225 resultados para sphincter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES We have evaluated prospectively the long-term efficacy of the artificial urinary sphincter (AUS) AMS 800 for the treatment postradical prostatectomy urinary incontinence (PRPUI) patients. We also evaluated the correlation between preoperative urodynamic findings and surgical outcomes. METHODS From May 1997 to April 2003, 40 consecutive patients with PRPUI caused by intrinsic sphincter deficiency (ISD) were treated with the AMS 800. Mean age was 68.3 +/- 6.3 years. Continence status was evaluated on the basis of pad count, impact of urinary incontinence on the quality of life, complications, and surgical revisions. Preoperative urodynamic findings were correlated with surgical outcomes. RESULTS Follow-up ranged from 27 to 132 months (mean = 53.4 +/- 21.4 months). There was a significant reduction in pad count from 4.0 +/- 0.9 to 0.62 +/- 1.07 diapers per day (P <0.001) leading to continence in 90%. There was a significant reduction on the impact of incontinence decreasing from 5.0 +/- 0.7 to 1.4 +/- 0.93 (P <0.001) in a visual analogue scale (VAS). Surgical revision rate was 20%. Preoperative urodynamics was useful to identify sphincter deficiency. Except by a tendency of worse results in patients with reduced bladder compliance (RBC), other urodynamic parameters did not correlate with a worse surgical outcome. CONCLUSIONS The AMS 800 offers good long-term continence to most PRPUI patients. Preoperative findings like detrusor hyperactivity (DH), impaired detrusor contraction (IDC), low Valsalva leak point pressure, bladder outlet obstruction (BOO), and mild RBC were not associated with worse surgical outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. This study aimed to evaluate manometric parameters that may explain improvement in anal incontinence using a silicone bulking agent. Methods. Incontinent patients having internal sphincter defects were prospectively selected and injected with a silicone bulking agent. Manometry and endoanal ultrasound were performed before and 3 months after injections. Twenty continent healthy volunteers were used only for manometric comparison. Results. Thirty-five patients (28 females; mean age 60.3 years) and 20 controls entered this study. Patients had lower resting and squeeze pressures compared with controls (P<.05). Length of the high-pressure zone increased from 1 to 1.7 cm postinjection (P=.002). Asymmetry index showed a significant change postinjection (P<.001). Conclusion. Despite considerable clinical improvement, no significant increase in manometric pressures was noted posttreatment. There was significant improvement in both high-pressure zone and asymmetry index, and these findings may explain the mechanism of action of the bulking agent injected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There seems to be controversy on the anorectal sphincter presentation and anatomical division, as well as on its functional representation. Evaluation of the anorectal sphincter musculature has been achieved through several methods, including anorectal manometry and computerized tomography, but to date there is no experimental model allowing a detailed manometric study of this muscle complex. In this work, we have developed such a model, which should enable the manometric and radiographic study of the anatomical features and functional mechanisms of sphincteric injuries, as well as the assessment of drug effects on the anorectal musculature upon incontinence and constipation. Twenty-two piglets (aged 25-30 days, weighing 5-7 kg) were studied by anorectal manometry (rectoanal inhibitory reflex and vector volume) and computerized tomography (anorectal angle and anal canal length). The data obtained for the rectoanal inhibitory reflex, represented here as the average and standard deviation, were the following: relaxation duration = 14.75 +/- 3.62 s, sphincter basal pressure = 41.58 +/- 8.20 mmHg, relaxation index = 87.26 +/- 11.52%, speed of relaxation = 5.90 +/- 2.10 mm/s, and speed of relaxation recovery = 4.03 +/- 1.78 mm/s. As for the vector volume, results were as follows: vector volume = 2692.32 +/- 1298.12 mmHg(2) cm, sphincter length = 11.82 +/- 2.74 mm, high pressure zone length = 5.09 +/- 1.34 mm, maximum pressure = 61.50 +/- 20.58 mmHg, and asymmetry index = 43.50 +/- 10.03%. Radiographic evaluation led to the following results: anal canal length = 9.61 +/- 2.14 mm and anorectal angle = 137.91 +/- 7.75 degrees. The experimental model designed here allows both anorectal manometry and computerized tomography to be carried out in the same way it is performed in human beings, as long as animal sedation is strictly controlled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was made the characterization of marginal sphincter to the species Phymactis clematis (Drayton in Dana, 1849) and Aulactinia marplatensis (Zamponi, 1977), from intertidal ecosystem through their morphogical and functional study. The species P. clematis has a circumscript sphincter of palmate type. This muscle is constituted by a mesogloeal axis and several mesogloeal subaxes. Axis as well as subaxes give a support to the endoderm which border is smooth. Aulactinia marplatensis has a circunscript sphincter pinnate type. The axis has a truncated cone shape while in P. clematis the shape is cylindrical on its origin and it is bifurcated at the end. Both species experiments were carried out using the isolated muscles. They were stimulated at increasing KCl concentrations ranging from 20 to 200 mM. The results were analysed in the form of dose-response curves expressed in tension in grams force vs concentration. Contractil force increases in a sigmoid form to increasing KCl concentrations. The correlation between morphology and function and the differences shown in both species would be related to their intertidal distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION AND HYPOTHESIS: This study aims to estimate fecal, urinary incontinence, and sexual function 6 years after an obstetrical anal sphincter tear. METHODS: Among 13,213 women who had a vaginal delivery of a cephalic singleton at term, 196 women sustained an anal sphincter tear. They were matched to 588 controls. Validated questionnaires grading fecal and urinary incontinence, and sexual dysfunction were completed by the participants. RESULTS: Severe fecal incontinence was more frequently reported by women who had sustained an anal sphincter tear compared to the controls. Women with an anal sphincter tear had no increased risk of urinary incontinence, but reported significantly more pain, difficulty with vaginal lubrication, and difficulty achieving orgasm compared to the controls. A fetal occiput posterior position during childbirth was an independent risk factor for both severe urinary incontinence and severe sexual dysfunction. CONCLUSIONS: Fecal incontinence is strongly associated with an anal sphincter tear. A fetal occiput posterior position represents a risk factor for urinary incontinence and sexual dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: There are only a few established artificial urinary sphincters for treatment of incontinence. We have developed a new device composed by three parts: the actuator, three contractile rings and a control unit. The actuator is made of Nitinol fibers, driven by microprocessor. The fibers are linked to the rings placed around the urethra. They function with alternance in their open and closed position. This concept is called piano concept. With this set-up, the constant compression on the urethra is strongly reduced. Methods: Six male sheep have been used for this study. The sphincter was open each hour for a period of 10 min., to guaranty urination. The bladder was filled with water while one cuff was closed and bladder pressure was monitored. The animals were sacrificed. Two biopsies around two cuffs of each explant and all three cuffs from each explant including urethra were analyzed. Urethra not surrounded by a cuff was taken as control. Results: The pressure exerted by the sphincter around the urethra provided continence. Simulated incontinence occurred at a pressure of 1bar measured on the bladder wall using a pressure probe. The closing force of the cuff was approx. 0·7N. No difference in tissue structure and organization of the urethra with and without artificial sphincter was observed. Conclusions: This device has several advantages compared to other urinary sphincters. It is easy to implant, has no hydraulic nature and reduces ischemic injury of the urethra by the alternance of urethral part compressed. Proof of concept in vivo has been demonstrated. Other studies are planned to determine long-term outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction and objectives: The AMS 800TM is considered the gold standard for sphincter replacement. However, the one-ring design can erode the urethra and lead to severe complications. A mechanism that could alternatively compress successive segments of the urethra would limit such deleterious outcome. We report 12 weeks animal urethral tissue analysis following implantation of a new modular artificial sphincter. METHODS: The device is composed by three parts: the contractile unit, two rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor connected to an external computer. The computer can reveal specific failure of device components. The device was impkanted in eight male sheep. The rings were positioned around the urethra and the control unit was placed 5cm away. The device was working twenty hours per day; it was open 10min. per hour to allow urination. The animals were sacrificed after 12 weeks. The urethra and the tissues surrounding the control unit were macroscopically and microscopically examined. Two transversal sections crossing the sphincter and two transversal sections crossing the urethra alone were obtained and stained with modified Paragon after resin embedding. Urethra was also embedded in paraffin. The first section was stained with safranin-hematoxylin-eosin, the second section was stained with Masson's Trichrome and the remaining eight sections were available for immunolabelling of the macrophages.Results: The chronic study went uneventful. No clinical infection or pain was observed. The computer registered no specific failure in ring function, Nitinol wires and tube connectors. At explantation, except for a slight grade of lymphocytes in two out of eight specimens, no urethral stricture or atrophy could be observed. Immunohistochemistry confirmed the absence of macrophages. Tissue structure and organization of the urethra with and without artificial sphincter were similar. No migration of the device was observed.Conclusions: The study clearly showed no tissue damage or inflammation of the urethra. Electronic design, preservation of urethral vascularisation and adjustability after implantation are the key ideas to improve the actual AUS. Further studies will be carried out to evaluate this potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The AMS 800 is the current artifi cial urinary sphincter (AUS) forincontinence due to intrinsic sphincter defi ciency. Despite good clinical results,technical failures inherent to the hydraulic mechanism or urethral ischemicinjury contribute to revisions up to 60%. We are developing an electronic AUS,called ARTUS to overcome the rigors of AMS. The objective of this study wasto evaluate the technical effi cacy and tissue tolerance of the ARTUS systemin an animal model.Methods: The ARTUS is composed by three parts: thecontractile unit, a series of rings and an integrated microprocessor. The contractileunit is made of Nitinol fi bers. The rings are placed around the urethrato control the fl ow of urine by squeezing the urethra. They work in a sequentialalternative mode and are controlled by a microprocessor. In the fi rst phase athree-rings device was used while in the second phase a two-rings ARTUS wasused. The device was implanted in 14 sheep divided in two groups of six andeight animals for study purpose. The fi rst group aimed at bladder leak pointpressure (BLPP) measurement and validation of the animal model; the secondgroup aimed at verifying midterm tissue tolerance by explants at twelve weeks.General animal tolerance was also evaluated.Results: The ARTUS systemimplantation was uneventful. When the system was activated, the BLPP wasmeasured at 1.038 ± 0.044 bar (mean ± SD). Urethral tissue analysis did notshow signifi cant morphological changes. No infection and no sign of discomfortwere noted in animals at 12 weeks.Conclusions: The ARTUS proved to beeffective in continence achievement in this study. Histological results supportour idea that a sequential alternative mode can avoid urethral atrophy andischemia. Further technical developments are needed to verify long-termoutcome and permit human use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate by electromyography (EMG), the presence of complex repetitive discharges (CRDs) and decelerating bursts (DBs) in the striated external urethral sphincter during the menstrual cycle in female volunteers with no urinary symptoms and complete bladder emptying. SUBJECTS AND METHODS: Healthy female volunteers aged 20-40 years, with regular menstrual cycles and no urinary symptoms were recruited. Volunteers completed a menstruation chart, urinary symptom questionnaires, pregnancy test, urine dipstick, urinary free flow and post-void ultrasound bladder scan. Exclusion criteria included current pregnancy, use of hormonal medication or contraception, body mass index of >35 kg/m(2) , incomplete voiding and a history of pelvic surgery. Eligible participants underwent an external urethral sphincter EMG, using a needle electrode in the early follicular phase and the mid-luteal phase of their menstrual cycles. Serum oestradiol and progesterone were measured at each EMG test. RESULTS: In all, 119 women enquired about the research and following screening, 18 were eligible to enter the study phase. Complete results were obtained in 15 women. In all, 30 EMG tests were undertaken in the 15 asymptomatic women. Sphincter EMG was positive for CRDs and DBs at one or both phases of the menstrual cycle in eight (53%) of the women. Three had CRDs and DBs in both early follicular and mid-luteal phases. Five had normal EMG activity in the early follicular phase and CRDs and DBs in the mid-luteal phase. No woman had abnormal EMG activity in the early follicular phase and normal activity in the luteal phase. There was no relationship between EMG activity and age, parity or serum levels of oestradiol and progesterone. CONCLUSIONS: CRDs and DB activity in the external striated urethral sphincter is present in a high proportion of asymptomatic young women. This abnormal EMG activity has been shown for the first time to change during the menstrual cycle in individual women. CRDs and DBs are more commonly found in the luteal phase of the menstrual cycle. The importance of CRDs and DBs in the aetiology of urinary retention in young women remains uncertain. The distribution and or quantity of abnormal EMG activity in the external urethral sphincter may be important. In a woman with urinary retention the finding of CRDs and DBs by needle EMG does not automatically establish Fowler's syndrome as the explanation for the bladder dysfunction. Urethral pressure profilometry may be helpful in establishing a diagnosis. Opiate use and psychological stress should be considered in young women with urinary retention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

But de l'étude Un enregistrement spécifique EMG du sphincter strié urétral avec décharges répétitives et complexes ainsi que salves de décélération a été décrit comme pathognomonique du syndrome de Fowler, un trouble de la relaxation du sphincter strié urétral chez la femme jeune responsable d'une retention urinaire. Nous avons souhaité étudier la présence de cet enregistrement EMG spécifique chez la femme asymptomatique, ceci à différents moments du cycle menstruel. Matériel et Méthode Nous avons recruté des femmes volontaires saines âgées entre 20 et 40 ans, ayant un cycle hormonal régulier, et ne présentant aucun symptôme urinaire. Les critères d'exclusion étaient la presence d'une dysfonction mictionnelle, d'une infection urinaire, la grossesse, la prise d'une thérapie hormonale ou d'hormone contraceptive, une obésité et des antécédants d'intervention pelvienne. Nous avons procédé à deux enregistrements EMG du sphincter strié urétral des participantes éligibles, utilisant une aiguille concentrique, ceci dans la première phase du cycle (phase folliculaire) et dans la dernière phase du cycle (phase lutéale). Les taux sériques de progestérone et d'oestrogène étaient mesurés à chaque enregistrement. Résultats 15 participantes ont complété l'étude. L' enregistrement EMG du sphincter a été positif avec présence de décharges répétitives et de salves de décélération lors d'une ou des deux phases du cycle menstruel chez 8 participantes (53%). Trois participantes présentaient cet enregistrement spécifique lors des deux phases du cycle et cinq participantes présentaient cet enregistrement spécifique lors de la phase lutéale uniquement. Aucune femme ne présentait cet enregistrement spécifique en début de cycle uniquement. Il n'y avait pas de relation avec l'âge, la parité ou les taux hormonaux. Conclusions L'enregistrement EMG spécifique du sphincter strié urétral, avec décharges répétitives et salves de décélération, se retrouve chez une proportion élevée de femmes asymptomatiques. Il a été montré que ce tracé change lors du cycle menstruel, en étant retrouvé plus fréquemment dans la dernière phase du cycle. L'importance de cet enregistrement EMG dans l'étiologie de la retention urinaire de la femme jeune reste à éclaircir. Nous devons considérer que sa présence ne pose pas automatiquement un diagnostic de syndrome de Fowler chez la femme en rétention urinaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most important component of the upper esophageal sphincter (UES) is the cricopharyngeal muscle. During the measurement of sphincter pressure the catheter passed through the sphincter affects the pressure value. In Chagas' disease and primary achalasia there is an esophageal myenteric plexus denervation which may affect UES pressure. We measured the UES pressure of 115 patients with Chagas' disease, 28 patients with primary achalasia and 40 healthy volunteers. We used a round manometric catheter with continuous perfusion and the rapid pull-through method, performed in triplicate during apnea. Pressures were measured in four directions, and the direction with the highest pressure (anterior/posterior) and the average of the four directions were measured. The highest UES pressure in Chagas' disease patients without abnormalities upon radiologic esophageal examination (N = 63) was higher than in normal volunteers (142.8 ± 47.4 mmHg vs 113.0 ± 46.0 mmHg, mean ± SD, P<0.05). There was no difference in UES pressure between patients with primary achalasia and patients with Chagas' disease and similar esophageal involvement and normal volunteers (P>0.05). There was no difference between patients with or without esophageal dilation. In the group of subjects less than 50 years of age the UES pressure of primary achalasia (N = 21) was lower than that of Chagas' disease patients with normal radiologic esophageal examination (N = 41), measured at the site with the highest pressure (109.3 ± 31.5 mmHg vs 149.6 ± 45.3 mmHg, P<0.01) and as the average of the four directions (64.2 ± 17.1 mmHg vs 83.5 ± 28.6 mmHg, P<0.05). We conclude that there is no difference in UES pressure between patients with Chagas' disease, primary achalasia and normal volunteers, except for patients with minor involvement by Chagas' disease, for whom the UES pressure at the site with the highest pressure was higher than the pressure of normal volunteers and patients with primary achalasia.