999 resultados para stop-flow lithography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

SUMMARY Regional drug delivery is an approach designed to improve the selectivity of anticancer chemotherapy. The advantage of regional treatments lies in increasing the drug concentration in the affected organ, while the rest of the organism is spared, thus improving efficacy and limiting treatment toxicity. The goal of this thesis was to assess the distribution throughout the body and the disposition (pharmacokinetics) of two anticancer agents, doxorubicin and gemcitabine, administered by two different regional administration modalities: isolated lung perfusion (ILP) for pulmonary metastases from soft tissue sarcomas and abdominal stop-flow hypoxic perfusion for advanced pancreatic cancers, respectively. For this purpose, two high-performance liquid chromatography methods were developed and validated. The first enabled the determination of doxorubicin in four different biological matrices: serum, reconstituted effluent, tissues with low levels of doxorubicin and tissues with high levels of doxorubicin. The second allows the analysis of gemcitabine and its principal metabolite dFdU in plasma. The administration of doxorubicin by ILP was studied in three preclinical studies (one on pigs and two on rats). It was first shown that, regardless of the administration mode, doxorubicin was not homogeneously distributed throughout the lung and that some regions remained out of reach. Secondly, it was demonstrated that doxorubicin did not adequately reach the tumours despite very high levels found in the lung. Finally, an attempt to enhance the doxorubicin tumoural uptake by pharmacologic modulation using two P-glycoprotein inhibitors, cyclosporin and valspodar, was unsuccessful. The last part of this work involves the administration of gemcitabine by abdominal stop-flow as a part of a phase I clinical trial in patients with advanced pancreatic disease or resistant malignant ascites. The study has demonstrated that the regional exposure to gemcitabine was increased while the exposure of the entire organism was similar to standard intravenous administrations. From a toxicological perspective, the procedure was rather well tolerated. However, even if no clinical response is expected from a phase I study, no hints of clinical responses were unfortunately observed. In conclusion, even if loco-regional therapies may afford the pharmacological advantage of increasing anticancer drug levels at the tumour site, further studies of these investigational treatment modalities are warranted to ascertain whether they can provide a significant improvement of the cancer therapy for patients, in terms of treatment tolerability, improved responses and survival rates. RÉSUMÉ L'administration locorégionale d'agents anticancéreux est une approche destinée à augmenter la sélectivité du traitement. L'avantage des traitements régionaux repose sur le fait que la concentration du médicament cytostatique est augmentée dans l'organe où est localisée la tumeur, alors que le reste de l'organisme est épargné, améliorant ainsi en théorie l'efficacité du traitement et en limitant sa toxicité. Le but de ce travail de thèse avait pour objectif de préciser, la pharmacocinétique au sein de l'organisme de deux agents anticancéreux, la doxorubicine et la gemcitabine, administrés par deux types de perfusions loco-régionales: la perfusion isolée du poumon (ILP) pour les métastases pulmonaires de sarcomes des tissus mous, et la perfusion hypoxique (stop-flow) abdominale pour les cancers avancés du pancréas. Dans cette optique, deux méthodes de chromatographie liquide à haute performance ont été développées et validées. La première permet le dosage de la doxorubicine dans quatre milieux biologiques: le sérum, l'effluent reconstitué, ainsi que des tissus contenant des concentrations faibles et élevées en doxorubicine. La seconde méthode permet le dosage dans le plasma de la gemcitabine et de son principal métabolite, le dFdU. L'administration de doxorubicine par ILP a été étudiée dans trois études précliniques (une chez le porc et deux chez le rat). Il a été montré, dans un premier temps, que la doxorubicine n'était pas distribuée de façon homogène au sein du poumon, quel que soit son mode d'administration. Dans un deuxième temps, il a été démontré que le médicament n'atteignait pas les tumeurs de façon adéquate, malgré des concentrations très élevées au sein du tissu pulmonaire. Finalement, une tentative d'augmenter la pénétration tumorale de la doxorubicine par une modulation pharmacologique de la P-glycoprotéine en utilisant la cyclosporine et le valspodar n'a pas abouti. La dernière partie de ce travail concernait l'administration de gemcitabine par stop-flow abdominal dans le cadre d'une étude clinique de phase I menée auprès de patients atteints de cancers avancés du pancréas ou d'ascites malignes réfractaires. Cette étude a démontré que l'exposition régionale à la gemcitabine était augmentée, alors que l'exposition de l'organisme était similaire à une administration de dose standard par voie intraveineuse. D'un point de vue toxicologique la procédure fut relativement bien tolérée. Cependant, même s'il n'est pas attendu de réponses cliniques dans une étude de phase I, aucun signe de réponse au traitement n'a pu être malheureusement observé. En conclusion, même si les thérapies loco-régionales présentent -en théorie- l'avantage pharmacologique d'augmenter les taux du médicaments anticancéreux sur le site de la tumeur, d'autres études précliniques et cliniques sont nécessaires pour démontrer que ces nouvelles modalités de traitement, de nature investigationelle à présent, apportent une réelle amélioration pour la prise en charge des patients cancéreux, en terme de tolérance au traitement et de l'augmentation des taux de réponses et de survie.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: As no curative treatment for advanced pancreatic and biliary cancer with malignant ascites exists, new modalities possibly improving the response to available chemotherapies must be explored. This phase I study assesses the feasibility, tolerability and pharmacokinetics of a regional treatment of gemcitabine administered in escalating doses by the stop-flow approach to patients with advanced abdominal malignancies (adenocarcinoma of the pancreas, n = 8, and cholangiocarcinoma of the liver, n = 1). EXPERIMENTAL DESIGN: Gemcitabine at 500, 750 and 1,125 mg/m(2) was administered to three patients at each dose level by loco-regional chemotherapy, using hypoxic abdominal stop-flow perfusion. This was achieved by an aorto-caval occlusion by balloon catheters connected to an extracorporeal circuit. Gemcitabine and its main metabolite 2',2'-difluorodeoxyuridine (dFdU) concentrations were measured by high performance liquid chromatography with UV detection in the extracorporeal circuit during the 20 min of stop-flow perfusion, and in peripheral plasma for 420 min. Blood gases were monitored during the stop-flow perfusion and hypoxia was considered stringent if two of the following endpoints were met: pH </= 7.2, pO(2) nadir ratio </=0.70 or pCO(2) peak ratio >/=1.35. The tolerability of this procedure was also assessed. RESULTS: Stringent hypoxia was achieved in four patients. Very high levels of gemcitabine were rapidly reached in the extracorporeal circuit during the 20 min of stop-flow perfusion, with C (max) levels in the abdominal circuit of 246 (+/-37%), 2,039 (+/-77%) and 4,780 (+/-7.3%) mug/ml for the three dose levels 500, 750 and 1,125 mg/m(2), respectively. These C (max) were between 13 (+/-51%) and 290 (+/-12%) times higher than those measured in the peripheral plasma. Similarly, the abdominal exposure to gemcitabine, calculated as AUC(t0-20), was between 5.5 (+/-43%) and 200 (+/-66%)-fold higher than the systemic exposure. Loco-regional exposure to gemcitabine was statistically higher in presence of stringent hypoxia (P < 0.01 for C (max) and AUC(t0-20), both normalised to the gemcitabine dose). Toxicities were acceptable considering the complexity of the procedure and were mostly hepatic; it was not possible to differentiate the respective contributions of systemic and regional exposures. A significant correlation (P < 0.05) was found between systemic C (max) of gemcitabine and the nadir of both leucocytes and neutrophils. CONCLUSIONS: Regional exposure to gemcitabine-the current standard drug for advanced adenocarcinoma of the pancreas-can be markedly enhanced using an optimised hypoxic stop-flow perfusion technique, with acceptable toxicities up to a dose of 1,125 mg/m(2). However, the activity of gemcitabine under hypoxic conditions is not as firmly established as that of other drugs such as mitomycin C, melphalan or tirapazamine. Further studies of this investigational modality, but with bioreductive drugs, are therefore warranted first to evaluate the tolerance in a phase I study and later on to assess whether it does improve the response to chemotherapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first part of the thesis describes a new patterning technique--microfluidic contact printing--that combines several of the desirable aspects of microcontact printing and microfluidic patterning and addresses some of their important limitations through the integration of a track-etched polycarbonate (PCTE) membrane. Using this technique, biomolecules (e.g., peptides, polysaccharides, and proteins) were printed in high fidelity on a receptor modified polyacrylamide hydrogel substrate. The patterns obtained can be controlled through modifications of channel design and secondary programming via selective membrane wetting. The protocols support the printing of multiple reagents without registration steps and fast recycle times. The second part describes a non-enzymatic, isothermal method to discriminate single nucleotide polymorphisms (SNPs). SNP discrimination using alkaline dehybridization has long been neglected because the pH range in which thermodynamic discrimination can be done is quite narrow. We found, however, that SNPs can be discriminated by the kinetic differences exhibited in the dehybridization of PM and MM DNA duplexes in an alkaline solution using fluorescence microscopy. We combined this method with multifunctional encoded hydrogel particle array (fabricated by stop-flow lithography) to achieve fast kinetics and high versatility. This approach may serve as an effective alternative to temperature-based method for analyzing unamplified genomic DNA in point-of-care diagnostic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the post-ischemic skin blood flow response after withdrawal of antihypertensive therapy in hypertensive patients with normal blood pressure during treatment. DESIGN AND METHODS: Twenty hypertensive patients (group A) with a normal clinic blood pressure (<140/ 90 mmHg) receiving antihypertensive treatment (any monotherapy; one pill per day for at least 6 months) had their treatment discontinued. Before medication withdrawal and 2, 4, 12 and 24 weeks thereafter, the following measurements were made: clinic blood pressure, home blood pressure (three times per week, morning and evening) and skin blood flow response to a 5 min forearm arterial occlusion (using laser Doppler flowmetry). The patients were asked to perform an ambulatory blood pressure recording at any time if home blood pressure was > or =160/95 mmHg on two consecutive days, and treatment was initiated again, after determination of the skin hyperemic response, if daytime ambulatory blood pressure was > or =140/90 mmHg. The same studies were performed in 20 additional hypertensive individuals in whom antihypertensive treatment was not withdrawn (group B). The allocation of patients to groups A and B was random. RESULTS: The data fom 18 patients in group A who adhered strictly to the procedure were available for analysis. Seven of them had to start treatment again within the first 4 weeks of follow-up; four additional patients started treatment again during the next 8 weeks (group A1). The seven other patients remained untreated (group A2). The skin hyperemic response decreased significantly in patients in group A1 and returned to baseline values at the end of the study, when there were again receiving antihypertensive treatment. In patients in group A2 a significant attenuation of the hyperemic response was also observed. This impaired response was present even at the end of the 6 month follow-up, at which time the patients were still untreated but exhibited a significantly greater blood pressure than before drug discontinuation. The hyperemic response of patients who did not stop treatment (group B) did not change during the course of the study. CONCLUSIONS: Our findings show a decrease in the postischemic skin blood flow response after withdrawal of antihypertensive treatment in hypertensive patients. This impaired response may be due to the development of endothelial dysfunction, vascular remodeling, or both, and might contribute to the return of blood pressure to hypertensive values after withdrawal of antihypertensive therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Portable (roll-out) stop signs are used at school crossings in over 300 cities in Iowa. Their use conforms to the Code of Iowa, although it is not consistent with the provisions of the Manual on Uniform Traffic Control Devices adopted for nationwide application. A survey indicated that most users in Iowa believe that portable stop signs provide effective protection at school crossings, and favor their continued use. Other non-uniform signs that fold or rotate to display a STOP message only during certain hours are used at school crossings in over 60 cities in Iowa. Their use does not conform to either the Code of Iowa or the Manual on Uniform Traffic Control Devices. Users of these devices also tend to favor their continued use. A survey of other states indicated that use of temporary devices similar to those used in Iowa is not generally sanctioned. Some unsanctioned use apparently occurs in several states, however. A different type of portable stop sign for school crossings is authorized and widely used in one state. Portable stop signs similar to those used in Iowa are authorized in another state, although their use is quite limited. A few reports in the literature reviewed for this research discussed the use of portable stop signs. The authors of these reports uniformly recommended against the use of portable or temporary traffic control devices. Various reasons for this recommendation were given, although data to support the recommendation were not offered. As part of this research, field surveys were conducted at 54 locations in 33 communities where temporary stop control devices were in use at school crossings. Research personnel observed the obedience to stop control and measured the vehicular delay incurred. Stopped delay averaged 1.89 seconds/entering vehicle. Only 36.6 percent of the vehicles were observed to come to a complete stop at the study locations controlled by temporary stop control devices. However, this level of obedience does not differ from that observed at intersections controlled by permanent stop signs. Accident experience was compiled for 76 intersections in 33 communities in Iowa where temporary stop signs were used and, for comparative purposes, at 76 comparable intersections having other forms of control or operating without stop control. There were no significant differences in accident experience An economic analysis of vehicle operating costs, delay costs, and other costs indicated that temporary stop control generated costs only about 12 percent as great as permanent stop control for a street having a school crossing. Midblock pedestrian-actuated signals were shown to be cost effective in comparison with temporary stop signs under the conditions of use assumed. Such signals could be used effectively at a number of locations where temporary stop signs are being used. The results of this research do not provide a basis for recommending that use of portable stop signs be prohibited. However, erratic patterns of use of these devices and inadequate designs suggest that improved standards for their use are needed. Accordingly, nine recommendations are presented to enhance the efficiency of vehicular flow at school crossings, without causing a decline in the level of pedestrian protection being afforded.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To inhibit an ongoing flow of thoughts or actions has been largely considered to be a crucial executive function, and the stop-signal paradigm makes inhibitory control measurable. Stop-signal tasks usually combine two concurrent tasks, i.e., manual responses to a primary task (go-task) are occasionally countermanded by a stimulus which signals participants to inhibit their response in that trial (stop-task). Participants are always instructed not to wait for the stop-signal, since waiting strategies cause the response times to be unstable, invalidating the data. The aim of the present study was to experimentally control the strategies of waiting deliberately for the stop-signal in a stop-task by means of an algorithm that measured the variation in the reaction times to go-stimuli on-line, and displayed a warning legend urging participants to be faster when their reaction times were more than two standard deviations of the mean. Thirty-four university students performed a stop-task with go- and stop-stimuli, both of which were delivered in the visual modality and were lateralized within the visual field. The participants were divided into two groups (group A, without the algorithm, vs group B, with the algorithm). Group B exhibited lower variability of reaction times to go-stimuli, whereas no significant between-group differences were found in any of the measures of inhibitory control, showing that the algorithm succeeded in controlling the deliberate waiting strategies. Differences between deliberate and unintentional waiting strategies, and anxiety as a probable factor responsible for individual differences in deliberate waiting behavior, are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The non-Newtonian flow of dilute aqueous polyethylene oxide (PEO) solutions through microfabricated planar abrupt contraction-expansions is investigated. The contraction geometries are fabricated from a high-resolution chrome mask and cross-linked PDMS gels using the tools of soft-lithography. The small length scales and high deformation rates in the contraction throat lead to significant extensional flow effects even with dilute polymer solutions having time constants on the order of milliseconds. The dimensionless extra pressure drop across the contraction increases by more than 200% and is accompanied by significant upstream vortex growth. Streak photography and videomicroscopy using epifluorescent particles shows that the flow ultimately becomes unstable and three-dimensional. The moderate Reynolds numbers (0.03 ≤ Re ≤ 44) associated with these high Deborah number (0 ≤ De ≤ 600) microfluidic flows results in the exploration of new regions of the Re-De parameter space in which the effects of both elasticity and inertia can be observed. Understanding such interactions will be increasingly important in microfluidic applications involving complex fluids and can best be interpreted in terms of the elasticity number, El = De/Re, which is independent of the flow kinematics and depends only on the fluid rheology and the characteristic size of the device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, gaseous emissions and particles are measured during start-up and stop periods for an over-fed boiler and an under-fed boiler. Both gaseous and particulate matter emissions are continuously measured in the laboratory. The measurement of gaseous emissions includes oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), nitrogen oxide and (NO). The emissions rates are calculated from measured emissions concentrations and flue gas flow. The behaviours of the boilers during start-up and stop periods are analysed and the emissions are characterised in terms of CO, NO, TOC and particles (PM2.5 mass and number). The duration of the characterised periods vary between two boilers due to the difference in type of ignition and combustion control. The under-fed boiler B produces higher emissions during start-up periods than the over-fed boiler A. More hydrocarbon and particles are emitted by the under-fed boiler during stop periods. Accumulated mass of CO and TOC during start-up and stop periods contribute a major portion of the total mass emitted during whole operation. However, accumulated mass of NO and PM during start-up and stop periods are not significant as the duration of emission peak is relatively short.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, an anisotropic nonlinear diffusion equation for image restoration is presented. The model has two terms: the diffusion and the forcing term. The balance between these terms is made in a selective way, in which boundary points and interior points of the objects that make up the image are treated differently. The optimal smoothing time concept, which allows for finding the ideal stop time for the evolution of the partial differential equation is also proposed. Numerical results show the proposed model's high performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Continuous conveyors with a dynamic merge were developed with adaptable control equipment to differentiate these merges from competing Stop-and-Go merges. With a dynamic merge, the partial flows are manipulated by influencing speeds so that transport units need not stop for the merge. This leads to a more uniform flow of materials, which is qualitatively observable and verifiable in long-term measurements. And although this type of merge is visually mesmerizing, does it lead to advantages from the view of material flow technology? Our study with real data indicates that a dynamic merge shows a 24% increase in performance, but only for symmetric or nearly symmetric flows. This performance advantage decreases as the flows become less symmetric, approaching the throughput of traditional Stop-and-Go merges. And with a cost premium for a continuous merge of approximately 10% due to the additional technical components (belt conveyor, adjustable drive engines, software, etc.), this restricts their economical use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We demonstrate the capability of a laser micromachining workstation for cost-effective manufacturing of a variety of microfluidic devices, including SU-8 microchannels on silicon wafers and 3D complex structures made on polyimide Kapton® or poly carbonate (PC). The workstation combines a KrF excimer laser at 248 nm and a Nd3+:YVO4 DPSS with a frequency tripled at 355 nm with a lens magnification 10X, both lasers working at a pulsed regime with nanoseconds (ns) pulse duration. Workstation also includes a high-resolution motorized XYZ-tilt axis (~ 1 um / axis) and a Through The Lens (TTL) imaging system for a high accurate positioning over a 120 x 120 mm working area. We have surveyed different fabrication techniques: direct writing lithography,mask manufacturing for contact lithography and polymer laser ablation for complex 3D devices, achieving width channels down to 13μ m on 50μ m SU-8 thickness using direct writing lithography, and width channels of 40 μm for polyimide on SiO2 plate. Finally, we have tested the use of some devices for capillary chips measuring the flow speed for liquids with different viscosities. As a result, we have characterized the presence of liquid in the channel by interferometric microscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Currently the data storage industry is facing huge challenges with respect to the conventional method of recording data known as longitudinal magnetic recording. This technology is fast approaching a fundamental physical limit, known as the superparamagnetic limit. A unique way of deferring the superparamagnetic limit incorporates the patterning of magnetic media. This method exploits the use of lithography tools to predetermine the areal density. Various nanofabrication schemes are employed to pattern the magnetic material are Focus Ion Beam (FIB), E-beam Lithography (EBL), UV-Optical Lithography (UVL), Self-assembled Media Synthesis and Nanoimprint Lithography (NIL). Although there are many challenges to manufacturing patterned media, the large potential gains offered in terms of areal density make it one of the most promising new technologies on the horizon for future hard disk drives. Thus, this dissertation contributes to the development of future alternative data storage devices and deferring the superparamagnetic limit by designing and characterizing patterned magnetic media using a novel nanoimprint replication process called "Step and Flash Imprint lithography". As opposed to hot embossing and other high temperature-low pressure processes, SFIL can be performed at low pressure and room temperature. Initial experiments carried out, consisted of process flow design for the patterned structures on sputtered Ni-Fe thin films. The main one being the defectivity analysis for the SFIL process conducted by fabricating and testing devices of varying feature sizes (50 nm to 1 μm) and inspecting them optically as well as testing them electrically. Once the SFIL process was optimized, a number of Ni-Fe coated wafers were imprinted with a template having the patterned topography. A minimum feature size of 40 nm was obtained with varying pitch (1:1, 1:1.5, 1:2, and 1:3). The Characterization steps involved extensive SEM study at each processing step as well as Atomic Force Microscopy (AFM) and Magnetic Force Microscopy (MFM) analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Performance testing methods of boilers in transient operating conditions (start, stop and combustion power modulation sequences) need the combustion rate quantified to allow for the emissions to be quantified. One way of quantifying the combustion rate of a boiler during transient operating conditions is by measuring the flue gas flow rate. The flow conditions in chimneys of single family house boilers pose a challenge however, mainly because of the low flow velocity. The main objectives of the work were to characterize the flow conditions in residential chimneys, to evaluate the use of the Pitot-static method and the averaging Pitot method, and to develop and test a calibration method for averaging Pitot probes for low

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapidity-odd directed flow (v1) measurements for charged pions, protons, and antiprotons near midrapidity (y=0) are reported in sNN=7.7, 11.5, 19.6, 27, 39, 62.4, and 200 GeV Au+Au collisions as recorded by the STAR detector at the Relativistic Heavy Ion Collider. At intermediate impact parameters, the proton and net-proton slope parameter dv1/dy|y=0 shows a minimum between 11.5 and 19.6 GeV. In addition, the net-proton dv1/dy|y=0 changes sign twice between 7.7 and 39 GeV. The proton and net-proton results qualitatively resemble predictions of a hydrodynamic model with a first-order phase transition from hadronic matter to deconfined matter, and differ from hadronic transport calculations.