972 resultados para surface strength


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Offset printing is a popular printing method that is especially suitable for large and fast print jobs. Newspapers, magazines and books are typical examples of products printed with offset method. In high volume printing production high efficiency is essential. Offset printing uses tacky inks that cause serious stress to the paper surface. Dusting and linting are terms that describe how loose and weakly bonded particles are removed from the paper surface in the printing process. The removed particles accumulate in the process causing deteriorating print quality. This forces the printing operators to stop production for washing and cleaning. Time and money are lost. Dusting and linting tendency of paper can be decreased by improving the surface strength of paper. In the present work a method to increase the surface strength of paper was studied. In the literature part offset printing method and challenges related to offset printing are presented. A review of new methods for surface sizing of paper is also presented. The experimental part presents trials where an apparatus for improving paper surface strength was tested and developed in mill scale. Laboratory work supporting the actual mill scale operations is also presented. The acquired results provide a solid base of information to make decisions on how to proceed with research in the present field of study.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The properties of the paper surface play a crucial role in ensuring suitable quality and runnability in various converting and finishing operations, such as printing. Plasma surface modification makes it possible to modify the surface chemistry of paper without altering the bulk material properties. This also makes it possible to investigate the role of the surface chemistry alone on printability without influencing the porous structure of the pigment-coated paper. Since the porous structure of a pigment coating controls both ink setting and optical properties, surface chemical changes created by a plasma modification have a potential to decouple these two effects and to permit a better optimization of them both. The aim of this work was to understand the effects of plasma surface modification on paper properties, and how it influences printability in the sheet-fed offset process. The objective was to broaden the fundamental understanding of the role of surface chemistry on offset printing. The effects of changing the hydrophilicity/ hydrophobicity and the surface chemical composition by plasma activation and plasma coatings on the properties of coated paper and on ink-paper interactions as well as on sheet-fed offset print quality were investigated. In addition, the durability of the plasma surface modification was studied. Nowadays, a typical sheet-fed offset press also contains units for surface finishing, for example UVvarnishing. The role of the surface chemistry on the UV-varnish absorption into highly permeable and porous pigment-coated paper was also investigated. With plasma activation it was possible to increase the surface energy and hydrophilicity of paper. Both polar and dispersion interactions were found to increase, although the change was greater in the polar interactions due to induced oxygen molecular groups. The results indicated that plasma activation takes place particularly in high molecular weight components such as the dispersion chemicals used to stabilize the pigment and latex particles. Surface composition, such as pigment and binder type, was found to influence the response to the plasma activation. The general trend was that pilot-scale treatment modified the surface chemistry without altering the physical coating structure, whereas excessive laboratory-scale treatment increased the surface roughness and reduced the surface strength, which led to micro-picking in printing. It was shown that pilot-scale plasma activation in combination with appropriate ink oils makes it possible to adjust the ink-setting rate. The ink-setting rate decreased with linseed-oil-based inks, probably due to increased acid-base interactions between the polar groups in the oil and the plasma-treated paper surface. With mineral-oil-based inks, the ink setting accelerated due to plasma activation. Hydrophobic plasma coatings were able to reduce or even prevent the absorption of dampening water into pigmentcoated paper, even when the dampening water was applied under the influence of nip pressure. A uniform hydrophobic plasma coating with sufficient chemical affinity with ink gave an improved print quality in terms of higher print density and lower print mottle. It was also shown that a fluorocarbon plasma coating reduced the free wetting of the UV-varnish into the highly permeable and porous pigment coating. However, when the UV-varnish was applied under the influence of nip pressure, which leads to forced wetting, the role of the surface chemical composition seems to be much less. A decay in surface energy and wettability occurred during the first weeks of storage after plasma activation, after which it leveled off. However, the oxygen/carbon elemental ratio did not decrease as a function of time, indicating that ageing could be caused by a re-orientation of polar groups or by a contamination of the surface. The plasma coatings appeared to be more stable when the hydrophobicity was higher, probably due to fewer interactions with oxygen and water vapor in the air.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tämän diplomityön tavoitteena oli selvittää entsyymikonvertoinnin mahdollisuudet vaikuttaa sideainetärkkelyksen toiminnallisiin ominaisuuksiin. Tärkein tehtävä oli etsiä vastaukset kysymykseen, kuinka paljon entsyymikonvertointia optimoimalla voidaan maksimoida tärkkelyksen positiivisia vaikutuksia. Tavoitteena oli myös tutkia, voiko lisäaineita käyttämällä ja tärkkelystä plastisoimalla säilyttää tärkkelyksen vaikutus paperin jäykkyyteen ja saada tärkkelysfilmille joustavuutta. Kirjallisuusosassa tarkasteltiin tärkkelyksen entsyymikonvertointiin vaikuttavia tekijöitä, eri tärkkelysraaka-aineiden eroja, sekä konvertoinnissa käytettävien entsyymien ominaisuuksia. Kirjallisuusosassa tarkasteltiin myöstärkkelyksen käyttöä sideaineena pigmenttipäällystyksessä. Kokeellisessa osassakeskityttiin selvittämään entsyymikonvertoinnin olosuhteiden, käytettävän raakatärkkelyksen ja entsyymin vaikutusta konvertoidun tärkkelyksen ominaisuuksiin. Konvertoiduista tärkkelyksistä valmistettiin päällystyspastat, ja tutkittiin niinpastan kuin päällystetyn paperin ominaisuuksia. Myös erilaisten pehmentimien vaikutusta niin päällystyspastaan, kuin paperin pinnalle tutkittiin. Havaittiin, että konvertoimalla tärkkelysketjua entsymaattisesti, voidaan tärkkelysketjun pituutta säädellä. Tarkoituksena oli konvertoida tärkkelystä niin, että tärkkelyksen molekyyliketjujakaumat sisältävät lyhyitä, keskipitkiä sekäpitkiä molekyylejä. Päällystämisen havaittiin olevan vaikeaa Helicoaterilla varsinkin pitkäketjuista tärkkelystä suuren määrän sisältävillä pastoilla. Myös tärkkelys/lateksi-suhde vaihteli eri pastoilla. Päällystyspastojen reologisia ominaisuuksia testattaessa huomattiin, että tärkkelysketjun pituuden kasvaessa pastanviskositeetti lisääntyy ja vesiretentio vähenee. Havaittiin vain muutamia teknisiä paperiominaisuuksia, jotka korreloivat hyvin tärkkelysketjun pituuden kanssa. Näitä olivat kiilto, Gurley-Hill huokoisuus, taivutusvastus, taivutuspituus sekä IGT pintalujuus. Pehmentimien ei havaittu vaikuttavan moneenkaan paperin eri tekniseen ominaisuuteen. Suurimmat erot huomattiin paperin taivutuspituudessa ja taivutusvastuksessa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pigmenttipäällystyksen tarkoituksena on parantaa painopapereiden pintaominaisuuksia. Tämän työn tarkoituksena oli löytää sopiva päällystyspasta päällystetylle coldset-paperille. Kirjallisuusosassa on käsitelty coldset-painatusta ja sen ongelmia. Päällystysmenetelmän perusteita, pastan ominaisuuksia ja niiden vaikutusta päällystystulokseen on myös käsitelty. Lisäksi on esitelty joitakin päällystetyn paperin pinnantutkimusmenetelmiä. Kokeellisessa osassa on tutkittu erilaisten pastakoostumusten ja päällystemäärien sekä kalanteroinnin vaikutusta paperin painettavuuteen. Paperit on päällystetty Helicoaterilla ja joitakin pastoja on testattu myös pilot-mittakaavaisessa päällystyksessä. Selitystä paperin käyttäytymiseen painatuksessa on etsitty päällystetyn paperin pintarakenteesta. Paras painettavuus saavutetaan päällysteellä, jossa pigmenttinä on vain karbonaatti. Painojälkeä voidaan parantaa käyttämällä kalsinoitua kaoliinia yhdessä karbonaatin kanssa, mutta tämän päällysteen pintalujuus ei ole riittävä CSWO-painatukseen. Tärkkipigmentti parantaa veden ja painovärin absorptiota ja siten tekee painetun tuotteen kuivemmaksi ja miellyttävämmän tuntuiseksi, mutta aiheuttaa smearingia. Tämä johtuu liian nopeasta musteen asettuvuudesta. "Pehmeä" SB-lateksi soveltuu paremmin offset-painatukseen kuin "kova" lateksi, joka sisältää myös PVAc:ta. "Pehmeällä" lateksilla saadaan parempi pintalujuus ja painojälki kuin "kovalla" lateksilla. Paperin pölyävyyttä painatuksessa voidaan vähentää nostamalla päällystemäärää ja laskemalla pastan kuiva-ainepitoisuutta. Kalanteroinnilla ei pintalujuutta tai painojälkeä voida parantaa. Selitys tutkimuksessa käsiteltyjen papereiden painojäljelle ja painettavuudelle löydetään tutkimalla päällysteen pintarakennetta. Painojälkeen vaikuttaa eniten päällysteen peittoaste. Huonoa peittävyyttä voidaan parantaa nostamalla päällystemäärää. Pölyäminen painatuksessa johtuu pigmenteistä, jotka eivät ole sidottuja paperin pintaan. Tämä taas johtuu pastan huonosta vesiretentiosta. Hyödyllisintä tietoa näiden papereiden pintarakenteesta saadaan tutkimalla pintaa pyyhkäisyelektonimikroskoopilla (SEM), atomivoimamikroskoopilla (AFM) ja laserindusoidulla plasmaspektrometrilla (LIPS). LIPSin etuna on se, että päällystemääräjaukauma voidaan määrittää sekä x-y- että z-suunnassa samanaikaisesti samasta kohdasta. LIPSissä myös näytteen preparointitarve on hyvin vähäinen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli selvittää tärkkelyksen ja täyteaineen annostelupaikkojen sekä – tapojen vaikutukset SC- heatset web offset -paperin ominaisuuksiin ja pintalujuuteen. Lisäksi selvitettiin, muuttuuko paperin pölyäminen annostelupaikkojen tai – tapojen vaikutuksesta. Diplomityön kirjallisuusosiossa käsiteltiin heatset web offset -painokoneen rakennetta ja sen toimintaa. Lisäksi käsiteltiin heatset web offset -painokoneella ilmenevät pölyongelmien tyypit ja, mitkä eri paperin tekijät vaikuttavat heatset web offset -painokoneen pölyämisongelmiin. Lisäksi kirjallisuusosiossa käsiteltiin yleisimmät pintalujuutta parantavat kemikaalit sekä näiden kemikaalien annostelupaikat paperikoneen lyhyeen kiertoon. Alkutason määrityksessä ja ensimmäisessä koeajossa havaittiin, että paperin huokoisuus ja huokosrakenne olivat tärkeimmät SC heatset web offset -paperin pintalujuuteen vaikuttavat tekijät. KCL:n HSWO–koepainokoneella painetuista rullista annostelutapa 4, jossa tärkkelystä ja täyteainetta annosteltiin perälaatikon syöttöpumpun imupuolelle perinteisesti, oli pintalujuudeltaan kestävin. Ahmatti-kokeissa havaittiin, että tärkkelyksen ja täyteaineen annostelu TrumpJet- laitteistolla lähempänä paperikoneen perälaatikkoa, annostelutapa 6, pienentää rullan sisäistä vetolujuushajontaa. Ahmatti -pilotkokeissa havaittiin myös, että paperin lujuusominaisuudet ja vetolujuushajonnat voitiin säilyttää entisellään, kun tärkkelystä ja täyteainetta annosteltiin perinteisesti perälaatikon syöttöpumpun imupuolelta. Toisesta koeajon koepainorullasta havaittiin KCL:n koepainatuksissa, että paperin pintalujuus heikentyy annosteltaessa tärkkelystä 8 kg/t verrattuna 10 kg/t tärkkelysannosteluun. Näiden tapojen ero ei ole merkittävä.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We show that the observed K velocities and periodicities of AM CVn can be reconciled given a mass ratio q~0.22 and a secondary star with a modest magnetic field of surface strength B~1 T. We see that the new mass ratio implies that the secondary is most likely semidegenerate. The effect of the field on the accretion disc structure is examined. The theory of precessing discs and resonant orbits is generalized to encompass higher order resonances than 3:2 and shown to retain consistency with the new mass ratio.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: The objective of this study was to evaluate the influence of the surface treatment and acid conditioning (AC) time of bovine sclerotic dentine on the micro-tensile bond strength (mu-TBS) to an etch and rinse adhesive system. Materials and method: Thirty-six bovine incisors were divided into six groups (n = 6): G1 sound dentine submitted to AC for 15 s; G2-G6 sclerotic dentine: G2-AC for 15 s; G3-AC for 30 s; G4-EDTA and AC for 15 s; G5-diamond bur and AC for 15 s; G6-diamond paste and AC for 15 s. An adhesive system was applied to the treated dentine surfaces followed by a hybrid composite inserted in increments and light cured. After 24 h storage in water at 37 degrees C, the specimens were perpendicularly cut with a low-speed diamond saw to obtain beams (0.8 mm x 0.8 mm cross-sectional dimensions) for mu-TBS testing. Data was compared by ANOVA followed by Tukey`s test (P <= 0.05). Results: The mean L-TBS was G1: 18.87 +/- 5.36 MPa; G2: 12.94 +/- 2.09 MPa; G3: 11.73 +/- 0.64 MPa; G4: 11.14 +/- 1.50 MPa; G5: 22.75 +/- 4.10 MPa; G6: 22.48 +/- 2.71 MPa. G1, G5 and G6 presented similar bond strengths significantly higher than those of all other groups. Conclusion: The surface treatment of sclerotic dentine significantly influenced the bond strength to an adhesive system. Mechanical treatment, either using a diamond bur or a diamond paste was able to improve bonding to bovine sclerotic dentine, reaching values similar to bonding to sound dentine. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To evaluate the tensile bond strength of indirect composites repaired with different surface treatments and direct composites. Methods: 180 specimens were prepared with Targis, belleGlass HP and Sculpture indirect composites, light-activated and post-cured according to the manufacturers` recommendations. The specimens were stored in distilled water for 24 hours at 37 degrees C. The bonding surfaces were prepared with air abrasion, hydrofluoric acid or hydrofluoric acid followed by a neutralizing solution. All the treated surfaces were subject to the application of a silane and a bonding agent before the repair procedures with Tetric Ceram and Tetric Flow for the Targis specimens, Herculite XRV and Revolution for the belleGlass HP specimens and Sculp-It and Flow-It for Sculpture specimens. The tensile bond strength tests were carried out using a universal testing machine at cross-head speed of 0.5 mm/minute. The type of fracture was observed under a light microscope at x40 magnification. Data were analyzed by a two-way ANOVA and Tukey`s post-hoc tests (P<0.05). Results: Targis showed a statistically higher repair bond strength than belleGlass HP and Sculpture, which were not significantly different from each other. Air abrasion increased the repair bond strength of belleGlass HP and Sculpture. For Targis, all the surface treatments resulted in similar repair bond strength. The different viscosity of repair composites did not affect the repair of indirect composites. Fractured surfaces showed mostly adhesive failures, mainly with hydrofluoric acid treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Salivary contamination is one of the factors that can disturb the sealing process and interfere in the longevity of pit and fissure sealants. Erbium : yttrium-aluminum-garnet (Er : YAG) laser could influence the bond strength of enamel and increase the acid resistance. To evaluate the influence of Er : YAG laser on the shear bond strength of a sealant to a salivary contaminated enamel surface. Twenty-four third molars had the roots sectioned 2 mm coronal to the cementoenamel junction. The crowns were mesiodistally sectioned providing 48 halves that were embedded in polyester resin. Enamel was flattened and a 2-mm diameter bonding area was demarcated. Specimens were randomly assigned to two groups according to the superficial pretreatment-37% phosphoric acid (A) and Er : YAG laser (80 mJ/2 Hz) + phosphoric acid (L), which were subdivided into two groups (N = 12), without salivary contamination (C) and with salivary contamination (SC). To contaminate the specimens, 0.25 mL of human fresh saliva was applied for 20 seconds and then dried. Fluroshield sealant was applied in all specimens. After storage, shear bond strength of samples were tested in a universal testing machine. Means in MPa were: AC-14.61 (+/- 2.52); ASC-6.66 (+/- 2.34); LC-11.91 (+/- 1.34); and LSC-2.22 (+/- 0.66). Statistical analysis revealed that surfaces without salivary contamination and with acid treatment had the highest mean (p < 0.05). The group with salivary contamination treated by Er : YAG laser followed by phosphoric acid application presented the lowest bond values (p < 0.05). The phosphoric acid etching under dry condition yielded better bonding performance. Er : YAG laser was not able to increase the effectiveness of conventional acid etching of enamel in the bond of sealants in both dry and wet conditions. Under the conditions of this study, the conventional etching protocol (phosphoric acid without salivary contamination) is still preferable to laser-conditioning enamel surface prior to sealant application.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Interest in polyethylene and polypropylene bonding has increased in the last years. However, adhesive joints with adherends which are of low surface energy and which are chemically inert present several difficulties. Generally, their high degree of chemical resistance to solvents and dissimilar solubility parameters limit the usefulness of solvent bonding as a viable assembly technique. One successful approach to adhesive bonding of these materials involves proper selection of surface pre-treatment prior to bonding. With the correct pre-treatment it is possible to glue these materials with one or more of several adhesives required by the applications involved. A second approach is the use of adhesives without surface pre-treatment, such as hot melts, high tack pressure-sensitive adhesives, solvent-based specialty adhesives and, more recently, structural acrylic adhesives as such 3M DP-8005® and Loctite 3030®. In this paper, the shear strengths of two acrylic adhesives were evaluated using the lap shear test method ASTM D3163 and the block shear test method ASTM D4501. Two different industrial polyolefins (polyethylene and polypropylene) were used for adherends. However, the focus of this study was to measure the shear strength of polyethylene joints with acrylic adhesives. The effect of abrasion was also studied. Some test specimens were manually abraded using 180 and 320 grade abrasive paper. An additional goal of this work was to examine the effect of temperature and moisture on mechanical strength of adhesive joints.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction : La force d’adhésion à l'interface métal-céramique avec les résines auto-polymérisantes destinées au collage indirect des boîtiers orthodontiques n'a pas été évaluée à ce jour et un protocole clinique basé sur la littérature scientifique est inexistant. Objectifs : 1) Comparer la force de cisaillement maximale entre des boîtiers métalliques et des surfaces en porcelaine préparées selon différentes méthodes; 2) Suggérer un protocole clinique efficace et prévisible. Matériel et méthodes : Quatre-vingt-dix disques en leucite (6 groupes; n = 15/groupe) ont été préparés selon 6 combinaisons de traitements de surface : mécaniques (+ / - fraisage pour créer les rugosités) et chimiques (acide fluorhydrique, apprêt, silane). Des bases en résine composite Transbond XT (3M Unitek, Monrovia, California) faites sur mesure ont été collées avec le système de résine adhésive auto-polymérisante Sondhi A + B Rapid Set (3M Unitek, Monrovia, California). Les échantillons ont été préservés (H2O/24hrs), thermocyclés (500 cycles) et testés en cisaillement (Instron, Norwood, Massachusetts). Des mesures d’Index d’adhésif résiduel (IAR) ont été compilées. Des tests ANOVAs ont été réalisés sur les rangs étant donné que les données suivaient une distribution anormale et ont été ajustés selon Tukey. Un Kruskall-Wallis, U-Mann Whitney par comparaison pairée et une analyse de Weibull ont aussi été réalisés. Résultats : Les médianes des groupes varient entre 17.0 MPa (- fraisage + acide fluorhydrique) à 26.7 MPa (- fraisage + acide fluorhydrique + silane). Le fraisage en surface ne semble pas affecter l’adhésion. La combinaison chimique (- fraisage + silane + apprêt) a démontré des forces de cisaillement significativement plus élevées que le traitement avec (- fraisage + acide fluorhydrique), p<0,05, tout en possédant des forces similaires au protocole typiquement suggéré à l’acide fluorhydrique suivi d’une application de silane, l’équivalence de (- fraisage + acide fluorhydrique + silane). Les mesures d’IAR sont significativement plus basses dans le groupe (- fraisage + acide fluorhydrique) en comparaison avec celles des 5 autres groupes, avec p<0,05. Malheureusement, ces 5 groupes ont des taux de fracture élévés de 80 à 100% suite à la décimentation des boîtiers. Conclusion : Toutes les combinaisons de traitement de surface testées offrent une force d’adhésion cliniquement suffisante pour accomplir les mouvements dentaires en orthodontie. Une application de silane suivie d’un apprêt est forte intéressante, car elle est simple à appliquer cliniquement tout en permettant une excellente adhésion. Il faut cependant avertir les patients qu’il y a un risque de fracture des restorations en céramique lorsque vient le moment d’enlever les broches. Si la priorité est de diminuer le risque d’endommager la porcelaine, un mordançage seul à l’acide hydrofluorique sera suffisant.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Les brosses de polyélectrolytes font l’objet d’une attention particulière pour de nombreuses applications car elles présentent la capacité de changer de conformation et, par conséquent, de propriétés de surface en réponse aux conditions environnementales appliquées. Le contrôle des principaux paramètres de ces brosses telles que l'épaisseur, la composition et l'architecture macromoléculaire, est essentiel pour obtenir des polymères greffés bien définis. Ceci est possible avec la Polymérisation Radicalaire par Transfert d’Atomes - Initiée à partir de la Surface (PRTA-IS), qui permet la synthèse de brosses polymériques de manière contrôlée à partir d’une couche d'amorceurs immobilisés de manière covalente sur une surface. Le premier exemple d’une synthèse directe de brosses de poly(acide acrylique) (PAA) par polymérisation radicalaire dans l’eau a été démontré. Par greffage d’un marqueur fluorescent aux brosses de PAA et via l’utilisation de la microscopie de fluorescence par réflexion totale interne, le dégreffage du PAA en temps réel a pu être investigué. Des conditions environnementales de pH ≥ 9,5 en présence de sel, se sont avérées critiques pour la stabilité de la liaison substrat-amorceur, conduisant au dégreffage du polymère. Afin de protéger de l’hydrolyse cette liaison substrat-amorceur sensible et prévenir le dégreffage non souhaité du polymère, un espaceur hydrophobique de polystyrène (PS) a été inséré entre l'amorceur et le bloc de PAA stimuli-répondant. Les brosses de PS-PAA obtenues étaient stables pour des conditions extrêmes de pH et de force ionique. La réponse de ces brosses de copolymère bloc a été étudiée in situ par ellipsométrie, et le changement réversible de conformation collapsée à étirée, induit par les variations de pH a été démontré. De plus, des différences de conformation provenant des interactions du bloc de PAA avec des ions métalliques de valence variable ont été obtenues. Le copolymère bloc étudié semble donc prometteur pour la conception de matériaux répondant rapidement a divers stimuli. Par la suite, il a été démontré qu’un acide phosphonique pouvait être employé en tant qu’ amorceur PRTA-IS comme alternative aux organosilanes. Cet amorceur phosphonate a été greffé pour la première fois avec succès sur des substrats de silice et une PRTA-IS en milieux aqueux a permis la synthèse de brosses de PAA et de poly(sulfopropyl méthacrylate). La résistance accrue à l’hydrolyse de la liaison Sisubstrat-O- Pamorceur a été confirmée pour une large gamme de pH 7,5 à 10,5 et a permis l’étude des propriétés de friction des brosses de PAA sous différentes conditions expérimentales par mesure de forces de surface. Malgré la stabilité des brosses de PAA à haute charge appliquée, les études des propriétés de friction ne révèlent pas de changement significatif du coefficient de friction en fonction du pH et de la force ionique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The current trend toward minimal-invasive dentistry has introduced innovative techniques for cavity preparation. Chemical vapor deposition (CVD) and laser-irradiation technology have been employed as an alternative to the common use of regular burs in high-speed turbines. Objectives. The purpose of this study was to assess the influence of alternative techniques for cavity preparation on the bonding effectiveness of different adhesives to dentin, and to evaluate the morphological characteristics of dentin prepared with those techniques. Methods. One etch&rinse adhesive (OptiBond FL, Kerr) and three self-etch systems (Adper Prompt L-Pop, 3M ESPE; Clearfil SE Bond, Kuraray; Clearfil S3 Bond, Kuraray) were applied on dentin prepared with a regular bur in a turbine, with a CVD bur in a turbine, with a CVD tip in ultrasound and with an ErCr:YSGG laser. The micro-tensile bond strength (mu TBS) was determined after storage in water for 24 h at 37 degrees C, and morphological evaluation was performed by means of field -emission -gun scanning electron microscopy (Feg-SEM). Results. Feg-SEM evaluation revealed different morphological features on the dentin surface after the usage of both the conventional and alternative techniques for cavity preparation, more specifically regarding smear-layer thickness and surface roughness. CVD bur-cut, CVD ultra-sonoabraded and laser-irradiated dentin resulted in lower mu TBSs than conventionally bur-cut dentin, irrespective of the adhesive employed. Significance. The techniques, such as CVD diamond-bur cutting, CVD diamond ultra-sonoabrasion and laser-irradiation, used for cavity preparation may affect the bonding effectiveness of adhesives to dentin, irrespective of their acidity or approach. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Internal residual stresses significantly influence the fatigue strength of coated materials. It is well known that chromium plating is the most used electrodeposited coating for important industrial applications. However, pressure to identify alternatives or to improve the chromium electroplating process have increased in recent years, related to the reduction in fatigue strength of the base material and to environmental requirements. The high efficiency and fluoride free hard chromium electroplating there called accelerated) is an improvement to the conventional process. One environmentally safer and cleaner alternative to hard chromium plating is tungsten carbide thermal spray coating applied by the High Velocity Oxy-Fuel (HVOF) process. To increase the fatigue strength of chromium plated materials, coating thickness and microcracks density are important parameters to be controlled. Techniques as compressive residual stresses induced by shot peening and multilayers, are also used. The aim of this study was to analyse the effects on AISI 4340 steel, in the rotating bending fatigue behaviour, of the: tungsten carbide thermal spray coating applied by HP/HVOF process; chemical nickel underplate, and shot peening process applied before coating deposition, in comparison to hard chromium electroplatings. Rotating bending fatigue test results indicate better performance for the conventional hard chromium plating in relation to the accelerated hard chromium electroplating. Tungsten carbide thermal spray coating and accelerated hard chromium plate over nickel resulted in higher fatigue strength when compared to samples conventional or accelerated hard chromium plated. Shot peening showed to be an excellent alternative to increase fatigue strength of AISI 4340 steel hard chromium electroplated. (C) 2001 Elsevier B.V. Ltd. All rights reserved.