI. This endogeneity bias can confound attempts to measure accurately the cost of HAI. We propose a two-stage instrumental variables estimation strategy that explicitly controls for the endogeneity between risk of HAI and length of stay. We find that a 10% reduction in ex ante risk of HAI results in an expected savings of £693 ($US 984).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently the National Patient Safety Agency in the United Kingdom published a report entitled "Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur". A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.