17 resultados para stapling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PowerPoint presentation on electrosurgery and surgical stapling

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The effectiveness of various appendiceal stump closure methods has not been evaluated systematically. The aim of this study was to compare the morbidity of stump closure by stapling or use of endoloops. METHODS: A non-concurrent cohort study of prospectively acquired data was performed. The primary outcome variable was the rate of intra-abdominal surgical-site infection. Secondary outcome measures were complications, duration of intervention, hospital stay, rate of readmission to hospital and the difference in direct costs of the operation. RESULTS: Staples were used in 60.5 per cent and endoloops in 39.5 per cent of 6486 patients operated on for suspected appendicitis between January 1995 and December 2003. Among 4489 patients with acute appendicitis the rate of intra-abdominal surgical-site infection was 0.7 per cent in the stapler group and 1.7 per cent in the endoloop group (P = 0.004). The rate of readmission to hospital was 0.9 and 2.1 per cent respectively (P = 0.001). CONCLUSION: Application of a stapler for transection and closure of the appendiceal stump in patients with acute appendicitis lowered the risk of postoperative intra-abdominal surgical-site infection and the need for readmission to hospital.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Recent advances in laparoscopic devices and experience with advanced techniques have increased the indications for laparoscopic liver. Aim: The aim of this work was to present a video with technical aspects of a pure laparoscopic left hemi-hepatectomy (segments 2, 3, and 4) by using the intrahepatic Glissonian approach and control of venous outflow without hilar dissection or the Pringle maneuver. Patient and Method: A 63-year-old woman with a 5-cm solitary liver metastasis was referred for treatment. Four trocars were used. The left lobe was pulled upward and the lesser omentum was divided, exposing Arantius' ligament. This ligament is a useful landmark for the identification of the main left Glissonian pedicle. A small anterior incision was made in front of the hilum, and a large clamp was introduced behind the Arantius' ligament toward the anterior incision, allowing control of the left main sheath. Ischemic discoloration of the left liver was achieved and marked with cautery. The vascular clamp was replaced by a stapler. If ischemic delineation was coincident with a previously marked area, the stapler was fired. The left hepatic vein was dissected and encircled. Parenchymal transection and vascular control of the hepatic veins were accomplished with a Harmonic scalpel and an endoscopic stapling device, as appropriate. All these steps were performed without the Pringle maneuver and without hand assistance. Results: Operative time was 220 minutes with minimum blood loss. Hospital stay was 4 days. Pathology showed free surgical margins. The patient is alive with no signs of recurrence 18 months after the operation. Conclusion: Totally laparoscopic left hemihepatectomy is safe and feasible in selected patients and should be considered for patients with benign or malignant liver neoplasms. The described technique, with the use of the intrahepatic Glissonian approach and control of venous outflow, may facilitate laparoscopic left hemihepatectomy by reducing the technical difficulties in pedicle control and may decrease bleeding during liver transection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: Surgical staple line dehiscence usually leads to severe complications. Several techniques and materials have been used to reinforce this stapling and thus reduce the related complications. The objective was to compare safety of two types of anastomotic reinforcement in open gastric bypass. Methods: A prospective, randomized study comparing an extraluminal suture, fibrin glue, and a nonpermanent buttressing material, Seamguard (R), for staple line reinforcement. Fibrin glue was excluded from the study and analysis after two leaks, requiring surgical reintervention, antibiotic therapy, and prolonged patient hospitalization. Results: Twenty patients were assigned to the suture and Seamguard reinforcement groups. The groups were similar in terms of preoperative characteristics. No staple line dehiscence occurred in the two groups, whereas two cases of dehiscence occurred in the fibrin glue group. No mortality occurred and surgical time was statistically similar for both techniques. Seamguard made the surgery more expensive. Conclusion: In our service, staple line reinforcement in open bariatric surgery with oversewing or Seamguard was considered to be safe. Seamguard application was considered to be easier than oversewing, but more expensive.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hepatectomy may prolong the survival of colorectal cancer patients with liver metastases. Two-stage liver surgery is a valid option for the treatment of bilobar colorectal liver metastasis. This video demonstrates technical aspects of a two-stage pure laparoscopic hepatectomy for bilateral liver metastasis. To the authors` knowledge, this is the first description of a two-stage laparoscopic liver resection in the English literature. A 54-year-old man with right colon cancer and synchronous bilobar colorectal liver metastasis underwent laparoscopic right colon resection followed by oxaliplatin-based chemotherapy. The patient then was referred for surgical treatment of liver metastasis. Liver volumetry showed a small left liver remnant. Surgical planning was for a totally laparoscopic two-stage liver resection. The first stage involved laparoscopic resection of segment 3 and ligature of the right portal vein. The postoperative pathology showed high-grade liver steatosis. After 4 weeks, the left liver had regenerated, and volumetry of left liver was 43%. The second stage involved laparoscopic right hepatectomy using the intrahepatic Glissonian approach. Intrahepatic access to the main right Glissonian pedicle was achieved with two small incisions, and an endoscopic vascular stapling device was inserted between these incisions and fired. The line of liver transection was marked following the ischemic area. Liver transection was accomplished with the Harmonic scalpel and an endoscopic stapling device. The specimen was extracted through a suprapubic incision. The falciform ligament was fixed to maintain the left liver in its original anatomic position, avoiding hepatic vein kinking and outflow syndrome. The operative time was 90 min for stage 1 and 240 min for stage 2 of the procedure. The recoveries after the first and second operations were uneventful, and the patient was discharged on postoperative days 2 and 7, respectively. Two-stage liver resections can be performed safely using laparoscopy. The intrahepatic Glissonian approach is a useful tool for pedicle control of the right liver, especially after previous dissection of the hilar plate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bisegmentectomy 7-8 is feasible even in the absence of a large inferior right hepatic vein. To our knowledge, this operation has never been performed by laparoscopy. This study was designed to present video of pure laparoscopic bisegmentectomy 7-8 and bisegmentectomy 2-3 in one-stage operation for bilateral liver metastasis. A 67-year-old man with metachronous bilobar colorectal liver metastasis was referred for surgical treatment after neoadjuvant chemotherapy. CT scan disclosed two liver metastases: one located between segments 7 and 8 and another one in segment 2. At liver examination, another metastasis was found on segment 3. We decided to perform a bisegmentectomy 7-8 along with bisegmentectomy 2-3 in a single procedure. The operation began with mobilization of the right liver with complete dissection of retrohepatic vena cava. Inferior right hepatic vein was absent. Right hepatic vein was dissected and encircled. Upper part of right liver, containing segment 7 and 8, was marked with cautery. Selective hemi-Pringle maneuver was performed and right hepatic vein was divided with stapler. At this point, liver rotation to the left allowed direct view and access to the superior aspect of the right liver. Liver transection was accomplished with harmonic scalpel and endoscopic stapling device. Bisegmentectomy 2-3 was performed using the intrahepatic Glissonian approach. The specimens were extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 240 minutes with no need for transfusion. Recovery was uneventful. Patient was discharged on the fifth postoperative day. Patient is well with no evidence of disease 14 months after liver resection. Tumor markers are within normal range. Bisegmentectomy 7-8 may increase resectability rate in patients with bilateral lesions. This operation can be performed safely by laparoscopy. Preservation of segments 5 and 6 permitted simultaneous resection of segments 2 and 3 with adequate liver remnant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experience with advanced techniques has increased the indications for laparoscopic liver resection. This video demonstrates technical aspects of a pure laparoscopic mesohepatectomy using intrahepatic Glissonian technique. To the best of our knowledge, this is the first case of anatomic laparoscopic mesohepatectomy using the Glissonian approach published in the English literature. A 62-year-old man with colorectal liver metastasis occupying central liver segments was referred for surgical treatment. The first step is the control of segment 4 pedicle. Using the round ligament as a guide, one incision is performed on its right margin and another is made at the bottom of segment 4. A vascular clamp is introduced through those incisions to occlude segment 4 Glissonian sheath. The next step is to control the right anterior pedicle. The first incision is made in front of the hilum and another is performed on the right edge of gallbladder bed. Laparoscopic clamp is introduced through these incisions and closed producing ischemic discoloration of segments 5 and 8. Vascular clamp is replaced by an endoscopic vascular stapling device and stapler is fired. Line of liver transection is marked along the liver surface following ischemic area. Liver transection is accomplished with bipolar vessel sealing device and endoscopic stapling device as appropriate. Specimen was extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 200 min with minimum blood loss and no need for blood transfusion. Recovery was uneventful, and the patient was discharged on the fifth postoperative day. Histological examination revealed clear surgical margins. Mesohepatectomy can be safely performed laparoscopically in selected patients and by surgeons with expertise in both liver surgery and laparoscopic techniques. The use of the intrahepatic Glissonian approach may help to identify the exact limits of the mesohepatectomy to avoid ischemic injury of the remnant liver.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fibrin sealing has recently evolved as a new technique for mesh fixation in endoscopic inguinal hernia repair. A comprehensive Medline search was carried out evaluating fibrin sealant for mesh fixation, and finally 12 studies were included (3 randomized trials, 3 nonrandomized trials, and 6 case series). The trials were assessed for operative time, seroma formation, recovery time, recurrence rate, and acute and chronic pain.There was a trend toward decreased operative times for fibrin sealing compared with mechanical stapling; however, the results for seroma formation remained contradictory. The most important finding was the reduced postoperative pain. Recovery times were lower after fibrin sealing and the recurrence rates showed no differences.Fibrin sealing for mesh fixation in the endoscopic inguinal hernia surgery is a promising alternative to mechanical stapling, which can be safely applied. As the overall quality of published data remains poor, further well-designed studies are needed until fibrin sealing can replace mechanical stapling as a new standard for mesh fixation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: Circular stapled mucosectomy is the standard therapy for the treatment of symptomatic third-degree haemorrhoids and mucosal prolapse. Recently, new staplers made in China have entered the market offering an alternative to the PPH stapling devices. The aim of this prospective randomized study was to compare the safety and efficacy of these new devices. METHODS: Fifty patients with symptomatic third-degree haemorrhoids were randomized to mucosectomy either by using stapler A (CPH32; Frankenman International Ltd, Hong Kong, China; n = 25) or stapler B (PPH03; Ethicon Endo-Surgery, Spreitenbach, Switzerland; n = 25). All procedures were performed by two experienced surgeons. After the stapler was fired by one surgeon, the other surgeon, who was blinded for stapler type, evaluated the stapler line. Postoperative outcome including pain, complications and patient satisfaction were analysed. RESULTS: Demographic and clinical features were no different between the groups. There was no significant difference regarding venous bleeding (P = 0.55), but arterial bleeding was significantly more frequent when stapler B was used (P < 0.001). This led to significantly more suture ligations (P = 0.002). However, no differences regarding operation time (P = 0.99), weight of the resected mucosa (P = 0.81) and height of the stapler line (anterior, P = 0.18; posterior, P = 0.65) were detected. Postoperative pain scores (visual analogue scale) and patient satisfaction were no different either (P = 0.91 and P = 0.78, respectively). No recurrence or incontinence occurred during follow-up. CONCLUSIONS: CPH32 required significantly fewer sutures for bleeding control along the stapler line after circular mucosectomy. However, operation time, rate of postoperative complications and patient satisfaction were similar in both groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Totally extraperitoneal laparoscopic hernia repair is an efficient but technically demanding procedure. As mechanisms of hernia recurrence may be related to these technical difficulties, we have modified a previously described double-mesh technique in an effort to simplify the procedure. Extraperitoneal laparoscopic hernia repairs were performed in 82 male and 17 female patients having inguinal, femoral, and recurrent bilateral hernias. A standard propylene mesh measuring 15 x 15 cm was cut into two pieces of 4 x 15 cm and 11 x 15 cm. The smaller mesh was placed over both inguinal rings without splitting. The larger mesh was then inserted over the first mesh and stapled to low-risk zones, reinforcing the large-vessel area and the nerve transition zone. The mean procedure duration was 60 minutes for unilateral and 100 minutes for bilateral hernia repair. Patients were discharged from the hospital within 48 hours. The mean postoperative follow-up was 22 months, with no recurrences, neuralgia, or bleeding complications. Over a 2-year period, this technique was found to be satisfactory without recurrences or significant complications. In our hands, this technique was easier to perform: it allows for a less than perfect positioning of the meshes and avoids most of the stapling to crucial zones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The strength properties of paper coating layer are very important in converting and printing operations. Too great or low strength of the coating can affect several problems in printing. One of the problems caused by the strength of coating is the cracking at the fold. After printing the paper is folded to final form and the pages are stapled together. In folding the paper coating can crack causing aesthetic damage over printed image or in the worst case the centre sheet can fall off in stapling. When folding the paper other side undergoes tensile stresses and the other side compressive stresses. If the difference between these stresses is too high, the coating can crack on the folding. To better predict and prevent cracking at the fold it is good to know the strength properties of coating layer. It has measured earlier the tensile strength of coating layer but not the compressive strength. In this study it was tried to find some way to measure the compressive strength of the coating layer and investigate how different coatings behave in compression. It was used the short span crush test, which is used to measure the in-plane compressive strength of paperboards, to measure the compressive strength of the coating layer. In this method the free span of the specimen is very small which prevent buckling. It was measured the compressive strength of free coating films as well as coated paper. It was also measured the tensile strength and the Bendtsen air permeance of the coating film. The results showed that the shape of pigment has a great effect to the strength of coating. Platy pigment gave much better strength than round or needle-like pigment. On the other hand calcined kaolin, which is also platy but the particles are aggregated, decreased the strength substantially. The difference in the strength can be explained with packing of the particles which is affecting to the porosity and thus to the strength. The platy kaolin packs up much better than others and creates less porous structure. The results also showed that the binder properties have a great effect to the compressive strength of coating layer. The amount of latex and the glass transition temperature, Tg, affect to the strength. As the amount of latex is increasing, the strength of coating is increasing also. Larger amount of latex is binding the pigment particles better together and decreasing the porosity. Compressive strength was increasing when the Tg was increasing because the hard latex gives a stiffer and less elastic film than soft latex.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Painelajittelu on yksi yleisimmistä yksikköprosesseista paperin ja sellun valmistuksessa. Suurelta osin lajittimet toimivat niille asetettujen vaatimusten mukaisesti, mutta joissakin tapauksissa lajittimissa saattaa esiintyä ei-toivottavaa kuitujen kasautumista sekä kehräymän muodostusta. Niiden seurauksena lajittimien kapasiteetti alenee ja lajittelutulos heikkenee. Tämän työn tarkoituksena on uutta kuvantamistekniikkaa hyödyntäen selvittää miten kehräymät ja kuitukasaumat syntyvät painelajittimen sihtipinnalla ja miten retentioaineen syöttö sihdin ympäristössä vaikuttaa niiden syntyyn. Työn kirjallisuusosassa tarkastellaan painelajittimen toimintaa, rakennetta sekä lyhyen kierron konesihdin erityispiirteitä. Lisäksi tarkastellaan retentiokemikaalien käyttäytymistä leikkausvoimien alaisuudessa ja kuitukehräymien syntyä painelajittimissa. Kokeellisessa osassa on raportoitu kuvantamisjärjestelmällä saatuja tuloksia sekä esitetään havaintoja kehräymien ja kuitukasaumien synnystä ja niiden vaikutuksista painelajittimen toimintaan. Kuvausten perusteella voidaan sanoa, että kehräymän syntyminen sihdissä vaatii aina jonkinlaisen kuitukasauman olemassaoloa. Tällaista alkukasaumaa tarvitaan, jotta kuidut voivat ankkuroitua siihen kiinni ja johon kiinnittyneenä kuidut alkavat pyöriä virtauksessa muodostaen kehräymää. Kuitukasauman muodostuminen painelajittimessa johtuu pääosin sihdissä olevasta epäjatkuvuuskohdasta, massassa olevista epäpuhtauksista ja kuituflokeista jotka jäävät kiinni sihtipinnan aukkoihin tai lajittimen kapasiteetin ylittymisestä. Kehräymän syntyä kasauman jäljessä voidaan pitää enemmän sääntönä kuin poikkeuksena, mutta kehräytyminen on vähäisempää reikäsihdillä kuin rakosihdillä. Silloituspolymeerillä flokattu massa ei muodosta herkemmin kuitukasaumia sihtipintaan verrattuna flokkaamattomaan massaan. Lajiteltavan massan sakeuden nosto vähentää kuitukasaumien ja kehräymien syntyä. Kuitukasaumien ja kehräymien välttämiseksi on tärkeää, että sihtiä ei ajeta suunniteltua mitoitusaluetta suuremmilla tuotannoilla tai virtauksilla.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El manejo del trauma abdominal supone el reto de realizar una anastomosis o sutura intestinal en pacientes comprometidos hemodinámicamente. La decisión de cirugía de control de daños ante la presencia de acidosis, hipotermia y coagulopatía es evidente, sin embargo la situación no siempre es tan clara. En individuos con trauma se desarrollan cambios moleculares e inflamatorios por inadecuado balance entre aporte y demanda de oxígeno, que afectan el proceso de reparación de los tejidos con el riesgo de aparición de fístulas. Una forma rápida y práctica de detectar esta hipoperfusión es midiendo la saturación venosa de oxígeno (SVO2) y el Lactato Sérico. OBJETIVOS: Establecer correlación entre los valores de SVO2 transoperatorio y la aparición de fístulas intestinales en pacientes intervenidos por trauma abdominal. MATERIALES Y METODOS: Estudio de cohorte prospectivo que analiza diferentes variables en relación con la aparición de fistulas en pacientes con trauma abdominal que requieren suturas en el tracto gastrointestinal, haciendo énfasis en los niveles de SVO2. RESULTADOS: Los pacientes con falla anastomótica, presentaron un promedio de SVO2 más baja (60.0% ± 2.94%), versus los no fistulizados (69.89% ± 7.21%) (p =0.010). Todos los pacientes de la cohorte expuesta (SVO2<65%), presentaron dehiscencia de la anastomosis (RR =39.8, IC95%: 2.35,659.91, p<0.001, Test exacto de Fisher). El valor predictivo positivo de la saturación (<65%) fue de 57.14% (IC 95%: 13.34%, 100%) y el valor predictivo negativo fue de 100% (IC 95%:81.75%, 100%). La sensibilidad fue de 100% (IC 95%:87.50%, 100%) y especificidad de 91.89% (IC 95%: 81.75%, 100%). En el análisis bivariante determinó que el índice de trauma abdominal, el nivel de hemoglobina y el requerimiento de transfusión de glóbulos rojos, son factores de riesgo directamente relacionados con la falla de la anastomosis en pacientes con trauma abdominal CONCLUSIONES: - Hay una fuerte relación entre la falla en la reparación intestinal y SVO2 < 65%. - El pronóstico de una anastomosis intestinal está directamente relacionada con el estado hemodinámico y la perfusión tisular al momento de la intervención quirúrgica. - El nivel de SVO2 puede apoyar al cirujano en la decisión de realizar o no una reparación en víscera hueca al momento de intervención quirúrgica en un paciente con trauma abdominal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to greater productivity in the auto industry and the high competition in the current market, employees are required to perform repeated movements and often, with short intervals of rest. This daily exposure causes muscle tension and overloads occasional, thus creating problems and psychosocial stress. Currently companies are concerned with the welfare of the employee, where the main focus is product quality and life of the worker, thus justifying such a study. Therefore , this technical work to assist the master's thesis of graduate student Daniel Rodriguez , was developed with the objective is to analyze , develop, design and construct a coupled to a load cell device simulating a stitcher to be used in an industry the posts stapling upholstery of seats . Are the stages of design and construction detailed in this work and its positive results in relation to the technical part of the study