857 resultados para static compliance
Resumo:
Cardiovascular disease (CVD) continues to be one of the top causes of mortality in the world. World Heart Organization (WHO) reported that in 2004, CVD contributed to almost 30% of death from estimated worldwide death figures of 58 million[1]. Heart failure treatment varies from lifestyle adjustment to heart transplantation; its aims are to reduce HF symptoms, prolong patient survival and minimize risk [2]. One alternative available in the market for HF treatment is Left Ventricular Assist Device (LVAD). Chronic Intermittent Mechanical Support (CIMS) device is a novel (LVAD) heart failure treatment using counterpulsation similar to Intra Aortic Balloon Pumps (IABP). However, the implantation site of the CIMS balloon is in the ascending aorta just distal to aortic valve contrasted with IABP in the descending aorta. Counterpulsation coupled with implantation close to the aortic valve enables comparable flow augmentation with reduced balloon volume. Two prototypes of the CIMS balloon were constructed using rapid prototyping: the straight-body model is a cylindrical tube with a silicone membrane lining with zero expansive compliance. The compliant-body model had a bulging structure that allowed the membrane to expand under native systolic pressure increasing the device’s static compliance to 1.5 mL/mmHg. This study examined the effect of device compliance and vascular compliance on counterpulsating flow augmentation. Both prototypes were tested on a two-element Windkessel model human mock circulatory loop (MCL). The devices were placed just distal to aortic valve and left coronary artery. The MCL mimicked HF with cardiac output of 3 L/min, left ventricular pressure of 85/15 mmHg, aortic pressure of 70/50 mmHg and left coronary artery flow rate of 66 mL/min. The mean arterial pressure (MAP) was calculated to be 57 mmHg. Arterial compliance was set to be1.25 mL/mmHg and 2.5 mL/mmHg. Inflation of the balloon was triggered at the dicrotic notch while deflation was at minimum aortic pressure prior to systole. Important haemodynamics parameters such as left ventricular pressure (LVP), aortic pressure (AoP), cardiac output (CO), left coronary artery flowrate (QcorMean), and dP (Peak aortic diastolic augmentation pressure – AoPmax ) were simultaneously recorded for both non-assisted mode and assisted mode. ANOVA was used to analyse the effect of both factors (balloon and arterial compliance) to flow augmentation. The results showed that for cardiac output and left coronary artery flowrate, there were significant difference between balloon and arterial compliance at p < 0.001. Cardiac output recorded maximum output at 18% for compliant body and stiff arterial compliance. Left coronary artery flowrate also recorded around 20% increase due to compliant body and stiffer arterial compliance. Resistance to blood ejection recorded highest difference for combination of straight body and stiffer arterial compliance. From these results it is clear that both balloon and arterial compliance are statistically significant factors for flow augmentation on peripheral artery and reduction of resistance. Although the result for resistance reduction was different from flow augmentation, these results serves as an important aspect which will influence the future design of the CIMS balloon and its control strategy. References: 1. Mathers C, Boerma T, Fat DM. The Global Burden of disease:2004 update. Geneva: World Heatlh Organization; 2008. 2. Jessup M, Brozena S. Heart Failure. N Engl J Med 2003;348:2007-18.
Resumo:
Continuous positive airway pressure, aimed at preventing pulmonary atelectasis, has been used for decades to reduce lung injury in critically ill patients. In neonatal practice, it is increasingly used worldwide as a primary form of respiratory support due to its low cost and because it reduces the need for endotracheal intubation and conventional mechanical ventilation. We studied the anesthetized in vivo rat and determined the optimal circuit design for delivery of continuous positive airway pressure. We investigated the effects of continuous positive airway pressure following lipopolysaccharide administration in the anesthetized rat. Whereas neither continuous positive airway pressure nor lipopolysaccharide alone caused lung injury, continuous positive airway pressure applied following intravenous lipopolysaccharide resulted in increased microvascular permeability, elevated cytokine protein and mRNA production, and impaired static compliance. A dose-response relationship was demonstrated whereby higher levels of continuous positive airway pressure (up to 6 cmH(2)O) caused greater lung injury. Lung injury was attenuated by pretreatment with dexamethasone. These data demonstrate that despite optimal circuit design, continuous positive airway pressure causes significant lung injury (proportional to the airway pressure) in the setting of circulating lipopolysaccharide. Although we would currently avoid direct extrapolation of these findings to clinical practice, we believe that in the context of increasing clinical use, these data are grounds for concern and warrant further investigation.
Aspectos da função pulmonar após revascularização do miocárdio relacionados com risco pré-operatório
Resumo:
OBJETIVOS: Comparar os valores das complacências dinâmica e estática, da resistência de vias aéreas (Cdin, Cest e Raw) e do índice de troca gasosa (PaO2/FiO2), no pós-operatório de cirurgia de revascularização miocárdica (RM) com os parâmetros de normalidade e comparar os valores destas variáveis entre grupos com e sem fatores de risco no pré-operatório. MÉTODO: Questionamento aos doentes a respeito de antecedentes pulmonares, sintomas respiratórios, tabagismo e comorbidades. Após cirurgia de RM, foram feitas as medidas de Cdin, Cest, Raw e do PaO2/FiO2. As variáveis foram comparadas com a normalidade e relacionadas às variáveis pré e pós-operatórias pelo Teste não-paramétrico de Mann-Whitney e pelo Teste para uma proporção (p<0,05). RESULTADO: Foram avaliados 70 doentes (61% homens), com idade entre 26 e 77 anos. em relação à normalidade, apresentaram diminuição da Cdin e da Cest, 64 e 66 pacientes, respectivamente, e 24 apresentaram aumento da Raw. Aproximadamente 50% apresentaram redução do PaO2/FiO2. Não houve diferença significante das variáveis pós-operatórias com respeito aos antecedentes pulmonares, sintomas respiratórios e tabagismo. Nos pacientes com comorbidades, o PaO2/FiO2 foi significativamente menor e, nos homens, a Cdin e a Cest foram maiores que nas mulheres. CONCLUSÃO: As complacências pulmonares estão diminuídas na maioria dos pacientes, e a resistência das vias aéreas está aumentada em um terço deles. O índice de troca gasosa encontra-se diminuído em metade deles. A presença de antecedentes pulmonares, sintomas respiratórios e tabagismo não influencia as variáveis mecânicas, mas o índice de troca gasosa é influenciado pela presença de comorbidades.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Patients who went through a Stroke may require mechanical ventilation (MV) in the acute phase of the disease and, on MV, they may show alterations in the respiratory mechanic. Physiotherapy techniques are applied in patients on MV to improve their respiratory mechanic. Thus, the purpose of this study was to evaluate the effects of the Respiratory Physiotherapy into the dynamic compliance (Cdyn), static compliance (Cst) and airway resistance (Rwa) in Stroke patients on MV. In order to do that, patients with Stroke diagnostic on MV were evaluated, before and after the use of Physiotherapy techniques (manual rib-cage compression, thoracic decompression, zero end expiratory pressure and suctioning). Cdyn, Cst and Rwa were the researched variables. Statistical Analysis was made using Paired T-Test with statistical significance with p-values no greater than 5%. Eleven patients were part of the study, with an average of 64,6±12,5 years old. Cdyn increased after physiotherapy from 29,3±16,1 ml/cmH2O to 33,8±16,7 ml/cmH2O (p=0,03). Cst also increased from 44,4±20,7 ml/cmH2O to 54,0±26,6 ml/cmH2O (p=0,024). No significant difference was detected for Rwa between the before and after moments (Before – 8,0±3,2 cmH2O/l/s, After – 7,3±2,25 cmH2O/l/s; p=0,45). It was possible to conclude that both dynamic and static compliance increased after physiotherapy, but the airway resistance did not increase in patients with stroke on mechanical ventilation.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Background: Acute respiratory distress syndrome (ARDS) is associated with high in-hospital mortality. Alveolar recruitment followed by ventilation at optimal titrated PEEP may reduce ventilator-induced lung injury and improve oxygenation in patients with ARDS, but the effects on mortality and other clinical outcomes remain unknown. This article reports the rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART). Methods/Design: ART is a pragmatic, multicenter, randomized (concealed), controlled trial, which aims to determine if maximum stepwise alveolar recruitment associated with PEEP titration is able to increase 28-day survival in patients with ARDS compared to conventional treatment (ARDSNet strategy). We will enroll adult patients with ARDS of less than 72 h duration. The intervention group will receive an alveolar recruitment maneuver, with stepwise increases of PEEP achieving 45 cmH(2)O and peak pressure of 60 cmH2O, followed by ventilation with optimal PEEP titrated according to the static compliance of the respiratory system. In the control group, mechanical ventilation will follow a conventional protocol (ARDSNet). In both groups, we will use controlled volume mode with low tidal volumes (4 to 6 mL/kg of predicted body weight) and targeting plateau pressure <= 30 cmH2O. The primary outcome is 28-day survival, and the secondary outcomes are: length of ICU stay; length of hospital stay; pneumothorax requiring chest tube during first 7 days; barotrauma during first 7 days; mechanical ventilation-free days from days 1 to 28; ICU, in-hospital, and 6-month survival. ART is an event-guided trial planned to last until 520 events (deaths within 28 days) are observed. These events allow detection of a hazard ratio of 0.75, with 90% power and two-tailed type I error of 5%. All analysis will follow the intention-to-treat principle. Discussion: If the ART strategy with maximum recruitment and PEEP titration improves 28-day survival, this will represent a notable advance to the care of ARDS patients. Conversely, if the ART strategy is similar or inferior to the current evidence-based strategy (ARDSNet), this should also change current practice as many institutions routinely employ recruitment maneuvers and set PEEP levels according to some titration method.
Resumo:
Dentro da classe Reptilia, a ordem Testudines possui algumas características exclusivas, tais como a fusão das costelas e da coluna vertebral e a perda dos músculos intercostais, inviabilizando a ventilação costal. Além disso, as posições naturais que os Testudines exibem podem influenciar a mecânica ventilatória. O presente estudo teve como objetivo testar a influência do posicionamento do corpo sobre a mecânica ventilatória através da complacência estática e dinâmica e analisar através da respirometria aberta o padrão ventilatório e o custo metabólico da ventilação através da exposição em normóxia, hipóxia e hipercarbia em Trachemys scripta e Chelonoidis carbonarius. Os volumes pulmonares, complacência estática e dinâmica em C. carbonarius foram inferiores aos de T. scripta e outras espécies de Testudines já estudadas. Verificou-se também influência das posições sobre a mecânica ventilatória nas duas espécies, sendo a posição de membros e cabeça retraídos na carapaça apresentando os menores valores (p<0,05). Hipóxia e hipercarbia estimularam o aumento da ventilação nas duas espécies estudadas (p<0,05), sendo observadas maiores alterações da frequência ventilatória e volume corrente em C. carbonarius. Os valores de custo metabólico da ventilação foram baixos devido à uma diminuição no consumo de oxigênio em hipóxia e hipercarbia, indicando depressão metabólica em ambas as espécies ou então o método para calcular esse custo não ser ideal. Ao relacionar os dados de consumo de oxigênio com os de ventilação, verificou-se a possibilidade de shunt cardíaco esquerdo-direito. Será necessário calcular o trabalho mecânico da ventilação a fim de entender melhor a mecânica ventilatória nas duas espécies e posteriormente relacionar os dados de ventilação e custo metabólico da ventilação com os de trabalho mecânico.
Resumo:
The surgical removal of the post-hepatic septum (PHS) in the tegu lizard, Tupinambis merianae, significantly reduces resting lung volume (VLr) and maximal lung volume (VLm) when compared with tegus with intact PHS. Standardised for body mass (MB), static lung compliance was significantly less in tegus without PHS. Pleural and abdominal pressures followed, like ventilation, a biphasic pattern. In general, pressures increased during expiration and decreased during inspiration. However, during expiration pressure changes showed a marked intra- and interindividual variation. The removal of the PHS resulted in a lower cranio-caudal intracoelomic pressure differential, but had no effect on the general pattern of pressure changes accompanying ventilation. These results show that a perforated PHS that lacks striated muscle has significant influence on static breathing mechanics in Tupinambis and by analogy provides valuable insight into similar processes that led to the evolution of the mammalian diaphragm. © 2003 Elsevier Science B.V. All rights reserved.
Resumo:
Compliance is an important issue in environmental regulation. In this paper, we discuss some of the key elements of the problem and analyze a situation where emissions are not random and firms are risk-neutral. We study the firm's decision on emissions and compliance when the environmental regulation is based on standards and the enforcement agency audits the firm with a certain probability. We then compare total emissions when environmental regulation is based on different instruments: standards, taxes, and tradable permits. We show that when compliance is an issue, environmental taxes are superior to the other instruments. We also analyze the (static) efficiency of the solution.
Resumo:
The paper analyzes how to comply with an emission constraint, which restricts the use of an established energy technique, given the two options to save energy and to invest in two alternative energy techniques. These techniques differ in their deterioration rates and the investment lags of the corresponding capital stocks. Thus, the paper takes a medium-term perspective on climate change mitigation, where the time horizon is too short for technological change to occur, but long enough for capital stocks to accumulate and deteriorate. It is shown that, in general, only one of the two alternative techniques prevails in the stationary state, although, both techniques might be utilized during the transition phase. Hence, while in a static economy only one technique is efficient, this is not necessarily true in a dynamic economy.
Resumo:
In this thesis, we explore three methods for the geometrico-static modelling of continuum parallel robots. Inspired by biological trunks, tentacles and snakes, continuum robot designs can reach confined spaces, manipulate objects in complex environments and conform to curvilinear paths in space. In addition, parallel continuum manipulators have the potential to inherit some of the compactness and compliance of continuum robots while retaining some of the precision, stability and strength of rigid-links parallel robots. Subsequently, the foundation of our work is performed on slender beam by applying the Cosserat rod theory, appropriate to model continuum robots. After that, three different approaches are developed on a case study of a planar parallel continuum robot constituted of two connected flexible links. We solve the forward and inverse geometrico-static problem namely by using (a) shooting methods to obtain a numerical solution, (b) an elliptic method to find a quasi-analytical solution, and (c) the Corde model to perform further model analysis. The performances of each of the studied methods are evaluated and their limits are highlighted. This thesis is divided as follows. Chapter one gives the introduction on the field of the continuum robotics and introduce the parallel continuum robots that is studied in this work. Chapter two describe the geometrico-static problem and gives the mathematical description of this problem. Chapter three explains the numerical approach with the shooting method and chapter four introduce the quasi-analytical solution. Then, Chapter five introduce the analytic method inspired by the Corde model and chapter six gives the conclusions of this work.
Resumo:
OBJECTIVES: The aim of this study was to assess the infuence of efforts applied to modify the patients' behavior towards periodontal maintenance. MATERIAL AND METHODS: Patients were classifed into three groups: Complete Compliance (participation in all visits), Irregular Compliance (irregular participation, one or more missing appointments), and Noncompliance (abandoned or never returned to the program). Complete compliers received usual procedures of the maintenance visit. The irregular compliers and non-compliers received usual procedures and strategies such as reminding next visit, informing patients on both periodontal disease and importance of maintenance, motivating the patient who showed an improvement in compliance. Thus, 137 patients were observed for 12 months. RESULTS: The degree of compliance has increased signifcantly during this period (p=0.001). No association was detected between age or gender and compliance degree. CONCLUSIONS: The results have shown that the intervention applied had a favorable infuence on the patients' compliance.
Resumo:
Background: The Brazilian consensus recommends a short-term treatment course with clarithromycin, amoxicillin and proton-pump inhibitor for the eradication of Helicobacter pylori ( H. pylori). This treatment course has good efficacy, but cannot be afforded by a large part of the population. Azithromycin, amoxicillin and omeprazole are subsidized, for several aims, by the Brazilian federal government. Therefore, a short-term treatment course that uses these drugs is a low-cost one, but its efficacy regarding the bacterium eradication is yet to be demonstrated. The study's purpose was to verify the efficacy of H. pylori eradication in infected patients who presented peptic ulcer disease, using the association of azithromycin, amoxicillin and omeprazole. Methods: Sixty patients with peptic ulcer diagnosed by upper digestive endoscopy and H. pylori infection documented by rapid urease test, histological analysis and urea breath test were treated for six days with a combination of azithromycin 500 mg and omeprazole 20 mg, in a single daily dose, associated with amoxicillin 500 mg 3 times a day. The eradication control was carried out 12 weeks after the treatment by means of the same diagnostic tests. The eradication rates were calculated with 95% confidence interval. Results: The eradication rate was 38% per intention to treat and 41% per protocol. Few adverse effects were observed and treatment compliance was high. Conclusion: Despite its low cost and high compliance, the low eradication rate does not allow the recommendation of the triple therapy with azithromycin as an adequate treatment for H. pylori infection.