975 resultados para subsurface drip
Resumo:
The velocity of dripline flushing in subsurface drip irrigation (SDI) systems affects system design, cost, management, performance, and longevity. A 30‐day field study was conducted at Kansas State University to analyze the effect of four targeted flushing velocities (0.23, 0.30, 0.46, and 0.61 m/s) for a fixed 15 min duration of flushing and three flushing frequencies (no flushing or flushing every 15 or 30 days) on SDI emitter discharge and sediments within the dripline and removed in the flushing water. At the end of the field experiment (371 h), the amount of solids carried away by the flushing water and retained in every lateral were determined as well as laboratory determination of emitter discharge for every single emitter within each dripline. Greater dripline flushing velocities, which also resulted in greater flushing volumes, tended to result in greater amounts of solids in the flushing water, but the differences were not always statistically significant. Neither the frequency of flushing nor the interaction of flushing frequency and velocity significantly affected the amount of solids in the flushing water. There was a greater concentration of solids in the beginning one‐third of the 90 m laterals, particularly for treatments with no flushing or with slower dripline flushing velocities. As flushing velocity and concurrently flushing volume increased, there was a tendency for greater solids removal and/or more equal distribution within the dripline. At the end of the field study, the average emitter discharge as measured in the laboratory for a total of 3970 emitters was 0.64 L/h. which was significantly less (approximately 2.5%) than the discharge for new and unused emitters. Only six emitters were nearly or fully clogged, with discharges between 0% and 5% of new and unused emitters. Flushing velocity and flushing frequency did not have consistent significant effects on emitter discharge, and those numerical differences that did exist were small (<3%). Emitter discharge was approximately 3% less for the distal ends of the driplines (last 20% of the dripline). Although not a specific factor in the study, the results of solids removals during flushing and solids retention within the different dripline sections suggest that duration of flushing may be a more cost‐effective management option than increasing the dripline flushing velocity through SDI system design. Finally, although microirrigation system components have been improved over the years, the need for flushing to remove solids and reduce clogging potential has not been eliminated
Resumo:
Emitter spacings of 0.3 to 0.6 m are commonly used for subsurface drip irrigation (SDI) of corn on the deep, silt loam soils of the U.S. Great Plains. Subsurface drip irrigation emitter spacings of 0.3, 0.6, 0.9 and 1.2 m were examined for the resulting differences in soil water redistribution, corn grain yield, yield components, seasonal water use, and water productivity in a 4‐year field study (2005 through 2008) at the Kansas State University Northwest Research‐Extension Center, Colby, Kansas. The results indicate that there is increased preferential water movement along the dripline (parallel) as compared to perpendicular to the dripline and that this phenomenon partially compensates for wider emitter spacings in terms of soil water redistribution. Corn yield and water productivity (WP) were not significantly affected by the emitter spacing with application of a full irrigation regime
Resumo:
Irrigation with domestic sewage effluent (DSE) has been recommended by subsurface dripping, as it can obtain a high rate of irrigation efficiency and faster use of salts in comparison with other irrigation methods. The study aimed at evaluating the area, the length and the effective depth of the root system of sugarcane irrigated with DSE by subsurface drip system and with different irrigation rates at depths of 0.00-0.20, 0.20-0.40, 0.40-0.60 and 0.60-0.80m. The experiment was carried out in the municipality of Piracicaba, in the state of São Paulo (SP), Brazil, in a sugarcane area irrigated with DSE in a completely randomized blocks set up in furrows, with three replications and four treatments, which are: one area without irrigation (AWI) and three irrigated areas meeting 50% (T50%), 100% (T100%) and 200% (T200%) of the crop's water need between each round of irrigation. T100% and T200% provided smaller areas and lengths of roots in the two deepest layers, as compared to AWI and T50%, which stimulated the development of deeper roots due to the water stress. TWI, T100% and T200% presented 80% of the roots up to a depth of 0.40m and T50% treatment presented 76.43% of roots total.
Resumo:
The use of treated sewage effluent (TSE) combined with the subsurface drip irrigation (SDI) method in agriculture can decrease the costs of agricultural production, in attempts to fertigate crops more efficiently. In this study it was compared the dimensions of the wet bulb formed by the application of TSE and municipal water supply (MWS) in an Oxisoil. We have evaluated the effect of water quality and discharge between drippers used in sugarcane crop. Three trenches were opened and 21 three-rod TDR probes were setup in a mesh and a dripper was buried at 0.30 m, for each constant discharge of 1.0 L h-1and 1.6 L h-1. Comparing results from different wetted soil profiles it was observed that the vertical and horizontal dimensions of the wet bulb are similar for both MWS and TSE, being peculiars according to the discharges used and volume applied. Regardless the water quality, an increase of 60% in discharge decreased the deepest infiltration.
Resumo:
Emitter spacings of 0.3 to 0.6 m are commonly used for subsurface drip irrigation (SDI) of corn on the deep, silt loam soils of the U.S. Great Plains. Subsurface drip irrigation emitter spacings of 0.3, 0.6, 0.9 and 1.2 m were examined for the resulting differences in soil water redistribution, corn grain yield, yield components, seasonal water use, and water productivity in a 4‐year field study (2005 through 2008) at the Kansas State University Northwest Research‐Extension Center, Colby, Kansas. The results indicate that there is increased preferential water movement along the dripline (parallel) as compared to perpendicular to the dripline and that this phenomenon partially compensates for wider emitter spacings in terms of soil water redistribution. Corn yield and water productivity (WP) were not significantly affected by the emitter spacing with application of a full irrigation regime
Resumo:
Subsurface drip irrigation that uses an emitter protection system to avoid its clogging by roots and soil particles may be viable compared to a conventional system. The objective of this work was to evaluate the performance of a system with emitter protection, and to compare the results with a system that uses a conventional emitter for subsurface drip irrigation. In the system with protection an inexpensive materials polyethylene hose, microtube, connector, and a dripper to control the flow rate were used; and, in the conventional system a commercial emitter was used. After 12 months of evaluation, the system with protector showed good performance, with relative average flow rate of 0.97 and 0.98 in pots with and without crop, respectively, showing no clogging problems and lower cost. In conventional system relative flow rate of 0.51 and 0.98 were observed in pots with and without crop, respectively, also clogging degree by roots of 49.22%, and emitters with soil inside was observed. Thus, the use of emitter with protection presented feasibility for subsurface drip irrigation, under conditions used in this research.
Resumo:
The current research aims to analyse theoretically and evaluate a self-manufactured simple design for subsurface drip irrigation (SDI) emitter to avoid root and soil intrusion. It was composed of three concentric cylindrical elements: an elastic silicone membrane; a polyethylene tube with two holes drilled on its wall for water discharge; and a vinyl polychloride protector system to wrap the other elements. The discharge of the emitter depends on the change in the membrane diameter when it is deformed by the water pressure. The study of the operation of this emitter is a new approach that considers mechanical and hydraulic principles. Thus, the estimation on the membrane deformation was based on classical mechanical stress theories in composite cylinders. The hydraulic principles considered the solid deformation due to force based on water pressure and the general Darcy–Weisbach head-loss equation. Twenty emitter units, with the selected design, were handcrafted in a lathe and were used in this study. The measured pressure/discharge relationship for the emitters showed good agreement with that calculated by the theoretical approach. The variation coefficient of the handcrafted emitters was high compared to commercial emitters. Results from field evaluations showed variable values for the relative flow variation, water emission uniformity and relative flow rate coefficients, but no emitter was obstructed. Therefore, the current emitter design could be suitable for SDI following further studies to develop a final prototype.
Resumo:
Se muestra los resultados de un studio con modelos de goteros enterrados donde se observa un efecto de autoreegulación del efecto de sobrepresión del agua en el suelo.
Resumo:
The aim of this study was to compare the use of water and nitrogen on ratoon sugarcane during irrigated and rain-fed conditions, and to assess the production potential of stalks and sugar with different rates of N-fertilizer on the subsurface drip-irrigated management. The experimental design was a randomized block with four replications for each experiment and treatments: (T1) irrigated, 0kg N ha-1; (T2) irrigated, 70kg N ha-1; (T3) irrigated, 140kg N ha-1; (T4) irrigated, 210kg N ha-1; (T5) not irrigated, 0kg N ha-1, and (T6) not irrigated, 140kg N ha-1. Biometric, technological, dry matter and yield variables were analyzed among the treatments. The irrigation system together with the application of N-fertilizer at 140kg ha-1 presented significant differences in dry matter accumulation of shoots, and for the production of stalks and sugar, respectively 94, 105 and 106%, higher when compared to the not irrigated, without N-fertilizer (T5). There was a positive and synergistic effect of irrigation with N-fertilizer on the productivity of stalks and sugar. Ratoon sugarcane irrigated with subsurface dripping had the highest yield (22Mg ha-1 of sugar) with the dosage of 140kg ha-1 N.
Resumo:
The aim of this study was to compare the use of water and nitrogen on ratoon sugarcane during irrigated and rain-fed conditions, and to assess the production potential of stalks and sugar with different rates of N-fertilizer on the subsurface drip-irrigated management. The experimental design was a randomized block with four replications for each experiment and treatments: (T1) irrigated, 0kg N ha-1; (T2) irrigated, 70kg N ha-1; (T3) irrigated, 140kg N ha-1; (T4) irrigated, 210kg N ha-1; (T5) not irrigated, 0kg N ha-1, and (T6) not irrigated, 140kg N ha-1. Biometric, technological, dry matter and yield variables were analyzed among the treatments. The irrigation system together with the application of N-fertilizer at 140kg ha-1 presented significant differences in dry matter accumulation of shoots, and for the production of stalks and sugar, respectively 94, 105 and 106%, higher when compared to the not irrigated, without N-fertilizer (T5). There was a positive and synergistic effect of irrigation with N-fertilizer on the productivity of stalks and sugar. Ratoon sugarcane irrigated with subsurface dripping had the highest yield (22Mg ha-1 of sugar) with the dosage of 140kg ha-1 N.
Resumo:
A trial was carried out to evaluate the chemical composition in the aerial part of lettuce, cv. 'Elisa', irrigated with wastewater treated with constructed wetland and source deposit water, grown on a Rhodic Hapludox Soil, using the irrigation systems sprinkle, subsurface drip and surface drip irrigation. The experiment was carried out from August 17th to October 3rd of 2001 and the chemical analyses of the lettuce were accomplished to 47 days after transplanting of the seedling. The aerial part of the lettuce was analyzed as for the levels of total nitrogen, nitrate, phosphorus, potassium, calcium, magnesium, sulfur, iron, manganese, copper, zinc, sodium, boron, cobalt and molybdenum. The sodium and the sulfur presented higher levels than the maximum suitable in the aerial part of the lettuce and the smallest level of magnesium, while other chemical elements analyzed were normal and appropriate considering the standard for well-nourished plants, not being influenced by the water type. The sodium was the chemical element that presented the highest levels in the aerial part of the lettuce in the treatments irrigated with wastewater, presenting significant difference in relationship to the treatments irrigated with source deposit water in the three irrigation systems. The use of the different irrigation systems by the application of wastewater treated with constructed wetland did not interfere in the levels of nutrients in the aerial part of the lettuce.
Resumo:
Flushing is an important maintenance task that removes accumulated particles in microirrigation laterals that can help to reduce clogging problems. The effect of three dripline flushing frequency treatments (no flushing, one flushing at the end of each irrigation period, and a monthly flushing during the irrigation period) was studied in surface and subsurface drip irrigation systems that operated using a wastewater treatment plant effluent for three irrigation periods of 540 h each. The irrigation systems had two different emitters, one pressure compensating and the other not, both molded and welded onto the interior dripline wall, placed in laterals 87 meters long. Dripline flow of the pressure compensating emitter increased 8% over time, while in the nonpressure compensating emitter, dripline flow increased 25% in the surface driplines and decreased 3% in the subsurface driplines by the emitter clogging. Emitter clogging was affected primarily by the interactions between emitter location, emitter type, and flushing frequency treatment. The number of completely clogged emitters was affected by the interaction between irrigation system and emitter type. There was an average of 3.7% less totally clogged emitters in flushed surface driplines with the pressurecompensating emitter as compared to flushed subsurface laterals with the nonpressure compensating emitter
Resumo:
ABSTRACT For drip irrigation design and management, it is necessary to know the relation between flow and pressure acting on emitters. In the case of subsurface drip irrigation, the backpressure phenomenon may change the hydraulic characteristics of emitters. Thus, this study aimed at determining such relationship between flow and pressure of different driplines in surface and subsurface conditions; aiming to find possible differences in hydraulic behavior. We tested four emitter types; two pressure compensating (D5000 and Hydro PCND) and two non-pressure compensating (TalDrip and Jardiline). Emitter flow rates were attained in atmospheric conditions and submerged in water, in which submergence levels represented backpressure. Assays were performed using inlet pressures of 80, 100, 120, and 150 kPa for the Hydro PCND dripline and 25, 50, 100, and 150 kPa for the other ones; the backpressures were of 0.49, 1.47, 2.45, 4.41 and 6.37 kPa with four replications. The emitters had their proportionality constants and discharge exponents changed in submerged applications, representing backpressure effect. Non-pressure compensating emitters had their discharge exponent decreased, while in pressure compensating ones, it was increased. Backpressure reduced emitter flow rates at all evaluated pressures.
Resumo:
The objective of this work consisted in the study of the fertigation and subsurface drip irrigation in the sugarcane productivity, in the second and the third seasons and technological effects in the growth. The experiment was developed in the experimental area of the Agronomical Sciences Faculty, FCA/UNESP - Botucatu, Brazil. The drip pipe was installed at 30 cm of depth and under the plantation line of sugar cane RB 72454 variety. The fertigation treatment with the biggest dose presented the better yield, with 190.01 t ha(-1) and 168.80 t ha(-1) to the second and the third harvest, respectively. The fertigation did not modify the technological qualities of the sugarcane in the two studied seasons, and the irrigation provided 43.5% and 67.2% of increments in the production of stem, to the second and third cut, respectively.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)