974 resultados para supported liquid membranes
Resumo:
Supported ionic liquid membranes (SILMs) has the potential to be a new technological platform for gas/organic vapour separation because of the unique non-volatile nature and discriminating gas dissolution properties of room temperature ionic liquids (ILs). This work starts with an examination of gas dissolution and transport properties in bulk imidazulium cation based ionic liquids [Cnmim][NTf2] (n = 2.4, 6, 8.10) from simple gas H2, N2, to polar CO2, and C2H6, leading to a further analysis of how gas dissolution and diffusion are influenced by molecular specific gas-SILMs interactions, reflected by differences in gas dissolution enthalpy and entropy. These effects were elucidated again during gas permeation studies by examining how changes in these properties and molecular specific interactions work together to cause deviations from conventional solution–diffusion theory and their impact on some remarkably contrasting gas perm-selectivity performance. The experimental perm-selectivity for all tested gases showed varied and contrasting deviation from the solution–diffusion, depending on specific gas-IL combinations. It transpires permeation for simpler non-polar gases (H2, N2) is diffusion controlled, but strong molecular specific gas-ILs interactions led to a different permeation and selectivity performance for C2H6 and CO2. With exothermic dissolution enthalpy and large order disruptive entropy, C2H6 displayed the fastest permeation rate at increased gas phase pressure in spite of its smallest diffusivity among the tested gases. The C2H6 gas molecules “peg” on the side alkyl chain on the imidazulium cation at low concentration, and are well dispersed in the ionic liquids phase at high concentration. On the other hand strong CO2-ILs affinity resulted in a more prolonged “residence time” for the gas molecule, typified by reversed CO2/N2 selectivity and slowest CO2 transport despite CO2 possess the highest solubility and comparable diffusivity in the ionic liquids. The unique transport and dissolution behaviour of CO2 are further exploited by examining the residing state of CO2 molecules in the ionic liquid phase, which leads to a hypothesis of a condensing and holding capacity of ILs towards CO2, which provide an explanation to slower CO2 transport through the SILMs. The pressure related exponential increase in permeations rate is also analysed which suggests a typical concentration dependent diffusion rate at high gas concentration under increased gas feed pressure. Finally the strong influence of discriminating and molecular specific gas-ILs interactions on gas perm-selectivity performance points to future specific design of ionic liquids for targeted gas separations.
Resumo:
Supported liquid phase catalyst (SLPC) is one of effectively heterogenized homogeneous catalysts using organometallic complexes as active components, which are dissolved in a small quantity of liquid phase dispersed in the form of isle or film on the surface of supports. The SLPC has successfully been applied for several chemical transformations and this article will review recent results with respect to the preparation and catalytic performance, the applicability to continuous flow operations, and the capability of multifunctional catalysis.
Resumo:
As a kind of supported bilayer lipid membranes, hybrid bilayer membrane (HBM) was applied to the interaction between Ca2+ and lipid for the first time. By using Fe(CN)(6)(3-) as a probe, we found that Ca2+ could induce the ion channel of HBM to be in open state. STM images study proved this phenomenon.
Resumo:
Supported lipid membranes consisting of self-assembled alkanethiol and lipid monolayers on gold substrates could be produced by three different deposition methods: the Langmuir-Blodgett (L-B) technique, the painted method, and the paint-freeze method, By using cyclic voltammetry, chronoamperometry/chronocoulometry and a.c. impedance measurements, we demonstrated that lipid membranes prepared by these three deposition methods had obvious differences in specific capacitance, resistance and thickness. The specific capacitance of lipid membranes prepared by depositing an L-B monolayer on the alkanethiol alkylated surfaces was 0.53 mu Fcm(-2), 0.44 mu Fcm(-2) by the painted method and 0.68 mu Fcm(-2) by the paint-freeze method. The specific conductivity of lipid membranes prepared by the L-B method was over three times lower than that of the painted lipid membranes, while that of the paint-freeze method was the lowest. The difference among the three types of lipid membranes was ascribed to the influence of the organic solvent in lipid films and the changes in density of the films. The lipid membranes prepared by the usual painted method contained a trace amount of the organic solvent. The organic solvent existing in the hydrocarbon core of the membrane reduced the density of the membrane and increased the thickness of the membrane. The membrane prepared by depositing an L-B monolayer containing no solvent had higher density and the lowest fluidity, and the thickness of the membrane was smaller. The lipid membrane prepared by the paint-freeze method changed its structure sharply at the lower temperature. The organic solvent was frozen out of the membrane while the density of the membrane increased greatly. All these caused the membrane to exist in a ''tilted'' state and the thickness of this membrane was the smallest. The lipid membrane produced by the paint-freeze method was a membrane not containing organic solvent. This method was easier in manipulation and had better reproducibility than that of the usual painting method and the method of forming free-standing lipid film. The solvent-free membrane had a long lifetime and a higher mechanical stability. This model membrane would be useful in many areas of scientific research.
Resumo:
PVC supported liquid membrane and carbon paste potentiometric sensors incorporating an Mn(III)-porphyrin complex as a neutral host molecule were developed for the determination of paracetamol. The measurements were carried out in solution at pH 5.5. Under such conditions paracetamol exists as a neutral molecule. The mechanism of molecular recognition between the Mn(III)-porphyrin and paracetamol, leading to potentiometric signal generation, is discussed.The sensitivity and selectivity toward paracetamol of carbon paste and polymeric liquid membrane electrodes incorporating an Mn(III)-porphyrin host were compared. The applicability of these sensors to the direct determination of paracetamol was checked by performing a recovery test in human plasma.
Resumo:
In this work, the effect of the substrate microstructure on the formation of SnO2 membranes and of the sintering conditions on their porosity have been analysed. Samples have been prepared by colloidal suspensions cast on alumina or kaolin substrates. Supported membranes have been characterized by Hg porosimetry, MEV, XRD and N-2 adsorption-desorption isotherms. The results show that the narrower pore size distribution of alumina substrate allowed to prepare membranes more homogeneous and free of cracks than that supported on kaolin. The crystallite and pore sizes of the membranes could be controlled by adjusting the temperature of sintering, allowing materials with adequate microstructure with application for ultrafiltration process.
Resumo:
Application of electric fields tangent to the plane of a confined patch of fluid bilayer membrane can create lateral concentration gradients of the lipids. A thermodynamic model of this steady-state behavior is developed for binary systems and tested with experiments in supported lipid bilayers. The model uses Flory’s approximation for the entropy of mixing and allows for effects arising when the components have different molecular areas. In the special case of equal area molecules the concentration gradient reduces to a Fermi–Dirac distribution. The theory is extended to include effects from charged molecules in the membrane. Calculations show that surface charge on the supporting substrate substantially screens electrostatic interactions within the membrane. It also is shown that concentration profiles can be affected by other intermolecular interactions such as clustering. Qualitative agreement with this prediction is provided by comparing phosphatidylserine- and cardiolipin-containing membranes.
Resumo:
The chemical contamination of natural waters is a global problem with a worldwide impact. Considering the relevance of this problem, this thesis is intended, on one hand, to develop different separation/preconcentration techniques based on membranes ability to permeate anions for the transport of toxic oxyanions of chromium(VI) and arsenic contained in aqueous matrices. In particular, we have investigated supported liquid membranes and polymer inclusion membranes, both of which contain the commercial quaternary ammonium salt Aliquat 336 as a carrier, as well as commercial anion exchange membranes. On the other hand, we have focused on the development of chemical sensors to facilitate the monitoring of several metals from different aqueous matrices. Thus, a selective optical sensor for Cr(VI) based on polymeric membranes containing Aliquat 336 as an ionophore has been designed. Additionally, mercury-based screen-printed electrodes have been evaluated for for cadmium, lead, copper and zinc detection.
Resumo:
Amphotericin B (AmB) is a popular drug frequently applied in the treatment of systemic fungal infections. In the presence of ruthenium (II) as the maker ion, the behavior of AmB to form ion channels in sterol-free and cholesterol- or ergosterol-containing supported phosphatidylcholine bilayer model membranes were studied by cyclic votammetry, AC impedance spectroscopy, and UV/visible absorbance spectroscopy. Different concentrations of AmB ranging from a molecularly dispersed to a highly aggregated state of the drug were investigated. In a fixed cholesterol or ergosterol content (5 mol %) in glassy carbon electrode-supported model membranes, our results showed that no matter what form of AmB, monomeric or aggregated, AmB could form ion channels in supported ergosterol-containing phosphatidylcholine bilayer model membranes. However, AmB could not form ion channels in its monomeric form in sterol-free and cholesterol-containing supported model membranes. On the one hand, when AmB is present as an aggregated state, it can form ion channels in cholesterol-containing supported model membranes; on the other hand, only when AmB is present as a relatively highly aggregated state can it form ion channels in sterol-free supported phosphatidylcholine bilayer model membranes. The results showed that the state of AmB played an important role in forming ion channels in sterol-free and cholesterol-containing supported phosphatidylcholine bilayer model membranes.
Resumo:
El glifosat, N-(fosfonometil) glicina, és un dels herbicides més utilitzats arreu del món a causa de la seva baixa toxicitat i al seu ampli espectre d'aplicació. A conseqüència del gran ús que se'n fa, és necessari monitoritzar aquest compost i el seu principal metabòlit, l'àcid aminometilfosfònic (AMPA), en el medi ambient. S'han descrit diversos mètodes instrumentals basats en cromatografia de gasos (GC) i de líquids (HPLC), sent aquesta darrera l'opció més favorable a causa del caràcter polar dels anàlits. Per assolir nivells de concentració baixos cal, però, la preconcentració dels anàlits. En aquest treball s'estudien diferents alternatives amb aquest objectiu. S'ha avaluat la tècnica de membrana líquida suportada (SLM) on la membrana consisteix en una dissolució orgànica, que conté un transportador (en el nostre cas, un bescanviador d'anions comercial, Aliquat 336), que impregna un suport polimèric microporós que se situa entre dues solucions aquoses: la de càrrega, que conté els anàlits inicialment, i la receptora, on es retenen els anàlits després del seu transport a través de la membrana. Les condicions d'extracció més adequades s'obtenen treballant en medi bàsic amb NaOH on els anàlits estan en forma aniònica i les majors recuperacions s'obtenen amb HCl 0,1 M o NaCl 0,5 M, la qual cosa indica que l'ió clorur és la força impulsora del transport. Un cop dissenyat el sistema, es duen a terme experiments de preconcentració amb dues geometries diferents: un sistema de membrana laminar (LSLM) on recircula la fase receptora i un sistema de fibra buida (HFSLM). Els millors resultats s'obtenen amb el mòdul de fibra buida, amb factors de concentració de 25 i 3 per a glifosat i AMPA, respectivament, fent recircular durant 24 hores 100 ml de solució de càrrega i 4 ml de solució receptora. També s'aplica una tècnica més selectiva, la cromatografia d'afinitat amb ió metàl·lic immobilitzat (IMAC), basada en la interacció entre els anàlits i un metall immobilitzat en una resina a través d'un grup funcional d'aquesta. En aquest estudi s'immobilitza pal·ladi al grup funcional 8-hidroxiquinoleïna de la resina amb matriu acrílica Spheron Oxine 1000 i s'avalua per a l'extracció i preconcentració de glifosat i AMPA. Per a ambdós anàlits l'adsorció és del 100 % i les recuperacions són superiors al 80 % i al 60 % per a glifosat i AMPA, respectivament, utilitzant HCl 0,1 M + NaCl 1 M com a eluent. Aquests resultats es comparen amb els obtinguts amb dues resines més, també carregades amb pal·ladi: Iontosorb Oxin 100, que té el mateix grup funcional però matriu de cel·lulosa, i Spheron Thiol 1000, on el grup funcional és un tiol i la matriu també és acrílica. Per al glifosat els resultats són similars amb totes les resines, però per a l'AMPA la resina Spheron Thiol és la única que proporciona recuperacions superiors al 93 %. Finalment, una altra opció estudiada és l'acoblament de dues columnes de cromatografia líquida (LC-LC). En l'estudi l'objectiu és millorar el mètode existent per a glifosat i AMPA en aigües naturals on el LOD era de 0,25 ug/l. El mètode consisteix en la derivatització precolumna amb el reactiu fluorescent FMOC i l'anàlisi amb l'acoblament LC-LC-fluorescència. Variant lleugerament les condicions de derivatització s'aconsegueix quantificar 0,1 ug/l de glifosat i AMPA. Es fortifiquen aigües naturals amb 0,1, 1 i 10 ug/l dels anàlits per validar el mètode. S'obtenen recuperacions d'entre el 85 % i el 100 %, amb desviacions estàndard relatives inferiors al 8 %. Aplicant una tècnica de preconcentració prèvia a la derivatització i anàlisi utilitzant una resina de bescanvi aniònic, Amberlite IRA-900, es millora la sensibilitat del mètode i s'assoleix un LOD per al glifosat de 0,02 ug/l.