995 resultados para spectrometry spectra interpretation
Resumo:
This work describes a systematic method to be applied in undergraduate courses of organic chemistry, correlating infrared spectra, hydrogen and carbon-13 nuclear magnetic resonance, and mass spectra. To this end, a scheme and a table were developed to conduct the elucidation of the structure of organic compounds initially using infrared spectra. Interpretation of hydrogen and carbon-13 nuclear magnetic resonance spectra and of mass spectra is used to confirm the proposed structure.
Resumo:
This paper introduces the basics of peptide mass spectra interpretation applied to proteomics and is directed to chemists, biochemists and biologists. The manuscript presents a well detailed protocol aiming to serve as a first choice guide for understanding peptide sequencing. The tutorial was elaborated based on both a thorough bibliographic revision and the author's experience. In order to prove the applicability of the proposed guide, spectra obtained on different instruments have been successfully interpreted by applying the presented rational.
Resumo:
Gas chromatography coupled with mass spectrometry (GC-MS) is widely used for the characterization of volatile compounds. However, due to the complexity of the soluble coffee matrix, a complete identification of the components should not be based on mass spectra interpretation only. The linear index of retention (LRI) is frequently used to give support to mass spectra. The aim of this work is to investigate the characterization of the volatile compounds in soluble coffee samples by GC-MS using LRI values found with a HP-INNOWAX column. The method used allows a significant increase of the reliability of identifying compounds.
Resumo:
This paper introduces the basics of peptide mass spectra interpretation applied to proteomics and is directed to chemists, biochemists and biologists. The manuscript presents a well detailed protocol aiming to serve as a first choice guide for understanding peptide sequencing. The tutorial was elaborated based on both a thorough bibliographic revision and the author's experience. In order to prove the applicability of the proposed guide, spectra obtained on different instruments have been successfully interpreted by applying the presented rational.
Resumo:
This paper introduces the basics of peptide mass spectra interpretation applied to proteomics and is directed to chemists, biochemists and biologists. The manuscript presents a well detailed protocol aiming to serve as a first choice guide for understanding peptide sequencing. The tutorial was elaborated based on both a thorough bibliographic revision and the author's experience. In order to prove the applicability of the proposed guide, spectra obtained on different instruments have been successfully interpreted by applying the presented rational.
Resumo:
The GENCODE Consortium aims to identify all gene features in the human genome using a combination of computational analysis, manual annotation, and experimental validation. Since the first public release of this annotation data set, few new protein-coding loci have been added, yet the number of alternative splicing transcripts annotated has steadily increased. The GENCODE 7 release contains 20,687 protein-coding and 9640 long noncoding RNA loci and has 33,977 coding transcripts not represented in UCSC genes and RefSeq. It also has the most comprehensive annotation of long noncoding RNA (lncRNA) loci publicly available with the predominant transcript form consisting of two exons. We have examined the completeness of the transcript annotation and found that 35% of transcriptional start sites are supported by CAGE clusters and 62% of protein-coding genes have annotated polyA sites. Over one-third of GENCODE protein-coding genes are supported by peptide hits derived from mass spectrometry spectra submitted to Peptide Atlas. New models derived from the Illumina Body Map 2.0 RNA-seq data identify 3689 new loci not currently in GENCODE, of which 3127 consist of two exon models indicating that they are possibly unannotated long noncoding loci. GENCODE 7 is publicly available from gencodegenes.org and via the Ensembl and UCSC Genome Browsers.
Resumo:
This article decribes a simple and systematic method to interpret an infrared spectrum using a flow chart to elucidate the structure of a simple organic compound. It is aimed at undergraduate courses of organic chemistry to make beginners proficient. The proposed flow chart for infrared spectrum interpretation and characterization of organic compounds is suitable for theoretical and experimental courses.
Resumo:
In the present work qualitative aspects of products that fall outside the classic Italian of food production view will be investigated, except for the apricot, a fruit, however, less studied by the methods considered here. The development of computer systems and the advanced software systems dedicated for statistical processing of data, has permitted the application of advanced technologies including the analysis of niche products. The near-infrared spectroscopic analysis was applied to the chemical industry for over twenty years and, subsequently, was applied in food industry with great success for non-destructive in line and off-line analysis. The work that will be presented below range from the use of spectroscopy for the determination of some rheological indices of ice cream applications to the characterization of the main quality indices of apricots, fresh dates, determination of the production areas of pistachio. Next to the spectroscopy will be illustrated different methods of multivariate analysis for spectra interpretation or for the construction of qualitative models of estimation. The thesis is divided into four separate studies that consider the same number of products. Each one of it is introduced by its own premise and ended with its own bibliography. This studies are preceded by a general discussion on the state of art and the basics of NIR spectroscopy.
Resumo:
Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.
Resumo:
Actualment, la resposta de la majoria d’instrumentació operacional i dels dosímetres personals utilitzats en radioprotecció per a la dosimetria neutrònica és altament dependent de l’energia dels espectres neutrònics a analitzar, especialment amb camps neutrònics amb una important component intermitja. En conseqüència, la interpretació de les lectures d’aquests aparells es complicada si no es té un coneixement previ de la distribució espectral de la fluència neutrònica en els punts d’interès. El Grup de Física de les Radiacions de la Universitat Autònoma de Barcelona (GFR-UAB) ha desenvolupat en els últims anys un espectròmetre de neutrons basat en un Sistema d’Esferes Bonner (BSS) amb un contador proporcional d’3He com a detector actiu. Els principals avantatges dels espectròmetres de neutrons per BSS són: la seva resposta isotròpica, la possibilitat de discriminar la component neutrònica de la gamma en camps mixtos, i la seva alta sensibilitat neutrònica als nivells de dosi analitzats. Amb aquestes característiques, els espectròmetres neutrònics per BSS compleixen amb els estándards de les últimes recomanacions de la ICRP i poden ser utilitzats també en el camp de la dosimetria neutrònica per a la mesura de dosis en el rang d’energia que va dels tèrmics fins als 20 MeV, en nou ordres de magnitud. En el marc de la col•laboració entre el GFR - UAB i el Laboratorio Nazionale di Frascati – Istituto Nazionale di Fisica Nucleare (LNF-INFN), ha tingut lloc una experiència comparativa d’espectrometria per BSS amb els feixos quasi monoenergètics de 2.5 MeV i 14 MeV del Fast Neutron Generator de l’ENEA. En l’exercici s’ha determinat l’espectre neutrònic a diferents distàncies del blanc de l’accelerador, aprofitant el codi FRUIT recentment desenvolupat pel grup LNF. Els resultats obtinguts mostren una bona coherència entre els dos espectròmetres i les dades mesurades i simulades.
Resumo:
DFT and TD-DFT calculations (ADF program) were performed in order to analyze the electronic structure of the [M-3(CO)(12)] clusters (M = Ru, Os) and interpret their electronic spectra. The highest occupied molecular orbitals are M-M bonding (sigma) involving different M-M bonds, both for Ru and Os. They participate in low-energy excitation processes and their depopulation should weaken M-M bonds in general. While the LUMO is M-NI and M-CO anti-bonding (sigma*), the next, higher-lying empty orbitals have a main contribution from CO (pi*) and either a small (Ru) or an almost negligible one (Os) from the metal atoms. The main difference between the two clusters comes from the different nature of these low-energy unoccupied orbitals that have a larger metal contribution in the case of ruthenium. The photochemical reactivity of the two clusters is reexamined and compared to earlier interpretations.
Resumo:
The complexity of biological samples poses a major challenge for reliable compound identification in mass spectrometry (MS). The presence of interfering compounds that cause additional peaks in the spectrum can make interpretation and assignment difficult. To overcome this issue, new approaches are needed to reduce complexity and simplify spectral interpretation. Recently, focused on unknown metabolite identification, we presented a new approach, RANSY (ratio analysis of nuclear magnetic resonance spectroscopy; Anal. Chem. 2011, 83, 7616-7623), which extracts the signals related to the same metabolite based on peak intensity ratios. On the basis of this concept, we present the ratio analysis of mass spectrometry (RAMSY) method, which facilitates improved compound identification in complex MS spectra. RAMSY works on the principle that, under a given set of experimental conditions, the abundance/intensity ratios between the mass fragments from the same metabolite are relatively constant. Therefore, the quotients of average peak ratios and their standard deviations, generated using a small set of MS spectra from the same ion chromatogram, efficiently allow the statistical recovery of the metabolite peaks and facilitate reliable identification. RAMSY was applied to both gas chromatography/MS and liquid chromatography tandem MS (LC-MS/MS) data to demonstrate its utility. The performance of RAMSY is typically better than the results from correlation methods. RAMSY promises to improve unknown metabolite identification for MS users in metabolomics or other fields.