1000 resultados para stop period


Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this study, gaseous emissions and particles are measured during start-up and stop periods for an over-fed boiler and an under-fed boiler. Both gaseous and particulate matter emissions are continuously measured in the laboratory. The measurement of gaseous emissions includes oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), nitrogen oxide and (NO). The emissions rates are calculated from measured emissions concentrations and flue gas flow. The behaviours of the boilers during start-up and stop periods are analysed and the emissions are characterised in terms of CO, NO, TOC and particles (PM2.5 mass and number). The duration of the characterised periods vary between two boilers due to the difference in type of ignition and combustion control. The under-fed boiler B produces higher emissions during start-up periods than the over-fed boiler A. More hydrocarbon and particles are emitted by the under-fed boiler during stop periods. Accumulated mass of CO and TOC during start-up and stop periods contribute a major portion of the total mass emitted during whole operation. However, accumulated mass of NO and PM during start-up and stop periods are not significant as the duration of emission peak is relatively short.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The off-cycle refrigerant mass migration has a direct influence on the on-cycle performance since compressor energy is necessary to redistribute the refrigerant mass. No studies, as of today, are available in the open literature which experimentally measured the lubricant migration within a refrigeration system during cycling or stop/start transients. Therefore, experimental procedures measuring the refrigerant and lubricant migration through the major components of a refrigeration system during stop/start transients were developed and implemented. Results identifying the underlying physics are presented. The refrigerant and lubricant migration of an R134a automotive A/C system-utilizing a fixed orifice tube, minichannel condenser, plate and fin evaporator, U-tube type accumulator and fixed displacement compressor-was measured across five sections divided by ball valves. Using the Quick-Closing Valve Technique (QCVT) combined with the Remove and Weigh Technique (RWT) using liquid nitrogen as the condensing agent resulted in a measurement uncertainty of 0.4 percent regarding the total refrigerant mass in the system. The determination of the lubricant mass distribution was achieved by employing three different techniques-Remove and Weigh, Mix and Sample, and Flushing. To employ the Mix and Sample Technique a device-called the Mix and Sample Device-was built. A method to separate the refrigerant and lubricant was developed with an accuracy-after separation-of 0.04 grams of refrigerant left in the lubricant. When applying the three techniques, the total amount of lubricant mass in the system was determined to within two percent. The combination of measurement results-infrared photography and high speed and real time videography-provide unprecedented insight into the mechanisms of refrigerant and lubricant migration during stop-start operation. During the compressor stop period, the primary refrigerant mass migration is caused by, and follows, the diminishing pressure difference across the expansion device. The secondary refrigerant migration is caused by a pressure gradient as a result of thermal nonequilibrium within the system and causes only vapor phase refrigerant migration. Lubricant migration is proportional to the refrigerant mass during the primary refrigerant mass migration. During the secondary refrigerant mass migration lubricant is not migrating. The start-up refrigerant mass migration is caused by an imbalance of the refrigerant mass flow rates across the compressor and expansion device. The higher compressor refrigerant mass flow rate was a result of the entrainment of foam into the U-tube of the accumulator. The lubricant mass migration during the start-up was not proportional to the refrigerant mass migration. The presence of water condensate on the evaporator affected the refrigerant mass migration during the compressor stop period. Caused by an evaporative cooling effect the evaporator held 56 percent of the total refrigerant mass in the system after three minutes of compressor stop time-compared to 25 percent when no water condensate was present on the evaporator coil. Foam entrainment led to a faster lubricant and refrigerant mass migration out of the accumulator than liquid entrainment through the hole at the bottom of the U-tube. The latter was observed for when water condensate was present on the evaporator coil because-as a result of the higher amount of refrigerant mass in the evaporator before start-up-the entrainment of foam into the U-tube of the accumulator ceased before the steady state refrigerant mass distribution was reached.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Evaluate the efficacy of cumulative doses (CDs) of 131I-iodide therapy (RIT) in differentiated thyroid cancer (DTC). SUBJECTS AND METHODS: The probability of progressive disease according to CDs was evaluated in patients < 45 years old and > 45 years old and correlated to tumor-node-metastasis (TNM), thyroglobulin values, histological types and variants, age, and zduration of the disease. RESULTS: At the end of a follow-up period of 69 ± 56 months, 85 out of 150 DTC patients submitted to fixed doses RIT had no evidence of disease, 47 had stable disease and 18 had progressive disease. Higher CDs were used in the more aggressive variants (p < 0.0001), higher TNM stages (p < 0.0001), and follicular carcinomas (p = 0.0034). Probability of disease progression was higher with CDs > 600 mCi in patients > 45 years old and with CDs > 800 mCi in patients < 45 years. CONCLUSION: Although some patients may still respond to high CDs, the impact of further RIT should be carefully evaluated and other treatment strategies may be warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In November 2010, the Public Health Agencycommissioned Social Market Research (www.socialmarketresearch.co.uk) to undertake a formative evaluation of the pilot 'One Stop Shop' (OSS) Programme. This report presents the outcomes from this evaluation as well as recommendations to support the further development of the programme beyond the pilot period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The stop-loss reinsurance is one of the most important reinsurance contracts in the insurance market. From the insurer point of view, it presents an interesting property: it is optimal if the criterion of minimizing the variance of the cost of the insurer is used. The aim of the paper is to contribute to the analysis of the stop-loss contract in one period from the point of view of the insurer and the reinsurer. Firstly, the influence of the parameters of the reinsurance contract on the correlation coefficient between the cost of the insurer and the cost of the reinsurer is studied. Secondly, the optimal stop-loss contract is obtained if the criterion used is the maximization of the joint survival probability of the insurer and the reinsurer in one period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, microstrip lines magnetically coupled to splitring resonators (SRRs) are conquved to electromagnetic bundgup (EBG) nr,rrostrip lines in terns q/ their stop-heard penjbrnmrnce and dimensions. In bath types o/ trunsmis•siou lines, signal propagation is inhibited in it certain jequency bwuL For EBG microstrip lines, the central frequency of such a forbidden band is determined by the period of the structure, whereas in SRR-hased microstrip lines the position of the frequency gap depends on the quasi-static resonant frequency of the rings. The main relevant conrributiun of this paper is to provide a tuning procedure to control the gap width in SRR microstrip lines, and to show that by using SRRs, device dimensions ale much smaller than those required by EBGs in order to obtain similar stop-banal performance. This has been demonstrated by fill-wave electromagnetic simulations and experimentally verified from the characterization ql two fabricated microstrip lines: one with rectangular SRRs etched on the upper substrate side, and the other with a periodic perturbation cf'strip width. For similar rejection and 1-(;H,. gap width centered at 4.5 Gllz, it has been found that the SRR microstrip line is•,fve times shorter. In addition, no ripple is appreciable in the allowed band for the .SRR-hared structure, whereas due to dispersion, certain mismatch is expected in the EBG prototype. Due to the high-frequency selectivity, controllable gap width, and small dimensions, it is believed that SRR coupled to planar transmission lines can have an actual impact on the design of stop-band filters compatible with planar technology, and can be an alternative to present solutions based on distributed approaches or EBG

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article deals with the European minorities in the period between the two world wars and with their final expulsion from nation-states at the end of World War II. First, the tensions which arose between the organised minorities and the successor states of the Habsburg Monarchy are accounted for primarily by the argument that the various minorities located within the successor states had already undergone a comprehensive processes of nationalisation within the Habsburg Empire. Therefore they were able to resist assimilation by the political elites of the new titular nations (Czechs, Poles, Rumanians, Serbs). A second topic is that of the use made of the minorities issue by Adolf Hitler to help achieve his expansionist aims. The minorities issue was central to the international destabilisation of interwar Europe. Finally, the mass expulsion of minorities (above all, Germans) after the end of the war is explained by strategic considerations on the part of the Allied powers as well as involving the nation-state regimes. It is argued, against a commonly held view, that German atrocities during the period of occupation had little to do with the decision to expel most ethnic Germans from their territories of settlement in Poland, Czechoslovakia and Yugoslavia. The article shows that it is necessary to treat national minorities in the first half of the twentieth century as a single phenomenon which shares similar features across the various nation-states of East-Central Europe.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Federal Highway Administration, Office of Research and Development, Washington, D.C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Federal Highway Administration, Office of Research and Development, Washington, D.C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Turner-Fairbank Highway Research Center, McLean, Va.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Federal Highway Administration, Offices of Research and Development, Washington, D.C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Long period gratings (LPGs) were written into a D-shaped optical fibre, which has an elliptical core with a W-shaped refractive index profile. The LPG's attenuation bands were found to be sensitive to the polarisation of the interrogating light with a spectral separation of about 15nm between the two orthogonal polarisation states. In addition, two spectrally overlapping attenuation bands corresponding to orthogonal polarisation states were observed; modelling successfully reproduced this spectral feature. The spectral sensitivity of both orthogonal states was experimentally measured with respect to temperature, surrounding refractive index, and directional bending. These LPG devices produced blue and red wavelength shifts of the stop-bands due to bending in different directions. The measured spectral sensitivities to curvatures, d?/dR , ranged from -3.56nm m to +6.51nm m. The results obtained with these LPGs suggest that this type of fibre may be useful as a shape/bend sensor. It was also demonstrated that the neighbouring bands could be used to discriminate between temperature and bending and that overlapping orthogonal polarisation attenuation bands can be used to minimise error associated with polarisation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Limited data are available concerning the evolution of the left atrial volume index (LAVI) in pre-heart failure (HF) patients. The aim of this study was to investigate clinical characteristics and serological biomarkers in a cohort with risk factors for HF and evidence of serial atrial dilatation.

METHODS AND RESULTS: This was a prospective substudy within the framework of the STOP-HF cohort (NCT00921960) involving 518 patients with risk factors for HF electively undergoing serial clinical, echocardiographic, and natriuretic peptide assessment. Mean follow-up time between assessments was 15 ± 6 months. 'Progressors' (n = 39) were defined as those with serial LAVI change ≥3.5 mL/m(2) (and baseline LAVI between 20 and 34 mL/m(2)). This cut-off was derived from a calculated reference change value above the biological, analytical, and observer variability of serial LAVI measurement. Multivariate analysis identified significant baseline clinical associates of LAVI progression as increased age, beta-blocker usage, and left ventricular mass index (all P < 0.05). Serological biomarkers were measured in a randomly selected subcohort of 30 'Progressors' matched to 30 'Non-progressors'. For 'Progressors', relative changes in matrix metalloproteinase 9 (MMP9), tissue inhibitor of metalloproteinase 1 (TIMP1), and the TIMP1/MMP9 ratio, markers of interstitial remodelling, tracked with changes in LAVI over time (all P < 0.05).

CONCLUSION: Accelerated LAVI increase was found to occur in up to 14% of all pre-HF patients undergoing serial echocardiograms over a relatively short follow-up period. In a randomly selected subcohort of 'Progressors', changes in LAVI were closely linked with alterations in MMP9, TIMP1, and the ratio of these enzymes, a potential aid in highlighting this at-risk group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary intraosseous carcinoma of the jaws (PIOSCC) might arise from odontogenic epithelium, more commonly from a previous odontogenic cyst. The aim of this case is to illustrate that the clinician should consider that an apparent benign dentigerous cyst can suffer malignant transformation and that all material removed from a patient must be evaluated histologically. A 44-year-old man presented in a routine periapical X-ray an impacted lower left third molar with radiolucency over its crown. Ten years later, the patient complained of pain in the same region and the tooth was extracted. After one month, the patient still complained of pain and suffered a fracture of the mandible. A biopsy was performed and carcinoma was diagnosed. The patient was treated surgically with adjuvant radio- and chemotherapy and after 8 years, he is well without signs of recurrences. This report describes a central mandibular carcinoma probably developed from a previous dentigerous cyst.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study evaluated ultra-structural dentine changes at the apical stop after CO(2) laser irradiation used during biomechanical preparation. Background: Most studies evaluating the sealing efficiency of CO(2) lasers have been carried out after apical root canal resections and retro-filling procedures. Methods: Sixty human canines were prepared with #1 to #6 Largo burs. The apical stops were established at 1 mm (n = 30) and 2 mm (n = 30) from the apex. Final irrigation was performed with 1% NaOCl and 15% EDTA followed by 20 ml of distilled and deionized water. Specimens were subdivided into three subgroups (n = 10 for each stop distance): GI-no radiation (n = 20); GII-3W potency (n = 20), GIII-5W potency (n = 20). After preparation, specimens were evaluated by scanning electron microscopy, with ultra-structural changes classified according to a scoring system based on six qualitatively different outcomes. Results: Statistical analysis using the Mann-Whitney test confirmed more intense results for the specimens irradiated at 5 W potency than at 3 W (p<0.0001). The Kruskal-Wallis test indicated that when using the same potencies (3 or 5 W) at 1 and 2 mm from the apex, there were no statistically significant differences in ultra-structural changes. Conclusions: Our results showed that ultra-structural changes ranged from smear layer removal to dentine fusion. As laser potency was increased from 3 to 5 W, ultra-structural changes included extensive fused lava-like areas sealing the apical foramen.