914 resultados para splenic artery


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It was reported that prevention of acute portal overpressure in small-for-size livers by inflow modulation results in a better postoperative outcome. The aim is to investigate the impact of portal blood flow reduction by splenic artery ligation after major hepatectomy in a murine model. Forty-eight rats were subjected to an 85% hepatectomy or 85% hepatectomy and splenic artery ligation. Both groups were evaluated at 24, 48, 72 and 120 post-operative hours: liver function, regeneration and viability. All methods and experiments were carried out in accordance with Coimbra University guidelines. Splenic artery ligation produces viability increase after 24 h, induces a relative decrease in oxidative stress during the first 48 hours, allows antioxidant capacity increment after 24 h, which is reflected in a decrease of half-time normalized liver curve at 48 h and at 72 h and in an increase of mitotic index between 48 h and 72 h. Splenic artery ligation combined with 85% hepatectomy in a murine model, allows portal inflow modulation, promoting an increase in hepatocellular viability and regeneration, without impairing the function, probably by inducing a less marked elevation of oxidative stress at first 48 hours.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. The present report describes a full endovascular treatment of a multiple anomalous (Splenic artery aneurysms) SAA with combination of coils embolization and proximal occlusion of the splenic artery with the Amplatzer vascular plug. Case report. A 53-year-old Jehovah witness woman presented with multiple aneurysms arising from an anomalous splenic artery. An endovascular treatment was performed by implantation of multiple coils and an Amplatzer Vascular Plug. A CT scan 2 months after the procedure showed complete thrombosis of the aneurysms. Discussion. Aneurysms involving an anomalous or aberrant splenic artery are rarely reported in the literature. Their surgical treatment involves potential difficulties as a consequence of anatomical position and vascular anomalies. A fully endovascular technique can be much more attractive compared to any surgical management, providing an effective and minimally invasive option. Splenic artery - Aberrant splenic artery - Aneurysm - Endovascular treatment - Jehovah witness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It was reported that prevention of acute portal overpressure in small-for-size livers by inflow modulation results in a better postoperative outcome. The aim is to investigate the impact of portal blood flow reduction by splenic artery ligation after major hepatectomy in a murine model. Forty-eight rats were subjected to an 85% hepatectomy or 85% hepatectomy and splenic artery ligation. Both groups were evaluated at 24, 48, 72 and 120 post-operative hours: liver function, regeneration and viability. All methods and experiments were carried out in accordance with Coimbra University guidelines. Splenic artery ligation produces viability increase after 24 h, induces a relative decrease in oxidative stress during the first 48 hours, allows antioxidant capacity increment after 24 h, which is reflected in a decrease of half-time normalized liver curve at 48 h and at 72 h and in an increase of mitotic index between 48 h and 72 h. Splenic artery ligation combined with 85% hepatectomy in a murine model, allows portal inflow modulation, promoting an increase in hepatocellular viability and regeneration, without impairing the function, probably by inducing a less marked elevation of oxidative stress at first 48 hours.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mediante esta pesquisa, estudamos os arranjos configurados pela artéria celíaca em 30 patos domésticos Cairina moshata, sendo 20 machos e 10 fêmeas. Foi realizada a injeção de látex corado no sistema arterial e depois as peças foram fixadas em solução aquosa de formol a 10% para posterior dissecação dos vasos arteriais. A artéria celíaca nasce isoladamente da aorta descendente e fornece a artéria proventricular dorsal e a artéria esofágica e a seguir continua-se como tronco de dois outros ramos: esquerdo e direito. O ramo esquerdo emite um vaso que vasculariza a porção ventral do proventrículo (artéria proventricular ventral) e porção terminal do esôfago e, a seguir, fornece 3 ramos que vascularizam a face lateral esquerda e a margem cranial da moela ou ventrículo, bem como a junção pilórica na sua porção cranial. do vaso destinado à margem cranial da moela, surgem artérias ao lobo hepático esquerdo em número de 1 em 5 preparações (16,6% ± 6,8), 2 em 14 peças (46,66% ± 9,1) ou 3 em 8 peças (26,66% ± 8,1). O ramo direito envia inicialmente as artérias esplênicas cujo número foi de 2 em 6 preparações (20% ± 7,3), 3 em 12 peças (40% ± 8,9), 4 em 8 peças (26,6% ± 8,1), 5 em 3 peças (10% ± 5,5) e 6 em 1 preparação (3,33% ± 3,3). em seguida, emite colaterais ao lobo hepático direito que foram em número de 2 em 21 preparações (70% ± 8,4) ou 3 em 9 preparações (30% ± 8,4). Ainda, o ramo direito emite artérias endereçadas ao ceco esquerdo em número de 2 em 17 preparações (56,66% ± 9,1) ou 3 em 13 casos (43,33% ± 9,1). O ramo direito origina ainda 3 vasos endereçados à face lateral direita da moela (ventrículo), à margem caudal e à junção pilórica em sua porção mais caudal. A seguir, o ramo direito da artéria celíaca continua-se como artéria pancreaticoduodenal que supre o pâncreas e as porções ascendente e descendente do duodeno.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A artéria lienal mostra dois comportamentos antes de penetrar no hilo do baço, compondo o Grupo I (90%) com um ramo extra-hilar e o Grupo II (10%) com 2 destes ramos. Após penetrar, origina em média 13 ramos para a margem cranial e 10 para a margem caudal. A veia lienal freqüentemente (96,6%) está representada por um único vaso de trajeto longitudinal no eixo dorsoventral, para onde confluem em média 13 vasos da margem cranial e 11 da margem caudal, e raramente (3,3%) esta veia resulta da confluência de 2 vasos de calibres equivalentes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The parenchymal distribution of the splenic artery was studied in order to obtain anatomical basis for partial splenectomy. Thirty two spleens were studied, 26 spleens of healthy horses weighing 320 to 450kg, aged 3 to 12 years and 6 spleens of fetus removed from slaughterhouse. The spleens were submitted to arteriography and scintigraphy in order to have their vascular pattern examined and compared to the external aspect of the organ aiming establish anatomo-surgical segments. All radiographs were photographed with a digital camera and the digital images were submitted to a measuring system for comparative analysis of areas of dorsal and ventral anatomo-surgical segments. Anatomical investigations into the angioarchitecture of the equine spleen showed a paucivascular area, which coincides with a thinner external area, allowing the organ to be divided in two anatomo-surgical segments of approximately 50% of the organ each.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The accurate measurement of Cardiac output (CO) is vital in guiding the treatment of critically ill patients. Invasive or minimally invasive measurement of CO is not without inherent risks to the patient. Skilled Intensive Care Unit (ICU) nursing staff are in an ideal position to assess changes in CO following therapeutic measures. The USCOM (Ultrasonic Cardiac Output Monitor) device is a non-invasive CO monitor whose clinical utility and ease of use requires testing. Objectives To compare cardiac output measurement using a non-invasive ultrasonic device (USCOM) operated by a non-echocardiograhically trained ICU Registered Nurse (RN), with the conventional pulmonary artery catheter (PAC) using both thermodilution and Fick methods. Design Prospective observational study. Setting and participants Between April 2006 and March 2007, we evaluated 30 spontaneously breathing patients requiring PAC for assessment of heart failure and/or pulmonary hypertension at a tertiary level cardiothoracic hospital. Methods SCOM CO was compared with thermodilution measurements via PAC and CO estimated using a modified Fick equation. This catheter was inserted by a medical officer, and all USCOM measurements by a senior ICU nurse. Mean values, bias and precision, and mean percentage difference between measures were determined to compare methods. The Intra-Class Correlation statistic was also used to assess agreement. The USCOM time to measure was recorded to assess the learning curve for USCOM use performed by an ICU RN and a line of best fit demonstrated to describe the operator learning curve. Results In 24 of 30 (80%) patients studied, CO measures were obtained. In 6 of 30 (20%) patients, an adequate USCOM signal was not achieved. The mean difference (±standard deviation) between USCOM and PAC, USCOM and Fick, and Fick and PAC CO were small, −0.34 ± 0.52 L/min, −0.33 ± 0.90 L/min and −0.25 ± 0.63 L/min respectively across a range of outputs from 2.6 L/min to 7.2 L/min. The percent limits of agreement (LOA) for all measures were −34.6% to 17.8% for USCOM and PAC, −49.8% to 34.1% for USCOM and Fick and −36.4% to 23.7% for PAC and Fick. Signal acquisition time reduced on average by 0.6 min per measure to less than 10 min at the end of the study. Conclusions In 80% of our cohort, USCOM, PAC and Fick measures of CO all showed clinically acceptable agreement and the learning curve for operation of the non-invasive USCOM device by an ICU RN was found to be satisfactorily short. Further work is required in patients receiving positive pressure ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The high morbidity and mortality associated with atherosclerotic coronary vascular disease (CVD) and its complications are being lessened by the increased knowledge of risk factors, effective preventative measures and proven therapeutic interventions. However, significant CVD morbidity remains and sudden cardiac death continues to be a presenting feature for some subsequently diagnosed with CVD. Coronary vascular disease is also the leading cause of anaesthesia related complications. Stress electrocardiography/exercise testing is predictive of 10 year risk of CVD events and the cardiovascular variables used to score this test are monitored peri-operatively. Similar physiological time-series datasets are being subjected to data mining methods for the prediction of medical diagnoses and outcomes. This study aims to find predictors of CVD using anaesthesia time-series data and patient risk factor data. Several pre-processing and predictive data mining methods are applied to this data. Physiological time-series data related to anaesthetic procedures are subjected to pre-processing methods for removal of outliers, calculation of moving averages as well as data summarisation and data abstraction methods. Feature selection methods of both wrapper and filter types are applied to derived physiological time-series variable sets alone and to the same variables combined with risk factor variables. The ability of these methods to identify subsets of highly correlated but non-redundant variables is assessed. The major dataset is derived from the entire anaesthesia population and subsets of this population are considered to be at increased anaesthesia risk based on their need for more intensive monitoring (invasive haemodynamic monitoring and additional ECG leads). Because of the unbalanced class distribution in the data, majority class under-sampling and Kappa statistic together with misclassification rate and area under the ROC curve (AUC) are used for evaluation of models generated using different prediction algorithms. The performance based on models derived from feature reduced datasets reveal the filter method, Cfs subset evaluation, to be most consistently effective although Consistency derived subsets tended to slightly increased accuracy but markedly increased complexity. The use of misclassification rate (MR) for model performance evaluation is influenced by class distribution. This could be eliminated by consideration of the AUC or Kappa statistic as well by evaluation of subsets with under-sampled majority class. The noise and outlier removal pre-processing methods produced models with MR ranging from 10.69 to 12.62 with the lowest value being for data from which both outliers and noise were removed (MR 10.69). For the raw time-series dataset, MR is 12.34. Feature selection results in reduction in MR to 9.8 to 10.16 with time segmented summary data (dataset F) MR being 9.8 and raw time-series summary data (dataset A) being 9.92. However, for all time-series only based datasets, the complexity is high. For most pre-processing methods, Cfs could identify a subset of correlated and non-redundant variables from the time-series alone datasets but models derived from these subsets are of one leaf only. MR values are consistent with class distribution in the subset folds evaluated in the n-cross validation method. For models based on Cfs selected time-series derived and risk factor (RF) variables, the MR ranges from 8.83 to 10.36 with dataset RF_A (raw time-series data and RF) being 8.85 and dataset RF_F (time segmented time-series variables and RF) being 9.09. The models based on counts of outliers and counts of data points outside normal range (Dataset RF_E) and derived variables based on time series transformed using Symbolic Aggregate Approximation (SAX) with associated time-series pattern cluster membership (Dataset RF_ G) perform the least well with MR of 10.25 and 10.36 respectively. For coronary vascular disease prediction, nearest neighbour (NNge) and the support vector machine based method, SMO, have the highest MR of 10.1 and 10.28 while logistic regression (LR) and the decision tree (DT) method, J48, have MR of 8.85 and 9.0 respectively. DT rules are most comprehensible and clinically relevant. The predictive accuracy increase achieved by addition of risk factor variables to time-series variable based models is significant. The addition of time-series derived variables to models based on risk factor variables alone is associated with a trend to improved performance. Data mining of feature reduced, anaesthesia time-series variables together with risk factor variables can produce compact and moderately accurate models able to predict coronary vascular disease. Decision tree analysis of time-series data combined with risk factor variables yields rules which are more accurate than models based on time-series data alone. The limited additional value provided by electrocardiographic variables when compared to use of risk factors alone is similar to recent suggestions that exercise electrocardiography (exECG) under standardised conditions has limited additional diagnostic value over risk factor analysis and symptom pattern. The effect of the pre-processing used in this study had limited effect when time-series variables and risk factor variables are used as model input. In the absence of risk factor input, the use of time-series variables after outlier removal and time series variables based on physiological variable values’ being outside the accepted normal range is associated with some improvement in model performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Acute coronary syndromes are a major cause of mortality and morbidity. Objectives/Methods: The objective of this evaluation is to review the clinical trials of two new drugs being developed for the treatment of acute coronary syndromes. The first drug is the anti-coagulant otamixaban, and the trial compared otamixaban with unfractionated heparin and eptifibatide in acute coronary syndromes. The second drug is the anti-platelet ticagrelor, and the trial compared ticagrelor with clopidogrel in acute coronary syndromes. Results: In the SEPIA-ACS1 TIMI 42 trial, the primary efficacy endpoint occurred in 6.2% of subjects treated with unfractionated heparin and eptifibatide, and to a significantly lesser extent with otamixaban. In the PLATO trial, the primary efficacy endpoint had occurred less in the ticagrelor group (9.8%) than in the clopidogrel group (11.7%) at 12 months. Conclusions: Two new drugs for acute coronary syndromes, otamixaban and ticagrelor, have recently been shown to have benefits in subjects undergoing percutaneous interventions compared to the present standard regimens for this condition.